MIB Viewer

ARUBAWIRED-LLDP-MIB

71 objects
This MIB module describes management objects that manage LLDP information related to Power Source Equipment (PSE). This is the MIB module related to HPE Aruba LLDP
OIDNameAccessStatusDescription
1.3.6.1.4.1.47196.4.1.1.3.9IdentityarubaWiredLldpMIBThis MIB module describes management objects that manage LLDP information related to Power Source Equipment (PSE). This is the MIB module related to HPE Aruba …
1.3.6.1.4.1.47196.4.1.1.3.9.1NodearubaWiredLldpXdot3Objects
1.3.6.1.4.1.47196.4.1.1.3.9.1.1NodearubaWiredLldpXdot3LocalData
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1TablearubaWiredLldpXdot3LocPowerTablenot-accessiblecurrentThis table contains one row per port of power ethernet information (as a part of the LLDP 802.3bt organizational extension) on the local system known to this a…
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1RowarubaWiredLldpXdot3LocPowerEntrynot-accessiblecurrentInformation about a particular port component.
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.1ColumnarubaWiredLldpXdot3LocPowerPortClassread-onlycurrentThe value that identifies the port Class of the given port associated with the local system.
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.2ColumnarubaWiredLldpXdot3LocPowerMDISupportedread-onlycurrentThe truth value used to indicate whether the MDI power is supported on the given port associated with the local system.
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.3ColumnarubaWiredLldpXdot3LocPowerMDIEnabledread-onlycurrentThe truth value used to indicate whether the MDI power is enabled on given port associated with the local system.
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.4ColumnarubaWiredLldpXdot3LocPowerPairControlableread-onlycurrentThe truth value used to indicate the ability to control which PSE Pinout Alternative is used for PD detection and power.
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.5ColumnarubaWiredLldpXdot3LocPowerPairsread-onlycurrentThe truth value that identifies the PSE Pinout Alternative in use for detecting and supplying power to the PD.
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.6ColumnarubaWiredLldpXdot3LocPowerClassread-onlycurrentThe truth value that indicates the requested Class of the PD.
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.7ColumnarubaWiredLldpXdot3LocPowerTyperead-onlycurrentThis field reflects the actual local power type.
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.8ColumnarubaWiredLldpXdot3LocPowerSourceread-onlycurrentThis field reflects the requested local device power source. When the power type is PSE, this field shall be set to primary(2) when the PSE is sourcing its pow…
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.9ColumnarubaWiredLldpXdot3LocPowerPriorityread-writecurrentThis field reflects the requested local device power priority. When the power type is PD, this field shall be set to the power priority configured for the devi…
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.10ColumnarubaWiredLldpXdot3LocPDRequestedPowerValueread-onlycurrentIt indicates the maximum input average power the PD is requesting in units of 0.1 W.
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.11ColumnarubaWiredLldpXdot3LocPDRequestedPowerValueAread-onlycurrentIt indicates the PD requested power value for the Mode A pairset in units of 0.1 W.
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.12ColumnarubaWiredLldpXdot3LocPDRequestedPowerValueBread-onlycurrentIt indicates the PD requested power value for the Mode B pairset in units of 0.1 W.
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.13ColumnarubaWiredLldpXdot3LocPSEAllocatedPowerValueread-onlycurrentIt indicates the maximum input average power the PSE expects the PD to draw in units of 0.1 W.
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.14ColumnarubaWiredLldpXdot3LocPSEAllocatedPowerValueAread-onlycurrentIt indicates the maximum input average power levels the PSE expects the dual-signature PD to draw, in units of 0.1 W, on Alternative A, when the PSE provides p…
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.15ColumnarubaWiredLldpXdot3LocPSEAllocatedPowerValueBread-onlycurrentIt indicates the maximum input average power levels the PSE expects the dual-signature PD to draw, in units of 0.1 W, on Alternative B, when the PSE provides p…
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.16ColumnarubaWiredLldpXdot3LocPSEPoweringStatusread-writecurrentThis field reflects the existing powering configuration of the PSE and thus indicates that the PSE is using the 'PSE allocated power value' field or is using t…
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.17ColumnarubaWiredLldpXdot3LocPowerPairsExtread-writecurrentThis field indicates the supported PSE Pinout Alternative. For a PD the contents of this attribute are undefined
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.18ColumnarubaWiredLldpXdot3LocPowerClassExtAread-writecurrentFor a dual-signature PD, it indicates the requested Class for Mode A during Physical Layer Classification. For a single-signature PD, a read-only value set to …
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.19ColumnarubaWiredLldpXdot3LocPowerClassExtBread-writecurrentFor a dual-signature PD, it indicates the requested Class for Mode B during Physical Layer Classification. For a single-signature PD, a read-only value set to …
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.20ColumnarubaWiredLldpXdot3LocPowerClassExtread-writecurrentFor a single-signature PD, it indicates the requested Class during Physical Layer Classification. For a dual-signature PD, the value is set to 'dualsig'. For a…
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.21ColumnarubaWiredLldpXdot3LocPowerTypeExtread-onlycurrentThis field indicates if the local system is a Type 3 or Type 4 PSE or PD, and in the case of a Type 3 or Type 4 PD, if it is a single-signature PD or a dual-si…
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.22ColumnarubaWiredLldpXdot3LocPDLoadread-onlycurrentThe truth value used to indicate whether the load of a dual- signature PD is electrically isolated. For a single-signature PD, or a PSE, the value of this attr…
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.23ColumnarubaWiredLldpXdot3LocPSEMaxAvailPowerread-onlycurrentIt indicates the local PSE maximum available power value in units of 0.1 W.
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.24ColumnarubaWiredLldpXdot3LocPSEAutoclassSupportread-onlycurrentIt indicates whether the local PSE system supports Autoclass
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.25ColumnarubaWiredLldpXdot3LocAutoclassCompletedread-onlycurrentIt indicates whether the local PSE system has completed the Autoclass measurement
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.26ColumnarubaWiredLldpLocPseTlvSentTyperead-onlycurrentThis field specifies the set of TLVs that are actually sent by the PSE
1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.27ColumnarubaWiredLldpLocPdTlvSentTyperead-onlycurrentThis field specifies the set of TLVs that are actually sent by the PD
1.3.6.1.4.1.47196.4.1.1.3.9.1.2NodearubaWiredLldpXdot3RemoteData
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1TablearubaWiredLldpXdot3RemPowerTablenot-accessiblecurrentThis table contains one row per port of power ethernet information (as a part of the LLDP 802.3bt organizational extension) on the remote system known to this …
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1RowarubaWiredLldpXdot3RemPowerEntrynot-accessiblecurrentInformation about a particular port component.
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.1ColumnarubaWiredLldpXdot3RemPowerPortClassread-onlycurrentThe value that identifies the port Class of the given port associated with the remote system.
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.2ColumnarubaWiredLldpXdot3RemPowerMDISupportedread-onlycurrentThe truth value used to indicate whether the MDI power is supported on the given port associated with the remote system.
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.3ColumnarubaWiredLldpXdot3RemPowerMDIEnabledread-onlycurrentThe truth value used to indicate whether the MDI power is enabled on given port associated with the remote system.
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.4ColumnarubaWiredLldpXdot3RemPowerPairControlableread-onlycurrentThe truth value used to indicate the ability to control which PSE Pinout Alternative is used for PD detection and power.
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.5ColumnarubaWiredLldpXdot3RemPowerPairsread-onlycurrentThe truth value that identifies the PSE Pinout Alternative in use for detecting and supplying power to the PD.
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.6ColumnarubaWiredLldpXdot3RemPowerClassread-onlycurrentThe truth value that indicates the requested Class of the PD.
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.7ColumnarubaWiredLldpXdot3RemPowerTyperead-onlycurrentThis field reflects the actual remote power type.
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.8ColumnarubaWiredLldpXdot3RemPowerSourceread-onlycurrentThis field reflects the remote device (PD) requested power source. This field is encoded as pseAndLocal(4) when a PD being powered both locally and by a PSE, t…
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.9ColumnarubaWiredLldpXdot3RemPowerPriorityread-writecurrentThis field reflects the requested remote device power priority. When the power type is PD, this field shall be set to the power priority configured for the dev…
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.10ColumnarubaWiredLldpXdot3RemPDRequestedPowerValueread-onlycurrentIt indicates the maximum input average power the PD is requesting in units of 0.1 W.
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.11ColumnarubaWiredLldpXdot3RemPDRequestedPowerValueAread-onlycurrentIt indicates the PD requested power value for the Mode A pairset in units of 0.1 W.
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.12ColumnarubaWiredLldpXdot3RemPDRequestedPowerValueBread-onlycurrentIt indicates the PD requested power value for the Mode B pairset in units of 0.1 W.
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.13ColumnarubaWiredLldpXdot3RemPSEAllocatedPowerValueread-onlycurrentIt indicates the PSE allocated power value received from the remote system. For a PSE, it is the PSE allocated power value that was echoed back by the remote P…
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.14ColumnarubaWiredLldpXdot3RemPSEAllocatedPowerValueAread-onlycurrentIt indicates the PSE allocated power value for the Alternative A pairset received from the remote system. For a PSE, it is the PSE allocated power value for th…
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.15ColumnarubaWiredLldpXdot3RemPSEAllocatedPowerValueBread-onlycurrentIt indicates the PSE allocated power value for the Alternative B pairset received from the remote system. For a PSE, it is the PSE allocated power value for th…
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.16ColumnarubaWiredLldpXdot3RemPDPoweredStatusread-writecurrentThis field indicates the existing powered configuration of the PD and thus indicate that the PD is using the 'PD requested power value' field or is using the '…
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.17ColumnarubaWiredLldpXdot3RemPowerClassExtAread-writecurrentFor a dual-signature PD, a read-only value that indicates the currently assigned Class for Mode A by the remote 4-pair PSE. For a single-signature PD, or a dua…
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.18ColumnarubaWiredLldpXdot3RemPowerClassExtBread-writecurrentFor a dual-signature PD, a read-only value that indicates the currently assigned Class for Mode A by the remote 4-pair PSE. For a single-signature PD, or a dua…
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.19ColumnarubaWiredLldpXdot3RemPowerClassExtread-writecurrentFor a single-signature PD or a dual-signature PD connected to a 2-pair only PSE, a read-only value that indicates the currently assigned Class by the remote PS…
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.20ColumnarubaWiredLldpXdot3RemPowerTypeExtread-onlycurrentThis field indicates if the remote system is a Type 3 or Type 4 PSE or PD, and in the case of a Type 3 or Type 4 PD, if it is a single-signature PD or dual-sig…
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.21ColumnarubaWiredLldpXdot3RemPDLoadread-onlycurrentThe truth value used to indicate whether the load of the remote dual-signature PD is electrically isolated. For a PD this attribute is set to FALSE
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.22ColumnarubaWiredLldpXdot3RemPD4PIDread-onlycurrentThe truth value used to indicate whether the remote PD system supports powering of both PD Modes
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.23ColumnarubaWiredLldpXdot3RemPSEMaxAvailPowerread-onlycurrentIt indicates the remote PSE maximum available power value in units of 0.1 W.
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.24ColumnarubaWiredLldpXdot3RemAutoclassRequestread-onlycurrentIt indicates whether the remote PD system is requesting an Autoclass measurement
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.25ColumnarubaWiredLldpXdot3RemPowerDownRequestread-onlycurrentIt indicates that the remote PD system is requesting a power down when the value is 0x1D
1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.26ColumnarubaWiredLldpXdot3RemPowerDownTimeread-onlycurrentIt indicates the number of seconds the remote PD requests to stay powered off. A value of zero indicates an indefinite amount of time.
1.3.6.1.4.1.47196.4.1.1.3.9.2NodearubaWiredLldpConformance
1.3.6.1.4.1.47196.4.1.1.3.9.2.1NodearubaWiredLldpCompliances
1.3.6.1.4.1.47196.4.1.1.3.9.2.1.1CompliancearubaWiredLldpXdot3CompliancecurrentThe compliance statement for LLDP implementation.
1.3.6.1.4.1.47196.4.1.1.3.9.2.1.2CompliancearubaWiredLldpScalarCompliancecurrentThe compliance statement for LLDP scalars.
1.3.6.1.4.1.47196.4.1.1.3.9.2.2NodearubaWiredLldpGroups
1.3.6.1.4.1.47196.4.1.1.3.9.2.2.1GrouparubaWiredLldpXdot3LocSysGroupcurrentThe collection of objects which are used to represent LLDP 802.3 organizational extension for POEP Local Device Information. This group is mandatory for agents…
1.3.6.1.4.1.47196.4.1.1.3.9.2.2.2GrouparubaWiredLldpXdot3RemSysGroupcurrentThe collection of objects which are used to represent LLDP 802.3 organizational extension for POEP Remote Device Information. This group is mandatory for agent…
1.3.6.1.4.1.47196.4.1.1.3.9.2.2.3GrouparubaWiredLldpScalarGroupcurrentThese objects are used for managing/monitoring LLDP global parameters.
1.3.6.1.4.1.47196.4.1.1.3.9.3NodearubaWiredLldpScalarConfig
1.3.6.1.4.1.47196.4.1.1.3.9.3.1ScalararubaWiredLldpMgmtAddrVlanIdread-writecurrentDefines the LLDP management VLAN whose IPv4/IPv6 address will be advertised. Value '0' indicates that LLDP management VLAN is not configured.