iso/org/dod/internet/private/enterprises/.15007/.1/mefSoamPmMib/.1/.3/mefSoamDmThresholdCfgTable/mefSoamDmThresholdCfgEntry/mefSoamDmThresholdCfgEnable
mefSoamDmThresholdCfgEnable
OBJECT-TYPE
1.3.6.1.4.1.15007.1.3.1.3.8.1.2
Description
A vector of bits that indicates the type of SOAM DM threshold notifications that are enabled. A bit set to '1' enables the specific SOAM DM threshold notification and when the specific counter is enabled and the threshold is crossed a notification is generated. A bit set to '0' disables the specific SOAM DM threshold notification. If a particular SOAM DM threshold is not supported the BIT value is set to '0'. bMefSoamDmMeasuredFrameDelayTwoWayThreshold(0) Enables/disables measured frame two-way delay threshold notification. The notification is sent immediately when the mefSoamDmMeasuredStatsFrameDelayTwoWay value is greater than or equal to threshold value. bMefSoamDmMaxFrameDelayTwoWayThreshold(1) Enables/disables maximum frame two-way delay threshold notification. The notification is sent immediately when the mefSoamDmCurrentStatsFrameDelayTwoWayMax value is greater than or equal to threshold value in a Measurement Interval. bMefSoamDmAvgFrameDelayTwoWayThreshold(2) Enables/disables average frame two-way delay threshold notification. The notification is sent when at the end of a Measurement Interval if the mefSoamDmCurrentStatsFrameDelayTwoWayAvg value is greater than or equal to the threshold value. bMefSoamDmMeasuredIfdvTwoWayThreshold(3) Enables/disables measured frame IFDV two-way threshold notification. The notification is sent immediately when the mefSoamDmMeasuredStatsIfdvTwoWay value is greater than or equal to threshold value. bMefSoamDmMaxIfdvTwoWayThreshold(4) Enables/disables maximum frame IFDV two-way threshold notification. The notification is sent immediately when the mefSoamDmCurrentStatsIfdvTwoWayMax value is greater than or equal to threshold value in a Measurement Interval. bMefSoamDmAvgIfdvTwoWayThreshold(5) Enables/disables average frame IFDV two-way threshold notification. The notification is sent when at the end of a Measurement Interval if the mefSoamDmCurrentStatsIfdvTwoWayAvg value is greater than or equal to the threshold value. bMefSoamDmMaxFrameDelayRangeTwoWayThreshold(6) Enables/disables maximum Frame Delay Range two-way threshold notification. The notification is sent immediately when the mefSoamDmCurrentStatsFrameDelayRangeTwoWayMax value is greater than or equal to threshold value in a Measurement Interval. bMefSoamDmAvgFrameDelayRangeTwoWayThreshold(7) Enables/disables average Frame Delay Range two-way threshold notification. The notification is sent when at the end of a Measurement Interval if the mefSoamDmCurrentStatsFrameDelayRangeTwoWayAvg value is greater than or equal to the threshold value. bMefSoamDmMeasuredFrameDelayForwardThreshold(8) Enables/disables measured forward frame delay threshold notification. The notification is sent immediately when the mefSoamDmMeasuredStatsFrameDelayForward value is greater than or equal to threshold value. bMefSoamDmMaxFrameDelayForwardThreshold(9) Enables/disables maximum forward frame delay threshold notification. The notification is sent immediately when the mefSoamDmCurrentStatsFrameDelayForwardMax value is greater than or equal to threshold value in a Measurement Interval. bMefSoamDmAvgFrameDelayForwardThreshold(10) Enables/disables average forward frame delay threshold notification. The notification is sent when at the end of a Measurement Interval if the mefSoamDmCurrentStatsFrameDelayForwardAvg value is greater than or equal to the threshold value. bMefSoamDmMeasuredIfdvForwardThreshold(11) Enables/disables measured frame IFDV forward threshold notification. The notification is sent immediately when the mefSoamDmMeasuredStatsIfdvForward value is greater than or equal to threshold value. bMefSoamDmMaxIfdvForwardThreshold(12) Enables/disables maximum frame IFDV forward threshold notification. The notification is sent immediately when the mefSoamDmCurrentStatsIfdvForwardMax value is greater than or equal to threshold value in a Measurement Interval. bMefSoamDmAvgIfdvForwardThreshold(13) Enables/disables average frame IFDV forward threshold notification. The notification is sent when at the end of a Measurement Interval if the mefSoamDmCurrentStatsIfdvForwardAvg value is greater than or equal to the threshold value. bMefSoamDmMaxFrameDelayRangeForwardThreshold(14) Enables/disables maximum Frame Delay Range forward threshold notification. The notification is sent immediately when the mefSoamDmCurrentStatsFrameDelayRangeForwardMax value is greater than or equal to threshold value in a Measurement Interval. bMefSoamDmAvgFrameDelayRangeForwardThreshold(15) Enables/disables average Frame Delay Range forward threshold notification. The notification is sent when at the end of a Measurement Interval if the mefSoamDmCurrentStatsFrameDelayRangeForwardAvg value is greater than or equal to the threshold value. bMefSoamDmMeasuredFrameDelayBackwardThreshold(16) Enables/disables measured backward frame delay threshold notification. The notification is sent immediately when the mefSoamDmMeasuredStatsFrameDelayBackward value is greater than or equal to threshold value. bMefSoamDmMaxFrameDelayBackwardThreshold(17) Enables/disables maximum backward frame delay threshold notification. The notification is sent immediately when the mefSoamDmCurrentStatsFrameDelayBackwardMax value is greater than or equal to threshold value in a Measurement Interval. bMefSoamDmAvgFrameDelayBackwardThreshold(18) Enables/disables average backward frame delay threshold notification. The notification is sent when at the end of a Measurement Interval if the mefSoamDmCurrentStatsFrameDelayBackwardAvg value is greater than or equal to the threshold value. bMefSoamDmMeasuredIfdvBackwardThreshold(19) Enables/disables measured frame IFDV backward threshold notification. The notification is sent immediately when the mefSoamDmMeasuredStatsIfdvBackward value is greater than or equal to threshold value. bMefSoamDmMaxIfdvBackwardThreshold(20) Enables/disables maximum frame IFDV backward threshold notification. The notification is sent immediately when the mefSoamDmCurrentStatsIfdvBackwardMax value is greater than or equal to threshold value in a Measurement Interval. bMefSoamDmAvgIfdvBackwardThreshold(21) Enables/disables average frame IFDV backward threshold notification. The notification is sent when at the end of a Measurement Interval if the mefSoamDmCurrentStatsIfdvBackwardAvg value is greater than or equal to the threshold value. bMefSoamDmMaxFrameDelayRangeBackwardThreshold(22) Enables/disables maximum Frame Delay Range backward threshold notification. The notification is sent immediately when the mefSoamDmCurrentStatsFrameDelayRangeBackwardMax value is greater than or equal to threshold value in a Measurement Interval. bMefSoamDmAvgFrameDelayRangeBackwardThreshold(23) Enables/disables average Frame Delay Range backward threshold notification. The notification is sent when at the end of a Measurement Interval if the mefSoamDmCurrentStatsFrameDelayRangeBackwardAvg value is greater than or equal to the threshold value.
Syntax
BITS { bMefSoamDmMeasuredFrameDelayTwoWayThreshold(0), bMefSoamDmMaxFrameDelayTwoWayThreshold(1), bMefSoamDmAvgFrameDelayTwoWayThreshold(2), bMefSoamDmMeasuredIfdvTwoWayThreshold(3), bMefSoamDmMaxIfdvTwoWayThreshold(4), bMefSoamDmAvgIfdvTwoWayThreshold(5), bMefSoamDmMaxFrameDelayRangeTwoWayThreshold(6), bMefSoamDmAvgFrameDelayRangeTwoWayThreshold(7), bMefSoamDmMeasuredFrameDelayForwardThreshold(8), bMefSoamDmMaxFrameDelayForwardThreshold(9), bMefSoamDmAvgFrameDelayForwardThreshold(10), bMefSoamDmMeasuredIfdvForwardThreshold(11), bMefSoamDmMaxIfdvForwardThreshold(12), bMefSoamDmAvgIfdvForwardThreshold(13), bMefSoamDmMaxFrameDelayRangeForwardThreshold(14), bMefSoamDmAvgFrameDelayRangeForwardThreshold(15), bMefSoamDmMeasuredFrameDelayBackwardThreshold(16), bMefSoamDmMaxFrameDelayBackwardThreshold(17), bMefSoamDmAvgFrameDelayBackwardThreshold(18), bMefSoamDmMeasuredIfdvBackwardThreshold(19), bMefSoamDmMaxIfdvBackwardThreshold(20), bMefSoamDmAvgIfdvBackwardThreshold(21), bMefSoamDmMaxFrameDelayRangeBackwardThreshold(22), bMefSoamDmAvgFrameDelayRangeBackwardThreshold(23) }