0
The value of tmnxCohOptPortModRxTurnUpStates indicates the completed RX turn-up states of the coherent optical module. init - The entry state, in which configuration of the RX path is performed. laserReady - The RX LO (Local Oscillator) laser is tuned. waitForInput - The RX input tap is monitored for power that exceeds the LOS threshold. adcSignal - When RX input power above LOS is detected, the module transitions to the ADC Signal (Analog-to-Digital Converter Signal) state. In the ADC Signal state the module calibrates the optical ADCs. opticalLock - This state (and state demodLock) reflects DSP operations by the demodulator. demodLock - In this state, RX path turn-up is achieved.
BITS { init (0), laserReady (1), waitForInput (2), adcSignal (3), opticalLock (4), demodLock (5) }