MIB Viewer

ARUBAWIRED-POE-MIB

54 objects
This MIB module describes management objects that manage Power Source Equipment (PSE). This is the MIB module related to HPE Aruba PoE
Imported Objects
ARUBAWIRED-NETWORKING-OIDwndFeatures
POWER-ETHERNET-MIBpethMainPseEntry pethPsePortEntry
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMICounter32 Integer32 MODULE-IDENTITY OBJECT-TYPE
OIDNameAccessStatusDescription
1.3.6.1.4.1.47196.4.1.1.3.8IdentityarubaWiredPoeMIBThis MIB module describes management objects that manage Power Source Equipment (PSE). This is the MIB module related to HPE Aruba PoE
1.3.6.1.4.1.47196.4.1.1.3.8.1NodearubaWiredPoePethPsePort
1.3.6.1.4.1.47196.4.1.1.3.8.1.1TablearubaWiredPoePethPsePortTablenot-accessiblecurrentA table of objects that display and control the power characteristics of power Ethernet ports on a Power Source Entity (PSE) device. This group will be impleme…
1.3.6.1.4.1.47196.4.1.1.3.8.1.1.1RowarubaWiredPoePethPsePortEntrynot-accessiblecurrentThe fields in these entries will be used to supplement fields in 'pethPsePortEntry in ieee802af.mib.
1.3.6.1.4.1.47196.4.1.1.3.8.1.1.1.1ColumnarubaWiredPoePethPsePortPowerAllocateByread-writecurrentAllows control over the power allocation strategy used for this port. Two power allocation strategies are class(2) and usage(1). When allocating by usage(1) po…
1.3.6.1.4.1.47196.4.1.1.3.8.1.1.1.2ColumnarubaWiredPoePethPsePortPreStdDetectread-onlycurrentThis field specifies the pre standard detect configuration for this port. A value of on - indicates that pre-802.3af-standard devices to power on. A value of o…
1.3.6.1.4.1.47196.4.1.1.3.8.1.1.1.3ColumnarubaWiredPoePethPsePortRpdread-onlycurrentRapid Power Down is executed by the hardware in the event of a power-supply failure. It quickly cuts power to a PD to prevent an over-current scenario in the P…
1.3.6.1.4.1.47196.4.1.1.3.8.1.1.1.4ColumnarubaWiredPoePethPsePortCurrentread-onlycurrentThis field specifies the current supplied at this port. This value is specified in milliamperes(mA).
1.3.6.1.4.1.47196.4.1.1.3.8.1.1.1.5ColumnarubaWiredPoePethPsePortVoltageread-onlycurrentThis field specifies the Voltage supplied at this port. This value is specified in 10's of Volts (dV).
1.3.6.1.4.1.47196.4.1.1.3.8.1.1.1.6ColumnarubaWiredPoePethPsePortReservedPowerread-onlycurrentThis field specifies quantum of power which has been reserved for the PD at this port. This value is specified in milliwatts (mW).
1.3.6.1.4.1.47196.4.1.1.3.8.1.1.1.7ColumnarubaWiredPoePethPsePortPowerDrawnread-onlycurrentThis field specifies quantum of power which has indicating the actual power drawn by powered device(PD). This value is specified in milliwatts (mW).
1.3.6.1.4.1.47196.4.1.1.3.8.1.1.1.8ColumnarubaWiredPoePethPsePortAveragePowerread-onlycurrentThis field specifies the average power in milliwatts drawn by the powered device (PD) on this port.
1.3.6.1.4.1.47196.4.1.1.3.8.1.1.1.9ColumnarubaWiredPoePethPsePortPeakPowerread-onlycurrentThis field specifies the peak power supplied in milliwatts to the powered device (PD) connected to this port.
1.3.6.1.4.1.47196.4.1.1.3.8.1.1.1.10ColumnarubaWiredPoePethPsePortOperStatusread-onlycurrentThis field specifies the operational status of the port.
1.3.6.1.4.1.47196.4.1.1.3.8.1.1.1.11ColumnarubaWiredPoePethPsePortPdSignatureread-onlycurrentThis Signature value represents the PD signature. This variable is valid only while a PD is detected. In 802.3af and 802.3at standards the power controller on …
1.3.6.1.4.1.47196.4.1.1.3.8.1.1.1.12ColumnarubaWiredPoePethPsePortPowerClassificationread-onlycurrentA read-only value that indicates the PD Class of a detected PD. Classification is a way to tag different terminals on the Power over LAN network according to t…
1.3.6.1.4.1.47196.4.1.1.3.8.1.1.1.13ColumnarubaWiredPoePethPsePortPseAssignedClassread-onlycurrentThis field indicates the actual class assigned by PSE to the PD. Class demotion allows the PSE to allocate less than the PD requested power based on the PD req…
1.3.6.1.4.1.47196.4.1.1.3.8.1.1.1.14ColumnarubaWiredPoePethPsePortPoECycleread-writecurrentThis object is used for PoE port reset with timeout of 1-60s. PoE interface is disabled and then enabled with timeout as input.
1.3.6.1.4.1.47196.4.1.1.3.8.1.2TablearubaWiredPoePethPseFourPairPortTablenot-accessiblecurrentA table of objects that display and control the power characteristics of power Ethernet ports on a Power Source Entity (PSE) device. This group will be impleme…
1.3.6.1.4.1.47196.4.1.1.3.8.1.2.1RowarubaWiredPoePethPseFourPairPortEntrynot-accessiblecurrentThe fields in these entries will be used to supplement fields in 'pethPsePortEntry in ieee802af.mib.
1.3.6.1.4.1.47196.4.1.1.3.8.1.2.1.1ColumnarubaWiredPoePethPsePortDetectionStatusPairAread-onlycurrentDescribes the operational status of the port PD detection. A value of deliveringPowerAltA - indicates that the PSE State diagram is in the state POWER_ON_PRI i…
1.3.6.1.4.1.47196.4.1.1.3.8.1.2.1.2ColumnarubaWiredPoePethPsePortDetectionStatusPairBread-onlycurrentDescribes the operational status of the port PD detection. A value of deliveringPowerAltB - indicates that the PSE State diagram is in the state POWER_ON_SEC i…
1.3.6.1.4.1.47196.4.1.1.3.8.1.2.1.3ColumnarubaWiredPoePethPsePortPowerClassificationPairAread-onlycurrentA read-only value that indicates the PD Class of a detected dual-signature PD on paira. Classification is a way to tag different terminals on the Power over LA…
1.3.6.1.4.1.47196.4.1.1.3.8.1.2.1.4ColumnarubaWiredPoePethPsePortPowerClassificationPairBread-onlycurrentA read-only value that indicates the PD Class of a detected dual-signature PD on paira. Classification is a way to tag different terminals on the Power over LA…
1.3.6.1.4.1.47196.4.1.1.3.8.1.2.1.5ColumnarubaWiredPoePethPsePortPseAssignedClassAread-onlycurrentThis field indicates the actual class assigned by PSE to the PD. Class demotion allows the PSE to allocate less than the PD requested power based on the PD req…
1.3.6.1.4.1.47196.4.1.1.3.8.1.2.1.6ColumnarubaWiredPoePethPsePortPseAssignedClassBread-onlycurrentThis field indicates the actual class assigned by PSE to the PD. Class demotion allows the PSE to allocate less than the PD requested power based on the PD req…
1.3.6.1.4.1.47196.4.1.1.3.8.1.2.1.7ColumnarubaWiredPoePethPsePortInvalidSignatureCounterPairAread-onlycurrentThis counter is incremented when the PSE state diagram enters the state SIGNATURE_INVALID, if alt_pri='a'.
1.3.6.1.4.1.47196.4.1.1.3.8.1.2.1.8ColumnarubaWiredPoePethPsePortInvalidSignatureCounterPairBread-onlycurrentThis counter is incremented when the PSE state diagram enters the state SIGNATURE_INVALID, if alt_pri='b'
1.3.6.1.4.1.47196.4.1.1.3.8.1.2.1.9ColumnarubaWiredPoePethPsePortPowerDeniedCounterPairAread-onlycurrentThis counter is incremented when the PSE state diagram enters the state POWER_DENIED, if alt_pri='a'.
1.3.6.1.4.1.47196.4.1.1.3.8.1.2.1.10ColumnarubaWiredPoePethPsePortPowerDeniedCounterPairBread-onlycurrentThis counter is incremented when the PSE state diagram enters the state POWER_DENIED, if alt_pri='b'.
1.3.6.1.4.1.47196.4.1.1.3.8.1.2.1.11ColumnarubaWiredPoePethPsePortOverLoadCounterPairAread-onlycurrentThis counter is incremented when the PSE state diagram enters the state ERROR_DELAY_OVER, if alt_pri='a'.
1.3.6.1.4.1.47196.4.1.1.3.8.1.2.1.12ColumnarubaWiredPoePethPsePortOverLoadCounterPairBread-onlycurrentThis counter is incremented when the PSE state diagram enters the state ERROR_DELAY_OVER, if alt_pri='b'.
1.3.6.1.4.1.47196.4.1.1.3.8.1.2.1.13ColumnarubaWiredPoePethPsePortMPSAbsentCounterPairAread-onlycurrentThis counter is incremented when the PSE state diagram transitions directly from the state POWER_ON to the state IDLE due to tmpdo_timer_done being asserted, i…
1.3.6.1.4.1.47196.4.1.1.3.8.1.2.1.14ColumnarubaWiredPoePethPsePortMPSAbsentCounterPairBread-onlycurrentThis counter is incremented when the PSE state diagram transitions directly from the state POWER_ON to the state IDLE due to tmpdo_timer_done being asserted, i…
1.3.6.1.4.1.47196.4.1.1.3.8.2NodearubaWiredPoeConformance
1.3.6.1.4.1.47196.4.1.1.3.8.2.1NodearubaWiredPoeCompliances
1.3.6.1.4.1.47196.4.1.1.3.8.2.1.1CompliancearubaWiredPoeCompliancecurrentA compliance statement for HP Routing switches with PoE capability.
1.3.6.1.4.1.47196.4.1.1.3.8.2.2NodearubaWiredPoeGroups
1.3.6.1.4.1.47196.4.1.1.3.8.2.2.1GrouparubaWiredPoePethPsePortTableGroupcurrentA collection of objects display configuration, status, PD information and mesurements of PoE PSE Port table.
1.3.6.1.4.1.47196.4.1.1.3.8.2.2.2GrouparubaWiredPoePethPseFourPairPortTableGroupcurrentA collection of objects display four pair paramentets of each pair PD information, status, and counters of PoE PSE Port table.
1.3.6.1.4.1.47196.4.1.1.3.8.2.2.3GrouparubaWiredPoePethMainPseTableGroupcurrentA Collection of Object(s) that provide information about each power source equipment instance.
1.3.6.1.4.1.47196.4.1.1.3.8.2.2.4GrouparubaWiredPoePethPseModuleTableGroupcurrentA Collection of Object(s) that provide AlwaysOnPoe information about each module on switch.
1.3.6.1.4.1.47196.4.1.1.3.8.3NodearubaWiredPoePethMainPse
1.3.6.1.4.1.47196.4.1.1.3.8.3.1TablearubaWiredPoePethMainPseTablenot-accessiblecurrentA table of objects that display and control attributes of the main power source in a PSE device. Ethernet switches are one example of boxes that would support …
1.3.6.1.4.1.47196.4.1.1.3.8.3.1.1RowarubaWiredPoePethMainPseEntrynot-accessiblecurrentThe fields in these entries will be used to supplement fields in 'pethMainPseEntry in ieee802af.mib.
1.3.6.1.4.1.47196.4.1.1.3.8.3.1.1.1ColumnarubaWiredPoePethMainPseReservedPowerread-onlycurrentThis field specifies the power in Watts, in the switch available for PoE power delivery. This power is available only for subsystems of type chassis, as power …
1.3.6.1.4.1.47196.4.1.1.3.8.3.1.1.2ColumnarubaWiredPoePethMainPseFailoverPowerread-onlycurrentThis field specifies the power in Watts, in the switch available for PoE power delivery when a single power supply failure happens. This power is available onl…
1.3.6.1.4.1.47196.4.1.1.3.8.3.1.1.3ColumnarubaWiredPoePethMainPseRedundantPowerread-onlycurrentThis field specifies power in Watts reserved by power supply based on power redundancy configurations. This power is available only for subsystems of type chas…
1.3.6.1.4.1.47196.4.1.1.3.8.4NodearubaWiredPoePethPseModule
1.3.6.1.4.1.47196.4.1.1.3.8.4.1TablearubaWiredPoePethPseModuleTablenot-accessiblecurrentA table of objects contains the AlwaysOnPoe status information on module.
1.3.6.1.4.1.47196.4.1.1.3.8.4.1.1RowarubaWiredPoePethPseModuleEntrynot-accessiblecurrentThe fields in these entries will be used to display alwaysonpoe status information on specific module.
1.3.6.1.4.1.47196.4.1.1.3.8.4.1.1.1ColumnarubaWiredPoePethPseModuleGroupIndexnot-accessiblecurrentThis variable uniquely identifies the group containing the module to which a power Ethernet PSE is connected. Group means box in the stack and the value 1 MUST…
1.3.6.1.4.1.47196.4.1.1.3.8.4.1.1.2ColumnarubaWiredPoePethPseModuleSlotIndexnot-accessiblecurrentThis variable uniquely identifies the module in a switch and value 1 must be used for non-modular devices.
1.3.6.1.4.1.47196.4.1.1.3.8.4.1.1.3ColumnarubaWiredPoePethPseModuleAlwaysOnPoeread-onlycurrentAlwayson PoE is a feature that provides the ability for a switch to continue to provide power across a soft reboot. Value on(2) indicates Always-on PoE feature…