ARISTA-ENTITY-SENSOR-MIB

17 objects
This MIB module augments the entPhySensorTable of ENTITY-SENSOR-MIB to provide threshold information for various sensors in the system. For example, a given device may have several voltage sensors as well as temperature sensors each with appropriate threshold support to help NMS systems detect and alert appropriately. In addition, on systems where it is supported, if the sensor value crosses the supported threshold value the system can generate appropriate notification as well.
OIDNameAccessStatusDescription
1.3.6.1.4.1.30065.3.12IdentityaristaEntSensorMIBThis MIB module augments the entPhySensorTable of ENTITY-SENSOR-MIB to provide threshold information for various sensors in the system. For example, a given de…
1.3.6.1.4.1.30065.3.12.0NodearistaEntSensorMibNotifications
1.3.6.1.4.1.30065.3.12.0.1NotificationaristaEntSensorAlarmcurrentThis notification is generated under 2 conditions: a) When the value of the sensor value crosses a supported low or high threshold into warning or critical sta…
1.3.6.1.4.1.30065.3.12.1NodearistaEntSensorMibObjects
1.3.6.1.4.1.30065.3.12.1.1TablearistaEntSensorThresholdTablenot-accessiblecurrentThis table contains threshold information for the various sensors in the system.
1.3.6.1.4.1.30065.3.12.1.1.1RowaristaEntSensorThresholdEntrynot-accessiblecurrentA single row containing threshold information for a sensor. Threshold values are reported using the unit of EntitySensorValue. If a sensor does not support thr…
1.3.6.1.4.1.30065.3.12.1.1.1.1ColumnaristaEntSensorThresholdLowWarningread-onlycurrentThe low thresold value for the given sensor at which point the entity's alarm status is set to warning.
1.3.6.1.4.1.30065.3.12.1.1.1.2ColumnaristaEntSensorThresholdLowCriticalread-onlycurrentThe low critical value for the given sensor at which point the entity's alarm status is set to critical.
1.3.6.1.4.1.30065.3.12.1.1.1.3ColumnaristaEntSensorThresholdHighWarningread-onlycurrentThe high thresold value for the given sensor at which point the entity's alarm status is set to warning.
1.3.6.1.4.1.30065.3.12.1.1.1.4ColumnaristaEntSensorThresholdHighCriticalread-onlycurrentThe high critical value for the given sensor at which point the entity's alarm status is set to critical.
1.3.6.1.4.1.30065.3.12.1.1.1.5ColumnaristaEntSensorStatusDescrread-onlycurrentA textual description of the current status of the sensor. It serves as a human-readable representation of the operating status including any threshold alerts.
1.3.6.1.4.1.30065.3.12.2NodearistaEntSensorMibConformance
1.3.6.1.4.1.30065.3.12.2.1NodearistaEntSensorMibCompliances
1.3.6.1.4.1.30065.3.12.2.1.1CompliancearistaEntSensorMibCompliancecurrentThe compliance statement for Arista switches that implement the ARISTA-ENTITY-SENSOR-MIB.
1.3.6.1.4.1.30065.3.12.2.2NodearistaEntSensorMibGroups
1.3.6.1.4.1.30065.3.12.2.2.1GrouparistaEntSensorThresholdGroupcurrentThe collection of objects that provide threshold information for the sensors in the system.
1.3.6.1.4.1.30065.3.12.2.2.2GrouparistaEntSensorNotificationsGroupcurrentThe collection of notifications generated by the system if sensor(s) change value are not within the acceptable operating range.