AT-FIBER-MONITORING-MIB
25 objects
This MIB contains managed objects definition and notification definitions for AT Fiber Monitoring feature.
Imported Objects
| AT-SYSINFO-MIB | sysinfo |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.207.8.4.4.3.27 | IdentityatFiberMon | This MIB contains managed objects definition and notification definitions for AT Fiber Monitoring feature. | ||
| 1.3.6.1.4.1.207.8.4.4.3.27.0 | NodeatFiberMonNotifications | |||
| 1.3.6.1.4.1.207.8.4.4.3.27.0.1 | NotificationatFiberMonAlarmSetNotify | current | A notification generated when the monitored received optical power of an SFP goes outside its alarm threshold. | |
| 1.3.6.1.4.1.207.8.4.4.3.27.0.2 | NotificationatFiberMonAlarmClearedNotify | current | A notification generated when the monitored received optical power of an SFP returns to an acceptable value. This can occur because the power has returned to i… | |
| 1.3.6.1.4.1.207.8.4.4.3.27.1 | NodeatFiberMonTrapVariable | |||
| 1.3.6.1.4.1.207.8.4.4.3.27.1.1 | ScalaratFiberMonReading | accessible-for-notify | current | The current received optical power reading for the port specified in the trap (x0.0001mW) |
| 1.3.6.1.4.1.207.8.4.4.3.27.2 | TableatFiberMonConfigTable | not-accessible | current | It contains the objects used to configure the operation of fiber monitoring. |
| 1.3.6.1.4.1.207.8.4.4.3.27.2.1 | RowatFiberMonConfigEntry | not-accessible | current | Entry for the table. It contains the configurables of fiber monitering for an interface. |
| 1.3.6.1.4.1.207.8.4.4.3.27.2.1.1 | ColumnatFiberMonIfname | read-write | current | The name of the interface where the pluggable is in. |
| 1.3.6.1.4.1.207.8.4.4.3.27.2.1.2 | ColumnatFiberMonEnable | read-write | current | Enable or disable fiber monitoring. |
| 1.3.6.1.4.1.207.8.4.4.3.27.2.1.3 | ColumnatFiberMonInterval | read-write | current | Fiber monitoring polling interval in seconds. |
| 1.3.6.1.4.1.207.8.4.4.3.27.2.1.4 | ColumnatFiberMonSensitivity | read-write | current | The sensitivity for fiber monitoring. Acceptable mode strings and value ranges are as below: low - 2dB medium - 1dB high - 0.5dB highest - 0.0025mW fixed <25 -… |
| 1.3.6.1.4.1.207.8.4.4.3.27.2.1.5 | ColumnatFiberMonBaseline | read-write | current | The baseline value for firber mornitoring. Acceptable mode string and value ranges are as below: average <12-150> - number of readings used to calculate moving… |
| 1.3.6.1.4.1.207.8.4.4.3.27.2.1.6 | ColumnatFiberMonAlarmAction | read-write | current | Actions to take when an alarm occurs. Acceptable values are: 1. Log a message only. 2. Send snmp trap and log. 3. Shut down the interface and log. 4. Send trap… |
| 1.3.6.1.4.1.207.8.4.4.3.27.3 | TableatFiberMonStateTable | not-accessible | current | This table contains the information of fiber monitoring state for SFPs. |
| 1.3.6.1.4.1.207.8.4.4.3.27.3.1 | RowatFiberMonStateEntry | not-accessible | current | Entry for fiber monitoring state table. It contains state values for a fiber channel. |
| 1.3.6.1.4.1.207.8.4.4.3.27.3.1.1 | ColumnatFiberMonIfindex | read-only | current | The index of the interface where the pluggable is in. |
| 1.3.6.1.4.1.207.8.4.4.3.27.3.1.2 | ColumnatFiberMonChannel | read-only | current | The channel number of the pluggable. |
| 1.3.6.1.4.1.207.8.4.4.3.27.3.1.3 | ColumnatFiberMonlIfDescription | read-only | current | Interface description. Normally it would be the name of the interface. |
| 1.3.6.1.4.1.207.8.4.4.3.27.3.1.4 | ColumnatFiberMonActualBaseline | read-only | current | The calculated baseline value for the link, in units of 0.0001mW. |
| 1.3.6.1.4.1.207.8.4.4.3.27.3.1.5 | ColumnatFiberMonThreshold | read-only | current | Threshold value for alarm to occur, in units of 0.0001mW. |
| 1.3.6.1.4.1.207.8.4.4.3.27.3.1.6 | ColumnatFiberMonReadingHistory | read-only | current | The reading history. It is a string containing last 12 readings. |
| 1.3.6.1.4.1.207.8.4.4.3.27.3.1.7 | ColumnatFiberMonMinReading | read-only | current | The minimum reading of rx power, in units of 0.0001mW. |
| 1.3.6.1.4.1.207.8.4.4.3.27.3.1.8 | ColumnatFiberMonMaxReading | read-only | current | The maximum reading of rx power, in units of 0.0001mW. |
| 1.3.6.1.4.1.207.8.4.4.3.27.3.1.9 | ColumnatFiberMonLastReading | read-only | current | The most recent reading of rx power, in units of 0.0001mW. -1 is returned if no readings have been taken yet. |