MIB Viewer

modmHubClockRate

OBJECT-TYPE
1.3.6.1.4.1.164.3.4.1.2.1.6
Access
read-write
Status
current
Sub-identifiers
0
Clock Rate in bps. The rates are the original T1/E1 rates or the rates divided by 2n. For modmHubT1E1=e1, instances (1)-(9) are applicable. For modmHubT1E1=t1, instances (31)-(36) are applicable. For modmHubT1E1=other, instance (255) is applicable.
INTEGER { e1r2048000 (1), e1r1024000 (2), e1r512000 (3), e1r256000 (4), e1r128000 (5), e1r64000 (6), e1r32000 (7), e1r16000 (8), e1r8000 (9), t1r1544000 (31), t1r772000 (32), t1r386000 (33), t1r193000 (34), t1r96500 (35), t1r48250 (36), notApplicable (255) }