MIB Viewer

prtExPhPlFullRptPeriod

OBJECT-TYPE
1.3.6.1.4.1.164.3.2.3.2.3.1.1.24
Access
read-write
Status
current
Sub-identifiers
0
This object is the Full Report Frequency. It determines the number of the Status Enquiry messages sent by the FR user side, before a Full Report Request is sent. The units are : Status Enquiry messages (periods). Valid values: 1 .. 255. 255 = infinite. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
Integer32 (1..255)