AT-ENVMONv2-MIB
107 objects
The AT Environment Monitoring v2 MIB for managing and reporting data relating to voltage rails, fan speeds, temperature sensors and power supply units.
Imported Objects
| AT-SMI-MIB | DisplayStringUnsized |
| AT-SYSINFO-MIB | sysinfo |
| SNMPv2-SMI | MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.207.8.4.4.3.12 | IdentityatEnvMonv2 | The AT Environment Monitoring v2 MIB for managing and reporting data relating to voltage rails, fan speeds, temperature sensors and power supply units. | ||
| 1.3.6.1.4.1.207.8.4.4.3.12.0 | NodeatEnvMonv2Notifications | |||
| 1.3.6.1.4.1.207.8.4.4.3.12.0.1 | NotificationatEnvMonv2FanAlarmSetNotify | current | A notification generated when the monitored speed of a fan drops below its lower threshold. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.0.2 | NotificationatEnvMonv2FanAlarmClearedNotify | current | A notification generated when the monitored speed of a fan returns to an acceptable value, the fan having previously been in an alarm condition. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.0.3 | NotificationatEnvMonv2VoltAlarmSetNotify | current | A notification generated when the voltage of a monitored voltage rail goes out of tolerance, either by dropping below its lower threshold, or exceeding its upp… | |
| 1.3.6.1.4.1.207.8.4.4.3.12.0.4 | NotificationatEnvMonv2VoltAlarmClearedNotify | current | A notification generated when the voltage of a monitored voltage rail returns to an acceptable value, having previously been in an alarm condition. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.0.5 | NotificationatEnvMonv2TempAlarmSetNotify | current | A notification generated when a monitored temperature exceeds its upper threshold. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.0.6 | NotificationatEnvMonv2TempAlarmClearedNotify | current | A notification generated when a monitored temperature returns to an acceptable value, having previously been in an alarm condition. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.0.7 | NotificationatEnvMonv2PsbAlarmSetNotify | current | A notification generated when a monitored parameter of a power supply bay device goes out of tolerance. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.0.8 | NotificationatEnvMonv2PsbAlarmClearedNotify | current | A notification generated when a monitored parameter of a power supply bay device returns to an acceptable value, having previously been in an alarm condition. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.0.9 | NotificationatEnvMonv2ContactInputOpenNotify | current | A notification generated when a monitored contact input opens. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.0.10 | NotificationatEnvMonv2ContactInputCloseNotify | current | A notification generated when a monitored contact input closes. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.0.11 | NotificationatEnvMonv2ExternalPSUAlarmSetNotify | current | A notification generated when supply potential of a monitored external power supply is not present. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.0.12 | NotificationatEnvMonv2ExternalPSUAlarmClearedNotify | current | A notification generated when supply potential of a monitored external power supply returns to an acceptable value, having previously been in an alarm conditio… | |
| 1.3.6.1.4.1.207.8.4.4.3.12.0.13 | NotificationatEnvMonv2TempCriticalSetNotify | current | A notification generated when a monitored temperature exceeds its upper threshold. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.0.14 | NotificationatEnvMonv2TempCriticalClearedNotify | current | A notification generated when a monitored temperature returns to an acceptable value, having previously been in an alarm condition. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.0.15 | NotificationatEnvMonv2TempCriticalLevel1SetNotify | current | A notification generated when a monitored temperature exceeds the level 1 threshold. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.0.16 | NotificationatEnvMonv2TempCriticalLevel1ClearedNotify | current | A notification generated when a monitored temperature returns to an acceptable value, having previously been in critical temperature level 1 condition. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.0.17 | NotificationatEnvMonv2TempCriticalLevel2SetNotify | current | A notification generated when a monitored temperature exceeds the level 2 threshold. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.0.18 | NotificationatEnvMonv2TempCriticalLevel2ClearedNotify | current | A notification generated when a monitored temperature returns to an acceptable value, having previously been in critical temperature level 2 condition. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.0.19 | NotificationatEnvMonv2PsbPresenceChangeNotify | current | A notification generated when an insertion or removal event is detected on a power supply bay device. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.1 | TableatEnvMonv2FanTable | not-accessible | current | A table of information about fans installed in the device that have their fan speeds monitored by environment monitoring hardware. |
| 1.3.6.1.4.1.207.8.4.4.3.12.1.1 | RowatEnvMonv2FanEntry | not-accessible | current | The description, current speed, lower threshold speed and current status of a fan. |
| 1.3.6.1.4.1.207.8.4.4.3.12.1.1.1 | ColumnatEnvMonv2FanStackMemberId | read-only | current | The index of the stack member hosting this fan. For a chassis switch, it corresponds to the card ID of the controller that is monitoring the chassis hardware, … |
| 1.3.6.1.4.1.207.8.4.4.3.12.1.1.2 | ColumnatEnvMonv2FanBoardIndex | read-only | current | The index of the board hosting this fan in the board table. |
| 1.3.6.1.4.1.207.8.4.4.3.12.1.1.3 | ColumnatEnvMonv2FanIndex | read-only | current | The numeric identifier of this fan on its host board. |
| 1.3.6.1.4.1.207.8.4.4.3.12.1.1.4 | ColumnatEnvMonv2FanDescription | read-only | current | The description of this fan. |
| 1.3.6.1.4.1.207.8.4.4.3.12.1.1.5 | ColumnatEnvMonv2FanCurrentSpeed | read-only | current | The current speed of this fan in revolutions per minute. |
| 1.3.6.1.4.1.207.8.4.4.3.12.1.1.6 | ColumnatEnvMonv2FanLowerThreshold | read-only | current | The minimum acceptable speed of the fan in revolutions per minute. |
| 1.3.6.1.4.1.207.8.4.4.3.12.1.1.7 | ColumnatEnvMonv2FanStatus | read-only | current | An indication of whether this fan is currently in an alarm condition. A value of 'failed(1)' indicates that its current speed is too low, 'good(2)' indicates t… |
| 1.3.6.1.4.1.207.8.4.4.3.12.2 | TableatEnvMonv2VoltageTable | not-accessible | current | A table of information about voltage rails in the device that are monitored by environment monitoring hardware. |
| 1.3.6.1.4.1.207.8.4.4.3.12.2.1 | RowatEnvMonv2VoltageEntry | not-accessible | current | The description, current value, upper & lower threshold settings and current status of a voltage rail. |
| 1.3.6.1.4.1.207.8.4.4.3.12.2.1.1 | ColumnatEnvMonv2VoltageStackMemberId | read-only | current | The index of the stack member hosting this voltage sensor. For a chassis switch, it corresponds to the card ID of the controller that is monitoring the chassis… |
| 1.3.6.1.4.1.207.8.4.4.3.12.2.1.2 | ColumnatEnvMonv2VoltageBoardIndex | read-only | current | The index of the board hosting this voltage sensor in the board table. |
| 1.3.6.1.4.1.207.8.4.4.3.12.2.1.3 | ColumnatEnvMonv2VoltageIndex | read-only | current | The numeric identifier of this voltage rail on its host board. |
| 1.3.6.1.4.1.207.8.4.4.3.12.2.1.4 | ColumnatEnvMonv2VoltageDescription | read-only | current | The description of this voltage rail. |
| 1.3.6.1.4.1.207.8.4.4.3.12.2.1.5 | ColumnatEnvMonv2VoltageCurrent | read-only | current | The current reading of this voltage rail in millivolts. |
| 1.3.6.1.4.1.207.8.4.4.3.12.2.1.6 | ColumnatEnvMonv2VoltageUpperThreshold | read-only | current | The maximum acceptable reading of this voltage rail in millivolts. |
| 1.3.6.1.4.1.207.8.4.4.3.12.2.1.7 | ColumnatEnvMonv2VoltageLowerThreshold | read-only | current | The minimum acceptable reading of this voltage rail in millivolts. |
| 1.3.6.1.4.1.207.8.4.4.3.12.2.1.8 | ColumnatEnvMonv2VoltageStatus | read-only | current | An indication of whether this voltage rail is currently in an alarm condition. A value of 'outOfRange' indicates that its current reading is outside its thresh… |
| 1.3.6.1.4.1.207.8.4.4.3.12.3 | TableatEnvMonv2TemperatureTable | not-accessible | current | A table of information about temperature sensors in the device that are monitored by environment monitoring hardware. |
| 1.3.6.1.4.1.207.8.4.4.3.12.3.1 | RowatEnvMonv2TemperatureEntry | not-accessible | current | The description, current value, upper threshold setting and current status of a temperature sensor. |
| 1.3.6.1.4.1.207.8.4.4.3.12.3.1.1 | ColumnatEnvMonv2TemperatureStackMemberId | read-only | current | The index of the stack member hosting this temperature sensor. For a chassis switch, it corresponds to the card ID of the controller that is monitoring the cha… |
| 1.3.6.1.4.1.207.8.4.4.3.12.3.1.2 | ColumnatEnvMonv2TemperatureBoardIndex | read-only | current | The index of the board hosting this temperature sensor in the board table. |
| 1.3.6.1.4.1.207.8.4.4.3.12.3.1.3 | ColumnatEnvMonv2TemperatureIndex | read-only | current | The numeric identifier of this temperature sensor on its host board. |
| 1.3.6.1.4.1.207.8.4.4.3.12.3.1.4 | ColumnatEnvMonv2TemperatureDescription | read-only | current | The description of this temperature sensor. |
| 1.3.6.1.4.1.207.8.4.4.3.12.3.1.5 | ColumnatEnvMonv2TemperatureCurrent | read-only | current | The current reading of this temperature sensor in tenths of a degree Celsius. |
| 1.3.6.1.4.1.207.8.4.4.3.12.3.1.6 | ColumnatEnvMonv2TemperatureUpperThreshold | read-only | current | The maximum acceptable reading of this temperature sensor in tenths of a degree Celsius. |
| 1.3.6.1.4.1.207.8.4.4.3.12.3.1.7 | ColumnatEnvMonv2TemperatureStatus | read-only | current | An indication of whether this temperature sensor is currently in an alarm condition. A value of 'outOfRange' indicates that its current reading is outside its … |
| 1.3.6.1.4.1.207.8.4.4.3.12.4 | NodeatEnvMonv2PsbObjects | |||
| 1.3.6.1.4.1.207.8.4.4.3.12.4.1 | TableatEnvMonv2PsbTable | not-accessible | current | A table of information about power supply bays in the system and any devices that are installed. |
| 1.3.6.1.4.1.207.8.4.4.3.12.4.1.1 | RowatEnvMonv2PsbEntry | not-accessible | current | The description and current status of a power supply bay device. |
| 1.3.6.1.4.1.207.8.4.4.3.12.4.1.1.1 | ColumnatEnvMonv2PsbHostStackMemberId | read-only | current | The index of the stack member hosting this power supply bay. For a chassis switch, it corresponds to the card ID of the controller that is monitoring the chass… |
| 1.3.6.1.4.1.207.8.4.4.3.12.4.1.1.2 | ColumnatEnvMonv2PsbHostBoardIndex | read-only | current | The index of the board hosting this power supply bay in the board table. |
| 1.3.6.1.4.1.207.8.4.4.3.12.4.1.1.3 | ColumnatEnvMonv2PsbHostSlotIndex | read-only | current | The index of this power supply bay on its host board. This index is fixed for each slot, on each type of board. |
| 1.3.6.1.4.1.207.8.4.4.3.12.4.1.1.4 | ColumnatEnvMonv2PsbHeldBoardIndex | read-only | current | The index of a board installed in this power supply bay. This value corresponds to atEnvMonv2PsbSensorBoardIndex for each sensor on this board. A value of 0 in… |
| 1.3.6.1.4.1.207.8.4.4.3.12.4.1.1.5 | ColumnatEnvMonv2PsbHeldBoardId | read-only | current | The type of board installed in this power supply bay. The values of this object are taken from the pprXxx object IDs under the boards sub-tree in the parent MI… |
| 1.3.6.1.4.1.207.8.4.4.3.12.4.1.1.6 | ColumnatEnvMonv2PsbDescription | read-only | current | The description of this power supply bay. |
| 1.3.6.1.4.1.207.8.4.4.3.12.4.2 | TableatEnvMonv2PsbSensorTable | not-accessible | current | A table of information about environment monitoring sensors on devices installed in power supply bays. |
| 1.3.6.1.4.1.207.8.4.4.3.12.4.2.1 | RowatEnvMonv2PsbSensorEntry | not-accessible | current | The description and current status of a device installed in a power supply bay. |
| 1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.1 | ColumnatEnvMonv2PsbSensorStackMemberId | read-only | current | The index of the stack member hosting this sensor. For a chassis switch, it corresponds to the card ID of the controller that is monitoring the chassis hardwar… |
| 1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.2 | ColumnatEnvMonv2PsbSensorBoardIndex | read-only | current | The index of the board hosting this sensor in the board table. |
| 1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.3 | ColumnatEnvMonv2PsbSensorIndex | read-only | current | The index of this power supply bay environmental sensor on its host board. |
| 1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.4 | ColumnatEnvMonv2PsbSensorType | read-only | current | The type of environmental variable this sensor detects. |
| 1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.5 | ColumnatEnvMonv2PsbSensorDescription | read-only | current | The description of this power supply bay environmental sensor. |
| 1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.6 | ColumnatEnvMonv2PsbSensorStatus | read-only | current | An indication of whether this environmental sensor is currently in an alarm condition. A value of 'failed(1)' indicates that the device is in a failure conditi… |
| 1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.7 | ColumnatEnvMonv2PsbSensorReading | read-only | current | An indication of whether this environmental sensor is currently reading a value for the monitored device. A value of 'no' indicates that there is no current re… |
| 1.3.6.1.4.1.207.8.4.4.3.12.5 | NodeatEnvMonv2Traps | |||
| 1.3.6.1.4.1.207.8.4.4.3.12.5.1 | NotificationatEnvMonv2FanAlarmSetEvent | deprecated | A trap generated when the monitored speed of a fan drops below its lower threshold. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.5.2 | NotificationatEnvMonv2FanAlarmClearedEvent | deprecated | A trap generated when the monitored speed of a fan returns to an acceptable value, the fan having previously been in an alarm condition. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.5.3 | NotificationatEnvMonv2VoltAlarmSetEvent | deprecated | A trap generated when the voltage of a monitored voltage rail goes out of tolerance, either by dropping below its lower threshold, or exceeding its upper thres… | |
| 1.3.6.1.4.1.207.8.4.4.3.12.5.4 | NotificationatEnvMonv2VoltAlarmClearedEvent | deprecated | A trap generated when the voltage of a monitored voltage rail returns to an acceptable value, having previously been in an alarm condition. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.5.5 | NotificationatEnvMonv2TempAlarmSetEvent | deprecated | A trap generated when a monitored temperature exceeds its upper threshold. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.5.6 | NotificationatEnvMonv2TempAlarmClearedEvent | deprecated | A trap generated when a monitored temperature returns to an acceptable value, having previously been in an alarm condition. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.5.7 | NotificationatEnvMonv2PsbAlarmSetEvent | deprecated | A trap generated when a monitored parameter of a power supply bay device goes out of tolerance. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.5.8 | NotificationatEnvMonv2PsbAlarmClearedEvent | deprecated | A trap generated when a monitored parameter of a power supply bay device returns to an acceptable value, having previously been in an alarm condition. | |
| 1.3.6.1.4.1.207.8.4.4.3.12.6 | TableatEnvMonv2FaultLedTable | not-accessible | current | A table of information detailing any LED fault indications on the device. |
| 1.3.6.1.4.1.207.8.4.4.3.12.6.1 | RowatEnvMonv2FaultLedEntry | not-accessible | current | An entry pertaining to a given fault LED. |
| 1.3.6.1.4.1.207.8.4.4.3.12.6.1.1 | ColumnatEnvMonv2FaultLedStackMemberId | read-only | current | The index of the stack member hosting this fault LED. For a chassis switch, it corresponds to the card ID of the controller that is monitoring the chassis hard… |
| 1.3.6.1.4.1.207.8.4.4.3.12.6.1.2 | ColumnatEnvMonv2FaultLed1Flash | read-only | current | This object indicates whether a fault LED is currently showing a system failure by flashing once. It indicates that one or more heatsink fans have failed, or a… |
| 1.3.6.1.4.1.207.8.4.4.3.12.6.1.3 | ColumnatEnvMonv2FaultLed2Flashes | read-only | current | This object indicates whether a fault LED is currently showing a system failure by flashing twice. It indicates that one or both of the chassis fans are not in… |
| 1.3.6.1.4.1.207.8.4.4.3.12.6.1.4 | ColumnatEnvMonv2FaultLed3Flashes | read-only | current | This object indicates whether a fault LED is currently showing a system failure by flashing three times. It indicates that the ability to monitor temperature o… |
| 1.3.6.1.4.1.207.8.4.4.3.12.6.1.5 | ColumnatEnvMonv2FaultLed4Flashes | read-only | current | This object indicates whether a fault LED is currently showing a system failure by flashing four times. It indicates that an XEM failed to initialise or is inc… |
| 1.3.6.1.4.1.207.8.4.4.3.12.6.1.6 | ColumnatEnvMonv2FaultLed5Flashes | read-only | current | This object indicates whether a fault LED is currently showing a system failure by flashing five times. This flashing sequence is not currently in use. |
| 1.3.6.1.4.1.207.8.4.4.3.12.6.1.7 | ColumnatEnvMonv2FaultLed6Flashes | read-only | current | This object indicates whether a fault LED is currently showing a system failure by flashing six times. It indicates that the device's temperature has exceeded … |
| 1.3.6.1.4.1.207.8.4.4.3.12.7 | TableatEnvMonv2ContactInputTable | not-accessible | current | A table of information about contact inputs available in the device that are monitored by environment monitoring hardware. |
| 1.3.6.1.4.1.207.8.4.4.3.12.7.1 | RowatEnvMonv2ContactInputEntry | not-accessible | current | The description and current state of a contact input. |
| 1.3.6.1.4.1.207.8.4.4.3.12.7.1.1 | ColumnatEnvMonv2ContactInputStackMemberId | read-only | current | The index of the stack member hosting this contact input. |
| 1.3.6.1.4.1.207.8.4.4.3.12.7.1.2 | ColumnatEnvMonv2ContactInputBoardIndex | read-only | current | The index of the board hosting this contact input in the board table. |
| 1.3.6.1.4.1.207.8.4.4.3.12.7.1.3 | ColumnatEnvMonv2ContactInputIndex | read-only | current | The numeric identifier of this contact input on its host board. |
| 1.3.6.1.4.1.207.8.4.4.3.12.7.1.4 | ColumnatEnvMonv2ContactInputDescription | read-only | current | The description of this contact input. |
| 1.3.6.1.4.1.207.8.4.4.3.12.7.1.5 | ColumnatEnvMonv2ContactInputState | read-only | current | An indication of whether this contact input is currently open or closed. |
| 1.3.6.1.4.1.207.8.4.4.3.12.8 | TableatEnvMonv2ContactOutputTable | not-accessible | current | A table of information about contact outputs available in the device that are managed by environment monitoring hardware. |
| 1.3.6.1.4.1.207.8.4.4.3.12.8.1 | RowatEnvMonv2ContactOutputEntry | not-accessible | current | The description and current state of a contact output. |
| 1.3.6.1.4.1.207.8.4.4.3.12.8.1.1 | ColumnatEnvMonv2ContactOutputStackMemberId | read-only | current | The index of the stack member hosting this contact output. |
| 1.3.6.1.4.1.207.8.4.4.3.12.8.1.2 | ColumnatEnvMonv2ContactOutputBoardIndex | read-only | current | The index of the board hosting this contact output in the board table. |
| 1.3.6.1.4.1.207.8.4.4.3.12.8.1.3 | ColumnatEnvMonv2ContactOutputIndex | read-only | current | The numeric identifier of this contact output on its host board. |
| 1.3.6.1.4.1.207.8.4.4.3.12.8.1.4 | ColumnatEnvMonv2ContactOutputDescription | read-only | current | The description of this contact output. |
| 1.3.6.1.4.1.207.8.4.4.3.12.8.1.5 | ColumnatEnvMonv2ContactOutputState | read-only | current | An indication of whether this contact output is currently open or closed. |
| 1.3.6.1.4.1.207.8.4.4.3.12.9 | TableatEnvMonv2ExternalPSUTable | not-accessible | current | Table of external PSU status. |
| 1.3.6.1.4.1.207.8.4.4.3.12.9.1 | RowatEnvMonv2ExternalPSUEntry | not-accessible | current | The description and current status of an external power supply. |
| 1.3.6.1.4.1.207.8.4.4.3.12.9.1.1 | ColumnatEnvMonv2ExternalPSUStackMemberId | read-only | current | The index of the stack member hosting this external PSU. |
| 1.3.6.1.4.1.207.8.4.4.3.12.9.1.2 | ColumnatEnvMonv2ExternalPSUBoardIndex | read-only | current | The index of the board hosting this external PSU in the board table. |
| 1.3.6.1.4.1.207.8.4.4.3.12.9.1.3 | ColumnatEnvMonv2ExternalPSUIndex | read-only | current | The numeric identifier of this external PSU on its host board. |
| 1.3.6.1.4.1.207.8.4.4.3.12.9.1.4 | ColumnatEnvMonv2ExternalPSUDescription | read-only | current | The description of this external PSU. |
| 1.3.6.1.4.1.207.8.4.4.3.12.9.1.5 | ColumnatEnvMonv2ExternalPSUState | read-only | current | An indication of whether the supply potential of the external power supply is present or not. A value of 'failed(1)' indicates that no power is being received … |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| AtEnvMonv2PsbSensorType | INTEGER { psbSensorTypeInvalid(0), fanSpeedDiscrete(1), temperatureDiscrete(2), voltageDiscrete(3), presenceDiscrete(4) } | current | Indicates the type of a Power Supply Bay Device sensor. |