MIB Viewer

fsMplsTpTraceLevel

OBJECT-TYPE
1.3.6.1.4.1.10876.101.1.8.1.2.1.7
Access
read-write
Status
current
Sub-identifiers
0
This object is used to enable Trace Statements in MPLS Module. A FOUR BYTE integer is used for enabling the level of tracing. Each BIT in the four byte integer, represents a particular level of Trace. The mapping between the bit positions & the level of trace is as follows: 0x100000 - Function Entry or Exit Traces 0x010000 - Management Traces 0x001000 - Main Traces 0x000100 - Util Traces 0x000010 - Traces related to All Resources except Buffers 0x000001 - All Failure Traces The remaining bits are unused. Combination of levels are also allowed. For example if the bits 0 and 1 are set, then the Trace statements related to Init-Shutdown and management will be printed. The user has to enter the corresponding INTEGER VALUE for the bits set. For example if bits 0 and 1 are set then user has to set the value 3.
Unsigned32