MIB Viewer

CM-PROTECTION-MIB

58 objects
This module defines the Protection MIB definitions used by the F3 (FSP150CM/CC) product lines. Copyright (C) ADVA Optical Networking.
Imported Objects
ADVA-MIBfsp150cm
CM-ENTITY-MIBneIndex shelfIndex slotIndex
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMIInteger32 MODULE-IDENTITY OBJECT-TYPE
SNMPv2-TCDisplayString MacAddress RowStatus StorageType TEXTUAL-CONVENTION TruthValue VariablePointer
OIDNameAccessStatusDescription
1.3.6.1.4.1.2544.1.12.7IdentitycmProtectionMIBThis module defines the Protection MIB definitions used by the F3 (FSP150CM/CC) product lines. Copyright (C) ADVA Optical Networking.
1.3.6.1.4.1.2544.1.12.7.1NodecmProtObjects
1.3.6.1.4.1.2544.1.12.7.1.1TablecmFacProtGroupTablenot-accessiblecurrentA list of entries corresponding to the Facility Protection Groups. Entries can be created/deleted in this table by management application action.
1.3.6.1.4.1.2544.1.12.7.1.1.1RowcmFacProtGroupEntrynot-accessiblecurrentAn entry containing information applicable to a particular Protection Group.
1.3.6.1.4.1.2544.1.12.7.1.1.1.1ColumncmFacProtGroupIndexread-onlycurrentUnique index value associated with the Facility Protection Group.
1.3.6.1.4.1.2544.1.12.7.1.1.1.2ColumncmFacProtGroupUserLabelread-createcurrentUser Label associated with the Facility Protection Group.
1.3.6.1.4.1.2544.1.12.7.1.1.1.3ColumncmFacProtGroupSwitchModeread-createcurrentFacility Protection Group's Protection Switch Mode.
1.3.6.1.4.1.2544.1.12.7.1.1.1.4ColumncmFacProtGroupRevertiveread-createcurrentWhether the Facility Protection is revertive or not. This object is not applicable for cmFacProtGroupSwitchMode 'dualactiverx'.
1.3.6.1.4.1.2544.1.12.7.1.1.1.5ColumncmFacProtGroupWaitToRestoreread-createcurrentTime in minutes to wait before reverting to Working facility in case of cmFacProtGroupRevertive set to revertive. This object is not applicable for cmFacProtGr…
1.3.6.1.4.1.2544.1.12.7.1.1.1.6ColumncmFacProtGroupDirectionread-createcurrentSupported Protection Group Switch direction. This object is not applicable for cmFacProtGroupSwitchMode 'dualactiverx'.
1.3.6.1.4.1.2544.1.12.7.1.1.1.7ColumncmFacProtGroupWorkPortread-createcurrentFacility Protection Group exists between 2 facilities (ports). This object represents the WORKING facility Port.
1.3.6.1.4.1.2544.1.12.7.1.1.1.8ColumncmFacProtGroupProtPortread-createcurrentThis object represents the PROTECT facility Network Element Port when cmFacProtGroupSwitchMode is oneplusone. In the case of dualactiverx, this represents the …
1.3.6.1.4.1.2544.1.12.7.1.1.1.9ColumncmFacProtGroupStatusread-onlycurrentThis object represents the PROTECTION group status.
1.3.6.1.4.1.2544.1.12.7.1.1.1.10ColumncmFacProtGroupActionread-writecurrentUser initiated protection switch action.
1.3.6.1.4.1.2544.1.12.7.1.1.1.11ColumncmFacProtGroupStorageTyperead-createcurrentThe type of storage configured for this entry.
1.3.6.1.4.1.2544.1.12.7.1.1.1.12ColumncmFacProtGroupRowStatusread-createcurrentThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description …
1.3.6.1.4.1.2544.1.12.7.1.1.1.13ColumncmFacProtGroupMacAddressread-onlycurrentThis object allows retrieval of the Mac Address of the PROTECTION group.
1.3.6.1.4.1.2544.1.12.7.1.2TablecmFacProtUnitTablenot-accessiblecurrentA list of entries corresponding to the Facility Protection Units.
1.3.6.1.4.1.2544.1.12.7.1.2.1RowcmFacProtUnitEntrynot-accessiblecurrentAn entry containing information applicable to a particular Protection Unit.
1.3.6.1.4.1.2544.1.12.7.1.2.1.1ColumncmFacProtUnitIndexread-onlycurrentUnique index value associated with the Facility Protection Unit.
1.3.6.1.4.1.2544.1.12.7.1.2.1.2ColumncmFacProtUnitTyperead-onlycurrentFacility Protection Unit's Type, i.e. whether working or protect.
1.3.6.1.4.1.2544.1.12.7.1.2.1.3ColumncmFacProtUnitStateread-onlycurrentFacility Protection Unit's State, i.e. whether active or standby.
1.3.6.1.4.1.2544.1.12.7.1.2.1.4ColumncmFacProtUnitPortread-onlycurrentFacility Protection Unit's points to a facility (port). This object represents the facility Network Element port.
1.3.6.1.4.1.2544.1.12.7.1.3TablecmMSPGroupTablenot-accessiblecurrentA list of entries corresponding to the Multiplex Section Protection Groups. Entries can be created/deleted in this table by management application action.
1.3.6.1.4.1.2544.1.12.7.1.3.1RowcmMSPGroupEntrynot-accessiblecurrentAn entry containing information applicable to a particular Protection Group.
1.3.6.1.4.1.2544.1.12.7.1.3.1.1ColumncmMSPGroupIndexread-onlycurrentUnique index value associated with the Multiplex Section Protection Group.
1.3.6.1.4.1.2544.1.12.7.1.3.1.2ColumncmMSPGroupUserLabelread-createcurrentUser Label associated with the Multiplex Section Protection Group.
1.3.6.1.4.1.2544.1.12.7.1.3.1.3ColumncmMSPGroupSwitchModeread-createcurrentMultiplex Section Protection Group's Protection Switch Mode.
1.3.6.1.4.1.2544.1.12.7.1.3.1.4ColumncmMSPGroupRevertiveread-createcurrentWhether the Multiplex Section Protection is revertive or not. This object is not applicable for cmMSPGroupSwitchMode 'dualactiverx'.
1.3.6.1.4.1.2544.1.12.7.1.3.1.5ColumncmMSPGroupWaitToRestoreread-createcurrentTime in minutes to wait before reverting to Working facility in case of cmMSPGroupRevertive set to revertive. This object is not applicable for cmMSPGroupSwitc…
1.3.6.1.4.1.2544.1.12.7.1.3.1.6ColumncmMSPGroupB2DEGTriggerread-createcurrentB2DEG is trigger of MSP or not.
1.3.6.1.4.1.2544.1.12.7.1.3.1.7ColumncmMSPGroupDirectionread-createcurrentSupported Protection Group Switch direction. This object is not applicable for cmMSPGroupSwitchMode 'dualactiverx'.
1.3.6.1.4.1.2544.1.12.7.1.3.1.8ColumncmMSPGroupWorkPortread-createcurrentMultiplex Section Protection Group exists between 2 facilities (ports). This object represents the WORKING facility Port.
1.3.6.1.4.1.2544.1.12.7.1.3.1.9ColumncmMSPGroupProtPortread-createcurrentThis object represents the PROTECT facility Network Element Port when cmMSPGroupSwitchMode is oneplusone. In the case of dualactiverx, this represents the seco…
1.3.6.1.4.1.2544.1.12.7.1.3.1.10ColumncmMSPGroupStatusread-onlycurrentThis object represents the PROTECTION group status.
1.3.6.1.4.1.2544.1.12.7.1.3.1.11ColumncmMSPGroupActionread-writecurrentUser initiated protection switch action.
1.3.6.1.4.1.2544.1.12.7.1.3.1.12ColumncmMSPGroupStorageTyperead-createcurrentThe type of storage configured for this entry.
1.3.6.1.4.1.2544.1.12.7.1.3.1.13ColumncmMSPGroupRowStatusread-createcurrentThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description …
1.3.6.1.4.1.2544.1.12.7.1.3.1.14ColumncmMSPGroupMacAddressread-onlycurrentThis object allows retrieval of the Mac Address of the PROTECTION group.
1.3.6.1.4.1.2544.1.12.7.1.4TablecmMSPUnitTablenot-accessiblecurrentA list of entries corresponding to the Multiplex Section Protection Units.
1.3.6.1.4.1.2544.1.12.7.1.4.1RowcmMSPUnitEntrynot-accessiblecurrentAn entry containing information applicable to a particular Protection Unit.
1.3.6.1.4.1.2544.1.12.7.1.4.1.1ColumncmMSPUnitIndexread-onlycurrentUnique index value associated with the Multiplex Section Protection Unit.
1.3.6.1.4.1.2544.1.12.7.1.4.1.2ColumncmMSPUnitTyperead-onlycurrentMultiplex Section Protection Unit's Type, i.e. whether working or protect.
1.3.6.1.4.1.2544.1.12.7.1.4.1.3ColumncmMSPUnitStateread-onlycurrentMultiplex Section Protection Unit's State, i.e. whether active or standby.
1.3.6.1.4.1.2544.1.12.7.1.4.1.4ColumncmMSPUnitPortread-onlycurrentFacility Protection Unit's points to a facility (port). This object represents the facility Network Element port.
1.3.6.1.4.1.2544.1.12.7.2NodecmProtNotifications
1.3.6.1.4.1.2544.1.12.7.3NodecmProtConformance
1.3.6.1.4.1.2544.1.12.7.3.1NodecmProtCompliances
1.3.6.1.4.1.2544.1.12.7.3.1.1CompliancecmProtCompliancecurrentDescribes the requirements for conformance to the CM Prot group.
1.3.6.1.4.1.2544.1.12.7.3.2NodecmProtGroups
1.3.6.1.4.1.2544.1.12.7.3.2.1GroupcmProtObjectGroupcurrentA collection of objects used to manage the Protection Object group.
1.3.6.1.4.1.2544.1.12.7.3.2.2GroupcmMSProtObjectGroupcurrentA collection of objects used to manage the Multiplex Section Protection Object group.
Type Definitions
NameSyntaxStatusDescription
CmProtGroupStatusINTEGER { nooutstandingreq (1), sf-protect (2), sf-working (3), sd-protect (4), sd-working (5), manual-protect (6), manual-working (7), forced-protect (8), forced-working (9), lockout-protect (10), waitToRestore (11) }currentEnumerations for Protection Status. nooutstandingreq - No oustanding request, sf-protect - Signal failure on protect, sf-working - Signal failure on working, sd-protect - Signal degrade on protect, sd-working - Signal d…
CmProtSwitchActionINTEGER { none (1), releaseprotswitch (2), manualfromworking (3), forcedfromworking (4), manualfromprotect (5), forcedfromprotect (6), lockoutfromprotect(7) }currentEnumerations for User initiated Protection Switch Action. manualfromworking - Manual Switch from Working, forcedfromworking - Forced Switch from Working, manualfromprotect - Manual Switch from Protect, forcedfromprotect…
CmProtSwitchDirectionINTEGER { unidirectional (1), bidirectional (2) }currentEnumerations for Protection Switch Direction. unidirectional - Unidirectional Protection Switching, bidirectional - Bidirectional Protection Switching.
CmProtSwitchModeINTEGER { oneplusone (1), dualactiverx(2), universalring(3) }currentEnumerations for Protection Switch Mode. oneplusone - 1+1, this is the NPCUP mode, dualactiverx - In this mode, traffic is bridged in A2N direction (same as 1+1), however both network ports receive customer traffic in N…
CmProtUnitStateINTEGER { active (1), standby (2) }currentEnumerations for Protection Unit State. active - Active Protection Unit, standby - Standby Protection Unit.
CmProtUnitTypeINTEGER { working (1), protect (2) }currentEnumerations for Protection Unit Type. working - Working Protection Unit, protect - Protect Protection Unit.