MIB Viewer

snarSaveChanges

OBJECT-TYPE
1.3.6.1.4.1.164.5.1.1.5
Access
read-write
Status
current
Sub-identifiers
0
N/A to SNAR, only for devices. When changes are made to any configuration parameters (SNA, NVA or others) it should be stored in the device's NVRAM and then the device is restarted. Using this variable the manager can: 2 - Just save into NVRAM all configuration changes 3 - Save into NVRAM the configuration changes and restart the Device, to reflect the changes. 4 - Undo all changes since last reset or save, (without resetting the device). Load the original configuration from the NVRAM.
INTEGER{ noSave (1), save (2), saveAndReset (3), undoAllChanges (4) }