MIB Viewer

tnPmonPolicyFlrAvailabilityInterval15Min

OBJECT-TYPE
1.3.6.1.4.1.7483.6.1.2.99.2.1.9
Access
read-create
Status
current
Sub-identifiers
0
This object specifies an configurable availability interval in unit of seconds to be used in evaluating the availability/unavailability status for 15-min Loss Measurement PM monitoring. This object is equivalent to the Availability parameter of 'delta_t' as specified by MEF 10.2.1. For SLM tool, the number of SLM PDU sent during this interval must be in the range of 10 through 100. For LM tool, the number of LMM PDU sent during this interval must be in the range of 1 through 10 must be supported. The range of this object is product-specific.
Integer32