MIB Viewer

C-PRODUCT-CBR-V35-MIB

14 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.2011.2.1.1.1.1.15.5NodecbrV35PortConfig
1.3.6.1.4.1.2011.2.1.1.1.1.15.5.1TablecbrV35PortConfTablenot-accessiblemandatoryThis object contains the CBR's V.35 specific port Configuration table. There is one cbrV35PortConfEntry associated for each provisioned CBR port interface with…
1.3.6.1.4.1.2011.2.1.1.1.1.15.5.1.1RowcbrV35PortConfEntrynot-accessiblemandatoryAn entry in the CBR specific port Configuration table.
1.3.6.1.4.1.2011.2.1.1.1.1.15.5.1.1.1ColumncbrV35PortConfCableTyperead-onlymandatoryThis object indicates the type of cable connected to the port. An error is returned if an access is attempted on a physical interface other than a V.35 port in…
1.3.6.1.4.1.2011.2.1.1.1.1.15.5.1.1.2ColumncbrV35PortConfScrClockSourceread-writemandatoryThis object indicates the SCR clock source. This is aplicable for both DCE & DTE cable types. If the cable type is 'none', a get request returns whatever the v…
1.3.6.1.4.1.2011.2.1.1.1.1.15.5.1.1.3ColumncbrV35PortConfTxClockPhaseread-writemandatoryThis object indicates the type of Transmit clock phase needed to correct the clock out of phase problem. This is aplicable ONLY when a 'dte' cable is connected…
1.3.6.1.4.1.2011.2.1.1.1.1.15.5.1.1.4ColumncbrV35PortConfRtsread-onlymandatoryThis object indicates RTS pin status. Default value is off (1).
1.3.6.1.4.1.2011.2.1.1.1.1.15.5.1.1.5ColumncbrV35PortConfCtsread-onlymandatoryThis object indicates CTS pin status. Default value is off (1).
1.3.6.1.4.1.2011.2.1.1.1.1.15.5.1.1.6ColumncbrV35PortConfDcdread-onlymandatoryThis object indicates DCD pin status. Default value is off (1).
1.3.6.1.4.1.2011.2.1.1.1.1.15.5.1.1.7ColumncbrV35PortConfDsrread-onlymandatoryThis object indicates DSR pin status. Default value is off (1).
1.3.6.1.4.1.2011.2.1.1.1.1.15.5.1.1.8ColumncbrV35PortConfSctClockSourceread-writemandatoryThis object indicates the type of SCT clock source. This is aplicable for both 'DCE' & 'DTE' cable types. If no cable is attached then it just reflects the val…
1.3.6.1.4.1.2011.2.1.1.1.1.15.5.1.1.9ColumncbrV35PortConfRxTimingSourceread-writemandatoryThis object indicates the Serial interface Recieive Timing Source. The default value is dce-transmit-clock.
1.3.6.1.4.1.2011.2.1.1.1.1.15.5.1.1.10ColumncbrV35PortConfCableIDread-onlymandatoryThis object indicates the type of physical interface.
1.3.6.1.4.1.2011.2.1.1.1.1.15.5.1.1.11ColumncbrV35PortConfLoopBackTyperead-writemandatoryThis object indicates the type of loopback configured for the specified T1/E1 port interface. Network-line (2) redirects incoming remote traffic back into the …