This is an indicator of whether master-slave synchronization utilizes follow-up messaging (IEEE 1588-2008 Section 8.2.1.2.1.). This parameter is read-only. A PTP port has a configurable parameter which determines if follow-up messaging will be used for this port. true: If some of the PTP ports in the clock use follow-up messaging. false: If none of the PTP ports in the clock use follow-up messaging. Only false is supported in the current PTP implementation.