MIB Viewer

vRtrPimNgIfHelloMultiplier

OBJECT-TYPE
1.3.6.1.4.1.6527.3.1.2.50.2.2.1.10
Access
read-create
Status
current
Sub-identifiers
0
The value of vRtrPimNgIfHelloMultiplier specifies the multiplier for determining the holdtime for a PIM neighbor on this interface. The hello-multiplier in conjunction with the hello-interval will determine the holdtime for a PIM neighbor. The formula used to calculate the hello-holdtime based on the hello-multiplier is - (hello-interval * hello-multiplier) / 10 The hello-multiplier is specified in multiples of 0.1. This allows the PIMv2 default timeout of 3.5 seconds to be supported.
Unsigned32 (20..100)