CISCO-POWER-ETHERNET-EXT-MIB

85 objects
A MIB module for extending the POWER-ETHERNET-MIB (RFC3621) to add objects which provide additional management information about Power Sourcing Equipment (PSE) not available in POWER-ETHERNET-MIB. Glossary Power Sourcing Equipment (PSE) These are devices supplying electrical power to other equipment. They are, for example, inline power switches, inline power daughterboards and power patch panels. Powered Device (PD) These are devices receiving their electrical power supply from Power Sourcing Equipment. They are, for example, IP telephones and wireless access points or bridges.
OIDNameAccessStatusDescription
1.3.6.1.4.1.9.9.402IdentityciscoPowerEthernetExtMIBA MIB module for extending the POWER-ETHERNET-MIB (RFC3621) to add objects which provide additional management information about Power Sourcing Equipment (PSE)…
1.3.6.1.4.1.9.9.402.0NodecpeExtMIBNotifs
1.3.6.1.4.1.9.9.402.0.1NotificationcpeExtPolicingNotifcurrentThis notification is generated when the 'overdraw' or 'overdrawLog' bit in value of cpeExtPsePortAdditionalStatus is set or cleared.
1.3.6.1.4.1.9.9.402.1NodecpeExtMIBObjects
1.3.6.1.4.1.9.9.402.1.1ScalarcpeExtDefaultAllocationread-writecurrentThis object indicates the default inline power allocation per port. This is a global configuration parameter that applies to all inline power capable ports in …
1.3.6.1.4.1.9.9.402.1.2TablecpeExtPsePortTablenot-accessiblecurrentThis table extends the POWER-ETHERNET-MIB pethPsePortTable for power Ethernet ports on a Powered Sourcing Equipment (PSE) device.
1.3.6.1.4.1.9.9.402.1.2.1RowcpeExtPsePortEntrynot-accessiblecurrentA cpeExtPsePortEntry extends a corresponding pethPsePortTable entry. This entry displays and controls more characteristics of a power Ethernet port on a PSE de…
1.3.6.1.4.1.9.9.402.1.2.1.1ColumncpeExtPsePortEnableread-writecurrentThis object is an extension of the pethPsePortAdminEnable object from RFC3621. It allows the user to be more specific when enabling the PSE functions. The stat…
1.3.6.1.4.1.9.9.402.1.2.1.2ColumncpeExtPsePortDiscoverModeread-onlycurrentThis object indicates the discover mode used by the system to discover the PD. A value of 'unknown' indicates that the discover mode on the interface is unknow…
1.3.6.1.4.1.9.9.402.1.2.1.3ColumncpeExtPsePortDeviceDetectedread-onlycurrentThis object indicates if a Powered Device (PD) has been detected on the interface. A value of 'true' indicates that a PD has been detected on the interface. A …
1.3.6.1.4.1.9.9.402.1.2.1.4ColumncpeExtPsePortIeeePdread-onlycurrentThis object indicates whether the Powered Device attached to the interface is an IEEE compliant Powered Device or not. A value of 'true' indicates the attached…
1.3.6.1.4.1.9.9.402.1.2.1.5ColumncpeExtPsePortAdditionalStatusread-onlycurrentThis object is an extension of the pethPsePortDetectionStatus object from RFC3621 and provides additional status information. deny: When set, the PD attached t…
1.3.6.1.4.1.9.9.402.1.2.1.6ColumncpeExtPsePortPwrMaxread-writecurrentThis indicates the maximum amount of power that the PSE will make available to the PD connected to this interface.
1.3.6.1.4.1.9.9.402.1.2.1.7ColumncpeExtPsePortPwrAllocatedread-onlycurrentThis object indicates the amount of power allocated from the PSE for the PD.
1.3.6.1.4.1.9.9.402.1.2.1.8ColumncpeExtPsePortPwrAvailableread-onlycurrentThis object indicates the amount of power available for the PD to use. This value may differ from the value cpeExtPsePortPwrAllocated due to the efficiency iss…
1.3.6.1.4.1.9.9.402.1.2.1.9ColumncpeExtPsePortPwrConsumptionread-onlycurrentThis indicates the actual power consumption of the PD connected to this interface. It may not necessarily be equal to the value of cpeExtPsePortPwrAvailable.
1.3.6.1.4.1.9.9.402.1.2.1.10ColumncpeExtPsePortMaxPwrDrawnread-onlycurrentThis indicates the maximum amount of power drawn by the PD connected to this interface, since it was powered on.
1.3.6.1.4.1.9.9.402.1.2.1.11ColumncpeExtPsePortEntPhyIndexread-onlycurrentThe entPhysicalIndex value that uniquely identifies the PSE port. If the PSE port does not have a corresponding physical entry in entPhysicalTable or if the en…
1.3.6.1.4.1.9.9.402.1.2.1.12ColumncpeExtPsePortPolicingCapableread-onlycurrentThis object indicates whether the PSE port hardware is capable of policing the port for proper power consumption based on the allocated value.
1.3.6.1.4.1.9.9.402.1.2.1.13ColumncpeExtPsePortPolicingEnableread-writecurrentThis object allows the user to turn on or turn off the power policing of the PSE port. If the instance value of cpeExtPsePortPolicingCapable is 'TRUE', the use…
1.3.6.1.4.1.9.9.402.1.2.1.14ColumncpeExtPsePortPolicingActionread-writecurrentThis object specifies the power policing action that the device will take on this PSE port when the real-time power consumption exceeds its max power allocatio…
1.3.6.1.4.1.9.9.402.1.2.1.15ColumncpeExtPsePortPwrManAllocread-writecurrentThis object specifies the manual power allocation that the PSE will allocate to the PD connected to this interface regardless of the amount requested via CDP o…
1.3.6.1.4.1.9.9.402.1.2.1.16ColumncpeExtPsePortCapabilitiesread-onlycurrentThis object indicates the PSE functionality that this port supports. If the 'policing' BIT is set, then this PSE port is capable of policing the port for prope…
1.3.6.1.4.1.9.9.402.1.3TablecpeExtMainPseTablenot-accessiblecurrentThis table contains the additional information for the main PSE group in pethMainPseTable.
1.3.6.1.4.1.9.9.402.1.3.1RowcpeExtMainPseEntrynot-accessiblecurrentA cpeExtMainPseEntry contains information about a particular pethMainPseGroupIndex. An entry is created by the agent when a main PSE group is added to the peth…
1.3.6.1.4.1.9.9.402.1.3.1.1ColumncpeExtMainPseEntPhyIndexread-onlycurrentThe entPhysicalIndex value that uniquely identifies the main PSE group. If the main PSE group does not have a corresponding physical entry in entPhysicalTable …
1.3.6.1.4.1.9.9.402.1.3.1.2ColumncpeExtMainPseDescrread-onlycurrentA textual string containing information about the Power Source Equipment (PSE) group.
1.3.6.1.4.1.9.9.402.1.3.1.3ColumncpeExtMainPsePwrMonitorCapableread-onlycurrentThis object indicates if the given group is capable of monitoring the power consumption of the interfaces that belong to the group. The value 'true' means that…
1.3.6.1.4.1.9.9.402.1.3.1.4ColumncpeExtMainPseUsedPowerread-onlycurrentThis object indicates used power expressed in miliwatts.
1.3.6.1.4.1.9.9.402.1.3.1.5ColumncpeExtMainPseRemainingPowerread-onlycurrentThis object indicates remaining power expressed in miliwatts, this parameter is calculated as pethMainPsePower minus cpeExtMainPseUsedPower.
1.3.6.1.4.1.9.9.402.1.4NodecpeExtPdStatistics
1.3.6.1.4.1.9.9.402.1.4.1ScalarcpeExtPdStatsTotalDevicesread-onlycurrentThis object indicates the total number of the powered devices with any power classifications in the system. Classification is a way to tag different terminals …
1.3.6.1.4.1.9.9.402.1.4.2TablecpeExtPdStatsTablenot-accessiblecurrentThis table contains the statistics information of the powered devices fallen into different power classifications in the system.
1.3.6.1.4.1.9.9.402.1.4.2.1RowcpeExtPdStatsEntrynot-accessiblecurrentA cpeExtPdStatsEntry contains the statistics information about a particular power classification defined in cpeExtPdStatsIndex.
1.3.6.1.4.1.9.9.402.1.4.2.1.1ColumncpeExtPdStatsClassnot-accessiblecurrentThe power classification as the index for the statistics information for powered devices. A value of 'cisco' indicates that the powered devices are CISCO propr…
1.3.6.1.4.1.9.9.402.1.4.2.1.2ColumncpeExtPdStatsDeviceCountread-onlycurrentThis object indicates the count of the powered devices whose power classification falls into a specific value of cpeExtPdStatsIndex.
1.3.6.1.4.1.9.9.402.1.5ScalarcpeExtPolicingNotifEnableread-writecurrentThis object is used to enable/disable the the cpeExtPolicingNotif notification.
1.3.6.1.4.1.9.9.402.1.6ScalarcpeExtPowerPriorityEnableread-writecurrentThis object is the global control of the power priority feature on the device. 'true' indicates that the power priority feature is globally enabled. 'false' in…
1.3.6.1.4.1.9.9.402.1.7TablecpeExtPsePortLldpTablenot-accessiblecurrentA table provides the Link Layer Discovery Protocol (LLDP) based Data Link Layer (DLL) power classification characteristics of PSE ports and PDs attached to the…
1.3.6.1.4.1.9.9.402.1.7.1RowcpeExtPsePortLldpEntrynot-accessiblecurrentA cpeExtPsePortLldpEntry entry contains the LLDP based 802.3at DLL power classification characteristics for a particular PSE and the PD attached to it. A PSE h…
1.3.6.1.4.1.9.9.402.1.7.1.1ColumncpeExtPsePortLldpPwrTyperead-onlycurrentThe DTE Power via MDI type of the local system (PSE).
1.3.6.1.4.1.9.9.402.1.7.1.2ColumncpeExtPsePortLldpPdPwrTyperead-onlycurrentThe DTE Power via MDI type of the remote system (PD).
1.3.6.1.4.1.9.9.402.1.7.1.3ColumncpeExtPsePortLldpPwrSrcread-onlycurrentThe power source of the local system (PSE).
1.3.6.1.4.1.9.9.402.1.7.1.4ColumncpeExtPsePortLldpPdPwrSrcread-onlycurrentThe power source of the remote system (PD).
1.3.6.1.4.1.9.9.402.1.7.1.5ColumncpeExtPsePortLldpPwrPriorityread-onlycurrentThe power priority of the local system (PSE).
1.3.6.1.4.1.9.9.402.1.7.1.6ColumncpeExtPsePortLldpPdPwrPriorityread-onlycurrentThe power priority of the remote system (PD).
1.3.6.1.4.1.9.9.402.1.7.1.7ColumncpeExtPsePortLldpPwrReqread-onlycurrentThe requested PD power value that the local system (PSE) mirrors back to the remote system (PD).
1.3.6.1.4.1.9.9.402.1.7.1.8ColumncpeExtPsePortLldpPdPwrReqread-onlycurrentThe PD requested power value received from the remote system (PD).
1.3.6.1.4.1.9.9.402.1.7.1.9ColumncpeExtPsePortLldpPwrAllocread-onlycurrentThe PSE allocated power value for the remote system (PD).
1.3.6.1.4.1.9.9.402.1.7.1.10ColumncpeExtPsePortLldpPdPwrAllocread-onlycurrentThe PSE allocated power value received from the remote system (PD).
1.3.6.1.4.1.9.9.402.1.7.1.11ColumncpeExtPsePortLldpPwrClassread-onlycurrentThe PSE power classification sent to the remote PD via MDI TLV in LLDP Protocol.
1.3.6.1.4.1.9.9.402.1.7.1.12ColumncpeExtPsePortLldpPdPwrClassread-onlycurrentThis power classification received from the remote system (PD).
1.3.6.1.4.1.9.9.402.1.7.1.13ColumncpeExtPsePortLldpPdPwrSupportread-onlycurrentThis object indicates the power support mode received from the remote PD via MDI TLV in LLDP protocol. 'portClass' - This bit is set if the port is operating a…
1.3.6.1.4.1.9.9.402.1.7.1.14ColumncpeExtPsePortLldpPdPwrPairsOrZeroread-onlycurrentThis object indicates the pinout pairs in use received from the remote PD via MDI TLV in LLDP Protocol. 'unknown' - information is not available 'signal' - the…
1.3.6.1.4.1.9.9.402.2NodecpeExtMIBConformance
1.3.6.1.4.1.9.9.402.2.1NodecpeExtMIBCompliances
1.3.6.1.4.1.9.9.402.2.1.1CompliancecpeExtMIBCompliancedeprecatedThe compliance statement for the CISCO-POWER-ETHERNET-EXT-MIB.
1.3.6.1.4.1.9.9.402.2.1.2CompliancecpeExtMIBCompliance2deprecatedThe compliance statement for the CISCO-POWER-ETHERNET-EXT-MIB.
1.3.6.1.4.1.9.9.402.2.1.3CompliancecpeExtMIBCompliance3deprecatedThe compliance statement for the CISCO-POWER-ETHERNET-EXT-MIB.
1.3.6.1.4.1.9.9.402.2.1.4CompliancecpeExtMIBCompliance4read-onlydeprecatedThe compliance statement for the CISCO-POWER-ETHERNET-EXT-MIB.
1.3.6.1.4.1.9.9.402.2.1.5CompliancecpeExtMIBCompliance5read-onlydeprecatedThe compliance statement for the CISCO-POWER-ETHERNET-EXT-MIB.
1.3.6.1.4.1.9.9.402.2.1.6CompliancecpeExtMIBCompliance6read-onlycurrentThe compliance statement for the CISCO-POWER-ETHERNET-EXT-MIB.
1.3.6.1.4.1.9.9.402.2.2NodecpeExtMIBGroups
1.3.6.1.4.1.9.9.402.2.2.1GroupcpeExtPsePortGroupcurrentThis group provides information and configuration objects in addition to those provided in the POWER-ETHERNET-MIB (RFC3621).
1.3.6.1.4.1.9.9.402.2.2.2GroupcpeExtPsePortGlobalConfigGroupcurrentThis is a collection of objects which provide global configuration of the PSE interfaces.
1.3.6.1.4.1.9.9.402.2.2.3GroupcpeExtPsePortPwrMonitorGroupcurrentThis is a collection of objects which provide power monitoring on PD's connected to the PSE interfaces.
1.3.6.1.4.1.9.9.402.2.2.4GroupcpeExtMainPseGroupdeprecatedThis is a collection of objects which provide additional information for the PSE group. cpeExtMainPseGroup object is superseded by cpeExtMainPseGroup2, and cpe…
1.3.6.1.4.1.9.9.402.2.2.5GroupcpeExtPortEntityIndexGroupcurrentThis is a collection of objects which provide entity physical index information for PSE port.
1.3.6.1.4.1.9.9.402.2.2.6GroupcpeExtPortPolicingGroupcurrentThis is a collection of objects which provide the hardware power consumption policing information for PSE port.
1.3.6.1.4.1.9.9.402.2.2.7GroupcpeExtPdStatsGroupcurrentThis is a collection of objects which provide the statistics information for powered devices.
1.3.6.1.4.1.9.9.402.2.2.8GroupcpeExtMainPseGroup2currentThis is a collection of objects which provide additional information to identify the PSE group.
1.3.6.1.4.1.9.9.402.2.2.9GroupcpeExtPseGrpPwrGroupcurrentThis is a collection of objects which provide power monitoring information for the PSE group.
1.3.6.1.4.1.9.9.402.2.2.10GroupcpeExtPortPolicingActionGroupcurrentThis is a collection of objects which provide control of the power policing action of the PSE port.
1.3.6.1.4.1.9.9.402.2.2.11GroupcpeExtPortPwrManAllocGroupcurrentThis is a collection of objects which provide manual power allocation for the PSE port.
1.3.6.1.4.1.9.9.402.2.2.12GroupcpeExtPolicingNotifEnableGroupcurrentA collection of object that provides control over power consumption policing status notification.
1.3.6.1.4.1.9.9.402.2.2.13GroupcpeExtPolicingNotifGroupcurrentThis is a collection of notifications related to power consumption policing information for PSE ports.
1.3.6.1.4.1.9.9.402.2.2.14GroupcpeExtPowerPriorityGroupcurrentA collection of objects which provides global control of power priority feature.
1.3.6.1.4.1.9.9.402.2.2.15GroupcpeExtPsePortLldpGroupcurrentA collection of objects which provides the information about the LLDP based Data Link Layer power classification characteristics of power Ethernet PSE ports.
1.3.6.1.4.1.9.9.402.2.2.16GroupcpeExtPsePortCapabilitiesGroupcurrentA collection of objects which provides PSE port capabilities.
1.3.6.1.4.1.9.9.402.2.2.17GroupcpeExtPsePortLldpPowerGroupcurrentA collection of objects which provide Power information via MDI TLV in LLDP Protocol.
1.3.6.1.4.1.9.9.402.2.2.18GroupcpeExtPseInfoPwrGroupcurrentThis is a collection of objects which provide used and remaining power information for the PSE group.
Type Definitions
NameSyntaxStatusDescription
CpeExtLldpPwrClassOrZeroINTEGER { unknown(0), class0(1), class1(2), class2(3), class3(4), class4(5) }currentThe power class of the PD or PSE port that implements the LLDP based Data Link Layer power classification 'unknown' - power classification of the powered devices is unknown. 'class0' - power classification of the powere…
CpeExtLldpPwrSrcINTEGER { pseAndLocal(1), local(2), pse(3), backupSrc(4), primarySrc(5), unknown(6) }currentThe power source of the PD or PSE port which implements the LLDP based Data Link Layer power classification. 'pseAndLocal' - A PD powered both locally and by a PSE. 'local' - A PD powered locally only. 'pse' - A PD powe…
CpeExtLldpPwrTypeINTEGER { type1Pd(1), type1Pse(2), type2Pd(3), type2Pse(4) }currentThe requested Data Terminal Equipment (DTE) Power via Media Dependent Interface (MDI) type based on Data Link Layer (DLL) power classification. In Data Link Layer power classification, the PSE and PD perform power negot…
CpeExtPwrPriorityINTEGER { critical(1), high(2), low(3), unknown(4) }currentThe power priority for the PD on the PSE port which implements the LLDP based Data Link Layer power classification. 'critical' - power priority is at critical level. 'high' - power priority is at high level. 'low' - pow…