iso/org/dod/internet/private/enterprises/.15007/.1/mefSoamPmMib/.1/.3/mefSoamDmCfgMeasBinTable/mefSoamDmCfgMeasBinEntry/mefSoamDmCfgMeasBinLowerBound
mefSoamDmCfgMeasBinLowerBound
OBJECT-TYPE
1.3.6.1.4.1.15007.1.3.1.3.2.1.3
Description
This object specifies the lower boundary for a measurement bin. The upper boundary is defined by the next bin value or infinite for the last bin defined. The measurement boundary for each measurement bin is to be larger than the measurement boundary of the preceding measurement bin. By default, the next bin is set to 5000us larger than the lower bin boundary. The values in a bin boundary object represents the time range used to segregate delay data into the appropriate statistical data bin. For five bins with default values, each bin has the following time range: bin 1 = 0, range is 0us <= measurement < 5,000us bin 2 = 5000, range is 5,000us <= measurement < 10,000us bin 3 = 10000, range is 10,000us <= measurement < 15,000us bin 4 = 15000, range is 15,000us <= measurement < 20,000us bin 5 = 20000, range is 20,000us <= measurement < infinity The first bin boundary (mefSoamDmCfgBinNumber set to 1) always contains the value of 0. Attempting to write a non-zero value to this bin will result in an error.
Syntax
Unsigned32