C-PRODUCT-TRAP-MIB
180 objects
No module-level DESCRIPTION found.
Imported Objects
| C-PRODUCT-BASE-MIB | CardType TimeAndDate |
| C-PRODUCT-GROUP-MIB | c-product fault |
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1213-MIB | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2011.2.1.1.1.1.1 | NodealarmLossOfSignal | Loss of signal alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.2 | NodealarmOutOfFrame | Out of frame alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.3 | NodealarmAlarmIndicationSignal | AIS alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.4 | NodealarmIdleSignal | Idle signal alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.5 | NodealarmFarEndRcvFailure | Far end receive failure alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.6 | NodealarmLossOfCellDelineation | Loss of cell delineation alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.6.5 | Nodealarm | |||
| 1.3.6.1.4.1.2011.2.1.1.1.1.6.5.1 | ScalaralarmSeverity | not-accessible | mandatory | Severity of an alarm. |
| 1.3.6.1.4.1.2011.2.1.1.1.1.6.5.2 | ScalaralarmCardType | not-accessible | mandatory | Card type of the card which caused an alarm. |
| 1.3.6.1.4.1.2011.2.1.1.1.1.6.5.3 | ScalaralarmCardNumber | not-accessible | mandatory | Slot number of the card which caused an alarm. |
| 1.3.6.1.4.1.2011.2.1.1.1.1.6.5.4 | ScalaralarmPortNumber | not-accessible | mandatory | Port number of the card which caused an alarm. |
| 1.3.6.1.4.1.2011.2.1.1.1.1.6.5.5 | ScalaralarmSetTime | not-accessible | mandatory | The time when an alarm was generated. |
| 1.3.6.1.4.1.2011.2.1.1.1.1.6.5.6 | ScalaralarmClearTime | not-accessible | mandatory | The time when an alarm was cleared. For active alarms, the value of this object contains all zero's. For cleared alarms, this object contains the time when the… |
| 1.3.6.1.4.1.2011.2.1.1.1.1.6.5.7 | ScalaralarmDescription | not-accessible | mandatory | A readable string which describes an alarm. |
| 1.3.6.1.4.1.2011.2.1.1.1.1.7 | NodealarmVirtualPathAis | Virtual Path AIS. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.8 | NodealarmVirtualChannelAis | Virtual Channel AIS. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.9 | NodealarmMissingUploadImage | Cannot find card image to upload. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.10 | NodealarmCardReconfigOk | Configuration data of a card is reloaded. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.11 | NodealarmUnknownDbCardType | An unknown card type is found in database. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.12 | NodealarmCardReconfigFailure | Cannot reload configuration data to a card. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.13 | NodealarmCardTypeMismatch | The card type of a card slot in database does not match the card type of the same card slot in the shelf. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.14 | NodealarmNewCardConfigOk | Configuration data for a new card is uploaded. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.15 | NodealarmCardConfigFailure | Cannot upload configuration data to a card. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.16 | NodealarmUnknownCardType | An unknown card type is detected in a card slot. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.17 | NodealarmCardRemoval | A card is removed from a card slot. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.18 | NodealarmCardDownloadFailure | Cannot download card image to a card. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.19 | NodealarmMissingLeftPowerSupply | Power Supply 1 absent. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.20 | NodealarmMissingRightPowerSupply | Power Supply 2 absent. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.21 | NodealarmLeftPowerSupplyFailure | Left power supply failed. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.22 | NodealarmRightPowerSupplyFailure | Right power supply failed. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.23 | NodealarmRelayPowerFuseFailure | Relay power fuse failed. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.24 | NodealarmCommunicationFailure | Communication through DPRAM failed. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.25 | NodealarmFan1Failure | Fan #1 failed. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.26 | NodealarmFan2Failure | Fan #2 failed. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.27 | NodealarmFan3Failure | Fan #3 failed. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.28 | NodealarmFan4Failure | Fan #4 failed. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.29 | NodealarmFeacLoopback | FEAC loopback alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.30 | NodealarmNetworkLineLoopback | Network line loopback alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.31 | NodealarmLocalCardLoopback | Local card loopback alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.32 | NodealarmNetworkCardLoopback | Network card loopback alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.33 | NodealarmCardNotInstalled | Card not installed. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.34 | NodealarmCardInitialized | Card initialized. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.35 | NodealarmCellbusParity | Cellbus parity alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.36 | NodealarmReceiveFifoOverflow | Receive FIFO overflow alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.37 | NodealarmTransmitFifoOverflow | Transmit FIFO overflow alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.38 | NodealarmLpCellbusCongestion | LP cellbus congested alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.39 | NodealarmMpCellbusCongestion | MP cellbus congested alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.40 | NodealarmHpCellbusCongestion | HP cellbus congested alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.42 | NodealarmLoginFailure | Terminal login attempts failed for three times. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.43 | NodealarmPromChecksumError | PROM checksum error alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.44 | NodealarmBank0SramFailure | Bank 0 SRAM failure alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.45 | NodealarmBank1SramFailure | Bank 1 SRAM failure alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.46 | NodealarmSarSramFailure | SAR SRAM failure alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.47 | NodealarmHdlcSramFailure | HDLC SRAM failure alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.48 | NodealarmMailboxSramFailure | Mailbox SRAM failure alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.49 | NodealarmCellbusXlnkPrgFailure | Cellbus Xilinx programming failure alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.50 | NodealarmPort01XlnkPrgFailure | Port 01 Xilinx programming failure alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.51 | NodealarmPort23XlnkPrgFailure | Port 23 Xilinx programming failure alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.52 | NodealarmPort45XlnkPrgFailure | Port 45 Xilinx programming failure alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.53 | NodealarmPort67XlnkPrgFailure | Port 67 Xilinx programming failure alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.54 | NodealarmSarXlnkPrgFailure | SAR Xilinx programming failure alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.55 | NodealarmPortInBandLpbkFailure | Port in-band loopback failure alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.56 | NodealarmE1Channel16Ais | E1 channel 16 AIS alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.57 | NodealarmE1LossOfMultiframeCas | E1 loss of multiframe CAS alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.58 | NodealarmE1FarEndLossOfCas | E1 far end loss of CAS alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.61 | NodealarmPortYellow | Port Yellow alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.64 | NodealarmVcRdiReceived | VC RDI Received. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.66 | NodealarmInternalRefClkFailure | Internal reference clock failure alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.67 | NodealarmBitsRefClkFailure | BITS reference clock failure alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.68 | NodealarmCbrRefClkFailure | CBR reference clock failure alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.69 | NodealarmDs3RefClkFailure | DS3 reference clock failure alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.70 | NodealarmLossOfClock | Loss of clock alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.71 | NodealarmRemoteLoopback | Remote loopback alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.73 | NodealarmOc3RefClkFailure | OC3 reference clock failure alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.74 | NodealarmE3RefClkFailure | E3 reference clock failure alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.75 | NodealarmSystemPowerUp | System power up. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.77 | NodealarmLossCellDelin | Loss of cell delineation. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.78 | NodealarmLossImaFrame | Loss of IMA frame. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.79 | NodealarmLossDiffSync | Loss of differential synchronization. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.80 | NodealarmDupImaId | Duplicate IMA ID. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.81 | NodealarmBadImaId | Bad IMA ID. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.82 | NodealarmBadM | Bad IMA M value. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.83 | NodealarmDupLinkId | Duplicate link ID. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.84 | NodealarmDupOff | Duplicate IMA offset. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.85 | NodealarmTestPatFailed | Test pattern failed. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.86 | NodealarmBadLinkId | Bad IMA Link ID. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.87 | NodealarmBadOffset | Bad IMA offset. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.88 | NodealarmBadScci | Bad SCCI. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.89 | NodealarmFeBadM | Far end config abort due to bad M value. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.90 | NodealarmBadSymmetry | Far end symmetry has changed. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.91 | NodealarmTxMscon | Near end and far end transmit link misconnect. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.92 | NodealarmImaFault | Near end IMA fault. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.93 | NodealarmFeTxUnusable | Transmit IMA is unusable due to far end. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.94 | NodealarmFeRxUnusable | Receive IMA is unusable due to far end. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.95 | NodealarmImaRFI | Remote failure indication. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.96 | NodealarmGroupNoLink | IMA group total link loss. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.97 | NodealarmGrMultiImaID | Group has multiple IMA ID values on links of same group. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.98 | NodealarmGrMultiM | IMA frame length mismatch on links of same group. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.99 | NodealarmGrMultiSymm | Symmetry mismatch on links of same group. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.100 | NodealarmIMARefClkFailure | DS1 UNI reference clock failure alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.101 | NodealarmFAMRefClkFailure | FAM reference clock failure alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.102 | NodealarmAlarmsCleared | Current alarms have been cleared by user. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.103 | NodealarmAlarmHistoryOverflow | History alarm information is being lost. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.104 | NodealarmAfaLinkRemoval | Link removed because of AFA conditions. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.105 | NodealarmLmiLinkDown | LMI has brought down link. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.106 | NodealarmExcessLinkDelay | Excessive link delay. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.107 | NodealarmGrDupImaID | Group has duplicate IMA ID. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.108 | NodealarmGroupDegradedSer | Group is running with degraded service. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.109 | NodealarmGroupNlessP | Group failed because there are not enough links. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.110 | NodealarmSarInitFailure | SAR failed during initialization. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.111 | NodealarmInBandLpbk | In-band loopback active. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.112 | NodealarmWrongSlotForCard | Wrong slot for card. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.113 | NodealarmCellBfSDRamFail | Cell Buffer SDRAM Failure. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.114 | NodealarmXilinxProgramFail | Xilinx Program Failure. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.115 | NodealarmHeartBeatFail | Heart Beat Failure. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.116 | NodealarmQcontrollerSRAMFail | Q Controller SRAM Failure. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.117 | NodealarmShaperSRAMFail | Shaper SRAM Failure. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.118 | NodealarmMulticastSRAMFail | Multicast SRAM Failure. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.119 | NodealarmBusAParityError | Bus A Parity Error. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.120 | NodealarmBusBParityError | Bus B Parity Error. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.121 | NodealarmBusCParityError | Bus C Parity Error. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.122 | NodealarmBusDParityError | Bus D Parity Error. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.123 | NodealarmBusEParityError | Bus E Parity Error. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.124 | NodealarmBusFParityError | Bus F Parity Error. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.125 | NodealarmLoss25MHzATMClock | Loss 25MHz ATM Clock. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.126 | NodealarmLoss8KHzRefClock | Loss 8KHz Ref Clock. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.127 | NodealarmLossBITSInputSignal | Loss BITS Input Signal. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.129 | NodealarmALMExtSSRAMFail | ALM Ext SSRAM Failure. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.130 | NodealarmALMIngrFIFOOverflow | ALM Ingress FIFO Overflow. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.131 | NodealarmALMDestSlotOverrun | ALM Dest Slot Overrun. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.132 | NodealarmALMIngrVPIOver255 | ALM Ingress VPI Over 255. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.133 | NodealarmALMIngrVCIOutRange | ALM Ingress VCI Out of Range. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.134 | NodealarmALMIngrSyncError | ALM Ingress Sync Error. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.135 | NodealarmALMParityErrEgrQCX | ALM Parity Error Egress/QController. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.136 | NodealarmALMParityErrIgrCB | ALM Parity Error Ingress/CB. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.137 | NodealarmALMExtSRAMParityEr | ALM Ext SRAM Parity Error. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.138 | NodealarmALMInsertFIFOError | ALM Insert FIFO Error. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.139 | NodealarmALMIgrCapFIFOError | ALM Ingress Cap FIFO Error. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.140 | NodealarmALMEgrCapFIFOError | ALM Egress Cap FIFO Error. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.141 | NodealarmCBRQOverThreshold | Queue 0 Over Threshold. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.142 | NodealarmVBRQOverThreshold | Queue 1 Over Threshold. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.143 | NodealarmABRQOverThreshold | Queue 2 Over Threshold. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.144 | NodealarmUBRQOverThreshold | Queue 3 Over Threshold. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.145 | NodealarmPerConnectionVcAIS | Per-Connection VC AIS. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.146 | NodealarmPerConnectionVcRDI | Per-Connection VC RDI. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.148 | NodealarmGrMultiTest | Multiple test procedure requests from different links of same group. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.149 | NodealarmGrConfigAbort | Group Near end config abort. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.150 | NodealarmGrInsufLink | Group Near end insufficient links. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.151 | NodealarmFeAbortSymm | Far end config abort due to bad symmetry. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.152 | NodealarmFeStartup | Far end start up. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.153 | NodealarmFeConfigAbort | Far end config abort due to bad M. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.154 | NodealarmFeInsufLink | Far end insufficient links. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.155 | NodealarmFeBlock | Far end blocked. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.156 | NodealarmGrTimeSynch | Group timing synchronization failed. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.157 | NodealarmGrLackLink | Group does not have enough links. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.158 | NodealarmImaPrtclMismtch | IMA protocol mismatch. Far end IMA group is not running compatible protocol. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.159 | NodealarmRemoteLpbk | IMA remote loopback. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.160 | NodealarmGroupAbortSymm | IMA group abort symmetry. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.161 | NodealarmMissIcpCells | Port Missing ICP Cells. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.162 | NodealarmSystemClkRevert | System Clock Reverted. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.163 | NodealarmTakeOverBySU | Write Session is taken by Super User. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.164 | NodealarmLinkUp | Link Up. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.165 | NodealarmLinkDown | Link Down. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.166 | NodealarmGrLinkUp | Group Link Up. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.167 | NodealarmGrLinkDown | Group Link Down. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.168 | NodealarmFwVerMismatch | Firmware Versions Mismatch. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.169 | NodealarmIdPromChkError | ID Prom Checksum Error. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.170 | NodealarmPwrSupply3Absent | Power Supply 3 absent. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.171 | NodealarmPwrSupply4Absent | Power Supply 4 absent. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.172 | NodealarmPwrSupply5Absent | Power Supply 5 absent. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.173 | NodealarmPwrSupply6Absent | Power Supply 6 absent. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.174 | NodealarmRcvdExtAlm1 | Received External Alarm 1. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.175 | NodealarmRcvdExtAlm2 | Received External Alarm 2. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.176 | NodealarmRcvdExtAlm3 | Received External Alarm 3. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.177 | NodealarmVCMRefClkFailur | VCM reference clock failure alarm. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.178 | NodealarmOC3LossOfPtr | OC3 Loss of Pointer. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.179 | NodealarmImaGrp1Reass | IMA Group 1 Reassigned to DS3. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.180 | NodealarmChnlPcmLpbk | Channel PCM Loopback. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.181 | NodealarmChnlPcmPktLpbk | Channel PCM Packet Loopback. | ||
| 1.3.6.1.4.1.2011.2.1.1.1.1.182 | NodealarmChnlNtwkPktLpbk | Channel Network Packet Loopback. |