MIB Viewer

tmnxOamPmCfgTwampLtConsecDeltaTs

OBJECT-TYPE
1.3.6.1.4.1.6527.3.1.2.92.1.3.9.1.11
Access
read-create
Status
current
Sub-identifiers
0
The value of tmnxOamPmCfgTwampLtConsecDeltaTs specifies the number of consecutive MEF-35 'delta_t's (also known as 'Small Time Intervals') which constitute a MEF-35 'Availability Window' when computing loss statistics for the specified session's TWAMP-Light test. The loss parameters used by SROS for TWAMP-Light tests (e.g. tmnxOamPmCfgTwampLtConsecDeltaTs) are modelled after the MEF-35 loss parameters defined for Synthetic Loss Measurement (SLM) tests. Hence, the REFERENCE text for this object is a MEF-35 SLM section. The duration of an Availability Window (in milliseconds) is tmnxOamPmCfgTwampLtTxFrmsPerDelT * tmnxOamPmCfgTwampLtInterval * tmnxOamPmCfgTwampLtConsecDeltaTs. An attempt to change the duration of an Availability Window to more than 100,000 milliseconds will be rejected. An attempt to change tmnxOamPmCfgTwampLtConsecDeltaTs to a value less than or equal to tmnxOamPmCfgTwampLtChliThreshold will be rejected.
Unsigned32 (2..10)