MIB Viewer

swL2QOSSchedulingMaxLatency

OBJECT-TYPE
1.3.6.1.4.1.2272.1.201.1.2.6.2.1.3
Access
read-write
Status
current
Sub-identifiers
0
Indicates the maximum amount of time the hardware priority queue will be allowed to transmit packets before allowing the next lowest priority queue to begin transmit its packets. A value between 0 and 255 can be specified- with this value multiplied by 16 ms to arrive at the total allowed time for queue to transmit packets. For example, a value of 3 specifies 3*16=48 ms. The queue will continue transmitting the last packet until it is finished when the max_latency timer expires.
INTEGER (0..255)