MIB Viewer

tmnxDS1BerSdThreshold

OBJECT-TYPE
1.3.6.1.4.1.6527.3.1.2.2.4.12.1.24
Access
read-create
Status
current
Sub-identifiers
0
The value of tmnxDS1BerSdThreshold specifies a bit error rate (BER) threshold used to determine when to send a tmnxEqPortDS1Alarm notification for a BER SD failure and a tmnxEqPortDS1AlarmClear notification for a BER SD failure clear. Bit error computed must reach/exceed threshold value over a pre-defined period of time for the tmnxEqPortSonetAlarm notification to be sent. The value of tmnxDS1Framing defines how the bit error is computed and what values of tmnxDS1BerSdThreshold are allowed. The following table defines this dependency: tmnxDS1Framing Bit error calculation and value supported esf (1) each CRC error is counted as one bit error g704 (4) values supported are 1,5,10,50,100 other values bit error alarms not supported, value of tmnxDS1BerSdThreshold set to default and cannot be changed tmnxDS1BerSdThreshold value must not exceed the value of tmnxDS1BerSfThreshold.
Unsigned32 (1|5|10|50|100)