CPQHLTH-MIB
496 objects
No module-level DESCRIPTION found.
Imported Objects
| CPQHOST-MIB | compaq cpqHoGUIDCanonical cpqHoTrapFlags |
| CPQSINFO-MIB | cpqSiMemModuleSize cpqSiServerSystemId |
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | Counter enterprises |
| RFC1213-MIB | DisplayString sysName |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.232.6 | NodecpqHealth | |||
| 1.3.6.1.4.1.232.6.1 | NodecpqHeCorrectableMemoryError | A correctable memory error occurred. The error has been corrected. The current number of correctable memory errors is reported in the variable cpqHeCorrMemTota… | ||
| 1.3.6.1.4.1.232.6.1 | NodecpqHeMibRev | |||
| 1.3.6.1.4.1.232.6.1.1 | ScalarcpqHeMibRevMajor | read-only | mandatory | The Major Revision level of the MIB. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revis… |
| 1.3.6.1.4.1.232.6.1.2 | ScalarcpqHeMibRevMinor | read-only | mandatory | The minor revision level of the MIB. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing informati… |
| 1.3.6.1.4.1.232.6.1.3 | ScalarcpqHeMibCondition | read-only | mandatory | The overall condition. This object represents the overall status of the server health system represented by this MIB. |
| 1.3.6.1.4.1.232.6.2 | NodecpqHeComponent | |||
| 1.3.6.1.4.1.232.6.2 | NodecpqHeCorrectableMemoryLogDisabled | Correctable memory error tracking disabled. The frequency of errors is so high that the error tracking logic has been temporarily disabled. The cpqHeCorrMemLog… | ||
| 1.3.6.1.4.1.232.6.2.1 | NodecpqHeInterface | |||
| 1.3.6.1.4.1.232.6.2.1.1 | NodecpqHeOsNetWare3x | |||
| 1.3.6.1.4.1.232.6.2.1.1.1 | ScalarcpqHeNw3xDriverName | read-only | deprecated | Driver Name. This value identifies the NetWare Loadable Module providing the operating system access to the Server Health information. |
| 1.3.6.1.4.1.232.6.2.1.1.2 | ScalarcpqHeNw3xDriverDate | read-only | deprecated | Driver Date. The date of the NetWare Loadable Module providing the operating system access to the Server Health logs. The date is provided in mm/dd/yy format. |
| 1.3.6.1.4.1.232.6.2.1.1.3 | ScalarcpqHeNw3xDriverVersion | read-only | deprecated | Driver Version. This is the version of the NetWare Loadable Module (NLM) providing the operating system access to the Server Health logs. |
| 1.3.6.1.4.1.232.6.2.1.4 | NodecpqHeOsCommon | |||
| 1.3.6.1.4.1.232.6.2.1.4.1 | ScalarcpqHeOsCommonPollFreq | read-write | mandatory | The Insight Agent's polling frequency. The frequency, in seconds, at which the Insight Agent requests information from the device driver. A frequency of zero i… |
| 1.3.6.1.4.1.232.6.2.1.4.2 | TablecpqHeOsCommonModuleTable | not-accessible | deprecated | Supporting software table. This is a table of software modules that provide an interface to the device this server health MIB describes. |
| 1.3.6.1.4.1.232.6.2.1.4.2.1 | RowcpqHeOsCommonModuleEntry | not-accessible | deprecated | A description of a software modules that provide an interface to the device this MIB describes. |
| 1.3.6.1.4.1.232.6.2.1.4.2.1.1 | ColumncpqHeOsCommonModuleIndex | read-only | deprecated | A unique index for this module description. |
| 1.3.6.1.4.1.232.6.2.1.4.2.1.2 | ColumncpqHeOsCommonModuleName | read-only | deprecated | The module name. |
| 1.3.6.1.4.1.232.6.2.1.4.2.1.3 | ColumncpqHeOsCommonModuleVersion | read-only | deprecated | The module version in XX.YY format. Where XX is the major version number and YY is the minor version number. This field will be null (size 0) string if the age… |
| 1.3.6.1.4.1.232.6.2.1.4.2.1.4 | ColumncpqHeOsCommonModuleDate | read-only | deprecated | The module date. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 s… |
| 1.3.6.1.4.1.232.6.2.1.4.2.1.5 | ColumncpqHeOsCommonModulePurpose | read-only | deprecated | The purpose of the module described in this entry. |
| 1.3.6.1.4.1.232.6.2.2 | NodecpqHeCriticalError | |||
| 1.3.6.1.4.1.232.6.2.2.1 | ScalarcpqHeCritLogSupported | read-only | mandatory | This value specifies if this system supports the critical error logging feature. |
| 1.3.6.1.4.1.232.6.2.2.2 | ScalarcpqHeCritLogCondition | read-only | mandatory | This value specifies the overall condition of the critical error log feature. |
| 1.3.6.1.4.1.232.6.2.2.3 | ScalarcpqHeLastCritErrorAbendMsg | read-only | mandatory | Last Critical Termination message. The message associated with the last critical error of type criticalException(14) or abend(27). |
| 1.3.6.1.4.1.232.6.2.2.4 | TablecpqHeCriticalErrorTable | not-accessible | mandatory | A table of critical error descriptions. |
| 1.3.6.1.4.1.232.6.2.2.4.1 | RowcpqHeCriticalErrorEntry | not-accessible | mandatory | A critical error description. |
| 1.3.6.1.4.1.232.6.2.2.4.1.1 | ColumncpqHeCriticalErrorIndex | read-only | mandatory | A number that uniquely specifies this critical error description. The entries will be in order of occurrence with the most recent entry first. |
| 1.3.6.1.4.1.232.6.2.2.4.1.2 | ColumncpqHeCriticalErrorStatus | read-write | mandatory | This value specifies if the user has marked this error as corrected. Marking errors as corrected may be performed with the Diagnostics or by a set operation on… |
| 1.3.6.1.4.1.232.6.2.2.4.1.3 | ColumncpqHeCriticalErrorType | read-only | mandatory | This value specifies the type of error. |
| 1.3.6.1.4.1.232.6.2.2.4.1.4 | ColumncpqHeCriticalErrorTime | read-only | mandatory | The time of the error: hour (first five bits), day of month (next 5 bits), month (next 4 bits), year of the current century (next 7 bits). The last 3 bits are … |
| 1.3.6.1.4.1.232.6.2.2.4.1.5 | ColumncpqHeCriticalErrorInfo | read-only | mandatory | Information about the error. |
| 1.3.6.1.4.1.232.6.2.2.4.1.6 | ColumncpqHeCriticalErrorDesc | read-only | mandatory | A text description of the critical error. |
| 1.3.6.1.4.1.232.6.2.3 | NodecpqHeCorrectableMemory | |||
| 1.3.6.1.4.1.232.6.2.3.1 | ScalarcpqHeCorrMemLogStatus | read-only | mandatory | This value specifies whether this system is currently tracking correctable memory errors. |
| 1.3.6.1.4.1.232.6.2.3.2 | ScalarcpqHeCorrMemLogCondition | read-only | mandatory | This value specifies the overall condition of the correctable memory error log feature. |
| 1.3.6.1.4.1.232.6.2.3.3 | ScalarcpqHeCorrMemTotalErrs | read-only | deprecated | The number of correctable memory errors that have occurred. |
| 1.3.6.1.4.1.232.6.2.3.4 | TablecpqHeCorrMemErrTable | not-accessible | mandatory | A table of correctable memory error descriptions. |
| 1.3.6.1.4.1.232.6.2.3.4.1 | RowcpqHeCorrMemErrEntry | not-accessible | mandatory | A correctable memory error description. |
| 1.3.6.1.4.1.232.6.2.3.4.1.1 | ColumncpqHeCorrMemErrIndex | read-only | mandatory | A number that uniquely specifies this correctable memory error description. The entries will be in order of occurrence with the most recent new entry first. |
| 1.3.6.1.4.1.232.6.2.3.4.1.2 | ColumncpqHeCorrMemErrCount | read-write | mandatory | The number of times this memory location has had a correctable memory error. The value zero (0) indicates that the user has marked this error as corrected. Mar… |
| 1.3.6.1.4.1.232.6.2.3.4.1.3 | ColumncpqHeCorrMemErrTime | read-only | mandatory | The time of the error: hour (first five bits), day of month (next 5 bits), month (next 4 bits), year of the current century (next 7 bits). The last 3 bits are … |
| 1.3.6.1.4.1.232.6.2.3.4.1.4 | ColumncpqHeCorrMemErrDdr | read-only | mandatory | The data destination register value. This contains information about the memory bank in which the error occurred. The interpretation of this value is dependent… |
| 1.3.6.1.4.1.232.6.2.3.4.1.5 | ColumncpqHeCorrMemErrSyndrome | read-only | mandatory | The memory syndrome value. This contains information about the memory module in which the error occurred. The interpretation of this value is dependant on the … |
| 1.3.6.1.4.1.232.6.2.3.4.1.6 | ColumncpqHeCorrMemErrDesc | read-only | mandatory | A text description of the correctable memory error. |
| 1.3.6.1.4.1.232.6.2.3.4.1.7 | ColumncpqHeCorrMemErrHwLocation | read-only | optional | A text description of the hardware location, on complex multi SBB hardware only, for the correctable memory error. A NULL string indicates that the hardware lo… |
| 1.3.6.1.4.1.232.6.2.3.5 | ScalarcpqHeCorrMemErrorCntThresh | read-only | mandatory | The error threshold for Correctable memory errors. When cpqHeCorrMemErrCount is greater than or equal to this value user action is required to replace the fail… |
| 1.3.6.1.4.1.232.6.2.5 | NodecpqHeAsr | |||
| 1.3.6.1.4.1.232.6.2.5.1 | ScalarcpqHeAsrStatus | read-write | mandatory | The Automatic Server Recovery feature status. If this object is currently other(1) or notAvailable(2) all set operations will fail. Any attempt to set this obj… |
| 1.3.6.1.4.1.232.6.2.5.2 | ScalarcpqHeAsrMajorVersion | read-only | mandatory | The major version number of the Automatic Server Recovery feature hardware. |
| 1.3.6.1.4.1.232.6.2.5.3 | ScalarcpqHeAsrMinorVersion | read-only | mandatory | The minor version number of the Automatic Server Recovery feature hardware. |
| 1.3.6.1.4.1.232.6.2.5.4 | ScalarcpqHeAsrTimeout | read-write | mandatory | The time-out in minutes for the Automatic Server Recovery feature hardware. If the variable is not supported, a value of -1 will be returned. |
| 1.3.6.1.4.1.232.6.2.5.5 | ScalarcpqHeAsrBaseIo | read-only | mandatory | The Automatic Server Recovery feature Base I/O address. |
| 1.3.6.1.4.1.232.6.2.5.6 | ScalarcpqHeAsrPost | read-only | deprecated | Indicates if the Automatic Server Recovery timer passed the server power-on self test. |
| 1.3.6.1.4.1.232.6.2.5.7 | ScalarcpqHeAsrReset | read-write | mandatory | Indicates if the previous reset was caused by the ASR timer. An asrReset(3) condition may be changed with a viewed-asrReset(4) set operation. This is only vali… |
| 1.3.6.1.4.1.232.6.2.5.8 | ScalarcpqHeAsrReboot | read-write | mandatory | Indicates what software should be started when the server is rebooted by the ASR feature. If this object is currently set to other(1), set operations will fail… |
| 1.3.6.1.4.1.232.6.2.5.9 | ScalarcpqHeAsrRebootLimit | read-write | mandatory | The number of ASR timer reboots that should cause the server to boot the firmware console and override the standard reboot setting (cpqHeAsrReboot). If this va… |
| 1.3.6.1.4.1.232.6.2.5.10 | ScalarcpqHeAsrRebootCount | read-write | mandatory | The number of ASR reboots that have occurred on this server since the last manual reboot. Reboot count may be reset with a zero valued set operation on this va… |
| 1.3.6.1.4.1.232.6.2.5.11 | ScalarcpqHeAsrPagerStatus | read-write | mandatory | The status of the ASR pager feature. If the current value of this object is not other(1), it may be set to disabled(2) or enabled(3). Attempting a set operatio… |
| 1.3.6.1.4.1.232.6.2.5.12 | ScalarcpqHeAsrPagerNumber | read-write | mandatory | The pager number to be dialed after an ASR reboot. |
| 1.3.6.1.4.1.232.6.2.5.13 | ScalarcpqHeAsrCommPort | read-write | mandatory | The communication port to be used by the firmware pager and console. The value zero (0) indicates this setting is undefined. If the current value of this objec… |
| 1.3.6.1.4.1.232.6.2.5.14 | ScalarcpqHeAsrBaudRate | read-only | mandatory | The baud rate to be used by the firmware pager and console. The value zero (0) indicates this setting is undefined. If the variable is not supported, a value o… |
| 1.3.6.1.4.1.232.6.2.5.15 | ScalarcpqHeAsrPagerMessage | read-write | mandatory | The 8 character pager message entered by the user. |
| 1.3.6.1.4.1.232.6.2.5.16 | ScalarcpqHeAsrBootFail | read-only | deprecated | The action to be taken if an ASR reboot failure occurs. |
| 1.3.6.1.4.1.232.6.2.5.17 | ScalarcpqHeAsrCondition | read-only | mandatory | This value specifies the overall condition of the ASR feature. |
| 1.3.6.1.4.1.232.6.2.5.18 | ScalarcpqHeAsrDialInStatus | read-write | mandatory | The status of the ASR dial in feature. If the current value of this object is other(1) any attempt to set this object from a management station will fail. Any … |
| 1.3.6.1.4.1.232.6.2.5.19 | ScalarcpqHeAsrDialOutStatus | read-write | mandatory | The status of the ASR dial out feature. If the current value of this object is other(1) any attempt to set this object from a management station will fail. Any… |
| 1.3.6.1.4.1.232.6.2.5.20 | ScalarcpqHeAsrDialOutNumber | read-write | mandatory | The phone number to be dialed for remote diagnostics if an ASR reset occurs. |
| 1.3.6.1.4.1.232.6.2.5.21 | ScalarcpqHeAsrNetworkAccessStatus | read-write | mandatory | The status of the ASR network access feature. If the current value of this object is other(1) any attempt to set this object from a management station will fai… |
| 1.3.6.1.4.1.232.6.2.5.22 | ScalarcpqHeAsrPollTime | read-write | optional | The poll time in seconds the ASR watchdog timer is being refreshed periodically. |
| 1.3.6.1.4.1.232.6.2.6 | NodecpqHeThermal | |||
| 1.3.6.1.4.1.232.6.2.6.1 | ScalarcpqHeThermalCondition | read-only | mandatory | This value specifies the overall condition of the system's thermal environment. |
| 1.3.6.1.4.1.232.6.2.6.2 | ScalarcpqHeThermalDegradedAction | read-write | mandatory | The action to perform when the thermal condition is degraded. This value will be one of the following: other(1) This feature is not supported by this system or… |
| 1.3.6.1.4.1.232.6.2.6.3 | ScalarcpqHeThermalTempStatus | read-only | mandatory | The status of the system's temperature sensors: This value will be one of the following: other(1) Temp sensing is not supported by this system or driver. ok(2)… |
| 1.3.6.1.4.1.232.6.2.6.4 | ScalarcpqHeThermalSystemFanStatus | read-only | mandatory | The status of the fan(s) in the system. This value will be one of the following: other(1) Fan status detection is not supported by this system or driver. ok(2)… |
| 1.3.6.1.4.1.232.6.2.6.5 | ScalarcpqHeThermalCpuFanStatus | read-only | mandatory | The status of the processor fan(s) in the system. This value will be one of the following: other(1) Fan status detection is not supported by this system or dri… |
| 1.3.6.1.4.1.232.6.2.6.6 | TablecpqHeThermalFanTable | not-accessible | mandatory | A table of fan descriptions. |
| 1.3.6.1.4.1.232.6.2.6.6.1 | RowcpqHeThermalFanEntry | not-accessible | mandatory | A fan description. |
| 1.3.6.1.4.1.232.6.2.6.6.1.1 | ColumncpqHeThermalFanIndex | read-only | mandatory | A number that uniquely specifies this fan description. |
| 1.3.6.1.4.1.232.6.2.6.6.1.2 | ColumncpqHeThermalFanRequired | read-only | mandatory | This specifies if the fan described is required for proper operation of the system. |
| 1.3.6.1.4.1.232.6.2.6.6.1.3 | ColumncpqHeThermalFanPresent | read-only | mandatory | This specifies if the fan described is present in the system. |
| 1.3.6.1.4.1.232.6.2.6.6.1.4 | ColumncpqHeThermalFanCpuFan | read-only | mandatory | This specifies if the described fan is intended specifically to cool the CPU(s). |
| 1.3.6.1.4.1.232.6.2.6.6.1.5 | ColumncpqHeThermalFanStatus | read-only | mandatory | This specifies if the fan described is operating properly. This value will be one of the following: other(1) Fan status detection is not supported by this syst… |
| 1.3.6.1.4.1.232.6.2.6.6.1.6 | ColumncpqHeThermalFanHwLocation | read-only | optional | A text description of the hardware location, on complex multi SBB hardware only, for the fan. A NULL string indicates that the hardware location could not be d… |
| 1.3.6.1.4.1.232.6.2.6.6.1.7 | ColumncpqHeThermalFanCurrentSpeed | read-only | optional | The current speed of a fan in rpm - revolutions per minute. |
| 1.3.6.1.4.1.232.6.2.6.7 | TablecpqHeFltTolFanTable | not-accessible | mandatory | A table of Fault Tolerant Fan Entries. |
| 1.3.6.1.4.1.232.6.2.6.7.1 | RowcpqHeFltTolFanEntry | not-accessible | mandatory | A Fault Tolerant Fan Entry. |
| 1.3.6.1.4.1.232.6.2.6.7.1.1 | ColumncpqHeFltTolFanChassis | read-only | mandatory | The System Chassis number. |
| 1.3.6.1.4.1.232.6.2.6.7.1.2 | ColumncpqHeFltTolFanIndex | read-only | mandatory | A number that uniquely specifies this fan description. |
| 1.3.6.1.4.1.232.6.2.6.7.1.3 | ColumncpqHeFltTolFanLocale | read-only | mandatory | This specifies the location of the fan in the system. |
| 1.3.6.1.4.1.232.6.2.6.7.1.4 | ColumncpqHeFltTolFanPresent | read-only | mandatory | This specifies if the fan described is present in the system. |
| 1.3.6.1.4.1.232.6.2.6.7.1.5 | ColumncpqHeFltTolFanType | read-only | mandatory | This specifies the type of fan. other(1) The type of fan could not be determined. tachOutput(2) The fan can increase speed for greater cooling. Implies spin de… |
| 1.3.6.1.4.1.232.6.2.6.7.1.6 | ColumncpqHeFltTolFanSpeed | read-only | mandatory | This specifies the speed of the fan. This value will be set if the fan type is tachOutput. |
| 1.3.6.1.4.1.232.6.2.6.7.1.7 | ColumncpqHeFltTolFanRedundant | read-only | mandatory | This specifies if the fan is in a redundant configuration. |
| 1.3.6.1.4.1.232.6.2.6.7.1.8 | ColumncpqHeFltTolFanRedundantPartner | read-only | mandatory | This specifies the index of the redundant partner. A value of zero will be used if there is no redundant partner. |
| 1.3.6.1.4.1.232.6.2.6.7.1.9 | ColumncpqHeFltTolFanCondition | read-only | mandatory | The condition of the fan. This value will be one of the following: other(1) Fan status detection is not supported by this system or driver. ok(2) The fan is op… |
| 1.3.6.1.4.1.232.6.2.6.7.1.10 | ColumncpqHeFltTolFanHotPlug | read-only | mandatory | This indicates if the fan is capable of being removed and/or inserted while the system is in an operational state. If the value is hotPluggable(3), the fan can… |
| 1.3.6.1.4.1.232.6.2.6.7.1.11 | ColumncpqHeFltTolFanHwLocation | read-only | optional | A text description of the hardware location, on complex multi SBB hardware only, for the fan. A NULL string indicates that the hardware location could not be d… |
| 1.3.6.1.4.1.232.6.2.6.7.1.12 | ColumncpqHeFltTolFanCurrentSpeed | read-only | optional | The current speed of a fan in rpm - revolutions per minute. |
| 1.3.6.1.4.1.232.6.2.6.8 | TablecpqHeTemperatureTable | not-accessible | mandatory | A table of Temperature Sensor Entries. |
| 1.3.6.1.4.1.232.6.2.6.8.1 | RowcpqHeTemperatureEntry | not-accessible | mandatory | A Temperature Sensor Entry. |
| 1.3.6.1.4.1.232.6.2.6.8.1.1 | ColumncpqHeTemperatureChassis | read-only | mandatory | The System Chassis number. |
| 1.3.6.1.4.1.232.6.2.6.8.1.2 | ColumncpqHeTemperatureIndex | read-only | mandatory | A number that uniquely specifies this temperature sensor description. |
| 1.3.6.1.4.1.232.6.2.6.8.1.3 | ColumncpqHeTemperatureLocale | read-only | mandatory | This specifies the location of the temperature sensor present in the system. |
| 1.3.6.1.4.1.232.6.2.6.8.1.4 | ColumncpqHeTemperatureCelsius | read-only | mandatory | This is the current temperature sensor reading in degrees celsius. If this value cannot be determined by software, then a value of -99 will be returned. |
| 1.3.6.1.4.1.232.6.2.6.8.1.5 | ColumncpqHeTemperatureThreshold | read-write | mandatory | This is the shutdown threshold temperature sensor setting in degrees celsius. This is the temperature in which the sensor will be considered to be in a failed … |
| 1.3.6.1.4.1.232.6.2.6.8.1.6 | ColumncpqHeTemperatureCondition | read-only | mandatory | The Temperature sensor condition. This value will be one of the following: other(1) Temperature could not be determined. ok(2) The temperature sensor is within… |
| 1.3.6.1.4.1.232.6.2.6.8.1.7 | ColumncpqHeTemperatureThresholdType | read-only | mandatory | This specifies the type of this instance of temperature sensor. This value will be one of the following: other(1) Temperature threshold type could not be deter… |
| 1.3.6.1.4.1.232.6.2.6.8.1.8 | ColumncpqHeTemperatureHwLocation | read-only | optional | A text description of the hardware location, on complex multi SBB hardware only, for the temperature sensor. A NULL string indicates that the hardware location… |
| 1.3.6.1.4.1.232.6.2.6.9 | TablecpqHeCoolingModuleTable | not-accessible | mandatory | A table of Fault Tolerant Cooling Module Entries. |
| 1.3.6.1.4.1.232.6.2.6.9.1 | RowcpqHeCoolingModuleEntry | not-accessible | mandatory | A Fault Tolerant Cooling Module Entry. |
| 1.3.6.1.4.1.232.6.2.6.9.1.1 | ColumncpqHeCoolingModuleChassis | read-only | mandatory | The Cooling Module chassis number. |
| 1.3.6.1.4.1.232.6.2.6.9.1.2 | ColumncpqHeCoolingModuleIndex | read-only | mandatory | A number that uniquely specifies this Cooling Module description. |
| 1.3.6.1.4.1.232.6.2.6.9.1.3 | ColumncpqHeCoolingModuleLocale | read-only | mandatory | This specifies the location of the Cooling Module in the system. |
| 1.3.6.1.4.1.232.6.2.6.9.1.4 | ColumncpqHeCoolingModulePresent | read-only | mandatory | This specifies if the Cooling module described is present in the system. |
| 1.3.6.1.4.1.232.6.2.6.9.1.5 | ColumncpqHeCoolingModuleType | read-only | mandatory | This specifies the type of Cooling. other(1) The type of Cooling Module could not be determined. liquidCooling(2) The type of the Cooling Module is Liquid Cool… |
| 1.3.6.1.4.1.232.6.2.6.9.1.6 | ColumncpqHeCoolingModuleSpeed | read-only | mandatory | This specifies the speed of the Cooling Module. |
| 1.3.6.1.4.1.232.6.2.6.9.1.7 | ColumncpqHeCoolingModuleRedundant | read-only | mandatory | This specifies if the Cooling Module is in a redundant configuration. |
| 1.3.6.1.4.1.232.6.2.6.9.1.8 | ColumncpqHeCoolingModuleRedundantPartner | read-only | mandatory | This specifies the index of the redundant partner. A value of zero will be used if there is no redundant partner. |
| 1.3.6.1.4.1.232.6.2.6.9.1.9 | ColumncpqHeCoolingModuleCondition | read-only | mandatory | The condition of the Cooling Module. This value will be one of the following: other(1) Cooling status detection is not supported by this system or driver. ok(2… |
| 1.3.6.1.4.1.232.6.2.6.9.1.10 | ColumncpqHeCoolingModuleHotPlug | read-only | mandatory | This indicates if the Cooling Module is capable of being removed and/or inserted while the system is in an operational state. If the value is hotPluggable(3), … |
| 1.3.6.1.4.1.232.6.2.6.9.1.11 | ColumncpqHeCoolingModuleHwLocation | read-only | optional | A text description of the hardware location for the Cooling Modules. A NULL string indicates that the hardware location could not be determined or is irrelevan… |
| 1.3.6.1.4.1.232.6.2.6.9.1.12 | ColumncpqHeCoolingModuleCurrentSpeed | read-only | optional | The current speed of a Cooling Module in rpm - revolutions per minute. |
| 1.3.6.1.4.1.232.6.2.7 | NodecpqHePostMsg | |||
| 1.3.6.1.4.1.232.6.2.7.1 | ScalarcpqHePostMsgCondition | read-only | mandatory | This value specifies the overall condition of the POST error recording feature. |
| 1.3.6.1.4.1.232.6.2.7.2 | TablecpqHePostMsgTable | not-accessible | mandatory | A table of POST error message numbers. |
| 1.3.6.1.4.1.232.6.2.7.2.1 | RowcpqHePostMsgEntry | not-accessible | mandatory | A POST error message number. |
| 1.3.6.1.4.1.232.6.2.7.2.1.1 | ColumncpqHePostMsgIndex | read-only | mandatory | A number that uniquely specifies this POST error description. |
| 1.3.6.1.4.1.232.6.2.7.2.1.2 | ColumncpqHePostMsgCode | read-only | mandatory | This specifies POST message number for this error. |
| 1.3.6.1.4.1.232.6.2.7.2.1.3 | ColumncpqHePostMsgDesc | read-only | mandatory | This contains a text description of the POST error. A string of length zero (0) will be returned if no description is available. |
| 1.3.6.1.4.1.232.6.2.7.3 | ScalarcpqHePostMsgEv | read-write | mandatory | The EV used to store 8 non-critical POST error codes for use with Quicktest, Utilities, and CIM. Setting this variable with a zero length octet string will cle… |
| 1.3.6.1.4.1.232.6.2.8 | NodecpqHeSysUtil | |||
| 1.3.6.1.4.1.232.6.2.8.1 | ScalarcpqHeSysUtilLifeTime | read-only | mandatory | The total time (in minutes) the system has been in full operation (while the server health supporting software was running). |
| 1.3.6.1.4.1.232.6.2.8.2 | ScalarcpqHeSysUtilEisaBusMin | read-only | mandatory | The EISA bus utilization as a percentage of the theoretical maximum during the last minute. A value of -1 indicates that this feature is not supported on this … |
| 1.3.6.1.4.1.232.6.2.8.3 | ScalarcpqHeSysUtilEisaBusFiveMin | read-only | mandatory | The EISA bus utilization as a percentage of the theoretical maximum during the last five minutes. A value of -1 indicates that this feature is not supported on… |
| 1.3.6.1.4.1.232.6.2.8.4 | ScalarcpqHeSysUtilEisaBusThirtyMin | read-only | mandatory | The EISA bus utilization as a percentage of the theoretical maximum during the last thirty minutes. A value of -1 indicates that this feature is not supported … |
| 1.3.6.1.4.1.232.6.2.8.5 | ScalarcpqHeSysUtilEisaBusHour | read-only | mandatory | The EISA bus utilization as a percentage of the theoretical maximum during the last hour. A value of -1 indicates that this feature is not supported on this ma… |
| 1.3.6.1.4.1.232.6.2.8.6 | TablecpqHeSysUtilPciTable | not-accessible | mandatory | A table of PCI utilization numbers for a whole aggregate PCI bus or a specific device on that bus. |
| 1.3.6.1.4.1.232.6.2.8.6.1 | RowcpqHeSysUtilPciEntry | not-accessible | mandatory | PCI utilization entry |
| 1.3.6.1.4.1.232.6.2.8.6.1.1 | ColumncpqHeSysUtilPciIndex | read-only | mandatory | A unique index into each PCI utilization table entry. |
| 1.3.6.1.4.1.232.6.2.8.6.1.2 | ColumncpqHeSysUtilPciBus | read-only | mandatory | The PCI bus number for this set of utilization numbers. |
| 1.3.6.1.4.1.232.6.2.8.6.1.3 | ColumncpqHeSysUtilPciDevice | read-only | mandatory | The PCI device number for this set of utilization numbers. If this value is -1, the utilization reported is for the aggregate of all devices on this PCI bus. |
| 1.3.6.1.4.1.232.6.2.8.6.1.4 | ColumncpqHeSysUtilPciMin | read-only | mandatory | The utilization as a percentage of the theoretical maximum during the last minute. A value of -1 indicates that the utilization number is not available. |
| 1.3.6.1.4.1.232.6.2.8.6.1.5 | ColumncpqHeSysUtilPciFiveMin | read-only | mandatory | The utilization as a percentage of the theoretical maximum during the last five minutes. A value of -1 indicates that the utilization number is not available. |
| 1.3.6.1.4.1.232.6.2.8.6.1.6 | ColumncpqHeSysUtilPciThirtyMin | read-only | mandatory | The utilization as a percentage of the theoretical maximum during the last thirty minutes. A value of -1 indicates that the utilization number is not available. |
| 1.3.6.1.4.1.232.6.2.8.6.1.7 | ColumncpqHeSysUtilPciHour | read-only | mandatory | The utilization as a percentage of the theoretical maximum during the last hour. A value of -1 indicates that the utilization number is not available. |
| 1.3.6.1.4.1.232.6.2.8.6.1.8 | ColumncpqHeSysUtilPciHwLocation | read-only | optional | A text description of the hardware location, on complex multi SBB hardware only, for the PCI drawer. A NULL string indicates that the hardware location could n… |
| 1.3.6.1.4.1.232.6.2.9 | NodecpqHeFltTolPwrSupply | |||
| 1.3.6.1.4.1.232.6.2.9.1 | ScalarcpqHeFltTolPwrSupplyCondition | read-only | mandatory | This value specifies the overall condition of the fault tolerant power supply sub-system. |
| 1.3.6.1.4.1.232.6.2.9.2 | ScalarcpqHeFltTolPwrSupplyStatus | read-only | mandatory | This value specifies the status of the fault tolerant power supply. |
| 1.3.6.1.4.1.232.6.2.9.3 | TablecpqHeFltTolPowerSupplyTable | not-accessible | mandatory | A table of Power Supply Entries. |
| 1.3.6.1.4.1.232.6.2.9.3.1 | RowcpqHeFltTolPowerSupplyEntry | not-accessible | mandatory | A Fault Tolerant Power Supply Entry. |
| 1.3.6.1.4.1.232.6.2.9.3.1.1 | ColumncpqHeFltTolPowerSupplyChassis | read-only | mandatory | The system chassis number. |
| 1.3.6.1.4.1.232.6.2.9.3.1.2 | ColumncpqHeFltTolPowerSupplyBay | read-only | mandatory | The bay number to index within this chassis. |
| 1.3.6.1.4.1.232.6.2.9.3.1.3 | ColumncpqHeFltTolPowerSupplyPresent | read-only | mandatory | Indicates whether the power supply is present in the chassis. |
| 1.3.6.1.4.1.232.6.2.9.3.1.4 | ColumncpqHeFltTolPowerSupplyCondition | read-only | mandatory | The condition of the power supply. This value will be one of the following: other(1) The status could not be determined or not present. ok(2) The power supply … |
| 1.3.6.1.4.1.232.6.2.9.3.1.5 | ColumncpqHeFltTolPowerSupplyStatus | read-only | mandatory | The status of the power supply. |
| 1.3.6.1.4.1.232.6.2.9.3.1.6 | ColumncpqHeFltTolPowerSupplyMainVoltage | read-only | mandatory | The input main voltage of the power supply in volts. |
| 1.3.6.1.4.1.232.6.2.9.3.1.7 | ColumncpqHeFltTolPowerSupplyCapacityUsed | read-only | mandatory | The currently used capacity of the power supply in watts. |
| 1.3.6.1.4.1.232.6.2.9.3.1.8 | ColumncpqHeFltTolPowerSupplyCapacityMaximum | read-only | mandatory | The maximum capacity of the power supply in watts. |
| 1.3.6.1.4.1.232.6.2.9.3.1.9 | ColumncpqHeFltTolPowerSupplyRedundant | read-only | mandatory | The redundancy state of the power supply. This value will be one of the following: other(1) The redundancy state could not be determined. notRedundant(2) The p… |
| 1.3.6.1.4.1.232.6.2.9.3.1.10 | ColumncpqHeFltTolPowerSupplyModel | read-only | mandatory | The power supply model name. |
| 1.3.6.1.4.1.232.6.2.9.3.1.11 | ColumncpqHeFltTolPowerSupplySerialNumber | read-only | mandatory | The power supply serial number. |
| 1.3.6.1.4.1.232.6.2.9.3.1.12 | ColumncpqHeFltTolPowerSupplyAutoRev | read-only | mandatory | The power supply auto revision number. |
| 1.3.6.1.4.1.232.6.2.9.3.1.13 | ColumncpqHeFltTolPowerSupplyHotPlug | read-only | mandatory | This indicates if the power supply is capable of being removed and/or inserted while the system is in an operational state. If the value is hotPluggable(3), th… |
| 1.3.6.1.4.1.232.6.2.9.3.1.14 | ColumncpqHeFltTolPowerSupplyFirmwareRev | read-only | mandatory | The power supply firmware revision. This field will be left blank if the firmware revision is unknown. |
| 1.3.6.1.4.1.232.6.2.9.3.1.15 | ColumncpqHeFltTolPowerSupplyHwLocation | read-only | optional | A text description of the hardware location, on complex multi SBB hardware only, for the power supply. A NULL string indicates that the hardware location could… |
| 1.3.6.1.4.1.232.6.2.9.3.1.16 | ColumncpqHeFltTolPowerSupplySparePartNum | read-only | optional | The power supply part number or spare part number. |
| 1.3.6.1.4.1.232.6.2.9.3.1.17 | ColumncpqHeFltTolPowerSupplyRedundantPartner | read-only | mandatory | This specifies the index of the redundant partner. A value of zero will be used if there is no redundant partner. |
| 1.3.6.1.4.1.232.6.2.9.3.1.18 | ColumncpqHeFltTolPowerSupplyErrorCondition | read-only | mandatory | The Error condition of the power supply. |
| 1.3.6.1.4.1.232.6.2.10 | NodecpqHeIRC | |||
| 1.3.6.1.4.1.232.6.2.10.1 | ScalarcpqHeIRCStatus | read-only | mandatory | The status of the Integrated Remote Console. A value of notavailable will be returned if this system does not contain IRC. |
| 1.3.6.1.4.1.232.6.2.11 | NodecpqHeEventLog | |||
| 1.3.6.1.4.1.232.6.2.11.1 | ScalarcpqHeEventLogSupported | read-write | mandatory | This value specifies if this system supports the Integrated Management Log feature. An SNMP set of the value clear(4) will clear the System Event Log of all en… |
| 1.3.6.1.4.1.232.6.2.11.2 | ScalarcpqHeEventLogCondition | read-only | mandatory | This value specifies the overall condition of the Integrated Management Log feature. |
| 1.3.6.1.4.1.232.6.2.11.3 | TablecpqHeEventLogTable | not-accessible | mandatory | A table of System Event Log Entries. |
| 1.3.6.1.4.1.232.6.2.11.3.1 | RowcpqHeEventLogEntry | not-accessible | mandatory | A System Event Log Entry. |
| 1.3.6.1.4.1.232.6.2.11.3.1.1 | ColumncpqHeEventLogEntryNumber | read-only | mandatory | A number that uniquely specifies this system event log entry. |
| 1.3.6.1.4.1.232.6.2.11.3.1.2 | ColumncpqHeEventLogEntrySeverity | read-write | mandatory | This value specifies the severity of the event log entry. A caution or critical entry can have it's severity lowered by setting this variable to the repaired s… |
| 1.3.6.1.4.1.232.6.2.11.3.1.3 | ColumncpqHeEventLogEntryClass | read-only | mandatory | This value specifies the event log entry class designation. |
| 1.3.6.1.4.1.232.6.2.11.3.1.4 | ColumncpqHeEventLogEntryCode | read-only | mandatory | This value specifies the event log entry code designation. The meaning of this changes depending on the class. |
| 1.3.6.1.4.1.232.6.2.11.3.1.5 | ColumncpqHeEventLogEntryCount | read-only | mandatory | This value specifies the event log entry occurrence count. This represents the number of times this event has occurred starting from the initial time until the… |
| 1.3.6.1.4.1.232.6.2.11.3.1.6 | ColumncpqHeEventLogInitialTime | read-only | mandatory | The time stamp when the event log entry was first created. field octets contents range ===== ====== ======== ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day … |
| 1.3.6.1.4.1.232.6.2.11.3.1.7 | ColumncpqHeEventLogUpdateTime | read-only | mandatory | The time stamp when the event log entry was last modified. field octets contents range ===== ====== ======== ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day … |
| 1.3.6.1.4.1.232.6.2.11.3.1.8 | ColumncpqHeEventLogErrorDesc | read-only | mandatory | A text description of the event log entry. |
| 1.3.6.1.4.1.232.6.2.11.3.1.9 | ColumncpqHeEventLogFreeFormData | read-only | mandatory | This is the free form data associated with a particular event. |
| 1.3.6.1.4.1.232.6.2.12 | NodecpqHeMgmtDisplay | |||
| 1.3.6.1.4.1.232.6.2.12.1 | ScalarcpqHeMgmtDisplayType | read-only | mandatory | This value specifies the type of Management Display device. If a display device is available on the server, the type will be set accordingly. If no device is p… |
| 1.3.6.1.4.1.232.6.2.12.2 | ScalarcpqHeMgmtDisplayText | read-write | mandatory | The text to be written to the Management display device. If this item is read, it may not accurately reflect what is currently displayed. |
| 1.3.6.1.4.1.232.6.2.12.3 | ScalarcpqHeMgmtUID | read-write | mandatory | The Unit Identifier LED. This value will be one of the following: other(1) The state of the LED could not be determined. Setting the LED state is not allowed. … |
| 1.3.6.1.4.1.232.6.2.13 | NodecpqHePowerConverter | |||
| 1.3.6.1.4.1.232.6.2.13.1 | ScalarcpqHePowerConverterSupported | read-only | mandatory | This value specifies if this system supports reporting power converter module information. |
| 1.3.6.1.4.1.232.6.2.13.2 | ScalarcpqHePowerConverterCondition | read-only | mandatory | This value specifies the overall condition of the power converters modules in the system. |
| 1.3.6.1.4.1.232.6.2.13.3 | TablecpqHePowerConverterTable | not-accessible | mandatory | A table of Power Converter Module Entries. |
| 1.3.6.1.4.1.232.6.2.13.3.1 | RowcpqHePowerConverterEntry | not-accessible | mandatory | A Power Converter Module Entry. |
| 1.3.6.1.4.1.232.6.2.13.3.1.1 | ColumncpqHePwrConvChassis | read-only | mandatory | The system chassis number containing the power converter modules. |
| 1.3.6.1.4.1.232.6.2.13.3.1.2 | ColumncpqHePwrConvIndex | read-only | mandatory | The Power Converter Module number to index within the chassis. |
| 1.3.6.1.4.1.232.6.2.13.3.1.3 | ColumncpqHePwrConvPresent | read-only | mandatory | This specifies if the Power Converter Module described is present in the system. |
| 1.3.6.1.4.1.232.6.2.13.3.1.4 | ColumncpqHePwrConvSlot | read-only | mandatory | The Power Converter Module slot number within the chassis. |
| 1.3.6.1.4.1.232.6.2.13.3.1.5 | ColumncpqHePwrConvSocket | read-only | mandatory | The Power Converter Module socket number within the slot. |
| 1.3.6.1.4.1.232.6.2.13.3.1.6 | ColumncpqHePwrConvRedundant | read-only | mandatory | This specifies if the Power Converter Module is redundant. |
| 1.3.6.1.4.1.232.6.2.13.3.1.7 | ColumncpqHePwrConvRedundantGroupId | read-only | mandatory | The Power Converter Module group id. A redundant set of power converters will have the same group id. |
| 1.3.6.1.4.1.232.6.2.13.3.1.8 | ColumncpqHePwrConvCondition | read-only | mandatory | The Power Converter Module condition. |
| 1.3.6.1.4.1.232.6.2.13.3.1.9 | ColumncpqHePwrConvHwLocation | read-only | optional | A text description of the hardware location, on complex multi SBB hardware only, for the power converter. A NULL string indicates that the hardware location co… |
| 1.3.6.1.4.1.232.6.2.14 | NodecpqHeResilientMemory | |||
| 1.3.6.1.4.1.232.6.2.14.1 | ScalarcpqHeResilientMemTypeActive | read-only | mandatory | This value specifies the type of Advanced Memory Protection fault tolerance currently active on the system. The following connection states are supported: othe… |
| 1.3.6.1.4.1.232.6.2.14.2 | ScalarcpqHeResilientMemTypeAvailable | read-only | mandatory | This value specifies the type of Advanced Memory Protection Fault Tolerance available on the system. This is a collection of flags used to indicate the fault A… |
| 1.3.6.1.4.1.232.6.2.14.3 | ScalarcpqHeResilientMemStatus | read-only | mandatory | This value specifies the current state of the Advanced Memory Protection subsystem. The following states are supported: other(1) The system does not support Ad… |
| 1.3.6.1.4.1.232.6.2.14.4 | ScalarcpqHeResilientMemCondition | read-only | mandatory | This value specifies the current condition of the Advanced Memory Protection subsystem. The following states are supported: other(1) The system does not suppor… |
| 1.3.6.1.4.1.232.6.2.14.5 | ScalarcpqHeResilientMemHotPlug | read-only | mandatory | This value specifies the current condition of the Advanced Memory Protection subsystem. The following states are supported: other(1) The state could not be det… |
| 1.3.6.1.4.1.232.6.2.14.6 | ScalarcpqHeResilientMemOperatingSpeed | read-only | mandatory | This value specifies the current operating speed of the Advanced Memory Protection subsystem in MHz. If this system does not support Advanced Memory Protection… |
| 1.3.6.1.4.1.232.6.2.14.7 | ScalarcpqHeResilientMemOsMemSize | read-only | mandatory | This value specifies the size of memory as seen by the Operating System in MB (1 MB = 1048576 bytes). If this system does not support Advanced Memory Protectio… |
| 1.3.6.1.4.1.232.6.2.14.8 | ScalarcpqHeResilientMemTotalMemSize | read-only | mandatory | This value specifies the total size of memory including memory seen by the Operating System and the memory used for spare, mirrored, or RAID configurations in … |
| 1.3.6.1.4.1.232.6.2.14.9 | ScalarcpqHeResilientMemRivState | read-only | mandatory | This value specifies the state of the Rebuild/Initialize/Verify (RIV) engine of the Advanced Memory Protection sub-system. The following states are supported: … |
| 1.3.6.1.4.1.232.6.2.14.10 | TablecpqHeResMemBoardTable | not-accessible | mandatory | A table of memory board or cartridge descriptions in Advanced Memory Protection systems. |
| 1.3.6.1.4.1.232.6.2.14.10.1 | RowcpqHeResMemBoardEntry | not-accessible | mandatory | A memory board or cartridge description. |
| 1.3.6.1.4.1.232.6.2.14.10.1.1 | ColumncpqHeResMemBoardSlotIndex | read-only | mandatory | The slot in which the memory board or cartridge is installed. |
| 1.3.6.1.4.1.232.6.2.14.10.1.2 | ColumncpqHeResMemBoardOnlineStatus | read-only | mandatory | The online status of the Advanced Memory Protection board or cartridge. The following status values are supported: other(1) The value is unsupported or could n… |
| 1.3.6.1.4.1.232.6.2.14.10.1.3 | ColumncpqHeResMemBoardErrorStatus | read-only | mandatory | The error status of the Advanced Memory Protection board or cartridge. The following status values are supported: other(1) The value is unsupported or could no… |
| 1.3.6.1.4.1.232.6.2.14.10.1.4 | ColumncpqHeResMemBoardLocked | read-only | mandatory | The locked state of the Advanced Memory Protection board or cartridge. The following status values are supported: other(1) The value is unsupported or could no… |
| 1.3.6.1.4.1.232.6.2.14.10.1.5 | ColumncpqHeResMemBoardNumSockets | read-only | mandatory | The total number of memory sockets for this memory board or cartridge. If this value could not be determined, or if the board or cartridge has been removed, th… |
| 1.3.6.1.4.1.232.6.2.14.10.1.6 | ColumncpqHeResMemBoardOsMemSize | read-only | mandatory | This value specifies the size of memory for this board or cartridge as seen by the Operating System in MB (1 MB = 1048576 bytes). If this system does not suppo… |
| 1.3.6.1.4.1.232.6.2.14.10.1.7 | ColumncpqHeResMemBoardTotalMemSize | read-only | mandatory | This value specifies the size of memory for this board or cartridge including memory seen by the Operating System and the memory used for spare, mirrored, or X… |
| 1.3.6.1.4.1.232.6.2.14.10.1.8 | ColumncpqHeResMemBoardCondition | read-only | mandatory | This provides the current status of the Advanced Memory Protection memory board or cartridge. The following status values are supported: other(1): The conditio… |
| 1.3.6.1.4.1.232.6.2.14.10.1.9 | ColumncpqHeResMemBoardHotPlug | read-only | mandatory | This indicates if the memory board is capable of being removed and/or inserted while the system is in an operational state. The following states are supported:… |
| 1.3.6.1.4.1.232.6.2.14.11 | TablecpqHeResMemModuleTable | not-accessible | mandatory | A table of memory module descriptions. |
| 1.3.6.1.4.1.232.6.2.14.11.1 | RowcpqHeResMemModuleEntry | not-accessible | mandatory | A memory module description. |
| 1.3.6.1.4.1.232.6.2.14.11.1.1 | ColumncpqHeResMemBoardIndex | read-only | mandatory | The slot in which the memory board or cartridge is installed. A value of 0 indicates memory installed directly on the system board. |
| 1.3.6.1.4.1.232.6.2.14.11.1.2 | ColumncpqHeResMemModuleIndex | read-only | mandatory | The memory module number. |
| 1.3.6.1.4.1.232.6.2.14.11.1.3 | ColumncpqHeResMemModuleSparePartNo | read-only | mandatory | The memory module's manufacturer part number. This field will be a null (size 0) string if the manufacturer part number is not available. |
| 1.3.6.1.4.1.232.6.2.14.11.1.4 | ColumncpqHeResMemModuleStatus | read-only | mandatory | This provides the current status of the correctable memory errors for this memory module. The following status values are supported: other(1): The status is un… |
| 1.3.6.1.4.1.232.6.2.14.11.1.5 | ColumncpqHeResMemModuleCondition | read-only | mandatory | This provides the current status of the correctable memory errors for this memory module. The following status values are supported: other(1): ECC is not suppo… |
| 1.3.6.1.4.1.232.6.2.14.11.1.6 | ColumncpqHeResMemModuleSpd | read-only | mandatory | This is the raw Serial Presence Detect information contained in the memory module. If the SPD information is not available, this item will be empty. |
| 1.3.6.1.4.1.232.6.2.14.12 | TablecpqHeResMem2BoardTable | not-accessible | mandatory | A table of memory board or cartridge descriptions in Advanced Memory Protection systems. |
| 1.3.6.1.4.1.232.6.2.14.12.1 | RowcpqHeResMem2BoardEntry | not-accessible | mandatory | A memory board or cartridge or CPU based Memory Board description. |
| 1.3.6.1.4.1.232.6.2.14.12.1.1 | ColumncpqHeResMem2BoardIndex | read-only | mandatory | This will represent the unique memory board or cartridge or riser. |
| 1.3.6.1.4.1.232.6.2.14.12.1.2 | ColumncpqHeResMem2BoardSlotNum | read-only | mandatory | The slot in which the memory board or cartridge is installed. |
| 1.3.6.1.4.1.232.6.2.14.12.1.3 | ColumncpqHeResMem2BoardCpuNum | read-only | mandatory | The Processor Number to which the memory Riser belongs. Value 0 means memory is not CPU based. |
| 1.3.6.1.4.1.232.6.2.14.12.1.4 | ColumncpqHeResMem2BoardRiserNum | read-only | mandatory | The Riser Number on the Processor. |
| 1.3.6.1.4.1.232.6.2.14.12.1.5 | ColumncpqHeResMem2BoardOnlineStatus | read-only | mandatory | The online status of the Advanced Memory Protection board or cartridge or riser. The following status values are supported: other(1) The value is unsupported o… |
| 1.3.6.1.4.1.232.6.2.14.12.1.6 | ColumncpqHeResMem2BoardErrorStatus | read-only | mandatory | The error status of the Advanced Memory Protection board or Cartridge or riser. The following status values are supported: other(1) The value is unsupported or… |
| 1.3.6.1.4.1.232.6.2.14.12.1.7 | ColumncpqHeResMem2BoardLocked | read-only | mandatory | The locked state of the Advanced Memory Protection board or Cartridge or riser. The following status values are supported: other(1) The value is unsupported or… |
| 1.3.6.1.4.1.232.6.2.14.12.1.8 | ColumncpqHeResMem2BoardNumSockets | read-only | mandatory | The total number of memory sockets for this memory board or Cartridge or riser. If this value could not be determined, or if the board or Cartridge or riser ha… |
| 1.3.6.1.4.1.232.6.2.14.12.1.9 | ColumncpqHeResMem2BoardOsMemSize | read-only | mandatory | This value specifies the size of memory for this board or cartridge or riser as seen by the Operating System in MB (1 MB = 1048576 bytes). If this system does … |
| 1.3.6.1.4.1.232.6.2.14.12.1.10 | ColumncpqHeResMem2BoardTotalMemSize | read-only | mandatory | This value specifies the size of memory for this board or Cartridge or riser including memory seen by the Operating System and the memory used for spare, mirro… |
| 1.3.6.1.4.1.232.6.2.14.12.1.11 | ColumncpqHeResMem2BoardCondition | read-only | mandatory | This provides the current status of the Advanced Memory Protection memory board or cartridge or riser. The following status values are supported: other(1): The… |
| 1.3.6.1.4.1.232.6.2.14.12.1.12 | ColumncpqHeResMem2BoardHotPlug | read-only | mandatory | This indicates if the memory board is capable of being removed and/or inserted while the system is in an operational state. The following states are supported:… |
| 1.3.6.1.4.1.232.6.2.14.12.1.13 | ColumncpqHeResMem2BoardOperatingFrequency | read-only | mandatory | This value specifies the operational memory frequency for this board or Cartridge or riser in MHz. |
| 1.3.6.1.4.1.232.6.2.14.12.1.14 | ColumncpqHeResMem2BoardOperatingVoltage | read-only | mandatory | This value specifies the operational memory voltage for this board or Cartridge or riser in millivolts. |
| 1.3.6.1.4.1.232.6.2.14.13 | TablecpqHeResMem2ModuleTable | not-accessible | mandatory | A table of memory module descriptions. |
| 1.3.6.1.4.1.232.6.2.14.13.1 | RowcpqHeResMem2ModuleEntry | not-accessible | mandatory | A memory module description. |
| 1.3.6.1.4.1.232.6.2.14.13.1.1 | ColumncpqHeResMem2Module | read-only | mandatory | This will represent the unique memory DIMM on memory board or cartridge or riser. |
| 1.3.6.1.4.1.232.6.2.14.13.1.2 | ColumncpqHeResMem2BoardNum | read-only | mandatory | The slot in which the memory board or cartridge is installed. A value of 0 indicates memory installed directly on the system board. |
| 1.3.6.1.4.1.232.6.2.14.13.1.3 | ColumncpqHeResMem2CpuNum | read-only | mandatory | The memory module CPU number. Value 0 means memory is not Processor based. |
| 1.3.6.1.4.1.232.6.2.14.13.1.4 | ColumncpqHeResMem2RiserNum | read-only | mandatory | The memory module rasier number. |
| 1.3.6.1.4.1.232.6.2.14.13.1.5 | ColumncpqHeResMem2ModuleNum | read-only | mandatory | The memory module number. |
| 1.3.6.1.4.1.232.6.2.14.13.1.6 | ColumncpqHeResMem2ModuleSize | read-only | mandatory | Module memory size in kilobytes. A kilobyte of memory is defined as 1024 bytes. A size of 0 indicates the module is not present. |
| 1.3.6.1.4.1.232.6.2.14.13.1.7 | ColumncpqHeResMem2ModuleType | read-only | mandatory | Type of memory module installed. The value other(1) will be given if the type is not known. The value board(2) will be given if the memory module is permanentl… |
| 1.3.6.1.4.1.232.6.2.14.13.1.8 | ColumncpqHeResMem2ModuleTechnology | read-only | mandatory | Technology type of memory module installed. The value other(1) will be given if the technology is not known. |
| 1.3.6.1.4.1.232.6.2.14.13.1.9 | ColumncpqHeResMem2ModuleManufacturer | read-only | mandatory | The memory module's manufacturer name. This field will be a null (size 0) string if the manufacturer name is not available. |
| 1.3.6.1.4.1.232.6.2.14.13.1.10 | ColumncpqHeResMem2ModulePartNo | read-only | mandatory | The memory module's manufacturer part number. This field will be a null (size 0) string if the manufacturer part number is not available. |
| 1.3.6.1.4.1.232.6.2.14.13.1.11 | ColumncpqHeResMem2ModuleDate | read-only | mandatory | The memory module date of manufacture. field octets contents range ===== ====== ====================== ======== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..… |
| 1.3.6.1.4.1.232.6.2.14.13.1.12 | ColumncpqHeResMem2ModuleSerialNo | read-write | mandatory | The memory module's serial number. This field will be a null (size 0) string if the serial number is not available. |
| 1.3.6.1.4.1.232.6.2.14.13.1.13 | ColumncpqHeResMem2ModuleHwLocation | read-only | optional | A text description of the hardware location, on complex multi SBB hardware only, for the memory module. A NULL string indicates that the hardware location coul… |
| 1.3.6.1.4.1.232.6.2.14.13.1.14 | ColumncpqHeResMem2ModuleFrequency | read-only | mandatory | The memory module maximum frequency in MHz. The value zero (0) will be given if the module frequency cannot be determined. |
| 1.3.6.1.4.1.232.6.2.14.13.1.15 | ColumncpqHeResMem2ModuleCellTablePtr | read-only | optional | Index for the cell in cpqSeCellTable where the memory board is installed. |
| 1.3.6.1.4.1.232.6.2.14.13.1.16 | ColumncpqHeResMem2ModuleCellStatus | read-only | optional | This provides the current status for this memory module. The following status values are supported: other(1): The memory module status is not available ok(2): … |
| 1.3.6.1.4.1.232.6.2.14.13.1.17 | ColumncpqHeResMem2ModulePartNoMfgr | read-only | optional | The memory module's manufacturer's part number. This field will be a null (size 0) string if the manufacturer part number is not available. |
| 1.3.6.1.4.1.232.6.2.14.13.1.18 | ColumncpqHeResMem2ModuleSerialNoMfgr | read-only | optional | The memory module's manufacturer's serial number. This field will be a null (size 0) string if the manufacturer serial number is not available. |
| 1.3.6.1.4.1.232.6.2.14.13.1.19 | ColumncpqHeResMem2ModuleStatus | read-only | mandatory | This provides the current status of the correctable memory errors for this memory module. The following status values are supported: other(1): The status is un… |
| 1.3.6.1.4.1.232.6.2.14.13.1.20 | ColumncpqHeResMem2ModuleCondition | read-only | mandatory | This provides the current status of the correctable memory errors for this memory module. The following status values are supported: other(1): ECC is not suppo… |
| 1.3.6.1.4.1.232.6.2.14.13.1.21 | ColumncpqHeResMem2ModuleSpd | read-only | mandatory | This is the raw Serial Presence Detect information contained in the memory module. If the SPD information is not available, this item will be empty. NOTE: SPD … |
| 1.3.6.1.4.1.232.6.2.14.13.1.22 | ColumncpqHeResMem2ModuleSmartMemory | read-only | mandatory | This indicates whether the DIMM slot is populated with HP Smart Memory or HP Standard Memory DIMM. The following values are supported: other(1): HP SmartMemory… |
| 1.3.6.1.4.1.232.6.2.14.13.1.23 | ColumncpqHeResMem2ModuleMinVoltage | read-only | mandatory | This provides the minimum voltage needed for the module to operate, in millivolts. |
| 1.3.6.1.4.1.232.6.2.14.13.1.24 | ColumncpqHeResMem2ModuleRanks | read-only | mandatory | This provides the number of physical ranks on the module. |
| 1.3.6.1.4.1.232.6.2.15 | NodecpqHePowerMeter | |||
| 1.3.6.1.4.1.232.6.2.15.1 | ScalarcpqHePowerMeterSupport | read-only | mandatory | This value specifies whether Power Meter is supported by this Server . The following values are supported: other(1) Could not read the Power Meter status. supp… |
| 1.3.6.1.4.1.232.6.2.15.2 | ScalarcpqHePowerMeterStatus | read-only | mandatory | This value specifies whether Power Meter reading is supported by this Server . The following values are supported: other(1) Could not read the Power Meter stat… |
| 1.3.6.1.4.1.232.6.2.15.3 | ScalarcpqHePowerMeterCurrReading | read-only | mandatory | This is the current Power Meter reading in Watts. This value shows the most recent power reading if available. On systems without Power Meter support, this val… |
| 1.3.6.1.4.1.232.6.2.15.4 | ScalarcpqHePowerMeterPrevReading | read-only | mandatory | This is the previous Power Meter reading in Watts. This value shows previous power reading if available. On systems without Power Meter support, this value wil… |
| 1.3.6.1.4.1.232.6.2.16 | NodecpqHeHWBios | |||
| 1.3.6.1.4.1.232.6.2.16.1 | ScalarcpqHeHWBiosCondition | read-only | mandatory | This value indicates an error has been detected during Pre-OS Test (POST) or during initial hardware initialization. Typically, this will be a hardware interlo… |
| 1.3.6.1.4.1.232.6.2.17 | NodecpqHeSysBackupBattery | |||
| 1.3.6.1.4.1.232.6.2.17.1 | ScalarcpqHeSysBackupBatteryCondition | read-only | mandatory | This value specifies the overall condition of the battery backup sub-system. |
| 1.3.6.1.4.1.232.6.2.17.2 | TablecpqHeSysBatteryTable | not-accessible | mandatory | A table of battery entries. |
| 1.3.6.1.4.1.232.6.2.17.2.1 | RowcpqHeSysBatteryEntry | not-accessible | mandatory | A System Backup Battery Entry. |
| 1.3.6.1.4.1.232.6.2.17.2.1.1 | ColumncpqHeSysBatteryChassis | read-only | mandatory | The system chassis number. |
| 1.3.6.1.4.1.232.6.2.17.2.1.2 | ColumncpqHeSysBatteryIndex | read-only | mandatory | The battery index number within this chassis. |
| 1.3.6.1.4.1.232.6.2.17.2.1.3 | ColumncpqHeSysBatteryPresent | read-only | mandatory | Indicates whether the backup battery is present in the chassis. |
| 1.3.6.1.4.1.232.6.2.17.2.1.4 | ColumncpqHeSysBatteryCondition | read-only | mandatory | The condition of the backup battery. This value will be one of the following: other(1) The status could not be determined or not present. ok(2) The battery is … |
| 1.3.6.1.4.1.232.6.2.17.2.1.5 | ColumncpqHeSysBatteryStatus | read-only | mandatory | The status of the battery. |
| 1.3.6.1.4.1.232.6.2.17.2.1.6 | ColumncpqHeSysBatteryCapacityMaximum | read-only | mandatory | The maximum capacity of the battery in watts. |
| 1.3.6.1.4.1.232.6.2.17.2.1.7 | ColumncpqHeSysBatteryProductName | read-only | mandatory | The battery product name. |
| 1.3.6.1.4.1.232.6.2.17.2.1.8 | ColumncpqHeSysBatteryModel | read-only | mandatory | The battery model name. |
| 1.3.6.1.4.1.232.6.2.17.2.1.9 | ColumncpqHeSysBatterySerialNumber | read-only | mandatory | The battery serial number. |
| 1.3.6.1.4.1.232.6.2.17.2.1.10 | ColumncpqHeSysBatteryFirmwareRev | read-only | mandatory | The battery firmware revision. This field will be left blank if the firmware revision is unknown. |
| 1.3.6.1.4.1.232.6.2.17.2.1.11 | ColumncpqHeSysBatterySparePartNum | read-only | optional | The battery part number or spare part number. |
| 1.3.6.1.4.1.232.6.2.18 | NodecpqHeSysPwrHw | |||
| 1.3.6.1.4.1.232.6.2.18.1 | ScalarcpqHeSysPwrAllocationOptimizeStatus | read-only | mandatory | This value specifies if server power throttle setting failed or not. |
| 1.3.6.1.4.1.232.6.2.19 | NodecpqHeSysBoardFru | |||
| 1.3.6.1.4.1.232.6.2.19.1 | ScalarcpqHeSysBoardFruStatus | read-only | mandatory | This is an array of status values representing the board fru status. Octet Element Field ======== ======= ========= 0 0 Base board FRU 1 1 Mezzanine Card 1 2 2… |
| 1.3.6.1.4.1.232.6.2.20 | NodecpqHePowerFailure | |||
| 1.3.6.1.4.1.232.6.2.20.1 | ScalarcpqHePowerFailureSupported | read-only | mandatory | This value specifies whether this server supports power failure monitoring. |
| 1.3.6.1.4.1.232.6.2.20.2 | TablecpqHePowerFailureTable | not-accessible | mandatory | A table of Power Fault Entries. |
| 1.3.6.1.4.1.232.6.2.20.2.1 | RowcpqHePowerFailureTableEntry | not-accessible | mandatory | The server power failure details. |
| 1.3.6.1.4.1.232.6.2.20.2.1.1 | ColumncpqHePowerFailureIndex | read-only | mandatory | The index uniquely identifies 1 of 16 areas on the system board. |
| 1.3.6.1.4.1.232.6.2.20.2.1.2 | ColumncpqHePowerFailureStatus | read-only | mandatory | The status of this table entry. The value will be one of the following: ok(1) There is no failed device in this area. failed(2) A device has failed in this are… |
| 1.3.6.1.4.1.232.6.2.20.2.1.3 | ColumncpqHePowerFailureDeviceID | read-only | mandatory | The unique id of the failed power device on the system board. |
| 1.3.6.1.4.1.232.6.2.20.2.1.4 | ColumncpqHePowerFailureArea | read-only | mandatory | This field enumerates the area on the system board. The value will be one of the following: systemBoard(1) General processor(2) Processor memory(3) Memory memo… |
| 1.3.6.1.4.1.232.6.2.20.2.1.5 | ColumncpqHePowerFailureDeviceBitMap | read-only | mandatory | The hex representation of the device(s) within the specified area. |
| 1.3.6.1.4.1.232.6.2.20.2.1.6 | ColumncpqHePowerFailureGroupString | read-only | mandatory | The location of the device on the system board. |
| 1.3.6.1.4.1.232.6.2.20.2.1.7 | ColumncpqHePowerFailureRepairSteps | read-only | mandatory | Recommended troubleshooting steps for a particular device error. The value will be one of the following: noError(1) No errors were detected at this time. syste… |
| 1.3.6.1.4.1.232.6.2.20.2.1.8 | ColumncpqHePowerFailureType | read-only | mandatory | Critical power failure that occurred. The value will be one of the following: noError(1) No error has occurred. tempDeadly(2) The server was shut down because … |
| 1.3.6.1.4.1.232.6.2.21 | NodecpqHeInterlockFailure | |||
| 1.3.6.1.4.1.232.6.2.21.1 | ScalarcpqHeInterlockFailureSupported | read-only | mandatory | This value specifies whether this server supports Interlock failure monitoring. |
| 1.3.6.1.4.1.232.6.2.21.2 | TablecpqHeInterlockFailureTable | not-accessible | mandatory | A table of Interlock Table Entries. |
| 1.3.6.1.4.1.232.6.2.21.2.1 | RowcpqHeInterlockFailureTableEntry | not-accessible | mandatory | The Interlock failure details. |
| 1.3.6.1.4.1.232.6.2.21.2.1.1 | ColumncpqHeInterlockFailureIndex | read-only | mandatory | The index uniquely identifies 1 of 16 areas on the system board. |
| 1.3.6.1.4.1.232.6.2.21.2.1.2 | ColumncpqHeInterlockFailureStatus | read-only | mandatory | The status of this table entry. The value will be one of the following: ok(1) There are no missing devices in this area. failed(2) A device is missing or impro… |
| 1.3.6.1.4.1.232.6.2.21.2.1.3 | ColumncpqHeInterlockFailureDeviceID | read-only | mandatory | The unique id of the missing or improperly seated device on the system board. |
| 1.3.6.1.4.1.232.6.2.21.2.1.4 | ColumncpqHeInterlockFailureArea | read-only | mandatory | This field enumerates the area on the system board. The value will be one of the following: systemBoard(1) General processor(2) Processor memory(3) Memory memo… |
| 1.3.6.1.4.1.232.6.2.21.2.1.5 | ColumncpqHeInterlockFailureDeviceName | read-only | mandatory | The name of the missing or improperly seated device. |
| 1.3.6.1.4.1.232.6.2.21.2.1.6 | ColumncpqHeInterlockFailureType | read-only | mandatory | The type of critical Interlock failure that occurred. The value will be one of the following: noError(1) No error has occurred. standby(2) The server had a pow… |
| 1.3.6.1.4.1.232.6.2.22 | NodecpqHeNvdimm | |||
| 1.3.6.1.4.1.232.6.2.22.1 | ScalarcpqHeNvdimmCondition | read-only | mandatory | This value specifies the overall condition of the NVDIMM sub-system. |
| 1.3.6.1.4.1.232.6.2.22.2 | TablecpqHeNvdimmTable | not-accessible | mandatory | A table of NVDIMM entries. |
| 1.3.6.1.4.1.232.6.2.22.2.1 | RowcpqHeNvdimmTableEntry | not-accessible | mandatory | A NVDIMM Entry. |
| 1.3.6.1.4.1.232.6.2.22.2.1.1 | ColumncpqHeNvdimmDimmNum | read-only | mandatory | NVDIMM module number. |
| 1.3.6.1.4.1.232.6.2.22.2.1.2 | ColumncpqHeNvdimmProcessorNum | read-only | mandatory | The memory module Processor number |
| 1.3.6.1.4.1.232.6.2.22.2.1.3 | ColumncpqHeNvdimmType | read-only | mandatory | NVDIMM technologies. |
| 1.3.6.1.4.1.232.6.2.22.2.1.4 | ColumncpqHeNvdimmMemoryMedia | read-only | mandatory | Memory media type. |
| 1.3.6.1.4.1.232.6.2.22.2.1.5 | ColumncpqHeNvdimmStatus | read-only | mandatory | BIT0: Init complete status BIT1: Health status BIT2: Backup power health status BIT3: Backup enabled |
| 1.3.6.1.4.1.232.6.2.22.2.1.6 | ColumncpqHeNvdimmBackupStatus | read-only | mandatory | Last Backup Operation Status |
| 1.3.6.1.4.1.232.6.2.22.2.1.7 | ColumncpqHeNvdimmRestoreStatus | read-only | mandatory | Last Restore Operation Status |
| 1.3.6.1.4.1.232.6.2.22.2.1.8 | ColumncpqHeNvdimmEraseStatus | read-only | mandatory | Last Erase Operation Status |
| 1.3.6.1.4.1.232.6.2.22.2.1.9 | ColumncpqHeNvdimmPredictedMediaLifePercent | read-only | mandatory | Predicated Media Life.(Applicable for only TYPE-N NVDIMM) |
| 1.3.6.1.4.1.232.6.2.22.2.1.10 | ColumncpqHeNvdimmPersistentRegionSizeLimitMiB | read-only | mandatory | Total size of persistent regions in MiB. |
| 1.3.6.1.4.1.232.6.2.22.2.1.11 | ColumncpqHeNvdimmVolatileRegionSizeLimitMiB | read-only | mandatory | Total size of volatile regions in MiB. |
| 1.3.6.1.4.1.232.6.2.22.2.1.12 | ColumncpqHeNvdimmPwrSource | read-only | mandatory | NVDIMM backup power source. |
| 1.3.6.1.4.1.232.6.2.22.2.1.13 | ColumncpqHeNvdimmFirmwareRev | read-only | mandatory | The NVDIMM firmware revision. This field will be left blank if the firmware revision is unknown. |
| 1.3.6.1.4.1.232.6.2.22.2.1.14 | ColumncpqHeNvdimmMfrId | read-only | mandatory | Manufacturer Id. |
| 1.3.6.1.4.1.232.6.2.22.2.1.15 | ColumncpqHeNvdimmMfrLocation | read-only | mandatory | Manufacturer Location. |
| 1.3.6.1.4.1.232.6.2.22.2.1.16 | ColumncpqHeNvdimmMfrDate | read-only | mandatory | Manufacture Date. |
| 1.3.6.1.4.1.232.6.2.22.2.1.17 | ColumncpqHeNvdimmSerialNumber | read-only | mandatory | Serial Number. |
| 1.3.6.1.4.1.232.6.2.22.2.1.18 | ColumncpqHeNvdimmAssociatedNVMeDrive | read-only | mandatory | Comma separated value representing associated NVMe drives.(Applicable only if cpqHeNvdimmType is Type-Logical(5)) |
| 1.3.6.1.4.1.232.6.2.22.2.1.19 | ColumncpqHeNvdimmAssociatedUPS | read-only | mandatory | Comma separated value represnting associated UPS.(Applicable only if cpqHeNvdimmType is Type-Logical(5)) |
| 1.3.6.1.4.1.232.6.2.23 | NodecpqHeBbu | |||
| 1.3.6.1.4.1.232.6.2.23.1 | ScalarcpqHeBbuCondition | read-only | mandatory | This value specifies the overall condition of the BBU sub-system. |
| 1.3.6.1.4.1.232.6.2.23.2 | TablecpqHeBbuTable | not-accessible | mandatory | A table of Battery Backup Unit Entries. |
| 1.3.6.1.4.1.232.6.2.23.2.1 | RowcpqHeBbuEntry | not-accessible | mandatory | A Battery Backup Unit Entry. |
| 1.3.6.1.4.1.232.6.2.23.2.1.1 | ColumncpqHeBbuChassis | read-only | mandatory | The system chassis number. |
| 1.3.6.1.4.1.232.6.2.23.2.1.2 | ColumncpqHeBbuBay | read-only | mandatory | The bay number to index within this chassis. |
| 1.3.6.1.4.1.232.6.2.23.2.1.3 | ColumncpqHeBbuStatus | read-only | mandatory | Indicates status of the bbu. The following values are defined: unknown(1) Not able to determine the battery status ok(2) Battery status is fine failure(3) Batt… |
| 1.3.6.1.4.1.232.6.2.23.2.1.4 | ColumncpqHeBbuTimeToCutoff | read-only | mandatory | Run time (in seconds) available with the battery backup unit until cut off. This is detected only when battery is charging or discharging, otherwise set to 0. |
| 1.3.6.1.4.1.232.6.2.23.2.1.5 | ColumncpqHeBbuTimeToCharge | read-only | mandatory | Time required (in minutes) to fully charge the battery backup unit. This is detected only when battery is charging or discharging, otherwise set to 0. |
| 1.3.6.1.4.1.232.6.2.23.2.1.6 | ColumncpqHeBbuRatedCapacity | read-only | mandatory | Rated capacity (mAh) of the battery backup unit. |
| 1.3.6.1.4.1.232.6.2.23.2.1.7 | ColumncpqHeBbuPresentCapacity | read-only | mandatory | Present capacity (mAh) of the battery backup unit. |
| 1.3.6.1.4.1.232.6.2.23.2.1.8 | ColumncpqHeBbuCutoffCapacity | read-only | mandatory | Cutoff capacity (mAh) of the battery backup unit. |
| 1.3.6.1.4.1.232.6.2.23.2.1.9 | ColumncpqHeBbuCutoffSetPoint | read-only | mandatory | Cutoff threshold (mAh) defined by firmware required to complete operations. |
| 1.3.6.1.4.1.232.6.2.23.2.1.10 | ColumncpqHeBbuChargePercentage | read-only | mandatory | Percentage charge remaining for the battery backup unit. |
| 1.3.6.1.4.1.232.6.2.23.2.1.11 | ColumncpqHeBbuSerialNumber | read-only | mandatory | Serial number of the battery backup unit. |
| 1.3.6.1.4.1.232.6.2.23.2.1.12 | ColumncpqHeBbuMaxCapacityWatts | read-only | mandatory | Total capacity (in Watts) of the battery backup unit. |
| 1.3.6.1.4.1.232.6.2.23.2.1.13 | ColumncpqHeBbuFirmware | read-only | mandatory | Firmware version of the battery backup unit. |
| 1.3.6.1.4.1.232.6.2.23.2.1.14 | ColumncpqHeBbuChargeState | read-only | mandatory | Charge state of the battery backup unit. |
| 1.3.6.1.4.1.232.6.2.23.2.1.15 | ColumncpqHeBbuErrorCondition | read-only | mandatory | The error condition of the battery backup unit. |
| 1.3.6.1.4.1.232.6.3 | NodecpqHeTrap | |||
| 1.3.6.1.4.1.232.6.3.1 | ScalarcpqHeTrapPkts | read-only | deprecated | The total number of SNMP trap packets issued by the Server Health agent. |
| 1.3.6.1.4.1.232.6.3.2 | ScalarcpqHeTrapLogMaxSize | read-only | deprecated | The maximum number of entries that will currently be kept in the trap log. If the maximum size has been reached and a new trap occurs the oldest trap will be r… |
| 1.3.6.1.4.1.232.6.3.3 | TablecpqHeTrapLogTable | not-accessible | deprecated | An ordered list of trap log entries (conceptually a queue). The trap log entries will be kept in the order in which they were generated with the most recent tr… |
| 1.3.6.1.4.1.232.6.3.3.1 | RowcpqHeTrapLogEntry | not-accessible | deprecated | A description of a trap event. |
| 1.3.6.1.4.1.232.6.3.3.1.1 | ColumncpqHeTrapLogIndex | read-only | deprecated | The value of this object uniquely identifies this trapLogEntry at this time. The most recent trap will have an index of 1 and the oldest trap will have an inde… |
| 1.3.6.1.4.1.232.6.3.3.1.2 | ColumncpqHeTrapType | read-only | deprecated | The type of the trap event this entry describes. This number refers to an entry in a list of traps enumerating the possible traps the Server Health agent may i… |
| 1.3.6.1.4.1.232.6.3.3.1.3 | ColumncpqHeTrapTime | read-only | deprecated | The time of the trap event that this entry describes. The time is given in year (first octet), month, day of month, hour, minute, second (last octet) order. Th… |
| 1.3.6.1.4.1.232.6001 | NodecpqHe2CorrectableMemoryError | A correctable memory error occurred. The error has been corrected. The current number of correctable memory errors is reported in the variable cpqHeCorrMemTota… | ||
| 1.3.6.1.4.1.232.6002 | NodecpqHe2CorrectableMemoryLogDisabled | Correctable memory error tracking disabled. The frequency of errors is so high that the error tracking logic has been temporarily disabled. The cpqHeCorrMemLog… | ||
| 1.3.6.1.4.1.232.6003 | NodecpqHeThermalTempFailed | The temperature status has been set to failed. The system will be shutdown due to this thermal condition. | ||
| 1.3.6.1.4.1.232.6004 | NodecpqHeThermalTempDegraded | The temperature status has been set to degraded. The server's temperature is outside of the normal operating range. The server will be shutdown if the cpqHeThe… | ||
| 1.3.6.1.4.1.232.6005 | NodecpqHeThermalTempOk | The temperature status has been set to ok. The server's temperature has returned to the normal operating range. | ||
| 1.3.6.1.4.1.232.6006 | NodecpqHeThermalSystemFanFailed | The system fan status has been set to failed. A required system fan is not operating normally. The system will be shutdown if the cpqHeThermalDegradedAction va… | ||
| 1.3.6.1.4.1.232.6007 | NodecpqHeThermalSystemFanDegraded | The system fan status has been set to degraded. An optional system fan is not operating normally. | ||
| 1.3.6.1.4.1.232.6008 | NodecpqHeThermalSystemFanOk | The system fan status has been set to ok. Any previously non-operational system fans have returned to normal operation. | ||
| 1.3.6.1.4.1.232.6009 | NodecpqHeThermalCpuFanFailed | The CPU fan status has been set to failed. A processor fan is not operating normally. The server will be shutdown. | ||
| 1.3.6.1.4.1.232.6010 | NodecpqHeThermalCpuFanOk | The CPU fan status has been set to ok. Any previously non-operational processor fans have returned to normal operation. | ||
| 1.3.6.1.4.1.232.6011 | NodecpqHeAsrConfirmation | The server is operational again. The server has previously been shutdown by the Automatic Server Recovery (ASR) feature and has just become operational again. | ||
| 1.3.6.1.4.1.232.6012 | NodecpqHeThermalConfirmation | The server is operational again. The server has previously been shutdown due to a thermal anomaly on the server and has just become operational again. | ||
| 1.3.6.1.4.1.232.6013 | NodecpqHePostError | One or more POST errors occurred. Power On Self-Test (POST) errors occur during the server restart process. | ||
| 1.3.6.1.4.1.232.6014 | NodecpqHeFltTolPwrSupplyDegraded | The fault tolerant power supply sub-system condition has been set to degraded. | ||
| 1.3.6.1.4.1.232.6015 | NodecpqHe3CorrectableMemoryError | A correctable memory error occurred. The error has been corrected. The current number of correctable memory errors is reported in the variable cpqHeCorrMemTota… | ||
| 1.3.6.1.4.1.232.6016 | NodecpqHe3CorrectableMemoryLogDisabled | Correctable memory error tracking disabled. The frequency of errors is so high that the error tracking logic has been temporarily disabled. The cpqHeCorrMemLog… | ||
| 1.3.6.1.4.1.232.6017 | NodecpqHe3ThermalTempFailed | The temperature status has been set to failed. The system will be shutdown due to this thermal condition. | ||
| 1.3.6.1.4.1.232.6018 | NodecpqHe3ThermalTempDegraded | The temperature status has been set to degraded. The server's temperature is outside of the normal operating range. The server will be shutdown if the cpqHeThe… | ||
| 1.3.6.1.4.1.232.6019 | NodecpqHe3ThermalTempOk | The temperature status has been set to ok. The server's temperature has returned to the normal operating range. | ||
| 1.3.6.1.4.1.232.6020 | NodecpqHe3ThermalSystemFanFailed | The system fan status has been set to failed. A required system fan is not operating normally. The system will be shutdown if the cpqHeThermalDegradedAction va… | ||
| 1.3.6.1.4.1.232.6021 | NodecpqHe3ThermalSystemFanDegraded | The system fan status has been set to degraded. An optional system fan is not operating normally. | ||
| 1.3.6.1.4.1.232.6022 | NodecpqHe3ThermalSystemFanOk | The system fan status has been set to ok. Any previously non-operational system fans have returned to normal operation. | ||
| 1.3.6.1.4.1.232.6023 | NodecpqHe3ThermalCpuFanFailed | The CPU fan status has been set to failed. A processor fan is not operating normally. The server will be shutdown. | ||
| 1.3.6.1.4.1.232.6024 | NodecpqHe3ThermalCpuFanOk | The CPU fan status has been set to ok. Any previously non-operational processor fans have returned to normal operation. | ||
| 1.3.6.1.4.1.232.6025 | NodecpqHe3AsrConfirmation | The server is operational again. The server has previously been shutdown by the Automatic Server Recovery (ASR) feature and has just become operational again. | ||
| 1.3.6.1.4.1.232.6026 | NodecpqHe3ThermalConfirmation | The server is operational again. The server has previously been shutdown due to a thermal anomaly on the server and has just become operational again. | ||
| 1.3.6.1.4.1.232.6027 | NodecpqHe3PostError | One or more POST/UEFI errors occurred. Power On Self-Test (POST) errors occur during the server restart process. UEFI errors occur during server boot time and … | ||
| 1.3.6.1.4.1.232.6028 | NodecpqHe3FltTolPwrSupplyDegraded | The fault tolerant power supply sub-system condition has been set to degraded. | ||
| 1.3.6.1.4.1.232.6029 | NodecpqHe3CorrMemReplaceMemModule | A correctable memory log entry indicates a memory module needs to be replaced. The errors have been corrected, but the memory module should be replaced. The er… | ||
| 1.3.6.1.4.1.232.6030 | NodecpqHe3FltTolPowerSupplyDegraded | The fault tolerant power supply condition has been set to degraded for the specified chassis and bay location. | ||
| 1.3.6.1.4.1.232.6031 | NodecpqHe3FltTolPowerSupplyFailed | The fault tolerant power supply condition has been set to failed for the specified chassis and bay location. | ||
| 1.3.6.1.4.1.232.6032 | NodecpqHe3FltTolPowerRedundancyLost | The Fault Tolerant Power Supplies have lost redundancy for the specified chassis. | ||
| 1.3.6.1.4.1.232.6033 | NodecpqHe3FltTolPowerSupplyInserted | A Fault Tolerant Power Supply has been inserted into the specified chassis and bay location. | ||
| 1.3.6.1.4.1.232.6034 | NodecpqHe3FltTolPowerSupplyRemoved | A Fault Tolerant Power Supply has been removed from the specified chassis and bay location. | ||
| 1.3.6.1.4.1.232.6035 | NodecpqHe3FltTolFanDegraded | The Fault Tolerant Fan condition has been set to degraded for the specified chassis and fan. | ||
| 1.3.6.1.4.1.232.6036 | NodecpqHe3FltTolFanFailed | The Fault Tolerant Fan condition has been set to failed for the specified chassis and fan. | ||
| 1.3.6.1.4.1.232.6037 | NodecpqHe3FltTolFanRedundancyLost | The Fault Tolerant Fans have lost redundancy for the specified chassis. | ||
| 1.3.6.1.4.1.232.6038 | NodecpqHe3FltTolFanInserted | A Fault Tolerant Fan has been inserted into the specified chassis and fan location. | ||
| 1.3.6.1.4.1.232.6039 | NodecpqHe3FltTolFanRemoved | A Fault Tolerant Fan has been removed from the specified chassis and fan location. | ||
| 1.3.6.1.4.1.232.6040 | NodecpqHe3TemperatureFailed | The temperature status has been set to failed in the specified chassis and location. The system will be shutdown due to this condition. | ||
| 1.3.6.1.4.1.232.6041 | NodecpqHe3TemperatureDegraded | The temperature status has been set to degraded in the specified chassis and location. The server's temperature is outside of the normal operating range. The s… | ||
| 1.3.6.1.4.1.232.6042 | NodecpqHe3TemperatureOk | The temperature status has been set to ok in the specified chassis and location. The server's temperature has returned to the normal operating range. | ||
| 1.3.6.1.4.1.232.6043 | NodecpqHe3PowerConverterDegraded | The DC-DC Power Converter condition has been set to degraded for the specified chassis, slot and socket. | ||
| 1.3.6.1.4.1.232.6044 | NodecpqHe3PowerConverterFailed | The DC-DC Power Converter condition has been set to failed for the specified chassis, slot and socket. | ||
| 1.3.6.1.4.1.232.6045 | NodecpqHe3PowerConverterRedundancyLost | The DC-DC Power Converters have lost redundancy for the specified chassis. | ||
| 1.3.6.1.4.1.232.6046 | NodecpqHe3CacheAccelParityError | A cache accelerator parity error indicates a cache module needs to be replaced. The error information is reported in the variable cpqHeEventLogErrorDesc. | ||
| 1.3.6.1.4.1.232.6047 | NodecpqHeResilientMemOnlineSpareEngaged | Advanced Memory Protection Online Spare Engaged. The Advanced Memory Protection subsystem has detected a memory fault. The Online Spare Memory has been activat… | ||
| 1.3.6.1.4.1.232.6048 | NodecpqHe4FltTolPowerSupplyOk | The fault tolerant power supply condition has been set back to the OK state for the specified chassis and bay location. | ||
| 1.3.6.1.4.1.232.6049 | NodecpqHe4FltTolPowerSupplyDegraded | The fault tolerant power supply condition has been set to degraded for the specified chassis and bay location. | ||
| 1.3.6.1.4.1.232.6050 | NodecpqHe4FltTolPowerSupplyFailed | The fault tolerant power supply condition has been set to failed for the specified chassis and bay location. | ||
| 1.3.6.1.4.1.232.6051 | NodecpqHeResilientMemMirroredMemoryEngaged | Advanced Memory Protection Mirrored Memory Engaged. The Advanced Memory Protection subsystem has detected a memory fault. Mirrored Memory has been activated. U… | ||
| 1.3.6.1.4.1.232.6052 | NodecpqHeResilientAdvancedECCMemoryEngaged | Advanced Memory Protection Advanced ECC Memory Engaged. The Advanced Memory Protection subsystem has detected a memory fault. Advanced ECC has been activated. … | ||
| 1.3.6.1.4.1.232.6053 | NodecpqHeResilientMemXorMemoryEngaged | Advanced Memory Protection XOR Engine Memory Engaged. The Advanced Memory Protection subsystem has detected a memory fault. The XOR engine has been activated. … | ||
| 1.3.6.1.4.1.232.6054 | NodecpqHe3FltTolPowerRedundancyRestored | The Fault Tolerant Power Supplies have returned to a redundant state for the specified chassis. | ||
| 1.3.6.1.4.1.232.6055 | NodecpqHe3FltTolFanRedundancyRestored | The Fault Tolerant Fans have returned to a redundant state for the specified chassis. | ||
| 1.3.6.1.4.1.232.6056 | NodecpqHe4CorrMemReplaceMemModule | Corrected Memory Errors Detected The errors have been corrected, but the memory module should be replaced. | ||
| 1.3.6.1.4.1.232.6057 | NodecpqHeResMemBoardRemoved | Memory board or cartridge removed. An Advanced Memory Protection sub-system board or cartridge has been removed from the system. User Action: Ensure the board … | ||
| 1.3.6.1.4.1.232.6058 | NodecpqHeResMemBoardInserted | Memory board or cartridge inserted. An Advanced Memory Protection sub-system board or cartridge has been inserted into the system. User Action: None. | ||
| 1.3.6.1.4.1.232.6059 | NodecpqHeResMemBoardBusError | Memory board or cartridge bus error detected. An Advanced Memory Protection sub-system board or cartridge bus error has been detected. User Action: Replace the… | ||
| 1.3.6.1.4.1.232.6060 | NodecpqHeEventOccurred | An event has occurred. User Action: None. | ||
| 1.3.6.1.4.1.232.6061 | NodecpqHeManagementProcInReset | The Management processor is currently in reset The management processor is currently in the process of being reset because of a firmware update or some other e… | ||
| 1.3.6.1.4.1.232.6062 | NodecpqHeManagementProcReady | The Management processor is ready The management processor has successfully reset and is now available again. User action: None | ||
| 1.3.6.1.4.1.232.6063 | NodecpqHeManagementProcFailedReset | The Management processor failed reset The management processor was not successfully reset and is not operational. User action: Reset the management procesessor… | ||
| 1.3.6.1.4.1.232.6064 | NodecpqHe5CorrMemReplaceMemModule | Corrected \ uncorrected Memory Errors Detected The errors have been corrected, but the memory module should be replaced. Value 0 for CPU means memory is not Pr… | ||
| 1.3.6.1.4.1.232.6065 | NodecpqHe5ResMemBoardRemoved | Memory board or cartridge or riser removed. An Advanced Memory Protection sub-system board or cartridge or riser has been removed from the system. Value 0 for … | ||
| 1.3.6.1.4.1.232.6066 | NodecpqHe5ResMemBoardInserted | Memory board or cartridge or riser inserted. An Advanced Memory Protection sub-system board or cartridge or riser Has been inserted into the system. Value 0 fo… | ||
| 1.3.6.1.4.1.232.6067 | NodecpqHe5ResMemBoardBusError | Memory board or cartridge or Riser bus error detected. An Advanced Memory Protection sub-system board or cartridge or Riser bus error has been detected. Value … | ||
| 1.3.6.1.4.1.232.6068 | NodecpqHeResilientMemLockStepMemoryEngaged | Advanced Memory Protection LockStep Engine Memory Engaged. The Advanced Memory Protection subsystem has detected a memory fault. The LockStep engine has been a… | ||
| 1.3.6.1.4.1.232.6069 | NodecpqHe4FltTolPowerSupplyACpowerloss | The fault tolerant power supply AC power loss for the specified chassis and bay location. | ||
| 1.3.6.1.4.1.232.6070 | NodecpqHeSysBatteryFailed | The system battery has either failed or met a predictive failure condition for the specified chassis and index location. | ||
| 1.3.6.1.4.1.232.6071 | NodecpqHeSysBatteryRemoved | The system battery condition has removed for the specified chassis and index location. | ||
| 1.3.6.1.4.1.232.6072 | NodecpqHeSysPwrAllocationNotOptimized | Error in setting server power throttle. Server enclosure power request has increased. Server power allocation is not optimized. | ||
| 1.3.6.1.4.1.232.6073 | NodecpqHeSysPwrOnDenied | One of the Field Replacement Units(FRU) is not allowing the system to power on. | ||
| 1.3.6.1.4.1.232.6074 | NodecpqHePowerFailureError | This trap signifies a device connected to or embedded on the system board has an error. | ||
| 1.3.6.1.4.1.232.6075 | NodecpqHeInterlockFailureError | This trap signifies a device missing or improperly seated on the system board. | ||
| 1.3.6.1.4.1.232.6076 | NodecpqHeNvdimmBackupError | NVDIMM Error - Backup Error detected. Persistent data backup failed and data is not available. | ||
| 1.3.6.1.4.1.232.6077 | NodecpqHeNvdimmRestoreError | NVDIMM Error - Restore Error detected. Persistent data restore failed and data is not available. | ||
| 1.3.6.1.4.1.232.6078 | NodecpqHeNvdimmUncorrectableMemoryError | NVDIMM Error -Uncorrectable Memory Error - This NVDIMM will not be available to the operating system. | ||
| 1.3.6.1.4.1.232.6079 | NodecpqHeNvdimmBackupPowerError | NVDIMM Error - Backup Power Error. Backup power is not available and a future backup is not possible. | ||
| 1.3.6.1.4.1.232.6080 | NodecpqHeNvdimmNVDIMMControllerError | NVDIMM Error - NVDIMM Controller Error. An error was found with the NVDIMM controller. The OS will not use the NVDIMM. | ||
| 1.3.6.1.4.1.232.6081 | NodecpqHeNvdimmEraseError | NVDIMM Error - Erase Error. NVDIMM could not be erased and future backups are not possible. | ||
| 1.3.6.1.4.1.232.6082 | NodecpqHeNvdimmArmingError | NVDIMM Error - Arming Error. NVDIMM could not be armed and future backups are not possible. | ||
| 1.3.6.1.4.1.232.6083 | NodecpqHeNvdimmSanitizationOk | This NVDIMM-N was selected for Sanitizing/Erasing. All data saved in the NVDIMM has been erased. | ||
| 1.3.6.1.4.1.232.6084 | NodecpqHeNvdimmSanitizationError | NVDIMM Error - Sanitization Error. This NVDIMM-N was selected for Sanitizing/Erasing, but this process was not successful. | ||
| 1.3.6.1.4.1.232.6085 | NodecpqHeNvdimmControllerFirmwareError | NVDIMM Error - Controller Firmware Error. The controller firmware has been corrupted. The OS will not use the NVDIMM. | ||
| 1.3.6.1.4.1.232.6086 | NodecpqHeNvdimmErrorInterleaveOn | NVDIMM Error. NVDIMM received a memory initialization or uncorrectable error. All NVDIMMs on Processor are disabled. | ||
| 1.3.6.1.4.1.232.6087 | NodecpqHeNvdimmInterleaveOff | NVDIMM Error - NVDIMM received a memory initialization or uncorrectable error. NVDIMM has been disabled. | ||
| 1.3.6.1.4.1.232.6088 | NodecpqHeNvdimmEventNotifyError | NVDIMM Error - Unable to set event notification for this NVDIMM. | ||
| 1.3.6.1.4.1.232.6089 | NodecpqHeNvdimmPersistencyLost | NVDIMM Error - Persistency Lost. NVDIMM Persistency is lost and future data backup is not available. | ||
| 1.3.6.1.4.1.232.6090 | NodecpqHeNvdimmPersistencyRestored | NVDIMM - Persistency Restored. NVDIMM Persistency is restored and future data backup is available. | ||
| 1.3.6.1.4.1.232.6091 | NodecpqHeNvdimmLifecycleWarning | NVDIMM Lifecycle Warning. NVDIMM lifetime has reached. | ||
| 1.3.6.1.4.1.232.6092 | NodecpqHeNvdimmLogicalNvdimmError | One or more Logical NVDIMM errors occurred. Details of the Logical NVDIMM error messages can be found in Integrated Management Log | ||
| 1.3.6.1.4.1.232.6093 | NodecpqHeNvdimmConfigurationError | One or more NVDIMM Configuration errors occurred. Details of the NVDIMM Configuration error messages can be found in Integrated Management Log | ||
| 1.3.6.1.4.1.232.6094 | NodecpqHeNvdimmBatteryNotChargedwithWait | Smart battery is not charged sufficiently to support the NVDIMMs installed in the system. | ||
| 1.3.6.1.4.1.232.6095 | NodecpqHeNvdimmBatteryNotChargedwithNoWait | Smart battery is not charged sufficiently to support the NVDIMMs installed in the system. | ||
| 1.3.6.1.4.1.232.6096 | NodecpqHeDimmMemoryMapChanged | Uncorrectable Memory Error - The failed memory module could not be determined. | ||
| 1.3.6.1.4.1.232.6097 | NodecpqHeNvdimmPersistantMemoryAddressError | Persistent Memory Address Range Scrub has detected an error. | ||
| 1.3.6.1.4.1.232.6098 | NodecpqHeNvdimmInitializationError | NVDIMM(s) cannot be initialized due to internal error. | ||
| 1.3.6.1.4.1.232.6099 | NodecpqHePwrSupplyError | System Power Supply Error. | ||
| 1.3.6.1.4.1.232.6100 | NodecpqHePwrSupplyErrorRepaired | System Power Supply Error Repaired. | ||
| 1.3.6.1.4.1.232.6101 | NodecpqHeBbuError | Battery Backup Unit Error. | ||
| 1.3.6.1.4.1.232.6102 | NodecpqHeBbuErrorRepaired | Battery Backup Unit Error Repaired. | ||
| 1.3.6.1.4.1.232.6103 | NodecpqHeNoPowerSupplyDetected | Power Supply or Power Backplane Detection Error. | ||
| 1.3.6.1.4.1.232.6104 | NodecpqHePowerProtectionFault | System Board Power Protection Fault. | ||
| 1.3.6.1.4.1.232.6105 | NodecpqHePowerFuseDegraded | A degraded power event has been detected and the server system board should be replaced. | ||
| 1.3.6.1.4.1.232.6106 | NodecpqHeTPMSecureEraseFailed | Trusted Platform Module has failed the Secure Erase Operation. | ||
| 1.3.6.1.4.1.232.6107 | NodecpqHeSPISecureEraseFailed | One-button secure erase of system firmware configuration data has failed | ||
| 1.3.6.1.4.1.232.6108 | NodecpqHePMMSecureEraseFailed | Secure Erase of HPE Persistent Memory has failed. | ||
| 1.3.6.1.4.1.232.6109 | NodecpqHeNANDSecureEraseFailed | Secure Erase of the management processor's embedded media device has Failed. | ||
| 1.3.6.1.4.1.232.6110 | NodecpqHeSedPassphrasefail | Device Encryption Error. Enabling or Disabling encryption/modifying passphrase failed. | ||
| 1.3.6.1.4.1.232.6111 | NodecpqHeSedUnlockfail | Device Encryption Error - Three incorrect attempts were made to unlock Processor and DIMM. The device will be locked until the next power cycle. | ||
| 1.3.6.1.4.1.232.6112 | NodecpqHePMMHealthFailure | The HPE Persistent Memory Module has experienced an issue and is not longer operational or resilient. | ||
| 1.3.6.1.4.1.232.6113 | NodecpqHePMMLessUsageRemainingAlert | HPE Persistent Memory Percentage Remaining Alert. The HPE Persistent Memory Module has less usage remaining. Future errors on this HPE Persistent Memory Module… | ||
| 1.3.6.1.4.1.232.6114 | NodecpqHePMMConfigErr | One or more PMM Configuration errors occurred. Details of the PMM Configuration error messages can be found in Integrated Management Log | ||
| 1.3.6.1.4.1.232.6115 | NodecpqHePMMShutdownWarning | HPE Persistent Memory Health Warning. The HPE Persistent Memory Module reported an unsafe shutdown. | ||
| 1.3.6.1.4.1.232.6116 | NodecpqHePMMCorrErrThreshold | Correctable Memory Error Threshold Exceeded | ||
| 1.3.6.1.4.1.232.6117 | NodecpqHePMMBootStatusRegWarning | HPE Persistent Memory Error - The HPE Memory Module reported a failure on the previous boot | ||
| 1.3.6.1.4.1.232.6118 | NodecpqHeInletAmbientPreCautionThresAlert | Inlet Ambient temperature sensor user defined Pre-Caution threshold level exceeded. Air baffle or blank is missing or not installed properly and causing a disr… | ||
| 1.3.6.1.4.1.232.6119 | NodecpqHeCoolingModuleDegraded | The Cooling Module condition has been set to degraded for the specified chassis . | ||
| 1.3.6.1.4.1.232.6120 | NodecpqHeCoolingModuleFailed | The Cooling Module condition has been set to failed for the specified chassis. | ||
| 1.3.6.1.4.1.232.6121 | NodecpqHeCoolingModuleRedundancyLost | The Cooling Modules have lost redundancy for the specified chassis. | ||
| 1.3.6.1.4.1.232.6122 | NodecpqHeCoolingModuleRedundancyRestored | The Cooling Modules have returned to a redundant state for the specified chassis. |