MIB Viewer

wanT3E3StatsLOSs

OBJECT-TYPE
1.3.6.1.4.1.11.2.3.7.6.1.5.1.8.1.1.4.1.22
Access
read-only
Status
current
Sub-identifiers
0
The DS3 LOS defect is declared upon observing 175 +/- 75 contiguous pulse positions with no pulses of either positive or negative polarity. The DS3 LOS defect is terminated upon observing an average pulse density of at least 33% over a period of 175 +/- 75 contiguous pulse positions starting with the receipt of a pulse.
Counter64