MIB Viewer

jnxPppMlPppLinkConfigRowStatus

OBJECT-TYPE
1.3.6.1.4.1.2636.3.68.1.1.6.3.1.7
Access
read-only
Status
current
Sub-identifiers
0
Controls creation/deletion of entries in this table with read-carete maximum access,according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: jnxPppMlPppLinkConfigRowStatus jnxPppMlPppLinkConfigLowerIfIndex In addition, when creating an entry the following conditions must hold: A value for jnxPppMlPppLinkConfigIndex must have been determined previously, by reading jnxPppMlPppNextIfIndex. The interface identified by jnxPppMlPppLinkConfigLowerIfIndex must exist. A corresponding entry in ifTable/ifXTable/jnxIfTable is created/destroyed as a result of creating/destroying an entry in this table. The following values can be read from this object: active(1)
RowStatus