gnAgnLogFileOduPowerSupply

OBJECT-TYPE
1.3.6.1.4.1.2281.2.2.2.4.1.16
Access
read-only
Status
mandatory
Sub-identifiers
0
This is the ODU power supply status, during the alarm acceptance bit 1 on = +5V faulty bit 2 on = +8V faulty bit 3 on = +12V faulty bit 4 on = -12V faulty.