MIB Viewer

tnVwmMsPmudActualEVoaBandInLine1Out

OBJECT-TYPE
1.3.6.1.4.1.7483.2.2.6.1.1.9.1.12
Access
read-only
Status
current
Sub-identifiers
0
Actual attenuation value of the eVOA in the BAND IN port in case the TX selector points to the LINE1 OUT port. When tnVwmMsPmudEVoaControlBandInLine1Out has value manual(1), the value is equal to that of tnVwmMsPmudEVoaBandInLine1Out. When tnVwmMsPmudEVoaControlBandInLine1Out has value auto(2), the value is determined by the eVoa Control Loop.
TropicVwmMsSignalAttenuation