AT-ENVMONv2-MIB

65 objects
The AT Environment Monitoring v2 MIB for managing and reporting data relating to voltage rails, fan speeds, temperature sensors and power supply units.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.207.8.4.4.3.12IdentityatEnvMonv2The AT Environment Monitoring v2 MIB for managing and reporting data relating to voltage rails, fan speeds, temperature sensors and power supply units.
1.3.6.1.4.1.207.8.4.4.3.12.1TableatEnvMonv2FanTablenot-accessiblecurrentA table of information about fans installed in the device that have their fan speeds monitored by environment monitoring hardware.
1.3.6.1.4.1.207.8.4.4.3.12.1.1RowatEnvMonv2FanEntrynot-accessiblecurrentThe description, current speed, lower threshold speed and current status of a fan.
1.3.6.1.4.1.207.8.4.4.3.12.1.1.1ColumnatEnvMonv2FanStackMemberIdread-onlycurrentThe index of the stack member hosting this fan.
1.3.6.1.4.1.207.8.4.4.3.12.1.1.2ColumnatEnvMonv2FanBoardIndexread-onlycurrentThe index of the board hosting this fan in the board table.
1.3.6.1.4.1.207.8.4.4.3.12.1.1.3ColumnatEnvMonv2FanIndexread-onlycurrentThe numeric identifier of this fan on its host board.
1.3.6.1.4.1.207.8.4.4.3.12.1.1.4ColumnatEnvMonv2FanDescriptionread-onlycurrentThe description of this fan.
1.3.6.1.4.1.207.8.4.4.3.12.1.1.5ColumnatEnvMonv2FanCurrentSpeedread-onlycurrentThe current speed of this fan in revolutions per minute.
1.3.6.1.4.1.207.8.4.4.3.12.1.1.6ColumnatEnvMonv2FanLowerThresholdread-onlycurrentThe minimum acceptable speed of the fan in revolutions per minute.
1.3.6.1.4.1.207.8.4.4.3.12.1.1.7ColumnatEnvMonv2FanStatusread-onlycurrentAn indication of whether this fan is currently in an alarm condition. A value of 'failed' indicates that its current speed is too low, 'good' indicates that th…
1.3.6.1.4.1.207.8.4.4.3.12.2TableatEnvMonv2VoltageTablenot-accessiblecurrentA table of information about voltage rails in the device that are monitored by environment monitoring hardware.
1.3.6.1.4.1.207.8.4.4.3.12.2.1RowatEnvMonv2VoltageEntrynot-accessiblecurrentThe description, current value, upper & lower threshold settings and current status of a voltage rail.
1.3.6.1.4.1.207.8.4.4.3.12.2.1.1ColumnatEnvMonv2VoltageStackMemberIdread-onlycurrentThe index of the stack member hosting this voltage sensor.
1.3.6.1.4.1.207.8.4.4.3.12.2.1.2ColumnatEnvMonv2VoltageBoardIndexread-onlycurrentThe index of the board hosting this voltage sensor in the board table.
1.3.6.1.4.1.207.8.4.4.3.12.2.1.3ColumnatEnvMonv2VoltageIndexread-onlycurrentThe numeric identifier of this voltage rail on its host board.
1.3.6.1.4.1.207.8.4.4.3.12.2.1.4ColumnatEnvMonv2VoltageDescriptionread-onlycurrentThe description of this voltage rail.
1.3.6.1.4.1.207.8.4.4.3.12.2.1.5ColumnatEnvMonv2VoltageCurrentread-onlycurrentThe current reading of this voltage rail in millivolts.
1.3.6.1.4.1.207.8.4.4.3.12.2.1.6ColumnatEnvMonv2VoltageUpperThresholdread-onlycurrentThe maximum acceptable reading of this voltage rail in millivolts.
1.3.6.1.4.1.207.8.4.4.3.12.2.1.7ColumnatEnvMonv2VoltageLowerThresholdread-onlycurrentThe minimum acceptable reading of this voltage rail in millivolts.
1.3.6.1.4.1.207.8.4.4.3.12.2.1.8ColumnatEnvMonv2VoltageStatusread-onlycurrentAn indication of whether this voltage rail is currently in an alarm condition. A value of 'outOfRange' indicates that its current reading is outside its thresh…
1.3.6.1.4.1.207.8.4.4.3.12.3TableatEnvMonv2TemperatureTablenot-accessiblecurrentA table of information about temperature sensors in the device that are monitored by environment monitoring hardware.
1.3.6.1.4.1.207.8.4.4.3.12.3.1RowatEnvMonv2TemperatureEntrynot-accessiblecurrentThe description, current value, upper threshold setting and current status of a temperature sensor.
1.3.6.1.4.1.207.8.4.4.3.12.3.1.1ColumnatEnvMonv2TemperatureStackMemberIdread-onlycurrentThe index of the stack member hosting this temperature sensor.
1.3.6.1.4.1.207.8.4.4.3.12.3.1.2ColumnatEnvMonv2TemperatureBoardIndexread-onlycurrentThe index of the board hosting this temperature sensor in the board table.
1.3.6.1.4.1.207.8.4.4.3.12.3.1.3ColumnatEnvMonv2TemperatureIndexread-onlycurrentThe numeric identifier of this temperature sensor on its host board.
1.3.6.1.4.1.207.8.4.4.3.12.3.1.4ColumnatEnvMonv2TemperatureDescriptionread-onlycurrentThe description of this temperature sensor.
1.3.6.1.4.1.207.8.4.4.3.12.3.1.5ColumnatEnvMonv2TemperatureCurrentread-onlycurrentThe current reading of this temperature sensor in tenths of a degree Celsius.
1.3.6.1.4.1.207.8.4.4.3.12.3.1.6ColumnatEnvMonv2TemperatureUpperThresholdread-onlycurrentThe maximum acceptable reading of this temperature sensor in tenths of a degree Celsius.
1.3.6.1.4.1.207.8.4.4.3.12.3.1.7ColumnatEnvMonv2TemperatureStatusread-onlycurrentAn indication of whether this temperature sensor is currently in an alarm condition. A value of 'outOfRange' indicates that its current reading is outside its …
1.3.6.1.4.1.207.8.4.4.3.12.4NodeatEnvMonv2PsbObjects
1.3.6.1.4.1.207.8.4.4.3.12.4.1TableatEnvMonv2PsbTablenot-accessiblecurrentA table of information about power supply bays in the system and any devices that are installed.
1.3.6.1.4.1.207.8.4.4.3.12.4.1.1RowatEnvMonv2PsbEntrynot-accessiblecurrentThe description and current status of a power supply bay device.
1.3.6.1.4.1.207.8.4.4.3.12.4.1.1.1ColumnatEnvMonv2PsbHostStackMemberIdread-onlycurrentThe index of the stack member hosting this power supply bay.
1.3.6.1.4.1.207.8.4.4.3.12.4.1.1.2ColumnatEnvMonv2PsbHostBoardIndexread-onlycurrentThe index of the board hosting this power supply bay in the board table.
1.3.6.1.4.1.207.8.4.4.3.12.4.1.1.3ColumnatEnvMonv2PsbHostSlotIndexread-onlycurrentThe index of this power supply bay on its host board. This index is fixed for each slot, on each type of board.
1.3.6.1.4.1.207.8.4.4.3.12.4.1.1.4ColumnatEnvMonv2PsbHeldBoardIndexread-onlycurrentThe index of a board installed in this power supply bay. This value corresponds to atEnvMonv2PsbSensorBoardIndex for each sensor on this board. A value of 0 in…
1.3.6.1.4.1.207.8.4.4.3.12.4.1.1.5ColumnatEnvMonv2PsbHeldBoardIdread-onlycurrentThe type of board installed in this power supply bay. The values of this object are taken from the pprXxx object IDs under the boards sub-tree in the parent MI…
1.3.6.1.4.1.207.8.4.4.3.12.4.1.1.6ColumnatEnvMonv2PsbDescriptionread-onlycurrentThe description of this power supply bay.
1.3.6.1.4.1.207.8.4.4.3.12.4.2TableatEnvMonv2PsbSensorTablenot-accessiblecurrentA table of information about environment monitoring sensors on devices installed in power supply bays.
1.3.6.1.4.1.207.8.4.4.3.12.4.2.1RowatEnvMonv2PsbSensorEntrynot-accessiblecurrentThe description and current status of a device installed in a power supply bay.
1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.1ColumnatEnvMonv2PsbSensorStackMemberIdread-onlycurrentThe index of the stack member hosting this sensor.
1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.2ColumnatEnvMonv2PsbSensorBoardIndexread-onlycurrentThe index of the board hosting this sensor in the board table.
1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.3ColumnatEnvMonv2PsbSensorIndexread-onlycurrentThe index of this power supply bay environmental sensor on its host board.
1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.4ColumnatEnvMonv2PsbSensorTyperead-onlycurrentThe type of environmental variable this sensor detects.
1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.5ColumnatEnvMonv2PsbSensorDescriptionread-onlycurrentThe description of this power supply bay environmental sensor.
1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.6ColumnatEnvMonv2PsbSensorStatusread-onlycurrentAn indication of whether this environmental sensor is currently in an alarm condition. A value of 'failed' indicates that the device is in a failure condition,…
1.3.6.1.4.1.207.8.4.4.3.12.5NodeatEnvMonv2Traps
1.3.6.1.4.1.207.8.4.4.3.12.5.1NotificationatEnvMonv2FanAlarmSetEventcurrentA trap generated when the monitored speed of a fan drops below its lower threshold.
1.3.6.1.4.1.207.8.4.4.3.12.5.2NotificationatEnvMonv2FanAlarmClearedEventcurrentA trap generated when the monitored speed of a fan returns to an acceptable value, the fan having previously been in an alarm condition.
1.3.6.1.4.1.207.8.4.4.3.12.5.3NotificationatEnvMonv2VoltAlarmSetEventcurrentA trap generated when the voltage of a monitored voltage rail goes out of tolerance, either by dropping below its lower threshold, or exceeding its upper thres…
1.3.6.1.4.1.207.8.4.4.3.12.5.4NotificationatEnvMonv2VoltAlarmClearedEventcurrentA trap generated when the voltage of a monitored voltage rail returns to an acceptable value, having previously been in an alarm condition.
1.3.6.1.4.1.207.8.4.4.3.12.5.5NotificationatEnvMonv2TempAlarmSetEventcurrentA trap generated when a monitored temperature exceeds its upper threshold.
1.3.6.1.4.1.207.8.4.4.3.12.5.6NotificationatEnvMonv2TempAlarmClearedEventcurrentA trap generated when a monitored temperature returns to an acceptable value, having previously been in an alarm condition.
1.3.6.1.4.1.207.8.4.4.3.12.5.7NotificationatEnvMonv2PsbAlarmSetEventcurrentA trap generated when a monitored parameter of a power supply bay device goes out of tolerance.
1.3.6.1.4.1.207.8.4.4.3.12.5.8NotificationatEnvMonv2PsbAlarmClearedEventcurrentA trap generated when a monitored parameter of a power supply bay device returns to an acceptable value, having previously been in an alarm condition.
1.3.6.1.4.1.207.8.4.4.3.12.6TableatEnvMonv2FaultLedTablenot-accessiblecurrentA table of information detailing any LED fault indications on the device.
1.3.6.1.4.1.207.8.4.4.3.12.6.1RowatEnvMonv2FaultLedEntrynot-accessiblecurrentAn entry pertaining to a given fault LED.
1.3.6.1.4.1.207.8.4.4.3.12.6.1.1ColumnatEnvMonv2FaultLedStackMemberIdread-onlycurrentThe index of the stack member hosting this fault LED.
1.3.6.1.4.1.207.8.4.4.3.12.6.1.2ColumnatEnvMonv2FaultLed1Flashread-onlycurrentThis object indicates whether a fault LED is currently showing a system failure by flashing once. It indicates that one or more heatsink fans have failed, or a…
1.3.6.1.4.1.207.8.4.4.3.12.6.1.3ColumnatEnvMonv2FaultLed2Flashesread-onlycurrentThis object indicates whether a fault LED is currently showing a system failure by flashing twice. It indicates that one or both of the chassis fans are not in…
1.3.6.1.4.1.207.8.4.4.3.12.6.1.4ColumnatEnvMonv2FaultLed3Flashesread-onlycurrentThis object indicates whether a fault LED is currently showing a system failure by flashing three times. It indicates that the ability to monitor temperature o…
1.3.6.1.4.1.207.8.4.4.3.12.6.1.5ColumnatEnvMonv2FaultLed4Flashesread-onlycurrentThis object indicates whether a fault LED is currently showing a system failure by flashing four times. It indicates that an XEM failed to initialise or is inc…
1.3.6.1.4.1.207.8.4.4.3.12.6.1.6ColumnatEnvMonv2FaultLed5Flashesread-onlycurrentThis object indicates whether a fault LED is currently showing a system failure by flashing five times. This flashing sequence is not currently in use.
1.3.6.1.4.1.207.8.4.4.3.12.6.1.7ColumnatEnvMonv2FaultLed6Flashesread-onlycurrentThis object indicates whether a fault LED is currently showing a system failure by flashing six times. It indicates that the device's temperature has exceeded …
Type Definitions
NameSyntaxStatusDescription
AtEnvMonv2PsbSensorTypeINTEGER { psbSensorTypeInvalid(0), fanSpeedDiscrete(1), temperatureDiscrete(2), voltageDiscrete(3) }currentIndicates the type of a Power Supply Bay Device sensor.