MIB Viewer

tmnxOamPmCfgThrLossAvgFlrRaise

OBJECT-TYPE
1.3.6.1.4.1.6527.3.1.2.92.1.3.13.1.3
Access
read-write
Status
current
Sub-identifiers
0
The value of tmnxOamPmCfgThrLossAvgFlrRaise specifies the raise threshold for the average Frame Loss Ratio (FLR). Depending on the specified indices, tmnxOamPmCfgThrLossAvgFlrRaise is the raise threshold for: tmnxOamPmStsLossSlmAvgFlrFwd, tmnxOamPmStsLossSlmAvgFlrBwd, tmnxOamPmStsLossLmmAvgFlrFwd, tmnxOamPmStsLossLmmAvgFlrBwd, tmnxOamPmStsLossTwlAvgFlrFwd, or tmnxOamPmStsLossTwlAvgFlrBwd. For example, suppose: 1. OAM-PM loss TCAs are enabled for the 'mi15minutes(2)' measurement interval of the OAM-PM session OAM_PM_Eth_session_1 (using tmnxOamPmCfgMeasIntvlLossTCAs and tmnxOamPmCfgMeasIntvlTCAs). 2. tmnxOamPmCfgThrLossAvgFlrRaise is set to 5000 (i.e. 5.000%) for the indices {OAM_PM_Eth_session_1, 'slm(2)', 'forward(1)'}. 3. At the end of a 15 minute interval belonging to OAM_PM_Eth_session_1's SLM test, the average FLR (i.e. tmnxOamPmStsLossSlmAvgFlrFwd) is 5000 (i.e. 5.000%) or more. 4. Generating an average FLR Raise TCA is allowed (e.g. the most recent average FLR TCA for the specified indices was a Clear). Then, SROS generates an average FLR Raise TCA (using tmnxOamPmThrRaise) at the end of the 15-minute interval, for the forward direction. Negative one specifies that average FLR thresholding is disabled for the specified indices (i.e. SROS will not generate a Raise TCA, or a Clear TCA). tmnxOamPmCfgThrLossAvgFlrRaise must be greater than tmnxOamPmCfgThrLossAvgFlrClear. Exception: the combination tmnxOamPmCfgThrLossAvgFlrRaise=-1 and tmnxOamPmCfgThrLossAvgFlrClear=-1 is supported. tmnxOamPmCfgThrLossAvgFlrRaise and tmnxOamPmCfgThrLossAvgFlrClear must be set in the same SNMP Set PDU.
Integer32 (-1 | 1..100000)