CADANT-CMTS-PC-EVENTMSG-MIB
15 objects
PacketCable event message MIB. This MIB contains objects for PacketCable Event Messaging between the Cadant C4 CMTS and a record keeping server or distribution function.
Imported Objects
| CADANT-CMTS-PACKETCABLE-MIB | cadPCMibObjects |
| SNMPv2-SMI | Integer32 IpAddress MODULE-IDENTITY OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | RowStatus TEXTUAL-CONVENTION TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4998.1.1.115.1.5 | IdentitycadEvMsgMIB | PacketCable event message MIB. This MIB contains objects for PacketCable Event Messaging between the Cadant C4 CMTS and a record keeping server or distribution… | ||
| 1.3.6.1.4.1.4998.1.1.115.1.5.1 | NodecadEvMsgMibBase | |||
| 1.3.6.1.4.1.4998.1.1.115.1.5.1.1 | ScalarcadEvMsgElementType | read-only | current | Element type to be included in Event Message header. Default value 2 = CMTS. |
| 1.3.6.1.4.1.4998.1.1.115.1.5.1.2 | ScalarcadEvMsgElementId | read-write | current | Five digit Element ID to be included in Event Message header. Must be unique network-wide. |
| 1.3.6.1.4.1.4998.1.1.115.1.5.1.3 | ScalarcadEvMsgMaxAge | read-write | current | Maximum amount of time, in minutes, that an event message destined for the RKS may reside in the CMTS, for UDP-based batch mode. |
| 1.3.6.1.4.1.4998.1.1.115.1.5.1.4 | ScalarcadEvMsgRetransTimer | read-write | current | Maximum amount of time, in milliseconds, that the CMTS will wait for the RKS to acknowledge an event message before attempting to retransmit the message. |
| 1.3.6.1.4.1.4998.1.1.115.1.5.1.5 | ScalarcadEvMsgMaxRetry | read-write | current | Maximum number of retry attempts for transmitting an event message. If this value is set to 0, then we only try once. |
| 1.3.6.1.4.1.4998.1.1.115.1.5.1.6 | ScalarcadEvMsgMaxBatchSize | read-write | current | Maximum number of radius event messages that can be batched. This value must be set to greater than 1 to allow batching |
| 1.3.6.1.4.1.4998.1.1.115.1.5.1.7 | ScalarcadEvMsgEnableFlag | read-write | current | Boolean for enabling/disabling Event Messaging |
| 1.3.6.1.4.1.4998.1.1.115.1.5.2 | TablecadEvMsgTransTimeTable | not-accessible | current | Table of up to 24 time-of-day values for Event Messaging. |
| 1.3.6.1.4.1.4998.1.1.115.1.5.2.1 | RowcadEvMsgTransTimeEntry | not-accessible | current | This entry contains one row in the table. |
| 1.3.6.1.4.1.4998.1.1.115.1.5.2.1.1 | ColumncadEvMsgTransTimeIdx | not-accessible | current | An index into the cadEvMsgTransTimeTable. There can be up to 24 entries. |
| 1.3.6.1.4.1.4998.1.1.115.1.5.2.1.2 | ColumncadEvMsgTransTOD | read-create | current | Time of day to transmit Event Messages, in HH:MM format |
| 1.3.6.1.4.1.4998.1.1.115.1.5.2.1.3 | ColumncadEvMsgTransTimeStatus | read-create | current | Row status entry for the table. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| TimeOfDay | OCTET STRING (SIZE (0..5)) | current | A time-of-day specification in hours:minutes. field octets contents range 1 1 hour 0..23 2 1 minutes 0..59 |