CM-ALARM-MIB
100 objects
This module defines the Alarm Monitoring MIB definitions used by the F3 (FSP150CM/CC) product lines. Copyright (C) ADVA.
Imported Objects
| ADVA-MIB | fsp150cm TrapAlarmSeverity |
| CM-ENTITY-MIB | neIndex shelfIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | DateAndTime DisplayString TEXTUAL-CONVENTION TimeStamp TruthValue VariablePointer |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2544.1.12.6 | IdentitycmAlarmMIB | This module defines the Alarm Monitoring MIB definitions used by the F3 (FSP150CM/CC) product lines. Copyright (C) ADVA. | ||
| 1.3.6.1.4.1.2544.1.12.6.1 | NodealarmObjects | |||
| 1.3.6.1.4.1.2544.1.12.6.1.1 | NodecmAlarmScalars | |||
| 1.3.6.1.4.1.2544.1.12.6.1.1.1 | ScalarcmAlmLastChange | read-only | current | A snapshot of the value of sysUpTime when the alarm situation last changed on the node (ie. there was a raise or clear). This value is reset to zero when the a… |
| 1.3.6.1.4.1.2544.1.12.6.1.1.2 | ScalarcmAlmIndex | read-only | current | This value is assigned globally and sequentially to each new trap that is sent from the device. When this value reaches a maximum of 65535, it is wrapped to th… |
| 1.3.6.1.4.1.2544.1.12.6.1.1.3 | ScalarcmAlmTestAlarmEntity | read-write | current | This object is used to specify the entity for which the test alarm is raised/cleared. This entity can be OID of a card(unit) or a port (Ethernet Access or Ethe… |
| 1.3.6.1.4.1.2544.1.12.6.1.1.4 | ScalarcmAlmTestAlarmAction | read-write | current | This object can be used to raise/clear the testalarm on the entity specified by cmAlmTestAlarmEntity. |
| 1.3.6.1.4.1.2544.1.12.6.1.2 | TablecmSysAlmTable | not-accessible | current | A list of entries corresponding to the standing conditions that exist at the system level. Entries cannot be created in this table by management application ac… |
| 1.3.6.1.4.1.2544.1.12.6.1.2.1 | RowcmSysAlmEntry | not-accessible | current | An entry containing information applicable to a particular condition. |
| 1.3.6.1.4.1.2544.1.12.6.1.2.1.1 | ColumncmSysAlmNotifCode | read-only | current | This object identifies the severity of the condition. |
| 1.3.6.1.4.1.2544.1.12.6.1.2.1.2 | ColumncmSysAlmType | read-only | current | This object identifies the type of the condition. |
| 1.3.6.1.4.1.2544.1.12.6.1.2.1.3 | ColumncmSysAlmSrvEff | read-only | current | This object identifies whether the condition is service affecting or not. |
| 1.3.6.1.4.1.2544.1.12.6.1.2.1.4 | ColumncmSysAlmTime | read-only | current | This object contains the system time when the condition occurred. |
| 1.3.6.1.4.1.2544.1.12.6.1.2.1.5 | ColumncmSysAlmLocation | read-only | current | This object identifies the location of the condition. The value none(0) should be used if location is not applicable. |
| 1.3.6.1.4.1.2544.1.12.6.1.2.1.6 | ColumncmSysAlmDirection | read-only | current | This object identifies the direction of the condition. The value none(0) should be used if direction is not applicable. |
| 1.3.6.1.4.1.2544.1.12.6.1.2.1.7 | ColumncmSysAlmDescr | read-only | current | This object contains a text description of the condition. |
| 1.3.6.1.4.1.2544.1.12.6.1.2.1.8 | ColumncmSysAlmObject | read-only | current | OID of the actual object that raised the alarm. |
| 1.3.6.1.4.1.2544.1.12.6.1.2.1.9 | ColumncmSysAlmObjectName | read-only | current | Symbolic name of the managed object to which the condition pertains. |
| 1.3.6.1.4.1.2544.1.12.6.1.2.1.10 | ColumncmSysAlmAdditionalInfoObject | read-only | current | This object provides OID of associated entity that caused the alarm. If there is no associated entity, this value is 0.0. |
| 1.3.6.1.4.1.2544.1.12.6.1.2.1.11 | ColumncmSysAlmAdditionalInfoName | read-only | current | This object provides name of the associated entity to which the alarm pertains. If there is no such entity, this value is empty. |
| 1.3.6.1.4.1.2544.1.12.6.1.3 | TablecmSysCondTable | not-accessible | current | A list of entries corresponding to the standing conditions that exist at the system level. Entries cannot be created in this table by management application ac… |
| 1.3.6.1.4.1.2544.1.12.6.1.3.1 | RowcmSysCondEntry | not-accessible | current | An entry containing information applicable to a particular condition. |
| 1.3.6.1.4.1.2544.1.12.6.1.3.1.1 | ColumncmSysCondIndex | not-accessible | current | An integer index value used to uniquely identify a standing condition at the system level. |
| 1.3.6.1.4.1.2544.1.12.6.1.3.1.2 | ColumncmSysCondNotifCode | read-only | current | This object identifies the severity of the condition. |
| 1.3.6.1.4.1.2544.1.12.6.1.3.1.3 | ColumncmSysCondType | read-only | current | This object identifies the type of the condition. |
| 1.3.6.1.4.1.2544.1.12.6.1.3.1.4 | ColumncmSysCondSrvEff | read-only | current | This object identifies whether the condition is service affecting or not. |
| 1.3.6.1.4.1.2544.1.12.6.1.3.1.5 | ColumncmSysCondTime | read-only | current | This object contains the system time when the condition occurred. |
| 1.3.6.1.4.1.2544.1.12.6.1.3.1.6 | ColumncmSysCondLocation | read-only | current | This object identifies the location of the condition. The value none(0) should be used if location is not applicable. |
| 1.3.6.1.4.1.2544.1.12.6.1.3.1.7 | ColumncmSysCondDirection | read-only | current | This object identifies the direction of the condition. The value none(0) should be used if direction is not applicable. |
| 1.3.6.1.4.1.2544.1.12.6.1.3.1.8 | ColumncmSysCondDescr | read-only | current | This object contains a text description of the condition. |
| 1.3.6.1.4.1.2544.1.12.6.1.3.1.9 | ColumncmSysCondEffType | read-only | current | This object contains the condition effect type. |
| 1.3.6.1.4.1.2544.1.12.6.1.3.1.10 | ColumncmSysCondObject | read-only | current | OID of the actual object that raised the condition. |
| 1.3.6.1.4.1.2544.1.12.6.1.3.1.11 | ColumncmSysCondObjectName | read-only | current | Symbolic name of the managed object to which the condition pertains. |
| 1.3.6.1.4.1.2544.1.12.6.1.3.1.12 | ColumncmSysCondAdditionalInfoObject | read-only | current | This object provides OID of associated entity that caused the condition. If there is no associated entity, this value is 0.0. |
| 1.3.6.1.4.1.2544.1.12.6.1.3.1.13 | ColumncmSysCondAdditionalInfoName | read-only | current | This object provides name of the associated entity to which the condition pertains. If there is no such entity, this value is empty. |
| 1.3.6.1.4.1.2544.1.12.6.1.4 | TablecmNetworkElementAlmTable | not-accessible | current | A list of entries corresponding to the standing conditions that exist at the system level. Entries cannot be created in this table by management application ac… |
| 1.3.6.1.4.1.2544.1.12.6.1.4.1 | RowcmNetworkElementAlmEntry | not-accessible | current | An entry containing information applicable to a particular condition. |
| 1.3.6.1.4.1.2544.1.12.6.1.4.1.1 | ColumncmNetworkElementAlmNotifCode | read-only | current | This object identifies the severity of the condition. |
| 1.3.6.1.4.1.2544.1.12.6.1.4.1.2 | ColumncmNetworkElementAlmType | read-only | current | This object identifies the type of the condition. |
| 1.3.6.1.4.1.2544.1.12.6.1.4.1.3 | ColumncmNetworkElementAlmSrvEff | read-only | current | This object identifies whether the condition is service affecting or not. |
| 1.3.6.1.4.1.2544.1.12.6.1.4.1.4 | ColumncmNetworkElementAlmTime | read-only | current | This object contains the system time when the condition occurred. |
| 1.3.6.1.4.1.2544.1.12.6.1.4.1.5 | ColumncmNetworkElementAlmLocation | read-only | current | This object identifies the location of the condition. The value none(0) should be used if location is not applicable. |
| 1.3.6.1.4.1.2544.1.12.6.1.4.1.6 | ColumncmNetworkElementAlmDirection | read-only | current | This object identifies the direction of the condition. The value none(0) should be used if direction is not applicable. |
| 1.3.6.1.4.1.2544.1.12.6.1.4.1.7 | ColumncmNetworkElementAlmDescr | read-only | current | This object contains a text description of the condition. |
| 1.3.6.1.4.1.2544.1.12.6.1.4.1.8 | ColumncmNetworkElementAlmObject | read-only | current | OID of the actual object that raised the alarm. |
| 1.3.6.1.4.1.2544.1.12.6.1.4.1.9 | ColumncmNetworkElementAlmObjectName | read-only | current | Symbolic name of the managed object to which the condition pertains. This object can be any interface on this device or the system object. If this is an interf… |
| 1.3.6.1.4.1.2544.1.12.6.1.4.1.10 | ColumncmNetworkElementAlmAdditionalInfoObject | read-only | current | This object provides OID of associated entity that caused the alarm. If there is no associated entity, this value is 0.0. |
| 1.3.6.1.4.1.2544.1.12.6.1.4.1.11 | ColumncmNetworkElementAlmAdditionalInfoName | read-only | current | This object provides name of the associated entity to which the alarm pertains. If there is no such entity, this value is empty. |
| 1.3.6.1.4.1.2544.1.12.6.1.5 | TablecmNetworkElementCondTable | not-accessible | current | A list of entries corresponding to the standing conditions that exist at the system level. Entries cannot be created in this table by management application ac… |
| 1.3.6.1.4.1.2544.1.12.6.1.5.1 | RowcmNetworkElementCondEntry | not-accessible | current | An entry containing information applicable to a particular condition. |
| 1.3.6.1.4.1.2544.1.12.6.1.5.1.1 | ColumncmNetworkElementCondIndex | not-accessible | current | An integer index value used to uniquely identify a standing condition at a Network Element level. |
| 1.3.6.1.4.1.2544.1.12.6.1.5.1.2 | ColumncmNetworkElementCondNotifCode | read-only | current | This object identifies the severity of the condition. |
| 1.3.6.1.4.1.2544.1.12.6.1.5.1.3 | ColumncmNetworkElementCondType | read-only | current | This object identifies the type of the condition. |
| 1.3.6.1.4.1.2544.1.12.6.1.5.1.4 | ColumncmNetworkElementCondSrvEff | read-only | current | This object identifies whether the condition is service affecting or not. |
| 1.3.6.1.4.1.2544.1.12.6.1.5.1.5 | ColumncmNetworkElementCondTime | read-only | current | This object contains the system time when the condition occurred. |
| 1.3.6.1.4.1.2544.1.12.6.1.5.1.6 | ColumncmNetworkElementCondLocation | read-only | current | This object identifies the location of the condition. The value none(0) should be used if location is not applicable. |
| 1.3.6.1.4.1.2544.1.12.6.1.5.1.7 | ColumncmNetworkElementCondDirection | read-only | current | This object identifies the direction of the condition. The value none(0) should be used if direction is not applicable. |
| 1.3.6.1.4.1.2544.1.12.6.1.5.1.8 | ColumncmNetworkElementCondDescr | read-only | current | This object contains a text description of the condition. |
| 1.3.6.1.4.1.2544.1.12.6.1.5.1.9 | ColumncmNetworkElementCondObject | read-only | current | Symbolic name of the managed object to which the condition pertains. This object can be any interface on this device or the system object. If this is an interf… |
| 1.3.6.1.4.1.2544.1.12.6.1.5.1.10 | ColumncmNetworkElementCondObjectName | read-only | current | Symbolic name of the managed object to which the condition pertains. This object can be any interface on this device or the system object. If this is an interf… |
| 1.3.6.1.4.1.2544.1.12.6.1.5.1.11 | ColumncmNetworkElementCondEffType | read-only | current | This object contains the condition effect type. |
| 1.3.6.1.4.1.2544.1.12.6.1.5.1.12 | ColumncmNetworkElementCondAdditionalInfoObject | read-only | current | This object provides OID of associated entity that caused the alarm. If there is no associated entity, this value is 0.0. |
| 1.3.6.1.4.1.2544.1.12.6.1.5.1.13 | ColumncmNetworkElementCondAdditionalInfoName | read-only | current | This object provides name of the associated entity to which the alarm pertains. If there is no such entity, this value is empty. |
| 1.3.6.1.4.1.2544.1.12.6.1.6 | TablecmAlarmSeverityAssignmentTable | not-accessible | current | A list of configurable alarm severity assignment entries for Enterprise MIB Alarm Conditions. |
| 1.3.6.1.4.1.2544.1.12.6.1.6.1 | RowcmAlarmSeverityAssignmentEntry | not-accessible | current | A list of parameters that set up the alarm severity assignment profiles. |
| 1.3.6.1.4.1.2544.1.12.6.1.6.1.1 | ColumncmAlarmSeverityAssignmentEntityType | not-accessible | current | Alarm Severity Assignment Entity Type. |
| 1.3.6.1.4.1.2544.1.12.6.1.6.1.2 | ColumncmAlarmSeverityAssignmentCondType | not-accessible | current | This object identifies the type of the condition. |
| 1.3.6.1.4.1.2544.1.12.6.1.6.1.3 | ColumncmAlarmSeverityAssignmentSrvEff | not-accessible | current | This object identifies whether the condition is service affecting or not. |
| 1.3.6.1.4.1.2544.1.12.6.1.6.1.4 | ColumncmAlarmSeverityAssignmentLocation | read-only | current | This object identifies the location of the condition. The value none(0) is used if location is not applicable. |
| 1.3.6.1.4.1.2544.1.12.6.1.6.1.5 | ColumncmAlarmSeverityAssignmentNotifCode | read-write | current | This object allows configuration of the severity of the condition. |
| 1.3.6.1.4.1.2544.1.12.6.1.6.1.6 | ColumncmAlarmSeverityAssignmentDirection | read-only | current | This object identifies the direction of the condition. The value none(0) should be used if direction is not applicable. |
| 1.3.6.1.4.1.2544.1.12.6.1.7 | Tablef3EnvAlarmInputTable | not-accessible | current | A list of configurable Environmental Alarm Inputs. |
| 1.3.6.1.4.1.2544.1.12.6.1.7.1 | Rowf3EnvAlarmInputEntry | not-accessible | current | A list of parameters to manage the the environmental alarm inputs. |
| 1.3.6.1.4.1.2544.1.12.6.1.7.1.1 | Columnf3EnvAlarmInputIndex | not-accessible | current | Unique index for each environmental alarm input. |
| 1.3.6.1.4.1.2544.1.12.6.1.7.1.2 | Columnf3EnvAlarmInputDescr | read-write | current | This object allows SNMP management entities to provide description to the environmental alarm inputs. |
| 1.3.6.1.4.1.2544.1.12.6.1.7.1.3 | Columnf3EnvAlarmInputCondType | read-write | current | This object allows SNMP management entities to provide the environmental alarm condition associated with the environmental alarm input. |
| 1.3.6.1.4.1.2544.1.12.6.1.7.1.4 | Columnf3EnvAlarmInputNotifCode | read-write | current | This object allows SNMP management entities to provide the notification code for the environmental alarm input. |
| 1.3.6.1.4.1.2544.1.12.6.1.7.1.5 | Columnf3EnvAlarmInputMode | read-write | current | This object allows specification of the environmental alarm input mode. When 'disabled', environmental alarms are not raised. Value of 'alarmopen' allows alarm… |
| 1.3.6.1.4.1.2544.1.12.6.1.7.1.6 | Columnf3EnvAlarmInputAlmHoldOffEnabled | read-write | current | This object allows enabling/disabling of alarm hold off for this environmental alarm. When 'disabled', the standard alarm hold off (2.5seconds) does not hold, … |
| 1.3.6.1.4.1.2544.1.12.6.2 | NodealarmNotifications | |||
| 1.3.6.1.4.1.2544.1.12.6.2.1 | NotificationcmSysAlmTrap | current | This trap is sent each time an alarm condition is raised and inserted into to the cmSysAlmTable. It is also sent each time an alarm condition is cleared and re… | |
| 1.3.6.1.4.1.2544.1.12.6.2.2 | NotificationcmNetworkElementAlmTrap | current | This trap is sent each time an alarm condition is raised and inserted into to the cmNetworkElementAlmTable. It is also sent each time an alarm condition is cle… | |
| 1.3.6.1.4.1.2544.1.12.6.2.3 | NotificationcmSysEvent | current | This trap is sent each time an event condition is raised and inserted into to the cmSysCondTable. It is also sent each time an event condition is cleared and r… | |
| 1.3.6.1.4.1.2544.1.12.6.2.4 | NotificationcmNetworkElementEvent | current | This trap is sent each time an event condition is raised and inserted into to the cmNetworkElementCondTable. It is also sent each time an event condition is cl… | |
| 1.3.6.1.4.1.2544.1.12.6.3 | NodealarmConformance | |||
| 1.3.6.1.4.1.2544.1.12.6.3.1 | NodecmAlmCompliances | |||
| 1.3.6.1.4.1.2544.1.12.6.3.1.1 | CompliancecmAlmCompliance | current | Describes the requirements for conformance to the Alarm Condition Services. | |
| 1.3.6.1.4.1.2544.1.12.6.3.2 | NodecmAlmGroups | |||
| 1.3.6.1.4.1.2544.1.12.6.3.2.1 | GroupcmAlmObjectGroup | current | A collection of objects used to manage the Alarm conditions/threshold Services. | |
| 1.3.6.1.4.1.2544.1.12.6.3.2.2 | GroupcmAlmNotifGroup | current | A collection of notifications related to alarm conditions/threshold Services. | |
| 1.3.6.1.4.1.2544.1.12.6.3.2.3 | Groupf3EnvAlarmInputGroup | current | A collection of objects related to environmental alarm inputs. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| CmAlarmEntityType | INTEGER { system(1), hubshelf(2), cpmrshelf(3), eth-10-100-1000-ntucard(4), eth-cpmr-card(5), nemi-card(6), scu-card(7), fan(8), powersupply(9), accessport(10), networkport(11), oneru-ge101-shelf(12), oneru-ge206-shelf(13), eth-ge-101-card(14), eth-ge-206-card(15), cfmmep(16), sync(17), bitsinport(18), bitsoutport(19), cfmqosshaper(20), dcnport(21), oneru-ge201-shelf(22), eth-ge-201-card(23), oneru-ge201se-shelf(24), eth-ge-201se-card(25), oneru-ge206f-shelf(26), eth-ge-206f-card(27), lag(28), eth-1-10gcard(29), redundancygroup(30), protectiongroup(31), stucard(32), ethertrafficport(33), eth-10-gecard(34), swf-140gcard(35), aggregationshelf(36), sticard(37), amicard(38), usb3gmodem(39), oneru-ge112-shelf(40), eth-ge-112-card(41), oneru-ge114-shelf(42), eth-ge-114-card(43), oneru-ge206v-shelf(44), eth-ge-206v-card(45), ge-4e-cc(46), ge-4s-cc(47), oneru-xg210-shelf(48), eth-xg-210-card(49), xg-1x-cc(50), xg-1s-cc(51), scu-t-card(52), eth-10-100-1000-ntecard(53), slot(54), ocnstmport(55), e1t1port(56), stsvcpath(57), vtvcpath(58), vcg(59), e3t3port(60), vc4(61), vc3(62), vc12(63), sts3c(64), sts1(65), vt15(66), t3(67), e3(68), t1(69), e1(70), stm1-4-et(71), eotdmtrafficport(72), pwe3-ocnstm-card(73), pwe3-e1t1-card(74), satop(75), telecom-slave(76), sooc(77), eth-1-10ghcard(78), eth-10-gehcard(79), port-10mhz(80), ppsport(81), timeofdayport(82), oneru-t1804-shelf(83), eth-t1804-card(84), oneru-t3204-shelf(85), eth-t3204-card(86), eotdmnetworkport(87), oneru-syncprobe-shelf(88), eth-ge-syncprobe-card(89), sj-clockprobe(90), sj-ptpclockprobe(91), sj-ptpnetworkprobe(92), gps-receiverport(93), ampConfig(94), ge-8s-cc(95), oneru-ge114h-shelf(96), eth-ge-114h-card(97), oneru-ge114ph-shelf(98), eth-ge-114ph-card(99), psegroup(100), pseport(101), erpGroup(102), eth-fe-36e-card(103), mpflow(104), oneru-ge114sh-shelf(105), eth-ge-114sh-card(106), oneru-ge114s-shelf(107), eth-ge-114s-card(108), timeclock(109), satResponderSession(110), stu-h-card(111), sti-h-card(112), ge-8e-cc(113), oneru-otn210-shelf(114), eth-otn-210-card(115), ptpclock(116), ptpport(117), oneru-osa5411-shelf(118), eth-osa5411-card(119), oneru-ge112pro-shelf(120), eth-ge-112pro-card(121), oneru-ge112pro-m-shelf(122), eth-ge-112pro-m-card(123), oneru-ge114pro-shelf(124), eth-ge-114pro-card(125), oneru-ge114pro-c-shelf(126), eth-ge-114pro-c-card(127), oneru-ge114pro-sh-shelf(128), eth-ge-114pro-sh-card(129), oneru-ge114pro-csh-shelf(130), eth-ge-114pro-csh-card(131), connectGuardFlow(132), trafficIpIF(133), vrf(134), oneru-ge114pro-he-shelf(135), eth-ge-114pro-he-card(136), oneru-ge112pro-h-shelf(137), eth-ge-112pro-h-card(138), dhcpRelayAgent(139), oneru-xg210c-shelf(140), eth-xg-210c-card(141), ge-8sc-cc(142), oneru-osa5420-shelf(143), eth-osa5420-card(144), oneru-osa5421-shelf(145), eth-osa5421-card(146), mci(147), bits-x16(148), bfdSession(149), eomplsPw(150), oneru-ge114g-shelf(151), eth-ge-114g-card(152), wifidongleport(153), oneru-ge114proVm-h-shelf(154), eth-ge-114proVm-h-card(155), oneru-ge114proVm-ch-shelf(156), eth-ge-114proVm-ch-card(157), oneru-ge114proVm-csh-shelf(158), eth-ge-114proVm-csh-card(159), server-card(160), oneru-xg116pro-shelf(161), eth-xg-116pro-card(162), oneru-xg120pro-shelf(163), eth-xg-120pro-card(164), pps-x16(165), clk-x16(166), todandpps-x16(167), vxlanSegment(168), vtep(169), ge101pro-shelf(170), eth-ge-101pro-card(171), greTunnel(172), go102pro-s-shelf(173), go102pro-sp-shelf(174), onru-cx101pro-30a-shelf(175), onru-cx102pro-30a-shelf(176), eth-go102pro-s-card(177), eth-go102pro-sp-card(178), eth-cx101pro-30a-card(179), eth-cx102pro-30a-card(180), osa-ge-4s(181), elpgroup(182), oneru-ge112proVm-shelf(183), eth-ge-112proVm-card(184), hybrid-path-group(191), ge102pro-h-shelf(192), eth-ge-102pro-h-card(193), ge102pro-efmh-shelf(194), eth-ge-102pro-efmh-card(195), traffic-bgprouter-peer(196), traffic-ipv6-interface(197), oneru-xg116pro-h-shelf(198), eth-xg-116pro-h-card(199), go102pro-sm-shelf(200), eth-go102pro-sm-card(201), vrrp-router(202), ru1-osa5430-shelf(203), eth-csm-osa-card(204), ru3-osa5440-shelf(205), eth-osa5440-card(206), aux-osa(207), bits-x16-enhanced(208), osa-ge-4s-protected(209), syncprotectiongroup(210), timeclockprotectiongroup(211), mciprotectiongroup(212), oneru-xg118pro-sh-shelf(213), eth-xg-118pro-sh-card(214), ntp-clock(215), oneru-xg118proac-sh-shelf(216), eth-xg-118proac-sh-card(217), oneru-ge114proVm-sh-shelf(218), eth-ge-114proVm-sh-card(219), oneru-ge104-shelf(220), eth-ge-104-card(221), segment-routing(222), oneru-xg120pro-sh-shelf(223), eth-xg-120pro-sh-card(224), irig-card(225), irig-port-group(226), nci(227), ru1-osa5422-shelf(228), ru1-softsync-shelf(229), eth-osa5422-card(230), eth-softsync-card(231), mb-gnss-card(232), composite-clock-card(233), l3ptpport(234), ru1-osa5412-shelf(235), eth-osa5412-card(236), display-card(237), clk-x4-lpn-card(238), clk-x4-lpn-group(239), oneru-xg108-shelf(240), eth-xg-108-card(241), oneru-xg108-h-shelf(242), eth-xg-108-h-card(243), oneru-xg108-sh-shelf(244), eth-xg-108-sh-card(245) } | current | Identifies the type of alarm entity types. |
| CmCondEffectType | INTEGER { sc(1), tc(2), cl(3) } | current | Identifies the type of condition effect types. |
| CmConditionDescr | OCTET STRING (SIZE (1..64)) | current | A detailed text description of the condition or alarm being reported. This string may contain any printable ASCII character. |
| CmConditionType | INTEGER { none(0), acoopr(1), hwinitedsysboot(2), userinitednemireboot(3), userinitedsysboot(4), userinitedsysbootdefaultdb(5), userinitedsysbootdbrestore (6), userinitedsysrebootswact(7), sysrecoveryfailed(8), primntpsvrFailed(9), bckupntpsvrFailed(10), swdl-ftip(11), swdl-ftfail(12), swdl-ftpass(13), swdl-instip(14), swdl-instfail(15), swdl-instpass(16), swdl-actip(17), swdl-actfail(18), swdl-actpass(19), swdl-valip(20), swdl-valfail(21), swdl-valpass(22), db-ftip(23), db-ftfail(24), db-ftpass(25), ctneqpt(26), eqptflt(27), forced(28), lockout(29), manualswitch(30), wkswtopr(31), wkswbk(32), mismatch(33), psu1fail(34), psu2fail(35), eqptremoved(36), autonegunknown(37), dyinggasp(38), efmfail(39), efmrce(40), efmrld(41), efmrls(42), lnkdeactivated(43), lnkdownunisolated(44), lnkdowncablefault(45), lnkdowncableremoved(46), lnkdownautonegfailed(47), lnkdownlpbkfault(48), lnkdowncabletestfault(49), lnkdown(50), rfi(51), rxjabber(52), sfpmismatch(53), sfpremoved(54), sfptxfault(55), sfpinserted(56), fan-a(57), fan-b(58), overtemp(59), undertemp(60), overvoltage(61), undervoltage(62), shelfrmvd(63), rmtefmlpbkfail(64), inpwrflt(65), crossconnectccm(66), erroneousccm(67), someremotemepccm(68), somemacstatus(69), somerdi(70), ais(71), syncref(72), esmcfail(73), qlmismatch(74), freqoff(75), los(76), lof(77), qlsqlch(78), frngsync(79), fstsync(80), hldovrsync(81), losloc(82), wtr(83), allsyncref(84), qlinvalid(85), snmpdghostunresolved(86), snmpdghostresourcesbusy(87), bwexceedednegspeed(88), shaperbtd(89), sfpnonqualified(90), avghldovrfrqnotrdy(91), lnkdownmasterslavecfg(92), pwrnoinputunitfault(93), ipaddrconflict(94), nomoreresources(95), syncreflck(96), syncreffrc(97), syncrefman(98), syncrefwtr(99), syncrefsw(100), lcpfail(101), lcploopback(102), authservernotreachable (103), excessiveinterrupts(104), dbdowngradeip(105), testalarm(106), gen-filexfer-ip(107), gen-filexfer-fail(108), gen-filexfer-pass(109), gen-oper-ip(110), gen-oper-fail(111), gen-oper-pass(112), trafficfail(113), clockfail(114), rdncyswitchover(115), rdncyswvermismatch(116), rdncyoutofsync(117), rdncylockout(118), rdncymaintenance(119), xfptxfault(120), xfpmismatch(121), xfpnonqualified(122), xfpremoved(123), xfpinserted(124), lagmbrfail(125), swdl-proip(126), swdl-propass(127), swdl-profail(128), db-proip(129), db-propass(130), db-profail(131), swdl-rvtip(132), swdl-rvtpass(133), swdl-rvtfail(134), db-corruption(135), bpmismatch(136), popr-oovar(137), popr-oorange(138), popr-genfail(139), popr-sfpnqual(140), popr-rta(141), modemmea(142), modemnonqualified(143), modemremoved(144), nosimcard(145), env-genfail(146), env-misc(147), env-batterydischarge(148), env-batteryfail(149), env-coolingfanfail(150), env-enginefail(151), env-fusefail(152), env-hightemp(153), env-intrusion(154), env-lowbatteryvoltage(155), env-lowtemp(156), env-opendoor(157), env-powerfail(158), intctneqpt(159), syncnotready(160), vcgfail(161), loa(162), plct(163), tlct(164), plcr(165), tlcr(166), sqnc(167), ais-l(168), rfi-l(169), rei-l(170), exc-l(171), deg-l(172), tim-s(173), ais-p(174), lop-p(175), tim-p(176), uneq-p(177), plm-p(178), lom-p(179), exc-p(180), deg-p(181), rei-p(182), rfi-p(183), lcascrc(184), sqm(185), lom(186), gidmismatch(187), mnd(188), ais-v(189), lop-v(190), tim-v(191), uneq-v(192), plm-v(193), exc-v(194), deg-v(195), rei-v(196), rfi-v(197), rmtinitlpbk(198), rai(199), rei(200), idle(201), csf(202), gfplfd(203), gfpuplmismatch(204), gfpexhmismatch(205), vcat-lom(206), fragileecc(207), elmi-seqnummismatch(208), elmi-notoper(209), pw-rlofs(210), pw-lof(211), pw-latefrm(212), pw-jbovrn(213), allsoocsfailed(214), tsholdoverfrqnotready(215), tsfreerun(216), tsholdover(217), ptsflossofsync(218), ptsflossofannounce(219), ptsfunusable(220), unresolvedsatop(221), rdi-v(222), autonegBypass(223), forcedOffline(224), hwcfginconsistent(225), sjmtiemaskcross(226), sjoffsetfail(227), sjnotimelock(228), sjnofreqlock(229), sjmtiemargincross(230), sjtestreferencefail(231), sjtestsourcefail(232), sjtestnotimestamp(233), sjtestnomessages(234), gpsantennafail(235), ampNoPeer(236), ampProvFail(237), ampCfgFail(238), ltpFailure(239), ltpInprogress(240), pse-power-threshold-exceeded(241), pse-power-fail(242), pse-poweroff-overcurrent(243), pse-poweroff-overvoltage(244), pse-poweroff-overload(245), pse-poweroff-overtemp(246), pse-poweroff-short(247), erpFoPPM(248), erpFoPTO(249), erpBlockPort0RPL(250), erpBlockPort0SF(251), erpBlockPort0MS(252), erpBlockPort0FS(253), erpBlockPort0WTR(254), erpBlockPort1RPL(255), erpBlockPort1SF(256), erpBlockPort1MS(257), erpBlockPort1FS(258), erpBlockPort1WTR(259), ipv6addr-conflict(260), macAddrlearntblFull(261), timeClockNotLocked(262), timeNotTraceAble(263), timeFreqNotTraceAble(264), timeHoldOver(265), timeFreqLock(266), timeRefLock(267), timeRefUnavailable(268), timeRefDegraded(269), timeRefFrc(270), tsTimeFrun(271), tsTimeHoldOver(272), timeRefUnavailableWTR(273), timeRefDegradedWTR(274), rmtInitSat(275), lldpRemoteTblChg(276), soocLck(277), ampProvSuccess(278), ampCfgSuccess(279), soocSW(280), soocWTR(281), sjtealert(282), dataExportFtpFail(283), xfpWaveLengthMismatch(284), cpmrUpgrading(285), beaconLightFailure(286), manualSwitchClear(287), loopbackActive(288), loopbackRequest(289), trafficResourceLimitExceeded(290), oduAis(291), opuAis(292), otuAis(293), otnProtMsmtch(294), otnProtPrtclFail(295), oduBdi(296), otuBdi(297), lossCharSync(298), berHigh(299), laserFail(300), laserCurrentAbnormal(301), oduLock(302), autoShutdown(303), localFault(304), otuLof(305), otuLom(306), oduOci(307), opuPlm(308), oduSd(309), otuSd(310), opuSf(311), optPowerHighRx(312), optPowerLowRx(313), optPowerHighTx(314), optPowerLowTx(315), oduTim(316), otuTim(317), sjConstTeThrshld(318), sjInstTeThrshld(319), timeRefSW(320), aadcfailed(321), ptpfreqfrun(322), ptptimefrun(323), ptpfreqhldovr(324), ptptimehldovr(325), ptptimenottraceable(326), ptpfreqnottraceable(327), synctimeout(328), announcetimeout(329), delayresptimeout(330), multiplepeers(331), wrongdomain(332), nosatellitercv(333), trafficipifoutage(334), ptpportstatechanged(335), physicalSelfLpbk(336), cfCardRWFail(337), maxexpectedslaves(338), external-alarm(339), maskcrossed(340), oof(341), signalfail(342), timenottai(343), perffuncfailure(344), ptpportnotoper(345), leapsecondexpected(346), keyExchangeFail(347), keyExchangeAuthPasswordMissing(348), secureRamCleared(349), noRouteResources(350), tamperSwitchOpen(351), bfdSessionDown(352), destinationUnresolved(353), sjmaxtethrshld(354), trafficArpTableFull(355), erpRingSegmentation(356), gpsrcvrfail(357), noActiveRoute(358), vxlanDMac2DIPTableFull(359), bwExceedLagMemberPortSpeed(360), greRemoteUnreachable(361), bweexceedsportspeed(362), servicediscarded(363), bmcaError(364), freeze(365), gpsFwUpgrade(366), storageWearout(367), pps-not-generated(368), min-sat-1-thrshld-crossed(369), min-sat-2-thrshld-crossed(370), gatewayNotReachable(371), pdop-mask-cross(372), nc-initInProgress(373), primaryNtpSvr-auth-failed(374), backupNtpSvr-auth-failed(375), clock-class-mismatch(376), hpg-switch-force(377), hpg-switch-lockout(378), hpg-switch-to-3gpp-path(379), hpg-switch-to-fixed-path(380), bgp-linkdown(381), ospf-neighbour-lost(382), traffic-ndptable-full(383), dup-link-local-address(384), dup-unicast-address(385), ztp-failed(386), ztp-in-progress(387), nc-runningConfigLocked(388), pwrnoinput2(389), keyExchangeStopped(390), security-error(391), pppoe-connection-failed(392), no-ipv6route-resource(393), sfp-firmware-revision-mismatch(394), vrrp-new-master(395), nontpkeys(396), timesrcunavailable(397), syncsrcunavailable(398), local-cooling-fail(399), jamming(400), spoofing(401), httpsSslCertExpiryPending(402), httpsSslCertExpired(403), srgb-collision(404), sid-collision(405), sr-index-out-of-range(406), novalidsymkeybroadcast(407), patch-panel-mismatch(408), fan-fail(409), invalidsymkeypeering(410), auto-asymmetry-delay-fail(411), no-certificate(412), certificate-expired-soon(413), bpvc(414), crcf(415), oofc(416), psuinputfail1(417), psuinputfail2(418), time-clock-degraded-system-time(419), spoofing-pps(420), spoofing-loc(421), invalid-syscfg(422), incompatible-oscillator-type(423), fan-inactive(424), ps-inactive(425) } | current | Identifies the type of condition or alarm being reported. |
| CmDirection | INTEGER { none(0), bidirectional(1), bothDirections(2), notApplicable(3), receiveDirectionOnly(4), transmitDirectionOnly(5), uniDirectional(6) } | current | Specifies the direction associated with the particular information. |
| CmLocation | INTEGER { none(0), both(1), farEnd(2), nearEnd(3), notApplicable(4) } | current | Identifies the location associated with the particular information. |
| CmServiceEffect | INTEGER { none(0), nonServiceAffecting(1), serviceAffecting(2) } | current | Indicates whether a condition is service affecting or not. |
| EnvAlarmInputMode | INTEGER { disabled(1), alarmopen(2), alarmclosed(3) } | current | Identifies the environmental alarm input modes. |
| TestAlarmAction | INTEGER { not-applicable(0), raise(1), clear(2) } | current | Whether to raise/clear a test alarm. |