MIB Viewer

vmwNsxTAlarmManagementAlarmServiceOverloaded

NOTIFICATION-TYPE
1.3.6.1.4.1.6876.120.1.0.16.0.1
Status
current
Sub-identifiers
0
Due to heavy volume of alarms reported, the alarm service is temporarily overloaded. The NSX UI and GET /api/v1/alarms NSX API have stopped reporting new alarms; however, syslog entries and SNMP traps (if enabled) are still being emitted reporting the underlying event details. When the underlying issues causing the heavy volume of alarms are addressed, the alarm service will start reporting new alarms again. Action required: Review all active alarms using the Alarms page in the NSX UI or using the GET /api/v1/alarms?status=OPEN,ACKNOWLEDGED,SUPPRESSED NSX API. For each active alarm investigate the root cause by following the recommended action for the alarm. When sufficient alarms are resolved, the alarm service will start reporting new alarms again.