CISCO-DM-MIB

91 objects
The MIB module for the domain management functionality defined by the Fibre Channel standards (FC-SW2). For the purposes of this MIB, 'Domain Manager' is the software functionality which executes in both the principal switch and other switches.
OIDNameAccessStatusDescription
1.3.6.1.4.1.9.9.302IdentityciscoDmMIBThe MIB module for the domain management functionality defined by the Fibre Channel standards (FC-SW2). For the purposes of this MIB, 'Domain Manager' is the s…
1.3.6.1.4.1.9.9.302.1NodeciscoDmMIBObjects
1.3.6.1.4.1.9.9.302.1.1NodedmConfiguration
1.3.6.1.4.1.9.9.302.1.1.1TabledmTablenot-accessiblecurrentThis table contains Domain Manager related parameters which can be configured and monitored. There is one entry for each of the VSANs configured on this switch…
1.3.6.1.4.1.9.9.302.1.1.1.1RowdmEntrynot-accessiblecurrentAn entry provides information on the domain manager for a VSAN.
1.3.6.1.4.1.9.9.302.1.1.1.1.1ColumndmConfigDomainIdread-writecurrentThe configured Domain ID of the local switch on this VSAN or zero if no Domain ID has been configured. The meaning of this object depends on dmConfigDomainIdTy…
1.3.6.1.4.1.9.9.302.1.1.1.1.2ColumndmConfigDomainIdTyperead-writecurrentType of configured Domain ID.
1.3.6.1.4.1.9.9.302.1.1.1.1.3ColumndmEnableread-writecurrentEnables the Domain Manager on this VSAN. If enabled on an active VSAN, the switch will participate in principal switch selection. If disabled, the switch will …
1.3.6.1.4.1.9.9.302.1.1.1.1.4ColumndmAutoReconfigureread-writecurrentThis object determines how the switch responds to certain error conditions. The condition that can cause these errors is merging of two disjoint fabrics that h…
1.3.6.1.4.1.9.9.302.1.1.1.1.5ColumndmContiguousAllocationread-writecurrentDetermines how the switch behaves when elected as the principal switch. If true, switch won't accept non-contiguous domain IDs in RDIs and will try to replace …
1.3.6.1.4.1.9.9.302.1.1.1.1.6ColumndmPriorityread-writecurrentPriority of the switch to be used in principal switch selection process.
1.3.6.1.4.1.9.9.302.1.1.1.1.7ColumndmRestartread-writecurrentThis object tells the Domain Manager to rebuild the Domain ID tree all over again. If this object is set to 'disruptive', then a RCF (ReConfigure Fabric) is ge…
1.3.6.1.4.1.9.9.302.1.1.1.1.8ColumndmFabricNameread-writecurrentThe WWN that is used for fabric logins on this VSAN. This object is used only if the value of dmEnable is false. If the value of dmEnable is true, then princip…
1.3.6.1.4.1.9.9.302.1.1.1.1.9ColumndmPrincipalSwitchWwnread-onlycurrentThe WWN of the Principal Switch on this VSAN, or zero-length string if the identity of the principal switch is unknown.
1.3.6.1.4.1.9.9.302.1.1.1.1.10ColumndmLocalSwitchWwnread-onlycurrentThe WWN of the local Switch on this VSAN.
1.3.6.1.4.1.9.9.302.1.1.1.1.11ColumndmAssignedAreaIdListread-onlycurrentThe list of Area IDs which have been assigned in this VSAN, formatted as an array of octets in ascending order. There could zero or more Area IDs assigned on t…
1.3.6.1.4.1.9.9.302.1.1.1.1.12ColumndmFcIdsGrantedread-onlycurrentThe total number of FC IDs that are granted (for local use) by the Domain Manager on the local switch since the switch has been initialized. Note that all such…
1.3.6.1.4.1.9.9.302.1.1.1.1.13ColumndmFcIdsRecoveredread-onlycurrentThe total number of FC IDs that are recovered by the Domain Manager on the local switch since the switch has been initialized. A recovered FC ID is one that is…
1.3.6.1.4.1.9.9.302.1.1.1.1.14ColumndmFreeFcIdsread-onlycurrentThe number of FC IDs that are unassigned on this VSAN.
1.3.6.1.4.1.9.9.302.1.1.1.1.15ColumndmAssignedFcIdsread-onlycurrentThe number of FC IDs that are assigned on this VSAN.
1.3.6.1.4.1.9.9.302.1.1.1.1.16ColumndmReservedFcIdsread-onlycurrentThe number of FC IDs that are reserved on this VSAN.
1.3.6.1.4.1.9.9.302.1.1.1.1.17ColumndmRunningPriorityread-onlycurrentThe running priority of the local switch on this VSAN.
1.3.6.1.4.1.9.9.302.1.1.1.1.18ColumndmPrincSwRunningPriorityread-onlycurrentThe running priority of the principal switch on this VSAN.
1.3.6.1.4.1.9.9.302.1.1.1.1.19ColumndmStateread-onlycurrentThe state of the Domain Manager on the local switch on this VSAN.
1.3.6.1.4.1.9.9.302.1.1.1.1.20ColumndmPrincipalSwitchSelectionsread-onlycurrentThe number of principal switch selections on this VSAN.
1.3.6.1.4.1.9.9.302.1.1.1.1.21ColumndmBuildFabricsread-onlycurrentThe number of 'BuildFabrics' (BFs) that have occurred on this VSAN.
1.3.6.1.4.1.9.9.302.1.1.1.1.22ColumndmFabricReconfiguresread-onlycurrentThe number of 'ReconfigureFabrics' (RCFs) that have occurred on this VSAN.
1.3.6.1.4.1.9.9.302.1.1.1.1.23ColumndmDomainIdread-onlycurrentThe Domain ID of the local switch on this VSAN or zero if no Domain ID has been assigned.
1.3.6.1.4.1.9.9.302.1.1.1.1.24ColumndmLocalPrincipalSwitchSelctnsread-onlycurrentThe number of times the local switch became the principal switch on this VSAN.
1.3.6.1.4.1.9.9.302.1.1.1.1.25ColumndmFcIdPersistencyread-writecurrentIndicates if the FC IDs assigned on this VSAN are persistent or not. If this object is set to 'true', then all the FC ID assigned on this VSAN are made persist…
1.3.6.1.4.1.9.9.302.1.1.1.1.26ColumndmFcIdPurgeread-writecurrentThis object tells the Domain Manager to purge the FC IDs on this VSAN in the FC ID persistency database. If the value of this object is 'enable', then the FC I…
1.3.6.1.4.1.9.9.302.1.1.1.1.27ColumndmOptimizeread-writecurrentEach 'bit' within the value of an object of this type, specifies a configured optimization type. The value of each 'bit' (set/reset) represents whether an opti…
1.3.6.1.4.1.9.9.302.1.1.2TabledmIfTablenot-accessiblecurrentThis table contains interface configuration of the domain manager per VSAN. An entry in this table is automatically created when an E_port becomes non-isolated…
1.3.6.1.4.1.9.9.302.1.1.2.1RowdmIfEntrynot-accessiblecurrentAn entry gives information on interface configuration on a particular VSAN.
1.3.6.1.4.1.9.9.302.1.1.2.1.1ColumndmIfRcfRejectread-createcurrentThis object determines if the incoming ReConfigure Fabric (RCF) messages on this interface on this vsan is accepted or not. If this object is 'true', then the …
1.3.6.1.4.1.9.9.302.1.1.2.1.2ColumndmIfRoleread-onlycurrentThe role of this interface.
1.3.6.1.4.1.9.9.302.1.1.2.1.3ColumndmIfRowStatusread-createcurrentThe status of this row. This object can be used to create an entry only if the corresponding interface exists. If the interface does not exists, a create will …
1.3.6.1.4.1.9.9.302.1.1.3ScalardmReConfFabricChangeNotifyEnableread-writecurrentSpecifies whether or not the local switch should issue a dmFabricChangeNotify notification on sending or receiving ReConfigureFabric (RCF) on a VSAN. If the va…
1.3.6.1.4.1.9.9.302.1.1.4TabledmFcIdPersistencyTablenot-accessiblecurrentThis table lists the FC IDs which are in the FC ID persistency database. The FC ID persistency is a feature which enables FC devices to get same FC IDs even if…
1.3.6.1.4.1.9.9.302.1.1.4.1RowdmFcIdPersistencyEntrynot-accessiblecurrentAn entry provides information about a persistent FC ID.
1.3.6.1.4.1.9.9.302.1.1.4.1.1ColumndmFcIdPersistencyWwnnot-accessiblecurrentThis is either the port WWN of the FC device if the local port is a F_port or WWN of the local port if the local port is a FL_port. The local port is the port …
1.3.6.1.4.1.9.9.302.1.1.4.1.2ColumndmFcIdPersistencyFcIdread-createcurrentThe FC ID assigned for this WWN on this VSAN. The third octet of this object must be '0x00' if value of dmFcIdPersistencyNum is 'area'. This object cannot be c…
1.3.6.1.4.1.9.9.302.1.1.4.1.3ColumndmFcIdPersistencyNumread-createcurrentThe number of FC IDs starting from 'dmFcIdPersistencyFcId' which are assigned either statically or dynamically for this WWN on this VSAN. The value 'one' means…
1.3.6.1.4.1.9.9.302.1.1.4.1.4ColumndmFcIdPersistencyUsedread-onlycurrentThis object indicates if this FC ID is used or not.
1.3.6.1.4.1.9.9.302.1.1.4.1.5ColumndmFcIdPersistencyTyperead-createcurrentThe type of persistency of this FC ID.
1.3.6.1.4.1.9.9.302.1.1.4.1.6ColumndmFcIdPersistencyRowStatusread-createcurrentStatus of this row. An entry cannot be created until following object is instantiated : - dmFcIdPersistencyFcId - dmFcIdPersistencyNum Note that an entry canno…
1.3.6.1.4.1.9.9.302.1.1.5TabledmAllowedDomainIDListTablenot-accessiblecurrentThis table contains list of allowed domain IDs in the local VSANs. So in a VSAN, domain IDs can be assigned only from the allowed list. All the domain IDs whic…
1.3.6.1.4.1.9.9.302.1.1.5.1RowdmAllowedDomainIDListEntrynot-accessiblecurrentAn entry (conceptual row) in this table. Each entry represents an domain ID list allowed in a VSAN.
1.3.6.1.4.1.9.9.302.1.1.5.1.1ColumndmAllowedDomainIDListIdnot-accessiblecurrentThe identifier of the domain ID list.
1.3.6.1.4.1.9.9.302.1.1.5.1.2ColumndmAllowedDomainIDListread-writecurrentThis object provides the lists of domains that are allowed. Each octet within the value of the object specifies a set of domains. The first octet specifies dom…
1.3.6.1.4.1.9.9.302.1.1.5.1.3ColumndmAllowedDomainIDListUserread-onlycurrentThe name of the entity using this domain ID list on this vsan.
1.3.6.1.4.1.9.9.302.1.2NodedmInfo
1.3.6.1.4.1.9.9.302.1.2.1TabledmAreaTablenot-accessiblecurrentThis table contains area statistics on this domain manager per VSAN. Each octet in the dmAssignedAreaList can be used to index this table to find information o…
1.3.6.1.4.1.9.9.302.1.2.1.1RowdmAreaEntrynot-accessiblecurrentAn entry gives information on the Area ID and all Port IDs that were assigned for within an area for a particular VSAN.
1.3.6.1.4.1.9.9.302.1.2.1.1.1ColumndmAreaAreaIdnot-accessiblecurrentThe Area ID of this area.
1.3.6.1.4.1.9.9.302.1.2.1.1.2ColumndmAreaAssignedPortIdListread-onlycurrentThe list of Port IDs which have been assigned in this Area and VSAN, formatted as an array of octets in ascending order. There could be zero or more Port IDs a…
1.3.6.1.4.1.9.9.302.1.2.2TabledmDatabaseTablenot-accessiblecurrentThis table contains all information known by the local switch about all the domains which have been assigned in each of the VSANs.
1.3.6.1.4.1.9.9.302.1.2.2.1RowdmDatabaseEntrynot-accessiblecurrentAn entry (conceptual row) in the dmDatabaseTable containing information about one Domain ID in one VSAN.
1.3.6.1.4.1.9.9.302.1.2.2.1.1ColumndmDatabaseDomainIdnot-accessiblecurrentThe Domain ID for which this row contains information.
1.3.6.1.4.1.9.9.302.1.2.2.1.2ColumndmDatabaseSwitchWwnread-onlycurrentThe WWN of the switch to which the corresponding value of dmDatabaseDomainId is currently assigned for the particular VSAN.
1.3.6.1.4.1.9.9.302.1.2.3ScalardmMaxFcIdCacheSizeread-onlycurrentThe maximum number of FC IDs that can be cached in the dmFcIdCacheTable.
1.3.6.1.4.1.9.9.302.1.2.4TabledmFcIdCacheTablenot-accessiblecurrentThis table contains all the FC IDs that have recently been released. So it lists all the FC IDs that have valid WWN to FC ID mappings and currently not assigne…
1.3.6.1.4.1.9.9.302.1.2.4.1RowdmFcIdCacheEntrynot-accessiblecurrentAn entry (conceptual row) in the dmFcIdCacheTable containing information about one FC ID that was released from a WWN, corresponding to a range of one or more …
1.3.6.1.4.1.9.9.302.1.2.4.1.1ColumndmFcIdCacheWwnnot-accessiblecurrentThe WWN of the port associated this entry.
1.3.6.1.4.1.9.9.302.1.2.4.1.2ColumndmFcIdCacheAreaIdPortIdread-onlycurrentThe Area ID and Port ID of FC ID that was assigned and has since been released by this port on this VSAN. Note that this object is only 2 bytes and only contai…
1.3.6.1.4.1.9.9.302.1.2.4.1.3ColumndmFcIdCachePortIdsread-onlycurrentNumber of port IDs assigned and/or released starting from Port ID contained in the second byte of dmFcIdCacheAreaIdPortId for the Area ID contained in the firs…
1.3.6.1.4.1.9.9.302.1.3NodedmNotificationPrefix
1.3.6.1.4.1.9.9.302.1.3.0NodedmNotification
1.3.6.1.4.1.9.9.302.1.3.0.1NotificationdmDomainIdNotAssignedNotifycurrentIf a Domain ID is not configured or assigned on a VSAN, then the switch may isolate E_ports on that VSAN. The conditions are : - If the Domain Manager is enabl…
1.3.6.1.4.1.9.9.302.1.3.0.2NotificationdmNewPrincipalSwitchNotifycurrentThis notification indicates that the sending switch has become the new Principal Switch on a VSAN. This notification is sent soon after its election as the new…
1.3.6.1.4.1.9.9.302.1.3.0.3NotificationdmFabricChangeNotifycurrentThis notification is sent whenever a switch sends or receives a Build Fabric (BF) or a ReConfigure Fabric (RCF) message on a VSAN. A switch can receive or issu…
1.3.6.1.4.1.9.9.302.2NodedmMIBConformance
1.3.6.1.4.1.9.9.302.2.1NodedmMIBCompliances
1.3.6.1.4.1.9.9.302.2.1.1CompliancedmMIBComplianceread-createdeprecatedThe compliance statement for entities which implement the Domain Manager.
1.3.6.1.4.1.9.9.302.2.1.2CompliancedmMIBCompliance1read-createdeprecatedThe compliance statement for entities which implement the Domain Manager.
1.3.6.1.4.1.9.9.302.2.1.3CompliancedmMIBCompliance2read-createdeprecatedThe compliance statement for entities which implement the Domain Manager.
1.3.6.1.4.1.9.9.302.2.1.4CompliancedmMIBCompliance3read-createcurrentThe compliance statement for entities which implement the Domain Manager.
1.3.6.1.4.1.9.9.302.2.2NodedmMIBGroups
1.3.6.1.4.1.9.9.302.2.2.1GroupdmGroupdeprecatedA collection of objects for displaying and configuring Domain Manager membership. dmGroup object is superseded by dmGroupRev2.
1.3.6.1.4.1.9.9.302.2.2.2GroupdmDatabaseGroupcurrentA collection of objects for displaying the Domain database information.
1.3.6.1.4.1.9.9.302.2.2.3GroupdmAreaGroupcurrentA collection of objects for displaying the Domain area information.
1.3.6.1.4.1.9.9.302.2.2.4GroupdmCacheGroupcurrentA collection of objects for displaying the Domain area information.
1.3.6.1.4.1.9.9.302.2.2.5GroupdmNotificationGroupcurrentA collection of notifications for status monitoring and notification.
1.3.6.1.4.1.9.9.302.2.2.6GroupdmGroupRev1deprecatedA collection of objects for displaying and configuring Domain Manager membership. dmGroupRev1 object is superseded by dmGroupRev2.
1.3.6.1.4.1.9.9.302.2.2.7GroupdmFcIdPersistencyGroupcurrentA collection of objects to support FC ID persistency.
1.3.6.1.4.1.9.9.302.2.2.8GroupdmDomainIDAllowedGroupcurrentA collection of objects to support domain ID list feature.
1.3.6.1.4.1.9.9.302.2.2.9GroupdmGroupRev2currentA collection of objects for displaying and configuring Domain Manager membership.
Type Definitions
NameSyntaxStatusDescription
DmStateINTEGER { starting(1), unconfigured(2), principalSwitchSelection(3), domainIdDistribution(4), buildFabricPhase(5), reconfigureFabricPhase(6), stable(7), stableWithNoEports(8), stableWithDomainConfigured(9), noDomains(10), disabled(11), suspended(12), unknown(13) }currentState of the Domain Manager. starting(1)- unconfigured(2) - principalSwitchSelection(3) - principal switch - selection in progress. domainIdDistribution(4) - domain ID distribution - in progress. buildFabricPhase(5) - B…
DomainInterfaceRoleINTEGER { nonPrincipal(1), principalUpstream(2), principalDownsteam(3), isolated(4), down(5), unknown(6) }currentRole of the Domain Manager interface. nonPrincipal (1) - non-principal interface principalUpstream (2) - upstream principal interface principalDownsteam (3) - downstream principal interface isolated (4) - isolated inter…
DomainPriorityUnsigned32 (1..255)currentPriority of the switch. The principal switch selection is influenced by the priority of the switch. Some values are of importance are: 1 : The highest priority in principal switch selection and is used by the user to es…
DomainPriorityOrZeroInteger32 (0..255)currentThis is an extension of the DomainPriority. In addition to the DomainPriority range, this also includes 0 in its range of values. The value '0' means that the priority is not known. If the meaning is different from this…