MIB Viewer

t11FcSpAuDefaultLifetime

OBJECT-TYPE
1.3.6.1.2.1.176.1.1.1.7
Access
read-write
Status
current
Sub-identifiers
0
When the value of this object is non-zero, it specifies the default value of a lifetime, specified in units given by the corresponding instance of t11FcSpAuDefaultLifetimeUnits. This default lifetime is to be used for any Security Association that has no explicitly specified value for its lifetime. An SA's lifetime is either the time interval or the number of passed bytes, after which the SA has to be terminated and (if necessary) replaced with a new SA. If this object is zero, then there is no default value for lifetime.
T11FcSpLifetimeLeft