MIB Viewer

lcsErpsConfigInstanceGuardTime

OBJECT-TYPE
1.3.6.1.4.1.2356.14.2.24.3.3
Access
read-write
Status
current
Sub-identifiers
0
The period of the guard timer can be configured in 10 ms steps between 10 ms and 2 seconds, with a default value of 500 ms. Guard timeout value to be used to prevent ring nodes from receiving outdated R-APS messages.
Integer32