ALU-REMOTE-MONITORING-MIB
78 objects
This document is the SNMP MIB module to manage and provision the microwave components on the Nokia 7xxx device. Copyright 2010-2014 Nokia. All rights reserved. Reproduction of this document is authorized on the condition that the foregoing copyright notice is included. This SNMP MIB module (Specification) embodies Nokia's proprietary intellectual property. Nokia retains all title and ownership in the Specification, including any revisions. Nokia grants all interested parties a non-exclusive license to use and distribute an unmodified copy of this Specification in connection with management of Nokia products, and without fee, provided this copyright notice and license appear on all copies. This Specification is supplied 'as is', and Nokia makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification.
Imported Objects
| ALU-SAR-GLOBAL-MIB | aluSARConfs aluSARMIBModules aluSARNotifyPrefix aluSARObjs |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Counter64 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString RowStatus TEXTUAL-CONVENTION TimeStamp TruthValue |
| TIMETRA-CHASSIS-MIB | tmnxChassisIndex |
| TIMETRA-TC-MIB | TItemLongDescription TNamedItemOrEmpty |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.6527.6.1.1.1.3.11 | IdentityaluRMMIBModule | This document is the SNMP MIB module to manage and provision the microwave components on the Nokia 7xxx device. Copyright 2010-2014 Nokia. All rights reserved.… | ||
| 1.3.6.1.4.1.6527.6.1.2.1.11 | NodealuRMMIBConformance | |||
| 1.3.6.1.4.1.6527.6.1.2.1.11.11 | NodealuRMConformance | |||
| 1.3.6.1.4.1.6527.6.1.2.1.11.11.1 | NodealuRMCompliances | |||
| 1.3.6.1.4.1.6527.6.1.2.1.11.11.1.1 | NodealuRMComp7705 | |||
| 1.3.6.1.4.1.6527.6.1.2.1.11.11.1.1.1 | CompliancealuRMComp7705V1v0 | current | The compliance statement for revision 1.0 of ALU-REMOTE-MONITORING-MIB. | |
| 1.3.6.1.4.1.6527.6.1.2.1.11.11.2 | NodealuRMGroups | |||
| 1.3.6.1.4.1.6527.6.1.2.1.11.11.2.1 | GroupaluRMGroup | current | The group of objects supporting management of the Remote Site Monitoring and Control on Nokia SAR series systems. | |
| 1.3.6.1.4.1.6527.6.1.2.1.11.11.2.2 | GroupaluRMNotificationGroup | current | The group of notifications supporting the management of Remote Site Monitoring and Conrol on Nokia SAR series systems. | |
| 1.3.6.1.4.1.6527.6.1.2.1.11.11.2.3 | GroupaluRMNotificationObjsGroup | current | The group of notifications objs supporting the management of Remote Site Monitoring and Conrol on Nokia SAR series systems. | |
| 1.3.6.1.4.1.6527.6.1.2.1.11.11.2.4 | GroupaluRMDigitalGroup | current | The group of objects supporting the management of Remote Site Monitoring and Conrol on Digital Inputs for Nokia SAR series systems. | |
| 1.3.6.1.4.1.6527.6.1.2.1.11.11.2.5 | GroupaluRMAuxTriggerGroup | current | The group of objects supporting management of the Auxilary Monitoring and Control on Nokia SAR series systems. | |
| 1.3.6.1.4.1.6527.6.1.2.2.11 | NodealuRMObjPrefix | |||
| 1.3.6.1.4.1.6527.6.1.2.2.11.1 | NodealuRMObjs | |||
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.1 | TablealuRMTriggerTable | not-accessible | current | The aluRMTriggerTable has an entry for each provisioned external alarm input in the system that that may be used to monitor remote-site equipment. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1 | RowaluRMTriggerEntry | not-accessible | current | Each row entry represents a external alarm trigger. Rows are created and destroyed based on the provisioned hardware in the system that is equipped with input … |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.1 | ColumnaluRMTriggerID | not-accessible | current | aluRMTriggerID identifies the Remote Site Monitoring trigger. The value of this object is calculated using the TiMOS encoding scheme described in AluRMExtAlarm… |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.2 | ColumnaluRMTriggerName | read-only | current | The textual name of the trigger. The value of this object should be the name of the trigger as assigned by the local device and should be suitable for use in c… |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.3 | ColumnaluRMTriggerAdminStatus | read-write | current | aluRMTriggerAdminStatus specifies whether monitoring is enabled or disabled on this trigger. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.4 | ColumnaluRMTriggerOperStatus | read-only | current | aluRMTriggerOperStatus indicates the current operational alarm status of the trigger. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.5 | ColumnaluRMTriggerDescription | read-write | current | A textual string containing user supplied information about the trigger. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.6 | ColumnaluRMTriggerDetectDebounce | read-write | current | aluRMTriggerDetectDebounce specifies the amount of time to debounce the reporting of the triggers. This guards against excessive reporting of trigger transitio… |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.7 | ColumnaluRMTriggerClearDebounce | read-write | current | aluRMTriggerClearDebounce specifies the amount of time to debounce the reporting of the triggers. This guards against excessive reporting of trigger transition… |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.8 | ColumnaluRMTriggerAnalogVoltage | read-only | current | aluRMTriggerAnalogVoltage indicates the current voltage on analog triggers. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.9 | ColumnaluRMTriggerDigitalState | read-only | current | aluRMTriggerDigitalState indicates the current contact state on digital triggers. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.10 | ColumnaluRMTriggerAlias | read-write | current | aluRMTriggerAlias is a unique name that identifies the trigger. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.11 | ColumnaluRMTriggerDigitalNorm | read-write | current | aluRMTriggerDigitalNorm indicates the normal contact state of digital triggers. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.1.1.12 | ColumnaluRMTriggerRowStatus | read-write | current | aluRMTriggerRowStatus specifies the status of this row. Only auxilary alarm triggers (Ports.. etc) can be created and destroyed. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.2 | TablealuRMRelayTable | not-accessible | current | The aluRMRelayTable has an entry for each provisioned output relay connector in the system that that may be used to control remote-site equipment. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.2.1 | RowaluRMRelayEntry | not-accessible | current | Each row entry represents a remote-monitoring output relay. Rows are created and destroyed based on the provisioned hardware in the system that is equipped wit… |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.2.1.1 | ColumnaluRMRelayID | not-accessible | current | aluRMRelayID identifies an output relay. The value of this object is calculated using the TiMOS encoding scheme described in AluRMExtAlarmID. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.2.1.2 | ColumnaluRMRelayName | read-only | current | The textual name of the relay. The value of this object should be the name of the relay as assigned by the local device and should be suitable for use in comma… |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.2.1.3 | ColumnaluRMRelayMode | read-write | current | aluRMRelayMode specifies the mode that the relay will operate in. When a relay is in 'continuous' mode it will be always active when it is not administratively… |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.2.1.4 | ColumnaluRMRelayAdminStatus | read-write | current | aluRMRelayAdminStatus specifies the administrative status of this relay. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.2.1.5 | ColumnaluRMRelayOperStatus | read-only | current | aluRMRelayOperStatus indicates the current operational alarm status of the relay. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.2.1.6 | ColumnaluRMRelayDescription | read-write | current | A textual string containing user supplied information about the relay. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.2.1.7 | ColumnaluRMRelayAlias | read-write | current | aluRMRelayAlias is a unique name that identifies the relay. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3 | TablealuRMAlarmTable | not-accessible | current | The aluRMAlarmTable contains information about each Alarm condition being monitored by Remote Site Monitoring. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1 | RowaluRMAlarmEntry | not-accessible | current | Each row entry represents a Remote Site Monitoring Alarm. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.1 | ColumnaluRMAlarmID | not-accessible | current | aluRMAlarmID identifies the Remote Site Monitoring Alarm. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.2 | ColumnaluRMAlarmRowStatus | read-create | current | aluRMAlarmRowStatus specifies the status of this row. To delete an entry from this table, the alarm must be adminstatively disabled. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.3 | ColumnaluRMAlarmAdminStatus | read-create | current | aluRMAlarmAdminStatus specifies the administrative status of this alarm. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.4 | ColumnaluRMAlarmOperStatus | read-only | current | aluRMAlarmOperStatus indicates the current operational status of the alarm. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.5 | ColumnaluRMAlarmDescription | read-create | current | A textual string containing user supplied information about the alarm. This description is used as part of the log event generated by the |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.6 | ColumnaluRMAlarmTriggerRule | read-create | current | aluRMAlarmTriggerRule specifies the rule used by Remote-Monitoring to determine if the criteria has been met to raise or clear this alarm. A value of 'any-trig… |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.7 | ColumnaluRMAlarmTrigger1 | read-create | current | aluRMAlarmTrigger1 identifies a trigger for this alarm. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.8 | ColumnaluRMAlarmTrigger2 | read-create | current | aluRMAlarmTrigger2 identifies a trigger for this alarm. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.9 | ColumnaluRMAlarmTrigger3 | read-create | current | aluRMAlarmTrigger3 identifies a trigger for this alarm. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.10 | ColumnaluRMAlarmTrigger4 | read-create | current | aluRMAlarmTrigger4 identifies a trigger for this alarm. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.11 | ColumnaluRMAlarmTrigger5 | read-create | current | aluRMAlarmTrigger5 identifies a trigger for this alarm. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.12 | ColumnaluRMAlarmTrigger6 | read-create | current | aluRMAlarmTrigger6 identifies a trigger for this alarm. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.13 | ColumnaluRMAlarmTrigger7 | read-create | current | aluRMAlarmTrigger7 identifies a trigger for this alarm. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.14 | ColumnaluRMAlarmTrigger8 | read-create | current | aluRMAlarmTrigger8 identifies a trigger for this alarm. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.15 | ColumnaluRMAlarmSeverity | read-create | current | aluRMAlarmSeverity specifies the severity of this alarm. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.16 | ColumnaluRMAlarmActionLog | read-create | current | aluRMAlarmActionLog specifies if a log event is generated as a result of this alarm. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.17 | ColumnaluRMAlarmActionAlarmRelay | read-create | current | aluRMAlarmActionAlarmRelay specifies if the alarm LEDs and alarm output relays located on the chassis are updated as a result of this alarm. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.18 | ColumnaluRMAlarmActionAuxRelay | read-create | current | aluRMAlarmActionAuxRelay specifies if an auxiliary alarm relay is triggered/controlled as a result of this alarm. This object must be set with aluRMAlarmAuxRel… |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.19 | ColumnaluRMAlarmAuxRelay | read-create | current | aluRMAlarmAuxRelay identifies the relay that is triggered/ controlled by this alarm when aluRMAlarmActionAuxRelay is set to 'true'. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.20 | ColumnaluRMAlarmDetectedTriggers | read-only | current | aluRMAlarmDetectedTriggers is a bitmask that identifies the currently detected triggers on this alarm. The bitmask is based on the trigger index assigned. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.21 | ColumnaluRMAlarmTHAnalogLevelOperation | read-create | current | aluRMAlarmTHAnalogLevelOperation indicates the operation to be performed to determine if aluRMAlarmTHAnalogLevel is crossed. The operation can not be 'not-moni… |
| 1.3.6.1.4.1.6527.6.1.2.2.11.1.3.1.22 | ColumnaluRMAlarmTHAnalogLevel | read-create | current | aluRMAlarmTHAnalogLevel indicates the analog voltage threshold of all analog triggers of this alarm. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.2 | NodealuRMNotifyObjs | |||
| 1.3.6.1.4.1.6527.6.1.2.2.11.2.1 | ScalaraluRMAlarmNotifyID | accessible-for-notify | current | Used by RM Alarm Notifications, the OID indicates the alarm identifier. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.2.2 | ScalaraluRMAlarmNotifyDescription | accessible-for-notify | current | A textual string containing user supplied information about the alarm. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.2.3 | ScalaraluRMNotifyID | accessible-for-notify | current | Used by RM Oper Notifications, the OID indicates the trigger or relay identifier. |
| 1.3.6.1.4.1.6527.6.1.2.2.11.2.4 | ScalaraluRMNotifyOperState | accessible-for-notify | current | Used by RM Oper Notifications, the OID indicates the trigger or relay oper state. |
| 1.3.6.1.4.1.6527.6.1.2.3.7 | NodealuRMNotifyPrefix | |||
| 1.3.6.1.4.1.6527.6.1.2.3.7.0 | NodealuRMNotification | |||
| 1.3.6.1.4.1.6527.6.1.2.3.7.0.1 | NotificationaluRMCriticalAlarm | current | Generated when remote-monitoring detects a change for a critical alarm. | |
| 1.3.6.1.4.1.6527.6.1.2.3.7.0.2 | NotificationaluRMMajorAlarm | current | Generated when remote-monitoring detects a change for a major alarm. | |
| 1.3.6.1.4.1.6527.6.1.2.3.7.0.3 | NotificationaluRMMinorAlarm | current | Generated when remote-monitoring detects a change for a minor alarm. | |
| 1.3.6.1.4.1.6527.6.1.2.3.7.0.4 | NotificationaluRMWarningAlarm | current | Generated when remote-monitoring detects a change for a warning alarm. | |
| 1.3.6.1.4.1.6527.6.1.2.3.7.0.5 | NotificationaluRMClearingAlarm | current | Generated when remote-monitoring detects the clearing of an alarm. | |
| 1.3.6.1.4.1.6527.6.1.2.3.7.0.6 | NotificationaluRMOperStateUpdate | current | Generated when triggers or relays change operational state. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| AluRMAdminStatus | INTEGER { unknown (0), disabled (1), enabled (2) } | current | The administrative status of monitoring. |
| AluRMAlias | DisplayString (SIZE(0..15)) | current | Unique alias name of a remote site alarm object. Note, use only NVT ASCII displayable characters here, no control characters, no UTF-8, etc. |
| AluRMExtAlarmID | Unsigned32 | current | An AluRMExtAlarmID is a unique 32 bit number that represents a physical alarm-connector equipped on an auxiliary alarm module. This connector can be used for monitoring and management of remote site and devices. Encoded… |
| AluRMOperStatus | INTEGER { unknown (0), ghost (1), not-monitored (2), ok (3), active (4) } | current | The operational status of monitoring. unknown - the current status is not known ghost - associated hardware is not present or offline not-monitored - monitoring is disabled ok - alarm state is ok active - alarm detected |