MIB Viewer

fddimibPORTAction

OBJECT-TYPE
1.3.6.1.2.1.10.15.73.5.2.1.25
Access
read-write
Status
mandatory
Sub-identifiers
0
Causes a Control signal to be generated with a control_action of 'Signal' and the 'variable' parameter set with the appropriate value (i.e., PC_Maint, PC_Enable, PC_Disable, PC_Start, or PC_Stop) (refer to ANSI 9.4.2).
INTEGER { other(1), maintPORT(2), enablePORT(3), disablePORT(4), startPORT(5), stopPORT(6) }