CISCO-MPLS-TE-STD-EXT-MIB
75 objects
This MIB module contains Cisco specific managed object definitions for MPLS Traffic Engineering (TE), not contained in MPLS-TE-STD-MIB. The auto bandwidth feature enables MPLS TE Tunnels to adapt automatically their bandwidth to their actual load.
Imported Objects
| CISCO-SMI | ciscoMgmt |
| INET-ADDRESS-MIB | InetAddress InetAddressType |
| MPLS-TE-STD-MIB | mplsTunnelAdminStatus mplsTunnelARHopListIndex mplsTunnelEgressLSRId mplsTunnelIndex mplsTunnelIngressLSRId mplsTunnelInstance mplsTunnelName mplsTunnelOperStatus |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Counter32 Gauge32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.9.9.738 | IdentitycmplsTeStdExtMIB | in | This MIB module contains Cisco specific managed object definitions for MPLS Traffic Engineering (TE), not contained in MPLS-TE-STD-MIB. The auto bandwidth feat… | |
| 1.3.6.1.4.1.9.9.738.0 | NodecmplsTeStdExtMIBNotifs | |||
| 1.3.6.1.4.1.9.9.738.0.1 | NotificationcmplsTunnelPreempt | current | This notification is generated when a MPLS TE tunnel is preempted. | |
| 1.3.6.1.4.1.9.9.738.0.2 | NotificationcmplsTunnelInsuffBW | current | This notification is generated when a MPLS TE tunnel could not be setup or reoptimized. | |
| 1.3.6.1.4.1.9.9.738.0.3 | NotificationcmplsTunnelReRoutePending | current | This notification is generated when re-route is required for the tunnel. | |
| 1.3.6.1.4.1.9.9.738.0.4 | NotificationcmplsTunnelReRoutePendingClear | current | This notification is generated when tunnel no longer needs to be re-routed. | |
| 1.3.6.1.4.1.9.9.738.0.5 | NotificationcmplsTunnelBringupFail | current | This notification is generated when MPLS TE tunnel failed to come up | |
| 1.3.6.1.4.1.9.9.738.1 | NodecmplsTeStdExtMIBObjects | |||
| 1.3.6.1.4.1.9.9.738.1.1 | TablecmplsTunnelAutoBWTable | not-accessible | current | This table is used in order to manage auto bandwidth data. This table is sparse dependent on the mplsTunnelTable. An entry in this table exists for each mplsTu… |
| 1.3.6.1.4.1.9.9.738.1.1.1 | RowcmplsTunnelAutoBWEntry | not-accessible | current | A conceptual row in cmplsTunnelAutoBWTable. There is an entry in this table for each MPLS-TE tunnel with mplsTunnelRole equals to 'head' or 'headTail'. |
| 1.3.6.1.4.1.9.9.738.1.1.1.1 | ColumncmplsTunnelAutoBWStatus | read-only | current | This object indicates the operational status [or mode] of the auto bandwidth algorithm: - autoBWDisabled: The auto-bandwidth algorithm is not running; - autoBW… |
| 1.3.6.1.4.1.9.9.738.1.1.1.2 | ColumncmplsTunnelAutoBWMin | read-write | current | This object specifies the minimum bandwidth that the auto-bandwidth algorithm can apply to a tunnel when the adjustment threshold is overcome. This object valu… |
| 1.3.6.1.4.1.9.9.738.1.1.1.3 | ColumncmplsTunnelAutoBWMax | read-write | current | This object specifies the maximum bandwidth that the auto-bandwidth algorithm can apply to a tunnel when the adjustment threshold is overcome. This object valu… |
| 1.3.6.1.4.1.9.9.738.1.1.1.4 | ColumncmplsTunnelAutoBWAdjThreshPercs | read-write | current | This object specifies the adjustment threshold percentage that needs to be overcome in order to trigger a new bandwidth application. This object value is not a… |
| 1.3.6.1.4.1.9.9.738.1.1.1.5 | ColumncmplsTunnelAutoBWAdjThreshBW | read-write | current | This object specifies the adjustment threshold bandwidth that needs to be overcome in order to trigger a new bandwidth application. This object value is not ap… |
| 1.3.6.1.4.1.9.9.738.1.1.1.6 | ColumncmplsTunnelAutoBWOverflowThreshPercs | read-write | current | This object specifies the adjustment threshold percentage that needs to be overcome in order to trigger an overflow occurrence. If the application period has n… |
| 1.3.6.1.4.1.9.9.738.1.1.1.7 | ColumncmplsTunnelAutoBWOverflowThreshBW | read-write | current | This object specifies the adjustment threshold bandwidth that needs to be overcome in order to trigger an overflow occurrence. If the application period has no… |
| 1.3.6.1.4.1.9.9.738.1.1.1.8 | ColumncmplsTunnelAutoBWOverflowLimit | read-write | current | This object specifies the number of consecutive collections exceeding overflow threshold. If the application period has not completed when a cmplsTunnelAutoBWO… |
| 1.3.6.1.4.1.9.9.738.1.1.1.9 | ColumncmplsTunnelAutoBWUnderflowThreshPercs | read-write | current | This object specifies the adjustment threshold percentage that needs to be overcome in order to trigger an underflow occurrence. If the application period has … |
| 1.3.6.1.4.1.9.9.738.1.1.1.10 | ColumncmplsTunnelAutoBWUnderflowThreshBW | read-write | current | This object specifies the adjustment threshold bandwidth that needs to be overcome in order to trigger an underflow occurrence. If the application period has n… |
| 1.3.6.1.4.1.9.9.738.1.1.1.11 | ColumncmplsTunnelAutoBWUnderflowLimit | read-write | current | This object specifies the number of consecutive collections under the underflow threshold. If the application period has not completed when a cmplsTunnelAutoBW… |
| 1.3.6.1.4.1.9.9.738.1.1.1.12 | ColumncmplsTunnelAutoBWApplicationFrequency | read-write | current | This object specifies the bandwidth application period. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. |
| 1.3.6.1.4.1.9.9.738.1.1.1.13 | ColumncmplsTunnelAutoBWCollectionFrequency | read-write | current | This object specifies the sampling period for data rates. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. |
| 1.3.6.1.4.1.9.9.738.1.1.1.14 | ColumncmplsTunnelAutoBWLastAppliedBW | read-only | current | This object indicates the last bandwidth applied by the auto-bandwidth algorithm. It will be set to zero if no bandwidth has been applied yet. If mplsTunnelIns… |
| 1.3.6.1.4.1.9.9.738.1.1.1.15 | ColumncmplsTunnelAutoBWApplications | read-only | current | This object indicates the number of auto bandwidths applied. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable … |
| 1.3.6.1.4.1.9.9.738.1.1.1.16 | ColumncmplsTunnelAutoBWLastApplicationTrigger | read-only | current | This object indicates the trigger reason for the last bandwidth application. If mplsTunnelInstance is zero this object will be set to 'applicationNone'. This o… |
| 1.3.6.1.4.1.9.9.738.1.1.1.17 | ColumncmplsTunnelAutoBWOverflowApplications | read-only | current | This object indicates the number of bandwidth applications due to overflow occurrences. If mplsTunnelInstance is zero this object will be set to zero. This obj… |
| 1.3.6.1.4.1.9.9.738.1.1.1.18 | ColumncmplsTunnelAutoBWOverflowOccurrences | read-only | current | This object indicates the number of overflow occurrences since last application period. If mplsTunnelInstance is zero this object will be set to zero. This obj… |
| 1.3.6.1.4.1.9.9.738.1.1.1.19 | ColumncmplsTunnelAutoBWUnderflowApplications | read-only | current | This object indicates the number of bandwidth applications due to underflow occurrences. If mplsTunnelInstance is zero this object will be set to zero. This ob… |
| 1.3.6.1.4.1.9.9.738.1.1.1.20 | ColumncmplsTunnelAutoBWUnderflowOccurrences | read-only | current | This object indicates the number of underflow occurrences since last application period. If mplsTunnelInstance is zero this object will be set to zero. This ob… |
| 1.3.6.1.4.1.9.9.738.1.1.1.21 | ColumncmplsTunnelAutoBWUnderflowHighestBW | read-only | current | This object indicates the highest sample collected during an underflow sequence. If mplsTunnelInstance is zero this object will be set to zero. This object val… |
| 1.3.6.1.4.1.9.9.738.1.1.1.22 | ColumncmplsTunnelAutoBWRequested | read-only | current | This object indicates the bandwidth requested by the auto-bandwidth algorithm. If mplsTunnelInstance is zero this object will be set to zero. This object value… |
| 1.3.6.1.4.1.9.9.738.1.1.1.23 | ColumncmplsTunnelAutoBWSignaled | read-only | current | This object indicates the bandwidth signaled by the auto-bandwidth algorithm. If mplsTunnelInstance is zero this object will be set to zero. This object value … |
| 1.3.6.1.4.1.9.9.738.1.1.1.24 | ColumncmplsTunnelAutoBWCollectOnlyRequested | read-only | current | This object indicates the bandwidth that would have been requested by the auto-bandwidth algorithm if the auto-bandwidth functionality was enabled. If the coll… |
| 1.3.6.1.4.1.9.9.738.1.1.1.25 | ColumncmplsTunnelAutoBWHighest | read-only | current | This object indicates the highest bandwidth sampled by the auto-bandwidth algorithm. If mplsTunnelInstance is zero this object will be set to zero. This object… |
| 1.3.6.1.4.1.9.9.738.1.1.1.26 | ColumncmplsTunnelAutoBWCollectedSamples | read-only | current | This object indicates the samples collected since the last auto-bandwidth application. If mplsTunnelInstance is zero this object will be set to zero. This obje… |
| 1.3.6.1.4.1.9.9.738.1.1.1.27 | ColumncmplsTunnelAutoBWJitter | read-only | current | This object indicates the auto-bandwidth application jitter. Jitter is the extra time to be added to the application interval the first time the auto bandwidth… |
| 1.3.6.1.4.1.9.9.738.1.1.1.28 | ColumncmplsTunnelAutoBWAppRejectReason | read-only | current | This object indicates the reason for the bandwidth application rejection. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'. |
| 1.3.6.1.4.1.9.9.738.1.2 | TablecmplsTeTunnelReasonTable | not-accessible | current | This table is used in order to indicate the causes for the notifications. |
| 1.3.6.1.4.1.9.9.738.1.2.1 | RowcmplsTeTunnelReasonEntry | not-accessible | current | A conceptual row in cmplsTunnelReasonTable. |
| 1.3.6.1.4.1.9.9.738.1.2.1.1 | ColumncmplsTunnelReoptReason | accessible-for-notify | current | This object indicates the reason of the tunnel reoptimization: - unknown: the reason is not known - periodicTimerExpiry: Periodic Reoptimization - bandwidthCLI… |
| 1.3.6.1.4.1.9.9.738.1.2.1.2 | ColumncmplsTunnelInsuffBWFailedOperation | accessible-for-notify | current | This object indicates whether the tunnel could not be setup or reoptimized because of insufficient bandwidth: - unknown: the reason is not known - failedToSetu… |
| 1.3.6.1.4.1.9.9.738.1.2.1.3 | ColumncmplsTunnelPreemptionType | accessible-for-notify | current | This object indicates LSP Preemption type of this LSP: - unknown: the type is not known - hardPreemption: the preempted LSP resources are freed immediately; th… |
| 1.3.6.1.4.1.9.9.738.1.2.1.4 | ColumncmplsTunnelPreemptionLinkAddrType | accessible-for-notify | current | This object indicates the address type of the link where the preemption occurs - another, higher priority LSP is being admitted on this link and there is not e… |
| 1.3.6.1.4.1.9.9.738.1.2.1.5 | ColumncmplsTunnelPreemptionLinkAddr | accessible-for-notify | current | This object indicates the address of the link where the preemption occurs - another, higher priority LSP is being admitted on this link and there is not enough… |
| 1.3.6.1.4.1.9.9.738.1.2.1.6 | ColumncmplsTunnelReRoutePendingClearReason | accessible-for-notify | current | This object indicates the reason why the tunnel is not longer in the reroute pending state: - unknown: the reason is unknown - reoptimized: the tunnel has been… |
| 1.3.6.1.4.1.9.9.738.1.3 | TablecmplsTeTunnelFailReasonTable | not-accessible | current | This table is used in order to indicate the causes for the MPLS TE tunnel failure notifications. |
| 1.3.6.1.4.1.9.9.738.1.3.1 | RowcmplsTeTunnelFailReasonEntry | not-accessible | current | A conceptual row in the cmplsTeTunnelFailReasonTable. |
| 1.3.6.1.4.1.9.9.738.1.3.1.1 | ColumncmplsTeFailReasonType | read-only | current | This object indicates the type (category) of fail reason. |
| 1.3.6.1.4.1.9.9.738.1.3.1.2 | ColumncmplsTeFailReason | read-only | deprecated | This object indicates specific fail reason value based on the fail reason type indicated by cmplsTeFailReasonType. Fail Reason Type Fail Reason Value Type bfd(… |
| 1.3.6.1.4.1.9.9.738.1.3.1.3 | ColumncmplsTeFailReasonRev | accessible-for-notify | current | This object provieds more deails on fail reason. cmplsTeFailReason values for reasonType bfd(2) mirror the CiscoBfdDiag values: - noDiagnostic No bfd diagnosti… |
| 1.3.6.1.4.1.9.9.738.1.4 | TablecmplsTunnelLoadshareTable | not-accessible | current | This table is used in order to manage load data. |
| 1.3.6.1.4.1.9.9.738.1.4.1 | RowcmplsTunnelLoadshareEntry | not-accessible | current | A conceptual row in cmplsTunnelLoadshareTable. There is an entry in this table for each MPLS-TE tunnel. |
| 1.3.6.1.4.1.9.9.738.1.4.1.1 | ColumncmplsTunnelLoadShare | read-write | current | This object indicates the Load-share as defined by the bandwidth attribute (default) or explicitly configured using the load-share command under tunnel configu… |
| 1.3.6.1.4.1.9.9.738.1.5 | NodecmplsTeStdExtMIBObjectsGlobal | |||
| 1.3.6.1.4.1.9.9.738.1.5.1 | ScalarcmplsTeLoadshareBalance | read-write | current | This object indicates if the load-share balance is equal or unequal. |
| 1.3.6.1.4.1.9.9.738.2 | NodecmplsTeStdExtMIBConform | |||
| 1.3.6.1.4.1.9.9.738.2.1 | NodecmplsTeStdExtMIBCompliances | |||
| 1.3.6.1.4.1.9.9.738.2.1.1 | CompliancecmplsTeStdExtMIBCompliance | deprecated | This is the main compliance statement for the MIB. | |
| 1.3.6.1.4.1.9.9.738.2.1.2 | CompliancecmplsTeStdExtMIBCompliancesRev1 | deprecated | This is the main compliance statement for the MIB. Adding the extended traps. | |
| 1.3.6.1.4.1.9.9.738.2.1.3 | CompliancecmplsTeStdExtMIBComplianceRev2 | deprecated | This is the main compliance statement for the MIB | |
| 1.3.6.1.4.1.9.9.738.2.1.4 | CompliancecmplsTeStdExtMIBComplianceRev3 | deprecated | This is the main compliance statement for the MIB | |
| 1.3.6.1.4.1.9.9.738.2.1.5 | CompliancecmplsTeStdExtMIBComplianceRev4 | accessible-for-notify | current | This is the main compliance statement for the MIB |
| 1.3.6.1.4.1.9.9.738.2.2 | NodecmplsTeStdExtMIBGroups | |||
| 1.3.6.1.4.1.9.9.738.2.2.1 | GroupcmplsTeStdExtMIBAutoBWObjectGroup | current | This contains the main MPLS TE extensions groups. | |
| 1.3.6.1.4.1.9.9.738.2.2.2 | GroupcmplsTeStdExtMIBAutoBWOptionalGroup | current | This contains the optional MPLS TE extensions groups. | |
| 1.3.6.1.4.1.9.9.738.2.2.3 | GroupcmplsTeStdExtMIBTrapObjectsGroup | deprecated | This contains the MPLS TE extended traps objects. This object is replaced by cmplsTeStdExtMIBTrapObjectsGroupRev1 | |
| 1.3.6.1.4.1.9.9.738.2.2.4 | GroupcmplsTeStdExtMIBTrapObjectsGroupRev1 | current | This contains the optional MPLS TE extensions groups. | |
| 1.3.6.1.4.1.9.9.738.2.2.5 | GroupcmplsTeStdExtMIBTrapGroup | current | This contains the MPLS TE extended traps. | |
| 1.3.6.1.4.1.9.9.738.2.2.6 | GroupcmplsTeStdExtMIBFailTeTrapGroup | current | This contains the MPLS TE extended traps related to BFD over TE LSP. | |
| 1.3.6.1.4.1.9.9.738.2.2.7 | GroupcmplsTeStdExtMIBFailTeTrapObjectsGroup | deprecated | This contains the MPLS TE extended traps objects related to BFD over TE LSP. This object is replaced by cmplsTeStdExtMIBFailTeTrapObjectsGroupRev1 | |
| 1.3.6.1.4.1.9.9.738.2.2.8 | GroupcmplsTeStdExtMIBLoadShareObjectsGroup | current | This contains the MPLS TE extended objects related to TE loadshare. | |
| 1.3.6.1.4.1.9.9.738.2.2.9 | GroupcmplsTeStdExtMIBFailTeTrapObjectsGroupRev1 | current | This contains the MPLS TE extended traps objects related to BFD over TE LSP. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| CmplsTeTunnelDiag | INTEGER { unknonw(1), bfdSessionBringupTimeout(2) } | current | A common TE diagnostic code - unknown: failure reason unknown - bfdSessionBringupTimeout: BFD session failed to come up before timeout |
| CmplsTunnelBWPercent | Unsigned32 (0..100) | current | A fraction of the bandwidth expressed in percentage. |