Total Access 5000 Fan Module MIB
OIDNameAccessStatusDescription
1.3.6.1.4.1.664.1.751NodeadTA5kFanModule
1.3.6.1.4.1.664.1.751.0NodeadTa5kFanModuleEvents
1.3.6.1.4.1.664.1.751.0.1NotificationadTA5kFanYellowActivecurrentThis trap indicates a yellow alarm meaning 1 fan alarming.
1.3.6.1.4.1.664.1.751.0.2NotificationadTA5kFanYellowInActivecurrentThis trap indicates a yellow alarm inactive meaning 1 fan no longer alarming.
1.3.6.1.4.1.664.1.751.0.3NotificationadTA5kFanRedActivecurrentThis trap indicates a red alarm meaning multiple fans alarming.
1.3.6.1.4.1.664.1.751.0.4NotificationadTA5kFanRedInActivecurrentThis trap indicates a red alarm inactive meaning multiple fans no longer alarming.
1.3.6.1.4.1.664.1.751.0.5NotificationadTA5kFanTempThresExceedActivecurrentThis trap indicates a fan temperature threshold alarm.
1.3.6.1.4.1.664.1.751.0.6NotificationadTA5kFanTempThresExceedInactivecurrentThis trap indicates a fan temperature threshold alarm inactive.
1.3.6.1.4.1.664.1.860NodeadTA5kFanModule19
1.3.6.1.4.1.664.2.751NodeadTA5kFanmg
1.3.6.1.4.1.664.2.751.1NodeadTA5kFanProvisioning
1.3.6.1.4.1.664.2.751.1.1TableadTA5kFanProvTablenot-accessiblecurrentTable of Fan Module provisioning info.
1.3.6.1.4.1.664.2.751.1.1.1RowadTA5kFanProvEntrynot-accessiblecurrentIndexed by slot number
1.3.6.1.4.1.664.2.751.1.1.1.1ColumnadTA5kFanProvFanSpeedModeread-writecurrentThe speed mode of auto causes the fans to be thermostatically controlled. The speed mode of max causes the fans to run at max speed continuously.
1.3.6.1.4.1.664.2.751.1.1.1.2ColumnadTA5kFanProvTempThresread-writecurrentReprsents the temperature threhold for the fan sensor in deg C with a whole number range of 1 - 999.
1.3.6.1.4.1.664.2.751.1.1.1.3ColumnadTA5kFanProvYellowAlarmEnableread-writecurrentTrue - alarm is enabled
1.3.6.1.4.1.664.2.751.1.1.1.4ColumnadTA5kFanProvRedAlarmEnableread-writecurrentTrue - alarm is enabled
1.3.6.1.4.1.664.2.751.1.1.1.5ColumnadMultiFanAlarmSeverityread-writecurrentSets the Severity for the Multi-Fan alarm
1.3.6.1.4.1.664.2.751.1.1.1.6ColumnadFanTempThreshAlarmSeverityread-writecurrentSets the Severity for the Fan Temperature Threshold alarm
1.3.6.1.4.1.664.2.751.2NodeadTA5kFanStatus
1.3.6.1.4.1.664.2.751.2.1TableadTA5kFanStatusTablenot-accessiblecurrentTable of GR-303 Interface group info.
1.3.6.1.4.1.664.2.751.2.1.1RowadTA5kFanStatusEntrynot-accessiblecurrentIndexed by slot number
1.3.6.1.4.1.664.2.751.2.1.1.1ColumnadTA5kFanStatusFan1Speedread-onlycurrentThe speed of Fan1 including units (RPM)
1.3.6.1.4.1.664.2.751.2.1.1.2ColumnadTA5kFanStatusFan2Speedread-onlycurrentThe speed of Fan2 including units (RPM)
1.3.6.1.4.1.664.2.751.2.1.1.3ColumnadTA5kFanStatusFan3Speedread-onlycurrentThe speed of Fan3 including units (RPM)
1.3.6.1.4.1.664.2.751.2.1.1.4ColumnadTA5kFanStatusFan4Speedread-onlycurrentThe speed of Fan4 including units (RPM)
1.3.6.1.4.1.664.2.751.2.1.1.5ColumnadTA5kFanStatusVoltageread-onlycurrentThe shelf voltage including units (V)
1.3.6.1.4.1.664.2.751.2.1.1.6ColumnadTA5kFanStatusTempread-onlycurrentThe module temperature including units (C)
1.3.6.1.4.1.664.2.751.2.1.1.7ColumnadTA5kFanStatusVoltageAuxread-onlycurrentThe aux shelf voltage for high flow fan including units (V)
1.3.6.1.4.1.664.2.751.2.1.1.8ColumnadTA5kFanStatusFan5Speedread-onlycurrentThe speed of Fan5 (high flow) including units (RPM)
1.3.6.1.4.1.664.2.751.2.1.1.9ColumnadTA5kFanStatusFan6Speedread-onlycurrentThe speed of Fan6 (high flow) including units (RPM)
1.3.6.1.4.1.664.2.751.2.1.1.10ColumnadTA5kFanStatusFan7Speedread-onlycurrentThe speed of Fan7 (high flow) including units (RPM)
1.3.6.1.4.1.664.2.751.2.1.1.11ColumnadTA5kFanStatusFan8Speedread-onlycurrentThe speed of Fan8 (high flow) including units (RPM)
1.3.6.1.4.1.664.2.751.2.1.1.12ColumnadTA5kMultiFansInAlarmread-onlycurrentThe number of fans in alarm
1.3.6.1.4.1.664.6.751IdentityadTa5kFanModuleIdentityTotal Access 5000 Fan Module MIB