OID .1
BRANCH
1.3.6.1.4.1.7777.1.1
Description
No DESCRIPTION clause found for this object.
Children (203)
.1phase_shift_between_normal_and_emergency.2normal_frequency.3emergency_frequency.4main_on_normal.5main_on_emergency.6auxiliary_on_normal.7auxiliary_on_emergency.8normal_source_available.9emergency_source_available.10engine_exerciser_with_load_active.11external_f17_is_active.12normal_voltage_phase_AB.13normal_voltage_phase_BC.14normal_voltage_phase_CA.15normal_voltage_unbalance.18emergency_voltage_phase_CA.19nominal_voltage.20nominal_frequency.21normal_source_3phase_sensing.22transfer_switch_type.23transfer_switch_ampere_rating.24controller_software_version.25controller_software_date.26external_parameter_lock_is_active.27engine_running.28controller_state.29controller_status_state_data.30timer_bypass_feature_6B_status.31remote_transfer_feature_17_status.32load_shed_feature_30_status.33transfer_inhibit_to_emergency_feature_34B_status.34local_test_feature_5_status.35manual_transfer_to_emergency_feature_6ZE_status.36current_sensing.37phase_A_current.38phase_B_current.39phase_C_current.40failure_to_accept_timer.41normal_to_emergency_pretransfer_time_delay_feature_31_bypass_enabled.42emergency_to_normal_pretransfer_time_delay_feature_31_bypass_enabled.43commit_to_transfer_enabled.44bypass_DTTS_source_failure_enabled.45inphase_transfer_enabled.46inphase_monitor_for_load_shed_feature_30_enabled.47fail_accept_timer_enabled.48transfer_retransfer_time_delay_bypass_feature_6B_input_enabled.49remote_transfer_feature_17_input_enabled.50retransfer_to_normal_mode_selector_feature_6DL_input_enabled.51serial_remote_transfer_feature_17_enabled.52voltage_unbalance_enabled.53current_sensing_module_present.54alert_LED_active.55not_in_auto_LED_active.58daylight_savings.59loss_of_emergency_when_connected_to_emergency_alarm_enabled.60expiration_of_failure_to_accept_timer_alarm_enabled.61load_disconnect_enabled_DTTS_only.62op1_is_feature_31.63op1_is_common_alarm.64op1_is_NR2.65op1_is_not_in_auto.66op2_is_feature_31.67op2_is_common_alarm.68op2_is_NR2.69op2_is_not_in_auto.70op2_1G_enabled.71op3_is_feature_31.72op3_is_common_alarm.73op3_is_NR2.74op3_is_not_in_auto.75controller_serial_number.76engine_exerciser_F11C_advanced_program_number.77engine_exerciser_F11C_enabled.78engine_exerciser_F11C_test_with_load_transfer_enabled.79engine_exerciser_F11C_start_week.80engine_exerciser_F11C_day_of_week.82engine_exerciser_F11C_start_time_hours.83engine_exerciser_F11C_start_time_minutes.84engine_exerciser_F11C_run_time_hours.85engine_exerciser_F11C_run_time_minutes.86normal_voltage_dropout.87normal_voltage_pickup.88normal_over_voltage_trip.89normal_frequency_dropout.90normal_frequency_pickup.91normal_over_frequency_trip.92emergency_voltage_dropout.93emergency_voltage_pickup.94emergency_over_voltage_trip.95emergency_frequency_dropout.96emergency_frequency_pickup.97emergency_over_frequency_trip.98timer_1C_engine_start_time_delay.99timer_1F_engine_fail_time_delay.100timer_2B_transfer_N_to_E_time_delay.101timer_2E_engine_cool_down_time_delay.102timer_3AF_transfer_E_to_N_on_source_fail_time_delay.103timer_3A_T_transfer_E_to_N_on_test_time_delay.104timer_31F_N_to_E_pre_transfer_signal_time_delay.105timer_31M_N_to_E_post_transfer_signal_time_delay.106timer_31G_E_to_N_pre_transfer_signal_time_delay.107timer_31N_E_to_N_post_transfer_signal_time_delay.108dtts_load_disconnect_time_delay.109commit_to_transfer_after_engine_start.110real_time_hour.111real_time_minute.112real_time_second.113calendar_year.114calendar_month.115calendar_day_of_month.116calendar_day_of_week.117total_time_E_has_been_acceptable_high_word.118total_time_E_has_been_acceptable_low_word.119total_time_N_has_been_acceptable_high_word.120total_time_N_has_been_acceptable_low_word.121total_number_of_days_CP_has_been_energized.122total_number_of_TS_transfers.123total_number_of_TS_transfers_due_to_source_failures.124controller_location.125external_feature_5_enabled.126external_feature_34_enabled.127inphase_filter_enabled.128current_sensing_option_installed.129advanced_11C_option_installed.130event_log_option_installed.131rs485_communication_option_installed.132op1_common_alarm_option_installed.133total_time_load_connected_to_normal_high_word.134total_time_load_connected_to_normal_low_word.135total_time_load_connected_to_emergency_high_word.136total_time_load_connected_to_emergency_low_word.137rs485_port_address.138rs485_port_baud_rate.139rs485_port_protocol.140emulate_group_1.141dtts_load_disconnect_recovery_mode_manual_or_auto.142timer_2B_transfer_N_to_E_on_test_time_delay.143inphase_monitor_time_delay.144ats_total_transfer_time_in_10th_seconds.145dongle_installed.146language_selection_setting.147lcd_contrast_setting.148controller_name.149boot_loader_version.150voltage_display_phase_label_selection.151source_1_or_source_2_selection_for_different_english_format.152external_battery_enabled.153ts_data_gen_start_date.154ts_data_gen_start_month.155ts_data_gen_start_year.156ts_data_gen_start_hour.157ts_data_gen_start_minutes.158ts_data_gen_start_seconds.159ts_data_gen_start_10th_of_seconds.160ts_data_gen_start_elapsed_time_in_seconds.161total_active_alarm_number.162load_shed_direction.163dtts_only_load_shed_on_source_failure.164dtts_only_load_shed_on_request_f17.165normal_voltage_unbalance_dropout.166normal_voltage_unbalance_pickup.167emergency_voltage_unbalance_dropout.168emergency_voltage_unbalance_pickup.169emergency_voltage_phase_ab.170emergency_voltage_phase_bc.171emergency_voltage_unbalance.172emergency_source_3phase_sensing.173transfer_switch_bypass_or_not.174transfer_switch_or_dual_breaker.175transfer_switch_locked_out.176ctts_extended_parallel_alarm.177ctts_failure_to_synch_alarm.178dtts_load_disconnect.179normal_breaker_tripped.180emergency_breaker_tripped.181feature_6b.182feature_6c.183feature_17_serial.184feature_29.185feature_34a.186feature_89.187feature_ct_bypass.188feature_alarm_reset.189feature_6d.190feature_34t.191control_panel_eventlog_enabled.192pt_ratio_numerator.193pt_ratio_denominator.194control_panel_name.195normal_voltage_unbalance_enabled.196emergency_voltage_unbalance_enabled.197bypass_31F_and_31M_on_N_source_failure.198bypass_31G_and_31N_on_E_source_failure.199external_battery_present.200ctts_in_synch_monitor_time_delay.201ctts_fail_to_synch_time_delay.202ctts_extended_parallel_time_delay.203shed_load_in_phase.204isolate_load_on_source_failure.205isolate_load_on_F17.206fail_to_sync_auto_ct_bypass.207transfer_in_phase_on_ct_bypass_if_load_disconnect.208network_configuration