MIB Viewer

syncELocalQuality

OBJECT-TYPE
1.3.6.1.4.1.27975.81.5
Access
read-write
Status
current
Sub-identifiers
0
Set the device quality globally under option1. The meanings of the values are: op2-prs(1) - Primary reference source; op1-prc(2) - Primary reference clock; op2-eec2(3) - EEC2 clock(ITU-T G.8264); op1-eec1(4) - EEC1 clock(ITU-T G.8264); op1-dnu(5) - Do not use this quality; op2-dus(6) - Do not use for synchronization
INTEGER {op2-prs(1), op1-prc(2), op2-eec2(3), op1-eec1(4),op1-dnu(5), op2-dus(6)}