AT-ENVMONv2-MIB

107 objects
The AT Environment Monitoring v2 MIB for managing and reporting data relating to voltage rails, fan speeds, temperature sensors and power supply units.
Imported Objects
AT-SMI-MIBDisplayStringUnsized
AT-SYSINFO-MIBsysinfo
SNMPv2-SMIMODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCTEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.4.1.207.8.4.4.3.12IdentityatEnvMonv2The AT Environment Monitoring v2 MIB for managing and reporting data relating to voltage rails, fan speeds, temperature sensors and power supply units.
1.3.6.1.4.1.207.8.4.4.3.12.0NodeatEnvMonv2Notifications
1.3.6.1.4.1.207.8.4.4.3.12.0.1NotificationatEnvMonv2FanAlarmSetNotifycurrentA notification generated when the monitored speed of a fan drops below its lower threshold.
1.3.6.1.4.1.207.8.4.4.3.12.0.2NotificationatEnvMonv2FanAlarmClearedNotifycurrentA notification generated when the monitored speed of a fan returns to an acceptable value, the fan having previously been in an alarm condition.
1.3.6.1.4.1.207.8.4.4.3.12.0.3NotificationatEnvMonv2VoltAlarmSetNotifycurrentA notification generated when the voltage of a monitored voltage rail goes out of tolerance, either by dropping below its lower threshold, or exceeding its upp…
1.3.6.1.4.1.207.8.4.4.3.12.0.4NotificationatEnvMonv2VoltAlarmClearedNotifycurrentA notification generated when the voltage of a monitored voltage rail returns to an acceptable value, having previously been in an alarm condition.
1.3.6.1.4.1.207.8.4.4.3.12.0.5NotificationatEnvMonv2TempAlarmSetNotifycurrentA notification generated when a monitored temperature exceeds its upper threshold.
1.3.6.1.4.1.207.8.4.4.3.12.0.6NotificationatEnvMonv2TempAlarmClearedNotifycurrentA notification generated when a monitored temperature returns to an acceptable value, having previously been in an alarm condition.
1.3.6.1.4.1.207.8.4.4.3.12.0.7NotificationatEnvMonv2PsbAlarmSetNotifycurrentA notification generated when a monitored parameter of a power supply bay device goes out of tolerance.
1.3.6.1.4.1.207.8.4.4.3.12.0.8NotificationatEnvMonv2PsbAlarmClearedNotifycurrentA notification generated when a monitored parameter of a power supply bay device returns to an acceptable value, having previously been in an alarm condition.
1.3.6.1.4.1.207.8.4.4.3.12.0.9NotificationatEnvMonv2ContactInputOpenNotifycurrentA notification generated when a monitored contact input opens.
1.3.6.1.4.1.207.8.4.4.3.12.0.10NotificationatEnvMonv2ContactInputCloseNotifycurrentA notification generated when a monitored contact input closes.
1.3.6.1.4.1.207.8.4.4.3.12.0.11NotificationatEnvMonv2ExternalPSUAlarmSetNotifycurrentA notification generated when supply potential of a monitored external power supply is not present.
1.3.6.1.4.1.207.8.4.4.3.12.0.12NotificationatEnvMonv2ExternalPSUAlarmClearedNotifycurrentA notification generated when supply potential of a monitored external power supply returns to an acceptable value, having previously been in an alarm conditio…
1.3.6.1.4.1.207.8.4.4.3.12.0.13NotificationatEnvMonv2TempCriticalSetNotifycurrentA notification generated when a monitored temperature exceeds its upper threshold.
1.3.6.1.4.1.207.8.4.4.3.12.0.14NotificationatEnvMonv2TempCriticalClearedNotifycurrentA notification generated when a monitored temperature returns to an acceptable value, having previously been in an alarm condition.
1.3.6.1.4.1.207.8.4.4.3.12.0.15NotificationatEnvMonv2TempCriticalLevel1SetNotifycurrentA notification generated when a monitored temperature exceeds the level 1 threshold.
1.3.6.1.4.1.207.8.4.4.3.12.0.16NotificationatEnvMonv2TempCriticalLevel1ClearedNotifycurrentA notification generated when a monitored temperature returns to an acceptable value, having previously been in critical temperature level 1 condition.
1.3.6.1.4.1.207.8.4.4.3.12.0.17NotificationatEnvMonv2TempCriticalLevel2SetNotifycurrentA notification generated when a monitored temperature exceeds the level 2 threshold.
1.3.6.1.4.1.207.8.4.4.3.12.0.18NotificationatEnvMonv2TempCriticalLevel2ClearedNotifycurrentA notification generated when a monitored temperature returns to an acceptable value, having previously been in critical temperature level 2 condition.
1.3.6.1.4.1.207.8.4.4.3.12.0.19NotificationatEnvMonv2PsbPresenceChangeNotifycurrentA notification generated when an insertion or removal event is detected on a power supply bay device.
1.3.6.1.4.1.207.8.4.4.3.12.1TableatEnvMonv2FanTablenot-accessiblecurrentA table of information about fans installed in the device that have their fan speeds monitored by environment monitoring hardware.
1.3.6.1.4.1.207.8.4.4.3.12.1.1RowatEnvMonv2FanEntrynot-accessiblecurrentThe description, current speed, lower threshold speed and current status of a fan.
1.3.6.1.4.1.207.8.4.4.3.12.1.1.1ColumnatEnvMonv2FanStackMemberIdread-onlycurrentThe index of the stack member hosting this fan. For a chassis switch, it corresponds to the card ID of the controller that is monitoring the chassis hardware, …
1.3.6.1.4.1.207.8.4.4.3.12.1.1.2ColumnatEnvMonv2FanBoardIndexread-onlycurrentThe index of the board hosting this fan in the board table.
1.3.6.1.4.1.207.8.4.4.3.12.1.1.3ColumnatEnvMonv2FanIndexread-onlycurrentThe numeric identifier of this fan on its host board.
1.3.6.1.4.1.207.8.4.4.3.12.1.1.4ColumnatEnvMonv2FanDescriptionread-onlycurrentThe description of this fan.
1.3.6.1.4.1.207.8.4.4.3.12.1.1.5ColumnatEnvMonv2FanCurrentSpeedread-onlycurrentThe current speed of this fan in revolutions per minute.
1.3.6.1.4.1.207.8.4.4.3.12.1.1.6ColumnatEnvMonv2FanLowerThresholdread-onlycurrentThe minimum acceptable speed of the fan in revolutions per minute.
1.3.6.1.4.1.207.8.4.4.3.12.1.1.7ColumnatEnvMonv2FanStatusread-onlycurrentAn indication of whether this fan is currently in an alarm condition. A value of 'failed(1)' indicates that its current speed is too low, 'good(2)' indicates t…
1.3.6.1.4.1.207.8.4.4.3.12.2TableatEnvMonv2VoltageTablenot-accessiblecurrentA table of information about voltage rails in the device that are monitored by environment monitoring hardware.
1.3.6.1.4.1.207.8.4.4.3.12.2.1RowatEnvMonv2VoltageEntrynot-accessiblecurrentThe description, current value, upper & lower threshold settings and current status of a voltage rail.
1.3.6.1.4.1.207.8.4.4.3.12.2.1.1ColumnatEnvMonv2VoltageStackMemberIdread-onlycurrentThe index of the stack member hosting this voltage sensor. For a chassis switch, it corresponds to the card ID of the controller that is monitoring the chassis…
1.3.6.1.4.1.207.8.4.4.3.12.2.1.2ColumnatEnvMonv2VoltageBoardIndexread-onlycurrentThe index of the board hosting this voltage sensor in the board table.
1.3.6.1.4.1.207.8.4.4.3.12.2.1.3ColumnatEnvMonv2VoltageIndexread-onlycurrentThe numeric identifier of this voltage rail on its host board.
1.3.6.1.4.1.207.8.4.4.3.12.2.1.4ColumnatEnvMonv2VoltageDescriptionread-onlycurrentThe description of this voltage rail.
1.3.6.1.4.1.207.8.4.4.3.12.2.1.5ColumnatEnvMonv2VoltageCurrentread-onlycurrentThe current reading of this voltage rail in millivolts.
1.3.6.1.4.1.207.8.4.4.3.12.2.1.6ColumnatEnvMonv2VoltageUpperThresholdread-onlycurrentThe maximum acceptable reading of this voltage rail in millivolts.
1.3.6.1.4.1.207.8.4.4.3.12.2.1.7ColumnatEnvMonv2VoltageLowerThresholdread-onlycurrentThe minimum acceptable reading of this voltage rail in millivolts.
1.3.6.1.4.1.207.8.4.4.3.12.2.1.8ColumnatEnvMonv2VoltageStatusread-onlycurrentAn indication of whether this voltage rail is currently in an alarm condition. A value of 'outOfRange' indicates that its current reading is outside its thresh…
1.3.6.1.4.1.207.8.4.4.3.12.3TableatEnvMonv2TemperatureTablenot-accessiblecurrentA table of information about temperature sensors in the device that are monitored by environment monitoring hardware.
1.3.6.1.4.1.207.8.4.4.3.12.3.1RowatEnvMonv2TemperatureEntrynot-accessiblecurrentThe description, current value, upper threshold setting and current status of a temperature sensor.
1.3.6.1.4.1.207.8.4.4.3.12.3.1.1ColumnatEnvMonv2TemperatureStackMemberIdread-onlycurrentThe index of the stack member hosting this temperature sensor. For a chassis switch, it corresponds to the card ID of the controller that is monitoring the cha…
1.3.6.1.4.1.207.8.4.4.3.12.3.1.2ColumnatEnvMonv2TemperatureBoardIndexread-onlycurrentThe index of the board hosting this temperature sensor in the board table.
1.3.6.1.4.1.207.8.4.4.3.12.3.1.3ColumnatEnvMonv2TemperatureIndexread-onlycurrentThe numeric identifier of this temperature sensor on its host board.
1.3.6.1.4.1.207.8.4.4.3.12.3.1.4ColumnatEnvMonv2TemperatureDescriptionread-onlycurrentThe description of this temperature sensor.
1.3.6.1.4.1.207.8.4.4.3.12.3.1.5ColumnatEnvMonv2TemperatureCurrentread-onlycurrentThe current reading of this temperature sensor in tenths of a degree Celsius.
1.3.6.1.4.1.207.8.4.4.3.12.3.1.6ColumnatEnvMonv2TemperatureUpperThresholdread-onlycurrentThe maximum acceptable reading of this temperature sensor in tenths of a degree Celsius.
1.3.6.1.4.1.207.8.4.4.3.12.3.1.7ColumnatEnvMonv2TemperatureStatusread-onlycurrentAn indication of whether this temperature sensor is currently in an alarm condition. A value of 'outOfRange' indicates that its current reading is outside its …
1.3.6.1.4.1.207.8.4.4.3.12.4NodeatEnvMonv2PsbObjects
1.3.6.1.4.1.207.8.4.4.3.12.4.1TableatEnvMonv2PsbTablenot-accessiblecurrentA table of information about power supply bays in the system and any devices that are installed.
1.3.6.1.4.1.207.8.4.4.3.12.4.1.1RowatEnvMonv2PsbEntrynot-accessiblecurrentThe description and current status of a power supply bay device.
1.3.6.1.4.1.207.8.4.4.3.12.4.1.1.1ColumnatEnvMonv2PsbHostStackMemberIdread-onlycurrentThe index of the stack member hosting this power supply bay. For a chassis switch, it corresponds to the card ID of the controller that is monitoring the chass…
1.3.6.1.4.1.207.8.4.4.3.12.4.1.1.2ColumnatEnvMonv2PsbHostBoardIndexread-onlycurrentThe index of the board hosting this power supply bay in the board table.
1.3.6.1.4.1.207.8.4.4.3.12.4.1.1.3ColumnatEnvMonv2PsbHostSlotIndexread-onlycurrentThe index of this power supply bay on its host board. This index is fixed for each slot, on each type of board.
1.3.6.1.4.1.207.8.4.4.3.12.4.1.1.4ColumnatEnvMonv2PsbHeldBoardIndexread-onlycurrentThe index of a board installed in this power supply bay. This value corresponds to atEnvMonv2PsbSensorBoardIndex for each sensor on this board. A value of 0 in…
1.3.6.1.4.1.207.8.4.4.3.12.4.1.1.5ColumnatEnvMonv2PsbHeldBoardIdread-onlycurrentThe type of board installed in this power supply bay. The values of this object are taken from the pprXxx object IDs under the boards sub-tree in the parent MI…
1.3.6.1.4.1.207.8.4.4.3.12.4.1.1.6ColumnatEnvMonv2PsbDescriptionread-onlycurrentThe description of this power supply bay.
1.3.6.1.4.1.207.8.4.4.3.12.4.2TableatEnvMonv2PsbSensorTablenot-accessiblecurrentA table of information about environment monitoring sensors on devices installed in power supply bays.
1.3.6.1.4.1.207.8.4.4.3.12.4.2.1RowatEnvMonv2PsbSensorEntrynot-accessiblecurrentThe description and current status of a device installed in a power supply bay.
1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.1ColumnatEnvMonv2PsbSensorStackMemberIdread-onlycurrentThe index of the stack member hosting this sensor. For a chassis switch, it corresponds to the card ID of the controller that is monitoring the chassis hardwar…
1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.2ColumnatEnvMonv2PsbSensorBoardIndexread-onlycurrentThe index of the board hosting this sensor in the board table.
1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.3ColumnatEnvMonv2PsbSensorIndexread-onlycurrentThe index of this power supply bay environmental sensor on its host board.
1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.4ColumnatEnvMonv2PsbSensorTyperead-onlycurrentThe type of environmental variable this sensor detects.
1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.5ColumnatEnvMonv2PsbSensorDescriptionread-onlycurrentThe description of this power supply bay environmental sensor.
1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.6ColumnatEnvMonv2PsbSensorStatusread-onlycurrentAn indication of whether this environmental sensor is currently in an alarm condition. A value of 'failed(1)' indicates that the device is in a failure conditi…
1.3.6.1.4.1.207.8.4.4.3.12.4.2.1.7ColumnatEnvMonv2PsbSensorReadingread-onlycurrentAn indication of whether this environmental sensor is currently reading a value for the monitored device. A value of 'no' indicates that there is no current re…
1.3.6.1.4.1.207.8.4.4.3.12.5NodeatEnvMonv2Traps
1.3.6.1.4.1.207.8.4.4.3.12.5.1NotificationatEnvMonv2FanAlarmSetEventdeprecatedA trap generated when the monitored speed of a fan drops below its lower threshold.
1.3.6.1.4.1.207.8.4.4.3.12.5.2NotificationatEnvMonv2FanAlarmClearedEventdeprecatedA trap generated when the monitored speed of a fan returns to an acceptable value, the fan having previously been in an alarm condition.
1.3.6.1.4.1.207.8.4.4.3.12.5.3NotificationatEnvMonv2VoltAlarmSetEventdeprecatedA trap generated when the voltage of a monitored voltage rail goes out of tolerance, either by dropping below its lower threshold, or exceeding its upper thres…
1.3.6.1.4.1.207.8.4.4.3.12.5.4NotificationatEnvMonv2VoltAlarmClearedEventdeprecatedA trap generated when the voltage of a monitored voltage rail returns to an acceptable value, having previously been in an alarm condition.
1.3.6.1.4.1.207.8.4.4.3.12.5.5NotificationatEnvMonv2TempAlarmSetEventdeprecatedA trap generated when a monitored temperature exceeds its upper threshold.
1.3.6.1.4.1.207.8.4.4.3.12.5.6NotificationatEnvMonv2TempAlarmClearedEventdeprecatedA trap generated when a monitored temperature returns to an acceptable value, having previously been in an alarm condition.
1.3.6.1.4.1.207.8.4.4.3.12.5.7NotificationatEnvMonv2PsbAlarmSetEventdeprecatedA trap generated when a monitored parameter of a power supply bay device goes out of tolerance.
1.3.6.1.4.1.207.8.4.4.3.12.5.8NotificationatEnvMonv2PsbAlarmClearedEventdeprecatedA trap generated when a monitored parameter of a power supply bay device returns to an acceptable value, having previously been in an alarm condition.
1.3.6.1.4.1.207.8.4.4.3.12.6TableatEnvMonv2FaultLedTablenot-accessiblecurrentA table of information detailing any LED fault indications on the device.
1.3.6.1.4.1.207.8.4.4.3.12.6.1RowatEnvMonv2FaultLedEntrynot-accessiblecurrentAn entry pertaining to a given fault LED.
1.3.6.1.4.1.207.8.4.4.3.12.6.1.1ColumnatEnvMonv2FaultLedStackMemberIdread-onlycurrentThe index of the stack member hosting this fault LED. For a chassis switch, it corresponds to the card ID of the controller that is monitoring the chassis hard…
1.3.6.1.4.1.207.8.4.4.3.12.6.1.2ColumnatEnvMonv2FaultLed1Flashread-onlycurrentThis object indicates whether a fault LED is currently showing a system failure by flashing once. It indicates that one or more heatsink fans have failed, or a…
1.3.6.1.4.1.207.8.4.4.3.12.6.1.3ColumnatEnvMonv2FaultLed2Flashesread-onlycurrentThis object indicates whether a fault LED is currently showing a system failure by flashing twice. It indicates that one or both of the chassis fans are not in…
1.3.6.1.4.1.207.8.4.4.3.12.6.1.4ColumnatEnvMonv2FaultLed3Flashesread-onlycurrentThis object indicates whether a fault LED is currently showing a system failure by flashing three times. It indicates that the ability to monitor temperature o…
1.3.6.1.4.1.207.8.4.4.3.12.6.1.5ColumnatEnvMonv2FaultLed4Flashesread-onlycurrentThis object indicates whether a fault LED is currently showing a system failure by flashing four times. It indicates that an XEM failed to initialise or is inc…
1.3.6.1.4.1.207.8.4.4.3.12.6.1.6ColumnatEnvMonv2FaultLed5Flashesread-onlycurrentThis object indicates whether a fault LED is currently showing a system failure by flashing five times. This flashing sequence is not currently in use.
1.3.6.1.4.1.207.8.4.4.3.12.6.1.7ColumnatEnvMonv2FaultLed6Flashesread-onlycurrentThis object indicates whether a fault LED is currently showing a system failure by flashing six times. It indicates that the device's temperature has exceeded …
1.3.6.1.4.1.207.8.4.4.3.12.7TableatEnvMonv2ContactInputTablenot-accessiblecurrentA table of information about contact inputs available in the device that are monitored by environment monitoring hardware.
1.3.6.1.4.1.207.8.4.4.3.12.7.1RowatEnvMonv2ContactInputEntrynot-accessiblecurrentThe description and current state of a contact input.
1.3.6.1.4.1.207.8.4.4.3.12.7.1.1ColumnatEnvMonv2ContactInputStackMemberIdread-onlycurrentThe index of the stack member hosting this contact input.
1.3.6.1.4.1.207.8.4.4.3.12.7.1.2ColumnatEnvMonv2ContactInputBoardIndexread-onlycurrentThe index of the board hosting this contact input in the board table.
1.3.6.1.4.1.207.8.4.4.3.12.7.1.3ColumnatEnvMonv2ContactInputIndexread-onlycurrentThe numeric identifier of this contact input on its host board.
1.3.6.1.4.1.207.8.4.4.3.12.7.1.4ColumnatEnvMonv2ContactInputDescriptionread-onlycurrentThe description of this contact input.
1.3.6.1.4.1.207.8.4.4.3.12.7.1.5ColumnatEnvMonv2ContactInputStateread-onlycurrentAn indication of whether this contact input is currently open or closed.
1.3.6.1.4.1.207.8.4.4.3.12.8TableatEnvMonv2ContactOutputTablenot-accessiblecurrentA table of information about contact outputs available in the device that are managed by environment monitoring hardware.
1.3.6.1.4.1.207.8.4.4.3.12.8.1RowatEnvMonv2ContactOutputEntrynot-accessiblecurrentThe description and current state of a contact output.
1.3.6.1.4.1.207.8.4.4.3.12.8.1.1ColumnatEnvMonv2ContactOutputStackMemberIdread-onlycurrentThe index of the stack member hosting this contact output.
1.3.6.1.4.1.207.8.4.4.3.12.8.1.2ColumnatEnvMonv2ContactOutputBoardIndexread-onlycurrentThe index of the board hosting this contact output in the board table.
1.3.6.1.4.1.207.8.4.4.3.12.8.1.3ColumnatEnvMonv2ContactOutputIndexread-onlycurrentThe numeric identifier of this contact output on its host board.
1.3.6.1.4.1.207.8.4.4.3.12.8.1.4ColumnatEnvMonv2ContactOutputDescriptionread-onlycurrentThe description of this contact output.
1.3.6.1.4.1.207.8.4.4.3.12.8.1.5ColumnatEnvMonv2ContactOutputStateread-onlycurrentAn indication of whether this contact output is currently open or closed.
1.3.6.1.4.1.207.8.4.4.3.12.9TableatEnvMonv2ExternalPSUTablenot-accessiblecurrentTable of external PSU status.
1.3.6.1.4.1.207.8.4.4.3.12.9.1RowatEnvMonv2ExternalPSUEntrynot-accessiblecurrentThe description and current status of an external power supply.
1.3.6.1.4.1.207.8.4.4.3.12.9.1.1ColumnatEnvMonv2ExternalPSUStackMemberIdread-onlycurrentThe index of the stack member hosting this external PSU.
1.3.6.1.4.1.207.8.4.4.3.12.9.1.2ColumnatEnvMonv2ExternalPSUBoardIndexread-onlycurrentThe index of the board hosting this external PSU in the board table.
1.3.6.1.4.1.207.8.4.4.3.12.9.1.3ColumnatEnvMonv2ExternalPSUIndexread-onlycurrentThe numeric identifier of this external PSU on its host board.
1.3.6.1.4.1.207.8.4.4.3.12.9.1.4ColumnatEnvMonv2ExternalPSUDescriptionread-onlycurrentThe description of this external PSU.
1.3.6.1.4.1.207.8.4.4.3.12.9.1.5ColumnatEnvMonv2ExternalPSUStateread-onlycurrentAn indication of whether the supply potential of the external power supply is present or not. A value of 'failed(1)' indicates that no power is being received …
Type Definitions
NameSyntaxStatusDescription
AtEnvMonv2PsbSensorTypeINTEGER { psbSensorTypeInvalid(0), fanSpeedDiscrete(1), temperatureDiscrete(2), voltageDiscrete(3), presenceDiscrete(4) }currentIndicates the type of a Power Supply Bay Device sensor.