MIB Viewer

mwlGlobalSave

OBJECT-TYPE
1.3.6.1.4.1.15983.3.1.2.1.16
Access
read-write
Status
current
Sub-identifiers
0
Setting this variable with the value 'start' triggers the save of the running configuration to the startup configuration, so that changes will persist across reboots. All changes made via SETs for SNMP tables are applied to the running configuration only. You should set this variable at the end of every group of updates if you want your configuration to persist.
ActionStatus