MIB Viewer

BRCM-CM-ENGINEERING-MIB

83 objects
Broadcom cabledata private MIB
OIDNameAccessStatusDescription
1.3.6.1.4.1.4413.2.99.1.1.3.2IdentitycablemodemEngineeringBroadcom cabledata private MIB
1.3.6.1.4.1.4413.2.99.1.1.3.2.1NodecmEngrBase
1.3.6.1.4.1.4413.2.99.1.1.3.2.1.1ScalarcmEngr33xxOpcoderead-writecurrentThe hardware address or multibyte opcode to access in a 33xx family device when executing a cmEngr33xxCommand operation.
1.3.6.1.4.1.4413.2.99.1.1.3.2.1.2ScalarcmEngr33xxDataread-writecurrentThe data read from or to be written to a 33xx family device when executing a cmEngr33xxCommand operation.
1.3.6.1.4.1.4413.2.99.1.1.3.2.1.3ScalarcmEngr33xxCommandread-writecurrentSetting this value to read(0) will cause a read operation to be executed on the multibyte opcode specified in cmEngr33xxOpcode. The data read back from the ope…
1.3.6.1.4.1.4413.2.99.1.1.3.2.2NodecmEngrDownstreamCalibration
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.1ScalarcmDsCalZeroTunerCoefsread-writecurrentSetting this object to true(1) will result in all writable objects in the cmDsCalTunerCoefTable being set to zero. Sets to false(2) will be accepted, but will …
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.2ScalarcmDsCalNumTunerCoefsread-writecurrentControls and reflects the number of tuner coefficients per downstream frequency in the cmDsCalTunerCoefTable. Note that the total number of entries in this tab…
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3TablecmDsCalTunerCoefTablenot-accessiblecurrentA list of tuner coeffiencents to be used when calculating downstream power for this device.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3.1RowcmDsCalTunerCoefEntrynot-accessiblecurrentAn entry defining a tuner coefficient for a given frequency at the given index for this device.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3.1.1ColumncmDsCalTunerCoefIndexnot-accessiblecurrentIdentifies the instance of this tuner coefficient.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3.1.2ColumncmDsCalTunerCoefFrequencyread-onlycurrentThe downstream frequency at which this instance of cmDsCalTunerCoefValue applies. This read-only object is provided here for convenience. Value is identical to…
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3.1.3ColumncmDsCalTunerCoefValueread-writecurrentThe value of this tuner coefficient multiplied by one million. For example, a tuner coefficient value of 0.218369 would be represented as 218369. This gives a …
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3.1.4ColumncmDsCalTunerCoefCopyFromread-writecurrentSetting this object to the value of the first element of an index of a row in this table will cause all coefficients for this frequency to be copied from the c…
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.4ScalarcmDsCalZeroIFCoefsread-writecurrentSetting this object to true(1) will result in all writable objects in the cmDsCalIFCoefTable being set to zero. Sets to false(2) will be accepted, but will not…
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.5ScalarcmDsCalNumIFCoefsread-writecurrentControls and reflects the number of IF coefficients per downstream frequency in the cmDsCalIFCoefTable. Note that the total number of entries in this table wil…
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.6TablecmDsCalIFCoefTablenot-accessiblecurrentA list of intermediate frequency coeffiencents to be used when calculating downstream power for this device.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.6.1RowcmDsCalIFCoefEntrynot-accessiblecurrentAn entry defining an IF coefficient for a given frequency at the given index for this device.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.6.1.1ColumncmDsCalIFCoefIndexnot-accessiblecurrentIdentifies the instance of this IF coefficient.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.6.1.2ColumncmDsCalIFCoefFrequencyread-onlycurrentThe downstream frequency at which this instance of cmDsCalIFCoefValue applies. This read-only object is provided here for convenience. Value is identical to th…
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.6.1.3ColumncmDsCalIFCoefValueread-writecurrentThe value of this IF coefficient multiplied by one hundred thousand. For example, an IF coefficent value of -2662.94 would be represented as -266294000. This g…
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.6.1.4ColumncmDsCalIFCoefCopyFromread-writecurrentSetting this object to the value of the first element of an index of a row in this table will cause all coefficients for this frequency to be copied from the c…
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.7ScalarcmDsCalZeroFineCoefsread-writecurrentSetting this object to true(1) will result in all writable objects in the cmDsCalFineCoefTable being set to zero. Sets to false(2) will be accepted, but will n…
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.8ScalarcmDsCalNumFineCoefsread-writecurrentControls and reflects the number of Fine coefficients per downstream frequency in the cmDsCalFineCoefTable. Note that the total number of entries in this table…
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.9TablecmDsCalFineCoefTablenot-accessiblecurrentA list of Fine coeffiencents to be used when calculating downstream power for this device.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.9.1RowcmDsCalFineCoefEntrynot-accessiblecurrentAn entry defining a Fine coefficient for a given frequency at the given index for this device.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.9.1.1ColumncmDsCalFineCoefIndexnot-accessiblecurrentIdentifies the instance of this Fine coefficient.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.9.1.2ColumncmDsCalFineCoefFrequencyread-onlycurrentThe downstream frequency at which this instance of cmDsCalFineCoefValue applies. This read-only object is provided here for convenience. Value is identical to …
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.9.1.3ColumncmDsCalFineCoefValueread-writecurrentThe value of this fine coefficient multiplied by one million. For example, a fine coefficent value of 36.5494 would be represented as 36549400. This gives an e…
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.9.1.4ColumncmDsCalFineCoefCopyFromread-writecurrentSetting this object to the value of the first element of an index of a row in this table will cause all coefficients for this frequency to be copied from the c…
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.10ScalarcmDsCalZeroEqCoefsread-writecurrentSetting this object to true(1) will result in all writable objects in the cmDsCalEqualizerCoefTable being set to zero. Sets to false(2) will be accepted, but w…
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.11ScalarcmDsCalNumEqCoefsread-writecurrentControls and reflects the number of equalizer coefficients per downstream frequency in the cmDsCalEqualizerCoefTable. Note that the total number of entries in …
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.12TablecmDsCalEqCoefTablenot-accessiblecurrentA list of equalizer coeffiencents to be used when calculating downstream power for this device.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.12.1RowcmDsCalEqCoefEntrynot-accessiblecurrentAn entry defining a equalizer coefficient for a given frequency at the given index for this device.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.12.1.1ColumncmDsCalEqCoefIndexnot-accessiblecurrentIdentifies the instance of this equalizer coefficient.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.12.1.2ColumncmDsCalEqCoefFrequencyread-onlycurrentThe downstream frequency at which this instance of cmDsCalEqCoefValue applies. This read-only object is provided here for convenience. Value is identical to th…
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.12.1.3ColumncmDsCalEqCoefValueread-writecurrentThe value of this equalizer coefficient multiplied by one hundred thousand. For example, an equalizer coefficent value of 4287.95 would be represented as 42879…
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.12.1.4ColumncmDsCalEqCoefCopyFromread-writecurrentSetting this object to the value of the first element of an index of a row in this table will cause all coefficients for this frequency to be copied from the c…
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.13ScalarcmDsCalNumLDAIxReadsread-writecurrentSets the number of times the LDAIx registers will be read before doing the power calculations. It will average the register values.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.14ScalarcmDsCalLDAIxReadIntervalread-writecurrentSets the time (in milliseconds) between each read of the LDAIx registers.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.15ScalarcmDsCalTunerStepread-writecurrentSets the step size (in dBmV) that was used when sampling the tuner table. This influences how the data is interpolated when calculating the tuner gain part of …
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.16ScalarcmDsCalMasterPowerOffsetread-writecurrentSets the master offset power value (in dBmV) for the modem. Each frequency band in the table has an offset power adjustment that is applied to this value when …
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.17ScalarcmDsCalCharacterizeNowread-writecurrentWhen set to true(1), the CM will execute its DS characterization routine using the frequency specified by cmDsCalFrequency, and the modulation type specified b…
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.18ScalarcmDsCalNormalLDAITread-onlycurrentShows the contents of the LDAIT register after executing the 'normal' portion of the CM DS characterization routine.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.19ScalarcmDsCalNormalLDAIFread-onlycurrentShows the contents of the LDAIF register after executing the 'normal' portion of the CM DS characterization routine.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.20ScalarcmDsCalNormalLDAIIread-onlycurrentShows the contents of the LDAII register after executing the 'normal' portion of the CM DS characterization routine.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.21ScalarcmDsCalFrozenLDAITread-onlycurrentShows the contents of the LDAIT register after executing the 'frozen' portion of the CM DS characterization routine.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.22ScalarcmDsCalFrozenLDAIFread-onlycurrentShows the contents of the LDAIF register after executing the 'frozen' portion of the CM DS characterization routine.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.23ScalarcmDsCalFrozenLDAIIread-onlycurrentShows the contents of the LDAII register after executing the 'frozen' portion of the CM DS characterization routine.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.24ScalarcmDsCalFGainTapread-onlycurrentShows the value of the equalizer main tap after executing the F-Gain portion of the CM DS characterization routine.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.25ScalarcmDsCalTGainTapread-onlycurrentShows the value of the equalizer main tap after executing the T-Gain portion of the CM DS characterization routine.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.26ScalarcmDsCalIGainTapread-onlycurrentShows the value of the equalizer main tap after executing the I-Gain portion of the CM DS characterization routine.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.27ScalarcmDsCalFrequencyErrorread-onlycurrentReports the amount of frequency error in the downstream signal.
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.28ScalarcmDsCalTunerCoefTablePopulateread-writecurrentWhen set to true(1), the downstream tuner coefficient data will be loaded into the cmDsCalTunerCoefTable. If the table is already populated, it will be flushed…
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.29ScalarcmDsCalIFCoefTablePopulateread-writecurrentWhen set to true(1), the downstream intermediate frequency coefficient data will be loaded into the cmDsCalIFCoefTable. If the table is already populated, it w…
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.30ScalarcmDsCalFineCoefTablePopulateread-writecurrentWhen set to true(1), the downstream fine coefficient data will be loaded into the cmDsCalFineCoefTable. If the table is already populated, it will be flushed a…
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.31ScalarcmDsCalEqCoefTablePopulateread-writecurrentWhen set to true(1), the downstream equalizer coefficient data will be loaded into the cmDsCalEqCoefTable. If the table is already populated, it will be flushe…
1.3.6.1.4.1.4413.2.99.1.1.3.2.3NodecmEngrUpstreamCalibration
1.3.6.1.4.1.4413.2.99.1.1.3.2.3.1ScalarcmUsCalControlStartPowerread-writecurrentControls and reflects the starting power used in the cmUsCalControlTable. Changing this value will result in the size of the cmUsCalControlTable being altered.
1.3.6.1.4.1.4413.2.99.1.1.3.2.3.2ScalarcmUsCalControlEndPowerread-writecurrentControls and reflects the ending power used in the cmUsCalControlTable. Changing this value will result in the size of the cmUsCalControlTable being altered.
1.3.6.1.4.1.4413.2.99.1.1.3.2.3.3ScalarcmUsCalControlResolutionread-writecurrentControls and reflects the resolution used in the cmUsCalControlTable. Changing this value will result in the size of the cmUsCalControlTable being altered.
1.3.6.1.4.1.4413.2.99.1.1.3.2.3.4ScalarcmUsCalZeroControlread-writecurrentIf set to true(1), all instances of cmUsCalControlAmpGain and cmUsCalControlDacAtten in the cmUsCalControlTable will be set to a value of zero. When read, alwa…
1.3.6.1.4.1.4413.2.99.1.1.3.2.3.5TablecmUsCalControlTablenot-accessiblecurrentA list of control values to be used when calculating upstream power for this device.
1.3.6.1.4.1.4413.2.99.1.1.3.2.3.5.1RowcmUsCalControlEntrynot-accessiblecurrentAn entry defining the control values for a given power at the given index for this device.
1.3.6.1.4.1.4413.2.99.1.1.3.2.3.5.1.1ColumncmUsCalControlIndexnot-accessiblecurrentIdentifies the instance of this pair of control values.
1.3.6.1.4.1.4413.2.99.1.1.3.2.3.5.1.2ColumncmUsCalControlPowerread-onlycurrentIndicates the upstream power level which is expected when the amp gain and DAC attenuation are programmed as indicated in this entry. This value is read-only, …
1.3.6.1.4.1.4413.2.99.1.1.3.2.3.5.1.3ColumncmUsCalControlAmpGainread-writecurrentControls and reflects the amplifier gain setting used to produce an output power equal to the value of this entry's instance of cmUsCalControlPower.
1.3.6.1.4.1.4413.2.99.1.1.3.2.3.5.1.4ColumncmUsCalControlDacAttenread-writecurrentControls and reflects the DAC attenuation setting used to produce an output power equal to the value of this entry's instance of cmUsCalControlPower.
1.3.6.1.4.1.4413.2.99.1.1.3.2.3.6ScalarcmUsCalOffsetStartFreqread-writecurrentControls and reflects the starting frequency used in the cmUsCalOffsetTable. Changing this value will result in the size of the cmUsCalOffsetTable being altere…
1.3.6.1.4.1.4413.2.99.1.1.3.2.3.7ScalarcmUsCalOffsetEndFreqread-writecurrentControls and reflects the ending frequency used in the cmUsCalOffsetTable. Changing this value will result in the size of the cmUsCalOffsetTable being altered.
1.3.6.1.4.1.4413.2.99.1.1.3.2.3.8ScalarcmUsCalOffsetResolutionread-writecurrentControls and reflects the resolution used in the cmUsCalOffsetTable. Changing this value will result in the size of the cmUsCalControlTable being altered.
1.3.6.1.4.1.4413.2.99.1.1.3.2.3.9ScalarcmUsCalBoardTyperead-writecurrentSets the board revision that the tables have been calibrated for; it helps the app warn the user about incorrect configurations (loading a table that has been …
1.3.6.1.4.1.4413.2.99.1.1.3.2.3.10ScalarcmUsCalAmpTyperead-writecurrentSets the upstream amp that the tables have been calibrated for; it helps the app warn the user about incorrect configurations. These values are the same as tho…
1.3.6.1.4.1.4413.2.99.1.1.3.2.3.11ScalarcmUsCalAmpGainread-writecurrentControls and reflects the current value of the amplifier gain, an 8 bit hardware value.
1.3.6.1.4.1.4413.2.99.1.1.3.2.3.12ScalarcmUsCalDacAttenread-writecurrentControls and reflects the current value of the DAC attenuator, an 8 bit hardware value.
1.3.6.1.4.1.4413.2.99.1.1.3.2.3.13ScalarcmUsCalTransmitNowread-writecurrentWhen set to cw(1), the device will begin transmitting upstream in CW mode using the specified amp gain and DAC attenuation values. When set to bits23(2), the d…
1.3.6.1.4.1.4413.2.99.1.1.3.2.3.14ScalarcmUsCalControlTablePopulateread-writecurrentWhen set to true(1), the upstream calibration control data will be loaded into the cmUsCalControlTable. If the table is already populated, it will be flushed a…
1.3.6.1.4.1.4413.2.99.1.1.3.2.4NodecmEngrHardware
1.3.6.1.4.1.4413.2.99.1.1.3.2.4.1ScalarcmHwDSAGIread-writecurrentIF AGC Control
1.3.6.1.4.1.4413.2.99.1.1.3.2.4.2ScalarcmHwDSAGTread-writecurrentRF (Tuner) AGC Control
1.3.6.1.4.1.4413.2.99.1.1.3.2.4.3ScalarcmHwSTPGA1read-writecurrentIF PGA Control
1.3.6.1.4.1.4413.2.99.1.1.3.2.4.4ScalarcmHwSTABWread-writecurrentAGC Bandwidth Control
1.3.6.1.4.1.4413.2.99.1.1.3.2.4.5ScalarcmHwSTABW2read-writecurrentAGC Bandwidth Control 2