MIB Viewer

AT-PLUGGABLE-DIAGNOSTICS-MIB

62 objects
The AT Pluggbale Diagnostics MIB contains objects to retrieve the standard diagnostic information from installed SFP modules.
OIDNameAccessStatusDescription
1.3.6.1.4.1.207.8.4.4.3.28IdentityatPluggableDiagThe AT Pluggbale Diagnostics MIB contains objects to retrieve the standard diagnostic information from installed SFP modules.
1.3.6.1.4.1.207.8.4.4.3.28.1NodeatPluggableDiagTable
1.3.6.1.4.1.207.8.4.4.3.28.1.1TableatPluggableDiagTempTablenot-accessiblecurrentA table of information regarding the various temperature parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables instal…
1.3.6.1.4.1.207.8.4.4.3.28.1.1.1RowatPluggableDiagTempEntrynot-accessiblecurrentThe information about various temperature parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, curr…
1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.1ColumnatPluggableDiagTempIfIndexnot-accessiblecurrentThe ifindex of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.2ColumnatPluggableDiagTempChannelnot-accessiblecurrentThe channel number of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.3ColumnatPluggableDiagTempStatusReadingread-onlycurrentThe current temperature status reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.4ColumnatPluggableDiagTempCurrentAlarmread-onlycurrentThe current temperature alarm reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.5ColumnatPluggableDiagTempAlarmMaxread-onlycurrentThe maximum temperature alarm threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.6ColumnatPluggableDiagTempAlarmMinread-onlycurrentThe minimum temperature alarm threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.7ColumnatPluggableDiagTempCurrentWarningread-onlycurrentThe current temperature warnings.
1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.8ColumnatPluggableDiagTempWarningMaxread-onlycurrentThe maximum temperature warning threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.9ColumnatPluggableDiagTempWarningMinread-onlycurrentThe minimum temperature warning threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.2TableatPluggableDiagVccTablenot-accessiblecurrentA table of information regarding the various Voltage (Vcc) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables inst…
1.3.6.1.4.1.207.8.4.4.3.28.1.2.1RowatPluggableDiagVccEntrynot-accessiblecurrentThe information about various Voltage (Vcc) parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, cu…
1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.1ColumnatPluggableDiagVccIfIndexnot-accessiblecurrentThe ifindex of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.2ColumnatPluggableDiagVccChannelnot-accessiblecurrentThe channel number of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.3ColumnatPluggableDiagVccStatusReadingread-onlycurrentThe current Voltage (Vcc) status reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.4ColumnatPluggableDiagVccCurrentAlarmread-onlycurrentThe current Voltage (Vcc) alarm reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.5ColumnatPluggableDiagVccAlarmMaxread-onlycurrentThe maximum Voltage (Vcc) alarm threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.6ColumnatPluggableDiagVccAlarmMinread-onlycurrentThe minimum Voltage (Vcc) alarm threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.7ColumnatPluggableDiagVccCurrentWarningread-onlycurrentThe current Voltage (Vcc) warnings.
1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.8ColumnatPluggableDiagVccWarningMaxread-onlycurrentThe maximum Voltage (Vcc) warning threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.9ColumnatPluggableDiagVccWarningMinread-onlycurrentThe minimum Voltage (Vcc) warning threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.3TableatPluggableDiagTxBiasTablenot-accessiblecurrentA table of information regarding the various Tx Bias Current (mA) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggabl…
1.3.6.1.4.1.207.8.4.4.3.28.1.3.1RowatPluggableDiagTxBiasEntrynot-accessiblecurrentThe information about various Tx Bias Current (mA) parameters of pluggables such as current status reading, current alarm status, higher and lower alarm thresh…
1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.1ColumnatPluggableDiagTxBiasIfIndexnot-accessiblecurrentThe ifindex of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.2ColumnatPluggableDiagTxBiasChannelnot-accessiblecurrentThe channel number of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.3ColumnatPluggableDiagTxBiasStatusReadingread-onlycurrentThe current Tx Bias (mA) status reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.4ColumnatPluggableDiagTxBiasCurrentAlarmread-onlycurrentThe current Tx Bias (mA) alarm reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.5ColumnatPluggableDiagTxBiasAlarmMaxread-onlycurrentThe maximum Tx Bias (mA) alarm threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.6ColumnatPluggableDiagTxBiasAlarmMinread-onlycurrentThe minimum Tx Bias (mA) alarm threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.7ColumnatPluggableDiagTxBiasCurrentWarningread-onlycurrentThe current Tx Bias (mA) warnings.
1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.8ColumnatPluggableDiagTxBiasWarningMaxread-onlycurrentThe maximum Tx Bias (mA) warning threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.9ColumnatPluggableDiagTxBiasWarningMinread-onlycurrentThe minimum Tx Bias (mA) warning threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.4TableatPluggableDiagTxPowerTablenot-accessiblecurrentA table of information regarding the various Tx Power (mW) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables inst…
1.3.6.1.4.1.207.8.4.4.3.28.1.4.1RowatPluggableDiagTxPowerEntrynot-accessiblecurrentThe information about various Tx Power (mW) parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, cu…
1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.1ColumnatPluggableDiagTxPowerIfIndexnot-accessiblecurrentThe ifindex of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.2ColumnatPluggableDiagTxPowerChannelnot-accessiblecurrentThe channel number of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.3ColumnatPluggableDiagTxPowerStatusReadingread-onlycurrentThe current Tx Power (mW) status reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.4ColumnatPluggableDiagTxPowerCurrentAlarmread-onlycurrentThe current Tx Power (mW) alarm reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.5ColumnatPluggableDiagTxPowerAlarmMaxread-onlycurrentThe maximum Tx Power (mW) alarm threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.6ColumnatPluggableDiagTxPowerAlarmMinread-onlycurrentThe minimum Tx Power (mW) alarm threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.7ColumnatPluggableDiagTxPowerCurrentWarningread-onlycurrentThe current Tx Power (mW) warnings.
1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.8ColumnatPluggableDiagTxPowerWarningMaxread-onlycurrentThe maximum Tx Power (mW) warning threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.9ColumnatPluggableDiagTxPowerWarningMinread-onlycurrentThe minimum Tx Power (mW) warning threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.5TableatPluggableDiagRxPowerTablenot-accessiblecurrentA table of information regarding the various Rx Power (mW) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables inst…
1.3.6.1.4.1.207.8.4.4.3.28.1.5.1RowatPluggableDiagRxPowerEntrynot-accessiblecurrentThe information about various Rx Power (mW) parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, cu…
1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.1ColumnatPluggableDiagRxPowerIfIndexnot-accessiblecurrentThe ifindex of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.2ColumnatPluggableDiagRxPowerChannelnot-accessiblecurrentThe channel number of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.3ColumnatPluggableDiagRxPowerStatusReadingread-onlycurrentThe current Rx Power (mW) status reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.4ColumnatPluggableDiagRxPowerCurrentAlarmread-onlycurrentThe current Rx Power (mW) alarm reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.5ColumnatPluggableDiagRxPowerAlarmMaxread-onlycurrentThe maximum Rx Power (mW) alarm threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.6ColumnatPluggableDiagRxPowerAlarmMinread-onlycurrentThe minimum Rx Power (mW) alarm threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.7ColumnatPluggableDiagRxPowerCurrentWarningread-onlycurrentThe current Rx Power (mW) warnings.
1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.8ColumnatPluggableDiagRxPowerWarningMaxread-onlycurrentThe maximum Rx Power (mW) warning threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.9ColumnatPluggableDiagRxPowerWarningMinread-onlycurrentThe minimum Rx Power (mW) warning threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.6TableatPluggableDiagRxLosTablenot-accessiblecurrentA table of information regarding the Rx Loss of Singal (Los) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables in…
1.3.6.1.4.1.207.8.4.4.3.28.1.6.1RowatPluggableDiagRxLosEntrynot-accessiblecurrentThe information about various Rx Loss of Singal (Los) parameters of pluggables such as current status reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.6.1.1ColumnatPluggableDiagRxLosIfIndexnot-accessiblecurrentThe ifindex of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.6.1.2ColumnatPluggableDiagRxLosChannelnot-accessiblecurrentThe channel number of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.6.1.3ColumnatPluggableDiagRxLosStatusReadingread-onlycurrentThe current Rx Los status reading.