MIB Viewer

BRCM-BATTERY-MGMT-MIB

69 objects
Broadcom proprietary MIB for runtime management of objects related to battery powered devices.
Imported Objects
BRCM-CABLEDATA-MGMT-MIBcableDataMgmtMIBObjects
SNMPv2-SMIInteger32 MODULE-IDENTITY OBJECT-IDENTITY OBJECT-TYPE Unsigned32
SNMPv2-TCDateAndTime DisplayString TEXTUAL-CONVENTION TruthValue
UPS-MIBPositiveInteger
OIDNameAccessStatusDescription
1.3.6.1.4.1.4413.2.2.2.1.10IdentitybatteryMgmtBroadcom proprietary MIB for runtime management of objects related to battery powered devices.
1.3.6.1.4.1.4413.2.2.2.1.10.1NodebatteryMgmtBase
1.3.6.1.4.1.4413.2.2.2.1.10.1.1TablebatteryTablenot-accessiblecurrentA table of batteries present on the system.
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1RowbatteryEntrynot-accessiblecurrentAn entry describing the characteristics of an individual battery.
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.1ColumnbattIndexnot-accessiblecurrentIdentifies the instance number of this individual battery.
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.2ColumnbattCapacityread-onlycurrentThe charge capacity of this battery.
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.3ColumnbattMaximumVoltageread-onlycurrentThe voltage at which this battery is considered to be fully charged. Note that if battChargerMaximumCharge is set to less than 100%, the battery will never be …
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.4ColumnbattMinimumVoltageread-onlycurrentThe voltage at which this battery is considered to be fully discharged.
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.5ColumnbattMeasuredVoltageread-onlycurrentThe most recently measured voltage of this battery.
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.6ColumnbattIsValidread-onlycurrentIndicates whether this battery is considered valid by the battery charger. A value of false(2) here indicates some kind of failure with this battery.
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.7ColumnbattIsSelectedread-onlycurrentIndicates whether this battery is currently selected for charging or discharging.
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.8ColumnbattEstimatedMinutesRemainingread-onlycurrentAn estimate of the time to depletion of this battery's charge under the present load conditions if the utility power is off and remains off, or if it were to b…
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.9ColumnbattEstimatedChargeRemainingread-onlycurrentAn estimate of this battery's charge remaining expressed as a percent of full charge.
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.10ColumnbattErrorsread-onlycurrentIndicates the number of errors reported by the charger when trying to charge this battery. This object should always have a value of zero if all is well with t…
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.11ColumnbattEpromRevisionread-onlycurrentThe version of the battery EPROM.
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.12ColumnbattPackSupplierread-onlycurrentBattery Pack Supplier
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.13ColumnbattModelNumberread-onlycurrentBattery Model Number.
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.14ColumnbattSerialNumberread-onlycurrentBattery Serial Number.
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.15ColumnbattCellSupplierread-onlycurrentBattery Cell Supplier.
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.16ColumnbattCellCapacityread-onlycurrentBattery Cell Capacity.
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.17ColumnbattCellDateCoderead-onlycurrentBattery Cell Date Code(mmddyy).
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.18ColumnbattPackDateCoderead-onlycurrentBattery Pack Date Code(mmddyy).
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.19ColumnbattTemperatureread-onlycurrentThe temperature as reported by this battery. If the battery pack does not support temperature measurement then this object will not be supported.
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.20ColumnbattPackGUIDread-onlycurrentThe battery pack globally unique ID (0x<cc><iiiiiiii><ff>). Where <cc> is an 8-bit CRC, <iiiiiiii> is the 48-bit ID, and <ff> is the 8-bit family code. If the …
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.21ColumnbattActualCapacityread-onlycurrentThe current maximum charge capacity of this battery. If the hardware does not support periodic life testing, this will return the same value as battDesignCapac…
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.22ColumnbattAgeread-onlycurrentSpecifies the current age of the battery as a percentage of its design capacity. This value could be calculated by dividing battActualCapacity by battDesignCap…
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.23ColumnbattNextLifeTestread-writecurrentReturns/specifies the date and time of the next life test (mmddyyyy hh:mm:ss) for the specified pack. If the charger does not support periodic life testing the…
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.24ColumnbattDischargeTableread-onlycurrentReturns the full discharge table for the specified battery as a comma-delimited string
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.25ColumnbattCompressedDischargeTableread-onlycurrentReturns the compressed discharge table from the specified battery
1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.26ColumnbattInvalidateNonVolSlotread-writecurrentInvalidates the specified non-vol slot
1.3.6.1.4.1.4413.2.2.2.1.10.2NodebatteryCharger
1.3.6.1.4.1.4413.2.2.2.1.10.2.1ScalarbattChargerMicrocodeVersionread-onlycurrentThe version of the battery charger microcode.
1.3.6.1.4.1.4413.2.2.2.1.10.2.2ScalarbattChargerMicrocodeBuildTimeread-onlycurrentThe build date and time of the battery charger microcode.
1.3.6.1.4.1.4413.2.2.2.1.10.2.3ScalarbattChargerInputVoltageread-onlycurrentThe most recently measured input voltage to the battery charger. Typically, if operating on battery power, this value will approach zero. If operating on utili…
1.3.6.1.4.1.4413.2.2.2.1.10.2.4ScalarbattChargerStateread-onlycurrentThe current state of the battery charger. Note that all states may not be supported on all types of chargers.
1.3.6.1.4.1.4413.2.2.2.1.10.2.5ScalarbattChargerMaximumChargeread-onlycurrentReports the level to which the charger will charge the batteries.
1.3.6.1.4.1.4413.2.2.2.1.10.2.6ScalarbattChargerReplaceBatteryThresholdread-writecurrentSpecifies the minimum charge percentage that the battery must be able to reach when charging. If a battery cannot be charged above this percentage, it will be …
1.3.6.1.4.1.4413.2.2.2.1.10.2.7ScalarbattChargerLowChargeThresholdread-writecurrentSpecifies the charge percentage at which the bcmAlarmLowBatteryCharge will be raised.
1.3.6.1.4.1.4413.2.2.2.1.10.2.8ScalarbattChargerHardwareFaultsAllowedread-writecurrentSpecifies the hardware faults that are currently allowed to affect the battery subsystem. If the charger does not support hardware faults then this object will…
1.3.6.1.4.1.4413.2.2.2.1.10.2.9ScalarbattChargerHardwareFaultsDetectedread-writecurrentSpecifies the hardware faults that are currently active in the battery subsystem. Writing any valoe to this entry caues ALL faults to be reset. See bcmAlarmHar…
1.3.6.1.4.1.4413.2.2.2.1.10.2.10ScalarbattChargerLifeTestIntervalread-writecurrentSpecifies the number of days between periodic life tests (default = 180). If the charger does not support periodic life testing then this object will not be su…
1.3.6.1.4.1.4413.2.2.2.1.10.2.11ScalarbattChargerLifeTestEnableread-writecurrentSpecifies whether or not periodic life testing is enabled. If the charger does not support periodic life testing then this object will not be supported. Defaul…
1.3.6.1.4.1.4413.2.2.2.1.10.2.12ScalarbattChargerLifeTestTODread-writecurrentSpecifies the time of day (hh:mm) using a 24-hour clock at which battery life testing will be scheduled. If the charger does not support periodic life testing …
1.3.6.1.4.1.4413.2.2.2.1.10.2.13ScalarbattChargerLifeTestStatusread-onlycurrentReturns the current life test state
1.3.6.1.4.1.4413.2.2.2.1.10.2.14ScalarbattChargerAbortLifeTestread-writecurrentSetting this to TRUE aborts an in-progress life test. Reads always return FALSE. No effect if a life test is not currently in progress. If the charger does not…
1.3.6.1.4.1.4413.2.2.2.1.10.3NodebatteryPowerMgmt
1.3.6.1.4.1.4413.2.2.2.1.10.3.1NodebatteryPowerMgmtInterfaces
1.3.6.1.4.1.4413.2.2.2.1.10.3.1.1ScalarbattPowerMgmtCmDelayread-writecurrentSpecifies the number of seconds following transition to battery power before the DOCSIS CM interface will enter power management mode. If set to -1, the interf…
1.3.6.1.4.1.4413.2.2.2.1.10.3.1.2ScalarbattPowerMgmtEthernetDelayread-writecurrentSpecifies the number of seconds following transition to battery power before the ethernet interface will enter power management mode. If set to -1, the interfa…
1.3.6.1.4.1.4413.2.2.2.1.10.3.1.3ScalarbattPowerMgmtUsbDelayread-writecurrentSpecifies the number of seconds following transition to battery power before the USB interface will enter power management mode. If set to -1, the interface wi…
1.3.6.1.4.1.4413.2.2.2.1.10.3.1.4ScalarbattPowerMgmtWiFiDelayread-writecurrentSpecifies the number of seconds following transition to battery power before the WiFi interface will enter power management mode. If set to -1, the interface w…
1.3.6.1.4.1.4413.2.2.2.1.10.3.1.5ScalarbattPowerMgmtBluetoothDelayread-writecurrentSpecifies the number of seconds following transition to battery power before the bluetooth interface will enter power management mode. If set to -1, the interf…
1.3.6.1.4.1.4413.2.2.2.1.10.3.1.6ScalarbattPowerMgmtHpnaDelayread-writecurrentSpecifies the number of seconds following transition to battery power before the HPNA interface will enter power management mode. If set to -1, the interface w…
1.3.6.1.4.1.4413.2.2.2.1.10.4NodebatteryBcmAlarms
1.3.6.1.4.1.4413.2.2.2.1.10.4.1IdentitybcmAlarmLowBatteryChargecurrentThe value of upsEstimatedChargeRemaining is less than or equal to the value of battChargerLowChargeThreshold.
1.3.6.1.4.1.4413.2.2.2.1.10.4.2IdentitybcmAlarmTempBadChargeSuspendedcurrentThe temperature of the device has exceeded operational limits for safe battery charging, and battery charging has been suspended.
1.3.6.1.4.1.4413.2.2.2.1.10.4.3IdentitybcmAlarmTempBadPowerReducedcurrentThe temperature of the device has exceeded operational limits, and the device has been placed in low power mode in an to attempt to reduce heat production.
1.3.6.1.4.1.4413.2.2.2.1.10.4.4IdentitybcmAlarmBatteryMissingcurrentThere are no batteries installed in the device and the device will not be capable of sustaining power in the event of utility power loss.
1.3.6.1.4.1.4413.2.2.2.1.10.4.5IdentitybcmAlarmTempBadDischargeInhibitedcurrentThe temperature of the device has exceeded operational limits for safe battery discharging, and battery discharging has been inhibited.
1.3.6.1.4.1.4413.2.2.2.1.10.4.6IdentitybcmAlarmHardwareFaultcurrentIndicates that a hardware fault that is enabled in battChargerHardwareFaultsAllowed has been detected in battChargerHardwareFaultsDetected (i.e. the logical AN…
1.3.6.1.4.1.4413.2.2.2.1.10.4.7IdentitybcmAlarmLowPowercurrentIndicates that the system has been placed into low power mode in order to extend battery life.
1.3.6.1.4.1.4413.2.2.2.1.10.5NodebatteryThermalMgmt
1.3.6.1.4.1.4413.2.2.2.1.10.5.1TablebatteryThermalSensorTablenot-accessiblecurrentA table of thermal sensors present on the system.
1.3.6.1.4.1.4413.2.2.2.1.10.5.1.1RowbatteryThermalSensorEntrynot-accessiblecurrentAn entry describing a single thermal sensor.
1.3.6.1.4.1.4413.2.2.2.1.10.5.1.1.1ColumnbattThermalSensorTypenot-accessiblecurrentIdentifies the type of this thermal sensor.
1.3.6.1.4.1.4413.2.2.2.1.10.5.1.1.2ColumnbattThermalSensorIndexnot-accessiblecurrentIdentifies the instance number of this thermal sensor.
1.3.6.1.4.1.4413.2.2.2.1.10.5.1.1.3ColumnbattThermalSensorDescriptionread-onlycurrentA textual description of this thermal sensor.
1.3.6.1.4.1.4413.2.2.2.1.10.5.1.1.4ColumnbattThermalSensorTemperatureread-onlycurrentThe temperature as reported by this thermal sensor.
Type Definitions
NameSyntaxStatusDescription
HardwareFaultBITS { chargerOverVoltageFault(0), chargerOverCurrentFault(1), chargerPrequalVoltageFault(3), chargerDischargeOverCurrentFault(4), chargerGeneralDischargeFault(5), chargerInputOverVoltageFault(8), chargerUnexpectedBatteryVoltage(9), chargerUnexpectedBatteryCurrent(10), chargerBatteryOverVoltage(11), chargerBatteryEnablesShorted(12) }currentThis data type represents a bit-mask of potential hardware fault conditions in the battChargerHardwareFaultsAllowed and battChargerHardwareFaultsDetected entries.