This document is the SNMP MIB module to manage and provision the microwave components on the Nokia 7xxx device. Copyright 2010-2014 Nokia. All rights reserved. Reproduction of this document is authorized on the condition that the foregoing copyright notice is included. This SNMP MIB module (Specification) embodies Nokia's proprietary intellectual property. Nokia retains all title and ownership in the Specification, including any revisions. Nokia grants all interested parties a non-exclusive license to use and distribute an unmodified copy of this Specification in connection with management of Nokia products, and without fee, provided this copyright notice and license appear on all copies. This Specification is supplied 'as is', and Nokia makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification.
OIDNameAccessStatusDescription
1.3.6.1.4.1.6527.6.1.1.1.3.11IdentityaluRMMIBModuleThis document is the SNMP MIB module to manage and provision the microwave components on the Nokia 7xxx device. Copyright 2010-2014 Nokia. All rights reserved.…
1.3.6.1.4.1.6527.6.1.2.1.11NodealuRMMIBConformance
1.3.6.1.4.1.6527.6.1.2.1.11.11NodealuRMConformance
1.3.6.1.4.1.6527.6.1.2.1.11.11.1NodealuRMCompliances
1.3.6.1.4.1.6527.6.1.2.1.11.11.1.1NodealuRMComp7705
1.3.6.1.4.1.6527.6.1.2.1.11.11.1.1.1CompliancealuRMComp7705V1v0currentThe compliance statement for revision 1.0 of ALU-REMOTE-MONITORING-MIB.
1.3.6.1.4.1.6527.6.1.2.1.11.11.2NodealuRMGroups
1.3.6.1.4.1.6527.6.1.2.1.11.11.2.1GroupaluRMGroupcurrentThe group of objects supporting management of the Remote Site Monitoring and Control on Nokia SAR series systems.
1.3.6.1.4.1.6527.6.1.2.1.11.11.2.2GroupaluRMNotificationGroupcurrentThe group of notifications supporting the management of Remote Site Monitoring and Conrol on Nokia SAR series systems.
1.3.6.1.4.1.6527.6.1.2.1.11.11.2.3GroupaluRMNotificationObjsGroupcurrentThe group of notifications objs supporting the management of Remote Site Monitoring and Conrol on Nokia SAR series systems.
1.3.6.1.4.1.6527.6.1.2.1.11.11.2.4GroupaluRMDigitalGroupcurrentThe group of objects supporting the management of Remote Site Monitoring and Conrol on Digital Inputs for Nokia SAR series systems.
1.3.6.1.4.1.6527.6.1.2.1.11.11.2.5GroupaluRMAuxTriggerGroupcurrentThe group of objects supporting management of the Auxilary Monitoring and Control on Nokia SAR series systems.
1.3.6.1.4.1.6527.6.1.2.2.11NodealuRMObjPrefix
1.3.6.1.4.1.6527.6.1.2.2.11.1NodealuRMObjs
1.3.6.1.4.1.6527.6.1.2.2.11.1.1TablealuRMTriggerTablenot-accessiblecurrentThe aluRMTriggerTable has an entry for each provisioned external alarm input in the system that that may be used to monitor remote-site equipment.
1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1RowaluRMTriggerEntrynot-accessiblecurrentEach row entry represents a external alarm trigger. Rows are created and destroyed based on the provisioned hardware in the system that is equipped with input …
1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.1ColumnaluRMTriggerIDnot-accessiblecurrentaluRMTriggerID identifies the Remote Site Monitoring trigger. The value of this object is calculated using the TiMOS encoding scheme described in AluRMExtAlarm…
1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.2ColumnaluRMTriggerNameread-onlycurrentThe textual name of the trigger. The value of this object should be the name of the trigger as assigned by the local device and should be suitable for use in c…
1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.3ColumnaluRMTriggerAdminStatusread-writecurrentaluRMTriggerAdminStatus specifies whether monitoring is enabled or disabled on this trigger.
1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.4ColumnaluRMTriggerOperStatusread-onlycurrentaluRMTriggerOperStatus indicates the current operational alarm status of the trigger.
1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.5ColumnaluRMTriggerDescriptionread-writecurrentA textual string containing user supplied information about the trigger.
1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.6ColumnaluRMTriggerDetectDebounceread-writecurrentaluRMTriggerDetectDebounce specifies the amount of time to debounce the reporting of the triggers. This guards against excessive reporting of trigger transitio…
1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.7ColumnaluRMTriggerClearDebounceread-writecurrentaluRMTriggerClearDebounce specifies the amount of time to debounce the reporting of the triggers. This guards against excessive reporting of trigger transition…
1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.8ColumnaluRMTriggerAnalogVoltageread-onlycurrentaluRMTriggerAnalogVoltage indicates the current voltage on analog triggers.
1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.9ColumnaluRMTriggerDigitalStateread-onlycurrentaluRMTriggerDigitalState indicates the current contact state on digital triggers.
1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.10ColumnaluRMTriggerAliasread-writecurrentaluRMTriggerAlias is a unique name that identifies the trigger.
1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.11ColumnaluRMTriggerDigitalNormread-writecurrentaluRMTriggerDigitalNorm indicates the normal contact state of digital triggers.
1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.12ColumnaluRMTriggerRowStatusread-writecurrentaluRMTriggerRowStatus specifies the status of this row. Only auxilary alarm triggers (Ports.. etc) can be created and destroyed.
1.3.6.1.4.1.6527.6.1.2.2.11.1.2TablealuRMRelayTablenot-accessiblecurrentThe aluRMRelayTable has an entry for each provisioned output relay connector in the system that that may be used to control remote-site equipment.
1.3.6.1.4.1.6527.6.1.2.2.11.1.2.1RowaluRMRelayEntrynot-accessiblecurrentEach row entry represents a remote-monitoring output relay. Rows are created and destroyed based on the provisioned hardware in the system that is equipped wit…
1.3.6.1.4.1.6527.6.1.2.2.11.1.2.1.1ColumnaluRMRelayIDnot-accessiblecurrentaluRMRelayID identifies an output relay. The value of this object is calculated using the TiMOS encoding scheme described in AluRMExtAlarmID.
1.3.6.1.4.1.6527.6.1.2.2.11.1.2.1.2ColumnaluRMRelayNameread-onlycurrentThe textual name of the relay. The value of this object should be the name of the relay as assigned by the local device and should be suitable for use in comma…
1.3.6.1.4.1.6527.6.1.2.2.11.1.2.1.3ColumnaluRMRelayModeread-writecurrentaluRMRelayMode specifies the mode that the relay will operate in. When a relay is in 'continuous' mode it will be always active when it is not administratively…
1.3.6.1.4.1.6527.6.1.2.2.11.1.2.1.4ColumnaluRMRelayAdminStatusread-writecurrentaluRMRelayAdminStatus specifies the administrative status of this relay.
1.3.6.1.4.1.6527.6.1.2.2.11.1.2.1.5ColumnaluRMRelayOperStatusread-onlycurrentaluRMRelayOperStatus indicates the current operational alarm status of the relay.
1.3.6.1.4.1.6527.6.1.2.2.11.1.2.1.6ColumnaluRMRelayDescriptionread-writecurrentA textual string containing user supplied information about the relay.
1.3.6.1.4.1.6527.6.1.2.2.11.1.2.1.7ColumnaluRMRelayAliasread-writecurrentaluRMRelayAlias is a unique name that identifies the relay.
1.3.6.1.4.1.6527.6.1.2.2.11.1.3TablealuRMAlarmTablenot-accessiblecurrentThe aluRMAlarmTable contains information about each Alarm condition being monitored by Remote Site Monitoring.
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1RowaluRMAlarmEntrynot-accessiblecurrentEach row entry represents a Remote Site Monitoring Alarm.
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.1ColumnaluRMAlarmIDnot-accessiblecurrentaluRMAlarmID identifies the Remote Site Monitoring Alarm.
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.2ColumnaluRMAlarmRowStatusread-createcurrentaluRMAlarmRowStatus specifies the status of this row. To delete an entry from this table, the alarm must be adminstatively disabled.
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.3ColumnaluRMAlarmAdminStatusread-createcurrentaluRMAlarmAdminStatus specifies the administrative status of this alarm.
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.4ColumnaluRMAlarmOperStatusread-onlycurrentaluRMAlarmOperStatus indicates the current operational status of the alarm.
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.5ColumnaluRMAlarmDescriptionread-createcurrentA textual string containing user supplied information about the alarm. This description is used as part of the log event generated by the
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.6ColumnaluRMAlarmTriggerRuleread-createcurrentaluRMAlarmTriggerRule specifies the rule used by Remote-Monitoring to determine if the criteria has been met to raise or clear this alarm. A value of 'any-trig…
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.7ColumnaluRMAlarmTrigger1read-createcurrentaluRMAlarmTrigger1 identifies a trigger for this alarm.
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.8ColumnaluRMAlarmTrigger2read-createcurrentaluRMAlarmTrigger2 identifies a trigger for this alarm.
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.9ColumnaluRMAlarmTrigger3read-createcurrentaluRMAlarmTrigger3 identifies a trigger for this alarm.
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.10ColumnaluRMAlarmTrigger4read-createcurrentaluRMAlarmTrigger4 identifies a trigger for this alarm.
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.11ColumnaluRMAlarmTrigger5read-createcurrentaluRMAlarmTrigger5 identifies a trigger for this alarm.
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.12ColumnaluRMAlarmTrigger6read-createcurrentaluRMAlarmTrigger6 identifies a trigger for this alarm.
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.13ColumnaluRMAlarmTrigger7read-createcurrentaluRMAlarmTrigger7 identifies a trigger for this alarm.
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.14ColumnaluRMAlarmTrigger8read-createcurrentaluRMAlarmTrigger8 identifies a trigger for this alarm.
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.15ColumnaluRMAlarmSeverityread-createcurrentaluRMAlarmSeverity specifies the severity of this alarm.
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.16ColumnaluRMAlarmActionLogread-createcurrentaluRMAlarmActionLog specifies if a log event is generated as a result of this alarm.
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.17ColumnaluRMAlarmActionAlarmRelayread-createcurrentaluRMAlarmActionAlarmRelay specifies if the alarm LEDs and alarm output relays located on the chassis are updated as a result of this alarm.
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.18ColumnaluRMAlarmActionAuxRelayread-createcurrentaluRMAlarmActionAuxRelay specifies if an auxiliary alarm relay is triggered/controlled as a result of this alarm. This object must be set with aluRMAlarmAuxRel…
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.19ColumnaluRMAlarmAuxRelayread-createcurrentaluRMAlarmAuxRelay identifies the relay that is triggered/ controlled by this alarm when aluRMAlarmActionAuxRelay is set to 'true'.
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.20ColumnaluRMAlarmDetectedTriggersread-onlycurrentaluRMAlarmDetectedTriggers is a bitmask that identifies the currently detected triggers on this alarm. The bitmask is based on the trigger index assigned.
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.21ColumnaluRMAlarmTHAnalogLevelOperationread-createcurrentaluRMAlarmTHAnalogLevelOperation indicates the operation to be performed to determine if aluRMAlarmTHAnalogLevel is crossed. The operation can not be 'not-moni…
1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.22ColumnaluRMAlarmTHAnalogLevelread-createcurrentaluRMAlarmTHAnalogLevel indicates the analog voltage threshold of all analog triggers of this alarm.
1.3.6.1.4.1.6527.6.1.2.2.11.2NodealuRMNotifyObjs
1.3.6.1.4.1.6527.6.1.2.2.11.2.1ScalaraluRMAlarmNotifyIDaccessible-for-notifycurrentUsed by RM Alarm Notifications, the OID indicates the alarm identifier.
1.3.6.1.4.1.6527.6.1.2.2.11.2.2ScalaraluRMAlarmNotifyDescriptionaccessible-for-notifycurrentA textual string containing user supplied information about the alarm.
1.3.6.1.4.1.6527.6.1.2.2.11.2.3ScalaraluRMNotifyIDaccessible-for-notifycurrentUsed by RM Oper Notifications, the OID indicates the trigger or relay identifier.
1.3.6.1.4.1.6527.6.1.2.2.11.2.4ScalaraluRMNotifyOperStateaccessible-for-notifycurrentUsed by RM Oper Notifications, the OID indicates the trigger or relay oper state.
1.3.6.1.4.1.6527.6.1.2.3.7NodealuRMNotifyPrefix
1.3.6.1.4.1.6527.6.1.2.3.7.0NodealuRMNotification
1.3.6.1.4.1.6527.6.1.2.3.7.0.1NotificationaluRMCriticalAlarmcurrentGenerated when remote-monitoring detects a change for a critical alarm.
1.3.6.1.4.1.6527.6.1.2.3.7.0.2NotificationaluRMMajorAlarmcurrentGenerated when remote-monitoring detects a change for a major alarm.
1.3.6.1.4.1.6527.6.1.2.3.7.0.3NotificationaluRMMinorAlarmcurrentGenerated when remote-monitoring detects a change for a minor alarm.
1.3.6.1.4.1.6527.6.1.2.3.7.0.4NotificationaluRMWarningAlarmcurrentGenerated when remote-monitoring detects a change for a warning alarm.
1.3.6.1.4.1.6527.6.1.2.3.7.0.5NotificationaluRMClearingAlarmcurrentGenerated when remote-monitoring detects the clearing of an alarm.
1.3.6.1.4.1.6527.6.1.2.3.7.0.6NotificationaluRMOperStateUpdatecurrentGenerated when triggers or relays change operational state.
Type Definitions
NameSyntaxStatusDescription
AluRMAdminStatusINTEGER { unknown (0), disabled (1), enabled (2) }currentThe administrative status of monitoring.
AluRMAliasDisplayString (SIZE(0..15))currentUnique alias name of a remote site alarm object. Note, use only NVT ASCII displayable characters here, no control characters, no UTF-8, etc.
AluRMExtAlarmIDUnsigned32currentAn AluRMExtAlarmID is a unique 32 bit number that represents a physical alarm-connector equipped on an auxiliary alarm module. This connector can be used for monitoring and management of remote site and devices. Encoded…
AluRMOperStatusINTEGER { unknown (0), ghost (1), not-monitored (2), ok (3), active (4) }currentThe operational status of monitoring. unknown - the current status is not known ghost - associated hardware is not present or offline not-monitored - monitoring is disabled ok - alarm state is ok active - alarm detected