MIB Viewer

DASAN-NOTIFICATION

453 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.6296.0.1NotificationportInstalledcurrentportI0nstalled trap send when portInstallStatus is enabled.
1.3.6.1.4.1.6296.0.2NotificationportRemovedcurrentportInstalled trap send when portInstallStatus is disabled.
1.3.6.1.4.1.6296.0.3NotificationpowerOkcurrentPower status OK trap when powerStatus change from disable to enable.
1.3.6.1.4.1.6296.0.4NotificationpowerFailcurrentPower status fail trap when powerStatus change from enable to disable.
1.3.6.1.4.1.6296.0.5NotificationfanOkcurrentFan status OK trap when fanStatus change from disable to enable.
1.3.6.1.4.1.6296.0.6NotificationfanFailcurrentFan status fail trap when fanStatus change from enable to disable.
1.3.6.1.4.1.6296.0.7NotificationpowerInstalledcurrentPower Installed trap when power was installed.
1.3.6.1.4.1.6296.0.8NotificationpowerRemovedcurrentPower removed trap when power was removed.
1.3.6.1.4.1.6296.0.9NotificationfanInstalledcurrentFan Installed trap when fan was installed.
1.3.6.1.4.1.6296.0.10NotificationfanRemovedcurrentFan removed trap when fan was removed.
1.3.6.1.4.1.6296.0.11NotificationbcastOvercurrentBroadcast packet over trap when Rx broadcast packet is over the given limit.
1.3.6.1.4.1.6296.0.12NotificationcpuLoadOverThresholdcurrentThe cpuLoadOverThreshold trap is sent when cpuLoad is over the given limit.
1.3.6.1.4.1.6296.0.13NotificationcpuLoadFallThresholdcurrentThe cpuLoadfallThreshold trap is sent when cpuLoad fall under the given limit.
1.3.6.1.4.1.6296.0.14NotificationdhcpLeaseShortagecurrentDHCP User IP pool shortage when User's DHCPDISCOVER message arrive.
1.3.6.1.4.1.6296.0.15NotificationportOverThresholdcurrentPort traffic over HighThreshold trap when port traffic is over the given limit.
1.3.6.1.4.1.6296.0.16NotificationportFallThresholdcurrentPort traffic fall under HighThreshold trap when port traffic falls below the given limit.
1.3.6.1.4.1.6296.0.17NotificationtemperatureOverThresholdcurrentTemperatureOverThreshold Trap is sent when temperature is over the certain threshold.
1.3.6.1.4.1.6296.0.18NotificationsystemRestartcurrentSystemRestart Trap is sent when system is restarted by user. sleAutoResetBootReason is only used for auto-reset
1.3.6.1.4.1.6296.0.19NotificationmfgdBlockedcurrentmfgdblocked Trap is sent when a certain mac address is denied by mac-flood-guard mechanism.
1.3.6.1.4.1.6296.0.20NotificationmfgdReleasedcurrentmfgdReleased Trap is sent when a certain mac address is permitted again by mac-flood-guard mechanism.
1.3.6.1.4.1.6296.0.21NotificationipConflictcurrentipConflict Trap is sent when a certain IP address is shared among different users.
1.3.6.1.4.1.6296.0.22NotificationdhcpIllegalEntrycurrentdhcpIllegalEntry trap is sent when illegal dhcp user is found.
1.3.6.1.4.1.6296.0.23NotificationoptionModuleInstalledcurrentoptionModuleInstalled Trap is sent when option Module was installed.
1.3.6.1.4.1.6296.0.24NotificationoptionModuleRemovedcurrentoptionModuleRemoved Trap is sent when option Module was removed.
1.3.6.1.4.1.6296.0.25NotificationmemoryOverThresholdcurrentMemoryOverThreshold trap is sent when used memory size is over the given limit and free memory size falls below the given limit.
1.3.6.1.4.1.6296.0.26NotificationmemoryFallThresholdcurrentMemoryFallThreshold trap is sent when free memory size is over the given limit.
1.3.6.1.4.1.6296.0.27NotificationslotInstalledcurrentslotInstalledTrap Trap is sent when Board was installed.
1.3.6.1.4.1.6296.0.28NotificationslotRemovedcurrentslotRemovedTrap Trap is sent when Board was removed.
1.3.6.1.4.1.6296.0.29NotificationslotStateChangecurrentslotStateChangeTrap Trap is sent when Board State change.
1.3.6.1.4.1.6296.0.30NotificationportCRCOverThresholdcurrentportCRCOverThreshold Trap is sent when the CRC count of port over threshold.
1.3.6.1.4.1.6296.0.31NotificationportCRCFallThresholdcurrentportCRCOverThreshold Trap is sent when the CRC count of port fall threshold.
1.3.6.1.4.1.6296.0.32NotificationtemperatureHighOverThresholdcurrentThe temperatureHighOverThreshold Trap is sent when temperature is over the high-threshold.
1.3.6.1.4.1.6296.0.33NotificationtemperatureHighFallThresholdcurrentThe temperatureHighFallThreshold Trap is sent when temperature fall the high-threshold.
1.3.6.1.4.1.6296.0.34NotificationtemperatureLowOverThresholdcurrentThe temperatureLowOverThreshold Trap is sent when 1st temperature is over the low-threshold.
1.3.6.1.4.1.6296.0.35NotificationtemperatureLowFallThresholdcurrentThe temperatureLowFallThreshold Trap is sent when temperature fall under the low-threshold.
1.3.6.1.4.1.6296.0.36NotificationuserLogIncurrentThe user-login trap is sent when user login.
1.3.6.1.4.1.6296.0.37NotificationuserLogOutcurrentThe user-logout trap is sent when user logout.
1.3.6.1.4.1.6296.0.38NotificationrestoreFactorycurrentThe restoreFactory trap is sent when user initialize as factory defaults.
1.3.6.1.4.1.6296.0.39NotificationcpuLoadHighOverThresholdcurrentThe cpuloadHighOverThreshold Trap is sent when temperature is over the high-threshold.
1.3.6.1.4.1.6296.0.40NotificationcpuLoadHighFallThresholdcurrentThe cpuloadHighFallThreshold Trap is sent when temperature fall the high-threshold.
1.3.6.1.4.1.6296.0.41NotificationcpuLoadLowOverThresholdcurrentThe cpuloadLowOverThreshold Trap is sent when 1st temperature is over the low-threshold.
1.3.6.1.4.1.6296.0.42NotificationcpuLoadLowFallThresholdcurrentThe cpuloadLowFallThreshold Trap is sent when temperature fall under the low-threshold.
1.3.6.1.4.1.6296.0.44NotificationdsSystemUpgradeChangedcurrentSystem NOS Upgrade status
1.3.6.1.4.1.6296.0.45NotificationinterfaceOperDowncurrentThis trap indicates the interface oper down.
1.3.6.1.4.1.6296.0.46NotificationinterfaceOperUpcurrentThis trap indicates the interface poer up.
1.3.6.1.4.1.6296.0.47NotificationmacLearnOverMaxcurrentThis trap indicates the count of L2 mac is over the max.
1.3.6.1.4.1.6296.0.48NotificationmacLearnOverMaxClearedcurrentThis trap indicates the count of L2 mac is over the max is cleared
1.3.6.1.4.1.6296.0.49NotificationinterfaceMacLearnOverMaxcurrentThis trap indicates the count of interface's L2 mac is over the max.
1.3.6.1.4.1.6296.0.50NotificationinterfaceMacLearnOverMaxClearedcurrentThis trap indicates the count of interface's L2 mac is over the max is cleared
1.3.6.1.4.1.6296.0.51NotificationadslAtucPerfLofsThreshcurrentLoss of Framing threshold reached(ATUC).
1.3.6.1.4.1.6296.0.52NotificationadslAtucPerfLossThreshcurrentLoss of signal threshold reached(ATUC).
1.3.6.1.4.1.6296.0.53NotificationadslAtucPerfLprsThreshcurrentLoss of power threshold reached (ATUC).
1.3.6.1.4.1.6296.0.54NotificationadslAtucPerfESsThreshcurrentErrored Seconds threshold reached (ATUC).
1.3.6.1.4.1.6296.0.55NotificationadslAtucRateChangecurrentChanged atuc rate.
1.3.6.1.4.1.6296.0.56NotificationadslAtucPerfLolsThreshcurrentLoss of Link threshold reached (ATUC).
1.3.6.1.4.1.6296.0.61NotificationadslAturPerfLofsThreshcurrentLoss of Framing threshold reached(ATUR).
1.3.6.1.4.1.6296.0.62NotificationadslAturPerfLossThreshcurrentLoss of signal threshold reached(ATUR).
1.3.6.1.4.1.6296.0.63NotificationadslAturPerfLprsThreshcurrentLoss of power threshold reached (ATUR).
1.3.6.1.4.1.6296.0.64NotificationadslAturPerfESsThreshcurrentErrored Seconds threshold reached (ATUR).
1.3.6.1.4.1.6296.0.65NotificationvdslCPEChangeInfoTrapcurrentTrap is sent with CPE Serial No., Mac Address of CPE, after CPE serial change.
1.3.6.1.4.1.6296.0.66NotificationvdslArulePacketDropTrapcurrentPacket Dropped by arule .
1.3.6.1.4.1.6296.0.69NotificationportMododuleInstallcurrentport module install
1.3.6.1.4.1.6296.0.70NotificationportMododuleRemovecurrentport module remove
1.3.6.1.4.1.6296.0.71NotificationcfgdBlockedcurrentCfgdblocked Trap is sent when a certain port is blocked by cpu-flood-guard mechanism.
1.3.6.1.4.1.6296.0.72NotificationcfgdReleasedcurrentCfgdReleased Trap is sent when a certain port is non-blocked by cpu-flood-guard mechanism.
1.3.6.1.4.1.6296.0.73NotificationcfgdOverThresholdcurrentCfgdReleased Trap is sent when a certain port is over threshold by cpu-flood-guard mechanism.
1.3.6.1.4.1.6296.0.74NotificationcfgdUnderThresholdcurrentCfgdReleased Trap is sent when a certain port is under threshold by cpu-flood-guard mechanism.
1.3.6.1.4.1.6296.0.75NotificationsfgdBlockedcurrentSfgdblocked Trap is sent when a certain port is blocked by system-flood-guard mechanism.
1.3.6.1.4.1.6296.0.76NotificationsfgdReleasedcurrentSfgdReleased Trap is sent when a certain port is non-blocked by system-flood-guard mechanism.
1.3.6.1.4.1.6296.0.77NotificationsfgdOverThresholdcurrentSfgdReleased Trap is sent when a certain port is over threshold by system-flood-guard mechanism.
1.3.6.1.4.1.6296.0.78NotificationsfgdUnderThresholdcurrentSfgdReleased Trap is sent when a certain port is under threshold by system-flood-guard mechanism.
1.3.6.1.4.1.6296.0.79NotificationppsControlBlockedcurrentPpsControlblocked Trap is sent when a certain port is blocked by PPS-Control mechanism.
1.3.6.1.4.1.6296.0.80NotificationppsControlReleasedcurrentPpsControlReleased Trap is sent when a certain port is non-blocked by PPS-Control mechanism.
1.3.6.1.4.1.6296.0.81NotificationppsControlOverThresholdcurrentPpsControlReleased Trap is sent when a certain port is over threshold by PPS-Control mechanism.
1.3.6.1.4.1.6296.0.82NotificationppsControlUnderThresholdcurrentPpsControlReleased Trap is sent when a certain port is under threshold by PPS-Control mechanism.
1.3.6.1.4.1.6296.0.83NotificationnosRemoteUpgradeRequestcurrentThis trap indicates that the system received nos-remote-upgrade command.
1.3.6.1.4.1.6296.0.84NotificationnosRemoteUpgradeSuccesscurrentThis trap indicates that the NOS succeeded to upgrade NOS.
1.3.6.1.4.1.6296.0.85NotificationnosRemoteUpgradeFailAbortcurrentThis trap indicates that the system failed to upgrade NOS by user interrupt
1.3.6.1.4.1.6296.0.86NotificationnosRemoteUpgradeFailHeaderErrorcurrentThis trap indicates that the system failed to upgrade NOS, for NOS header-error.
1.3.6.1.4.1.6296.0.87NotificationnosRemoteUpgradeFailDownloadErrorcurrentThis trap indicates that the system failed to upgrade NOS, for NOS checksum-error
1.3.6.1.4.1.6296.0.88NotificationnosRemoteUpgradeFailFlashErrorcurrentThis trap indicates that the system failed to upgrade NOS, for flash operation
1.3.6.1.4.1.6296.0.89NotificationnosRemoteUpgradeStartcurrentThis trap indicates that the upgrade NOS process was started.
1.3.6.1.4.1.6296.0.90NotificationsystemDyingGaspcurrentThis trap indicates that Dying-gasp for power fault.
1.3.6.1.4.1.6296.0.91NotificationattackGuardBlockcurrentThis trap indicates that some port is blocked by attack-guard.
1.3.6.1.4.1.6296.0.92NotificationattackGuardUnBlockcurrentThis trap indicates that some port is unblocked by attack-guard.
1.3.6.1.4.1.6296.0.93NotificationfanPeriodicFaultcurrentThis trap indicates the fan status is fault in some period.
1.3.6.1.4.1.6296.0.94NotificationremoteOamDyingGaspcurrentThis trap indicates the remote oam entity is in dying-gasp .
1.3.6.1.4.1.6296.0.95NotificationremoteOamDyingGaspRestorationcurrentThis trap indicates the remote oam entity is restored.
1.3.6.1.4.1.6296.0.96NotificationarpInspectInvalidcurrentThis trap indicates the ARP inspection is invalided.
1.3.6.1.4.1.6296.0.97NotificationsystemSwitchovercurrentThis trap indicates the system is switchover.
1.3.6.1.4.1.6296.0.98NotificationboardChangeStatecurrentThis trap indicates the board state is changed.
1.3.6.1.4.1.6296.0.99NotificationredConfigurationMisMatchcurrentConfigurations of Active and Standby SFU are different.
1.3.6.1.4.1.6296.0.105NotificationclockModuleInstalledcurrentclockModuleInstalled trap send when sleClockModuleInstallStatus is installed.
1.3.6.1.4.1.6296.0.106NotificationclockModuleRemovedcurrentclockModuleRemoved trap send when sleClockModuleInstallStatus is removed.
1.3.6.1.4.1.6296.0.107NotificationclockModuleInitOkcurrentclockModuleInitOk trap send when sleClockModuleInitStatus is ok.
1.3.6.1.4.1.6296.0.108NotificationclockModuleInitFailcurrentclockModuleInitFail trap send when sleClockModuleInitStatus is failure.
1.3.6.1.4.1.6296.0.109NotificationinterfaceAdminUpcurrentThis trap indicates the interface admin up.
1.3.6.1.4.1.6296.0.110NotificationinterfaceAdminDowncurrentThis trap indicates the interface admin down.
1.3.6.1.4.1.6296.0.111NotificationpowerMonEventDetectedcurrentThis trap indicates the power monitoring detects voltage change of slot.
1.3.6.1.4.1.6296.0.112NotificationntpConnectionFailcurrentThis trap indicates the ntp connection is lost.
1.3.6.1.4.1.6296.0.113NotificationfanSpeedFallUnderThresholdcurrentThis trap indicates the fan speed is under the threshold.
1.3.6.1.4.1.6296.0.114NotificationfanSpeedRisingOverThresholdcurrentThis trap indicates the fan speed is over the threshold.
1.3.6.1.4.1.6296.0.115NotificationuserLoginFailcurrentThis trap indicates the user fail to login.
1.3.6.1.4.1.6296.0.116NotificationbfdSessionStateChangedcurrentThis trap indicates that BFD session state is changed.
1.3.6.1.4.1.6296.0.117NotificationclockModuleOPModeChangedcurrentThis trap indicate that slot Operation mode is changed.
1.3.6.1.4.1.6296.0.118NotificationclockModuleRefrencesChangedcurrentThis trap indicate that slot reference ntr is changed.
1.3.6.1.4.1.6296.0.119NotificationportOperUpcurrentThis trap indicate that port operation is up.
1.3.6.1.4.1.6296.0.120NotificationportOperDowncurrentThis trap indicate that port operation is down
1.3.6.1.4.1.6296.0.121NotificationportRxOverThresholdcurrentPort Rx traffic over HighThreshold trap when port traffic is over the given limit.
1.3.6.1.4.1.6296.0.122NotificationportRxFallThresholdcurrentPort Rx traffic fall under HighThreshold trap when port traffic falls below the given limit.
1.3.6.1.4.1.6296.0.123NotificationportTxOverThresholdcurrentPort Tx traffic over HighThreshold trap when port traffic is over the given limit.
1.3.6.1.4.1.6296.0.124NotificationportTxFallThresholdcurrentPort Tx traffic fall under HighThreshold trap when port traffic falls below the given limit.
1.3.6.1.4.1.6296.0.125NotificationclockModuleInSrcStatusChangedcurrentThis trap indicate that module status is changed.
1.3.6.1.4.1.6296.0.126NotificationclockModuleInSrcAISStatusChangedcurrentThis trap indicate that AIS status is changed.
1.3.6.1.4.1.6296.0.127NotificationclockModuleInSrcLoSStatusChagedcurrentThis trap indicate that LOS status is changed.
1.3.6.1.4.1.6296.0.128NotificationclockModuleInSrcLDSCStatuscurrentThis trap indicate that LDSC status is changed.
1.3.6.1.4.1.6296.0.129NotificationclockModuleInSrcNtrClockChangedcurrentThis trap indicate that NTR is changed.
1.3.6.1.4.1.6296.0.130NotificationreloadMateSFUcurrentThis trap indicate that reload mate SFU.
1.3.6.1.4.1.6296.0.131NotificationprocessDowncurrentThis trap indicate that certain process is crashed and restarted.
1.3.6.1.4.1.6296.0.132NotificationprocessTimeoutcurrentThis trap indicate that certain process is timeout.
1.3.6.1.4.1.6296.0.133NotificationsdcardInstalledcurrentThis trap indicate that SD card is installed.
1.3.6.1.4.1.6296.0.134NotificationsdcardRemovedcurrentThis trap indicate that SD card is removed.
1.3.6.1.4.1.6296.0.141NotificationbootedNonDefaultOScurrentThis trap indicate that the system started with non-default OS.
1.3.6.1.4.1.6296.0.142NotificationslotBootedNonDefaultOScurrentThis trap indicate that the IU card started with non-default OS.
1.3.6.1.4.1.6296.0.145NotificationcpuPpsOverThresholdcurrentThe PPS of cpu is over the threshold.
1.3.6.1.4.1.6296.0.146NotificationcpuPpsUnderThresholdcurrentThe PPS of cpu is under the threshold.
1.3.6.1.4.1.6296.0.147NotificationredundantPacketDetectedcurrentRedundant packets is detected.
1.3.6.1.4.1.6296.0.148NotificationredundantPacketDetectedClearedcurrentRedundant packets detection is cleared.
1.3.6.1.4.1.6296.0.151NotificationponLinkFaultcurrentONU reports a Link Fault via the flag in the 802.3ah OAM header.No further information about the fault is available..
1.3.6.1.4.1.6296.0.152NotificationponLoscurrentLoss of Signal is detected by the PHY device for OLT Network interface, and PON interfaces on the OLT and ONU.
1.3.6.1.4.1.6296.0.153NotificationponTransmitFailcurrentTransmitted output does not match input, as reported by EPON optics.
1.3.6.1.4.1.6296.0.154NotificationponTransmitDegradecurrentTransmitted output has a high error level, but not so high as to cause - Failure. Optionallyreported by EPON optical module.
1.3.6.1.4.1.6296.0.155NotificationponQueueOverflowcurrentOne of the queues for the link has dropped frames due to becoming full.
1.3.6.1.4.1.6296.0.156NotificationponMacLearningTableOverflowcurrentMAC address learning table is full, not in overwrite mode, and a new MAC address wasencountered.
1.3.6.1.4.1.6296.0.157NotificationponDuplicateMacRegistrationcurrentMPCP register request received for MAC that is registered and in-service.
1.3.6.1.4.1.6296.0.158NotificationponReportTimeoutcurrentONU does not respond to grants from the OLT.
1.3.6.1.4.1.6296.0.159NotificationponGateTimeoutcurrentExcessive interval between MPCP gates.
1.3.6.1.4.1.6296.0.160NotificationponOAMKeepaliveTimeoutcurrentOAM KeepaliveTimeout - OAM layer does not receive periodic messages from its peer.
1.3.6.1.4.1.6296.0.161NotificationponKeyExchangeFailurecurrentThe link peer has failed to generate a new key message, or to switch to the new key, in the timeallotted by the key exchange timer for this link. Encryption re…
1.3.6.1.4.1.6296.0.162NotificationponAutoNegotiationcurrentOLT Network port fails to auto-negotiate with the peer (if auto-negotiation feature is enabled).
1.3.6.1.4.1.6296.0.163NotificationponLinkLoopbackcurrentThe link is currently in the loopback state.
1.3.6.1.4.1.6296.0.164NotificationponStandardDyingGaspcurrentONU reports Dying Gasp via that bit in 802.3ah OAM header.
1.3.6.1.4.1.6296.0.165NotificationponPowerFailcurrentPower supply failure.
1.3.6.1.4.1.6296.0.166NotificationponTemperaturecurrentOperating temperature range exceeded.
1.3.6.1.4.1.6296.0.167NotificationponAuthenticationInformationUnavailablecurrentONU is configured to use external authentication device, and that device is not present.
1.3.6.1.4.1.6296.0.171NotificationponOctetsTransferredcurrentOctets Transferred.
1.3.6.1.4.1.6296.0.172NotificationponTotalFramesTransferredcurrentTotal frames transferred.
1.3.6.1.4.1.6296.0.173NotificationponUnicastFramesTransferredcurrentUnicast frames transferred.
1.3.6.1.4.1.6296.0.174NotificationponBroadcastFramesTransferredcurrentBroadcast frames transferred.
1.3.6.1.4.1.6296.0.175NotificationponMulticastFramesTransferredcurrentMulticast frames transferred.
1.3.6.1.4.1.6296.0.176NotificationponCRC32ErrorscurrentCRC-32 Errors.
1.3.6.1.4.1.6296.0.177NotificationponUndersizeFramescurrentUndersize Frames.
1.3.6.1.4.1.6296.0.178NotificationponOversizeFramescurrentOversize Frames.
1.3.6.1.4.1.6296.0.179NotificationponCollisionscurrentCollisions.
1.3.6.1.4.1.6296.0.180Notificationpon64OctetFramescurrent64 Octet Frames.
1.3.6.1.4.1.6296.0.181Notificationpon127OctetFramescurrent65-127 Octet Frames.
1.3.6.1.4.1.6296.0.182Notificationpon255OctetFramescurrent128-255 Octet Frames.
1.3.6.1.4.1.6296.0.183Notificationpon511OctetFramescurrent256-511 Octet Frames.
1.3.6.1.4.1.6296.0.184Notificationpon1023OctetFramescurrent512-1023 Octet Frames.
1.3.6.1.4.1.6296.0.185Notificationpon1518OctetFramescurrent1024-1518 Octet Frames.
1.3.6.1.4.1.6296.0.186Notificationpon1519OverOctetFramescurrent1519+ Octet Frames.
1.3.6.1.4.1.6296.0.187NotificationponFramesDroppedcurrentFrames dropped.
1.3.6.1.4.1.6296.0.188NotificationponOctetsDroppedcurrentOctets dropped.
1.3.6.1.4.1.6296.0.189NotificationponOctetsDelayedcurrentOctets delayed.
1.3.6.1.4.1.6296.0.190NotificationponOctetsGrantedcurrentOctets granted.
1.3.6.1.4.1.6296.0.191NotificationponOctetsGrantedButUnusedcurrentOctets granted but unused.
1.3.6.1.4.1.6296.0.192NotificationponMaximumDelaycurrentMaximum Delay (units of 100usec).
1.3.6.1.4.1.6296.0.193NotificationponCRC8ErrorscurrentCRC-8 (preamble) Errors.
1.3.6.1.4.1.6296.0.194NotificationponLineCodeErrorscurrentLine code errors
1.3.6.1.4.1.6296.0.195NotificationponPauseFramescurrentPause Frames
1.3.6.1.4.1.6296.0.196NotificationponErroredFrameSecondscurrentErrored Frame Seconds
1.3.6.1.4.1.6296.0.197NotificationponErroredFramePeriodcurrentErrored Frame Period
1.3.6.1.4.1.6296.0.198NotificationponErroredFrameSecondsSummarycurrentErrored Frame Seconds Summary
1.3.6.1.4.1.6296.0.200NotificationgponOnuRegisteredcurrentRegistered Onu Informations
1.3.6.1.4.1.6296.0.201NotificationgponOnuDeregisteredcurrentDeregistered Onu Informations
1.3.6.1.4.1.6296.0.202NotificationswWatchdogDetectErrorcurrentS/W Watchdog Detect Error
1.3.6.1.4.1.6296.0.203NotificationswWatchdogClearErrorcurrentS/W Watchdog Clear Error
1.3.6.1.4.1.6296.0.204NotificationswWatchdogNormalStatecurrentS/W Watchdog Normal State
1.3.6.1.4.1.6296.0.205NotificationswWatchdogAbnomalStatecurrentS/W Watchdog Abnormal State
1.3.6.1.4.1.6296.0.206NotificationgponOnuUpgradeCompletedcurrentUpgrade Completed Onu Informations
1.3.6.1.4.1.6296.0.207NotificationgponOltCableDowncurrentGPON Cable down event is detected.(This is not used for any product)
1.3.6.1.4.1.6296.0.208NotificationgponOnuAutoToManualcurrentGPON Onu is auto-to-manual
1.3.6.1.4.1.6296.0.209NotificationslotActionEventcurrentThis trap indicates the slot action event
1.3.6.1.4.1.6296.0.210NotificationslotStateChangedcurrentThis trap indicates the slot state is changed
1.3.6.1.4.1.6296.0.211NotificationgponNoAuthONUcurrentNo autheticated ONU
1.3.6.1.4.1.6296.0.212NotificationgponDuplicateONUcurrentDuplicated ONU
1.3.6.1.4.1.6296.0.213NotificationgponDyingGaspcurrentDying Gasp of GPON ONU
1.3.6.1.4.1.6296.0.214NotificationgponRogueOnucurrentFound Rogue ONU.
1.3.6.1.4.1.6296.0.215NotificationgponOnuBatteryEventcurrentBattery Event.
1.3.6.1.4.1.6296.0.216NotificationgponOnuBatteryEventClearedcurrentBattery Event is cleared.
1.3.6.1.4.1.6296.0.217NotificationgponOnuPortOperStatuscurrentThis trap indicates state of ONU Port Operation.
1.3.6.1.4.1.6296.0.218NotificationgponTransceiverChangedcurrentThis trap indicates GPON transceiver changed.
1.3.6.1.4.1.6296.0.219NotificationgponOltLosOncurrentThis trap indicates state of OLT Loss Of Signal (on).
1.3.6.1.4.1.6296.0.220NotificationgponOltLosOffcurrentThis trap indicates state of OLT Loss Of Signal (off).
1.3.6.1.4.1.6296.0.221NotificationgponOltLosiOncurrentThis trap indicates state of OLT Loss Of Signal for ONUi (on).
1.3.6.1.4.1.6296.0.222NotificationgponOltLosiOffcurrentThis trap indicates state of OLT Loss Of Signal for ONUi (off).
1.3.6.1.4.1.6296.0.223NotificationgponDyingGaspOncurrentThis trap indicates Dying Gasp of GPON ONU (on).
1.3.6.1.4.1.6296.0.224NotificationgponDyingGaspOffcurrentThis trap indicates Dying Gasp of GPON ONU (off).
1.3.6.1.4.1.6296.0.225NotificationslotErrorLEDChangedcurrentThis trap indicates slot error LED changed.
1.3.6.1.4.1.6296.0.226NotificationnmsConnectionTypeChangedcurrentThis trap indicates NMS connection type changed.
1.3.6.1.4.1.6296.0.227NotificationgponOntOSUpgradeStatuscurrentThis trap indicates ONT OS upgrade status changes.
1.3.6.1.4.1.6296.0.228NotificationgponOntBLUpgradeStatuscurrentThis trap indicates ONT BL upgrade status changes.
1.3.6.1.4.1.6296.0.229NotificationgponOntRxPowerLosscurrentThis trap indicates ONT port failed to detect Rx Power.
1.3.6.1.4.1.6296.0.230NotificationgponOntRxPowerDetectedcurrentThis trap indicates ONT port detected Rx Power.
1.3.6.1.4.1.6296.0.231NotificationgponOnuTemperatureHighOverThresholdcurrentThis trap indicates the temperature of ONU is over high threshold.
1.3.6.1.4.1.6296.0.232NotificationgponOnuTemperatureHighFallThresholdcurrentThis trap indicates the temperature of ONU falls under high threshold.
1.3.6.1.4.1.6296.0.233NotificationgponOnuTemperatureLowOverThresholdcurrentThis trap indicates the temperature of ONU is over low threshold.
1.3.6.1.4.1.6296.0.234NotificationgponOnuTemperatureLowFallThresholdcurrentThis trap indicates the temperature of ONU falls under low threshold.
1.3.6.1.4.1.6296.0.235NotificationgponOnuCpuOverThresholdcurrentThis trap indicates the CPU-load of ONU is over threshold.
1.3.6.1.4.1.6296.0.236NotificationgponOnuCpuFallThresholdcurrentThis trap indicates the CPU-load of ONU falls under threshold.
1.3.6.1.4.1.6296.0.237NotificationgponOnuMemoryOverThresholdcurrentThis trap indicates the memory-utilization of ONU is over threshold.
1.3.6.1.4.1.6296.0.238NotificationgponOnuMemoryFallThresholdcurrentThis trap indicates the memory-utilization of ONU falls under threshold.
1.3.6.1.4.1.6296.0.239NotificationgponOnuI2cFailcurrentThis trap indicates that detect ONU's i2c fail.
1.3.6.1.4.1.6296.0.240NotificationgponOnuRxOpticPowerLowThreshAlarmOncurrentRX optic low power alarm is detected
1.3.6.1.4.1.6296.0.241NotificationgponOnuRxOpticPowerLowThreshAlarmOffcurrentRX optic low power alarm is cleared
1.3.6.1.4.1.6296.0.242NotificationgponOnuRxOpticPowerHighThreshAlarmOncurrentRX Optic over power alarm is detected
1.3.6.1.4.1.6296.0.243NotificationgponOnuRxOpticPowerHighThreshAlarmOffcurrentRX Optic over power alarm is cleared.
1.3.6.1.4.1.6296.0.244NotificationgponOltLOFIOncurrentOLT LOFI alarm is detected
1.3.6.1.4.1.6296.0.245NotificationgponOltLOFIOffcurrentOLT LOFI alarm is cleared
1.3.6.1.4.1.6296.0.246NotificationgponOltDOWOncurrentOLT DOW alarm is detected
1.3.6.1.4.1.6296.0.247NotificationgponOltDOWOffcurrentOLT DOW alarm is cleared
1.3.6.1.4.1.6296.0.248NotificationgponOltSFOncurrentOLT SF alarm is detected
1.3.6.1.4.1.6296.0.249NotificationgponOltSFOffcurrentOLT SF alarm is cleared
1.3.6.1.4.1.6296.0.250NotificationgponOltSDOncurrentOLT SD alarm is detected
1.3.6.1.4.1.6296.0.251NotificationgponOltSDOffcurrentOLT SD alarm is cleared
1.3.6.1.4.1.6296.0.252NotificationgponOltLCDGIOncurrentOLT LCDGI alarm is detected
1.3.6.1.4.1.6296.0.253NotificationgponOltLCDGIOffcurrentOLT LCDGI alarm is cleared
1.3.6.1.4.1.6296.0.254NotificationgponOltRDOncurrentOLT RD alarm is detected
1.3.6.1.4.1.6296.0.255NotificationgponOltRDOffcurrentOLT RD alarm is cleared
1.3.6.1.4.1.6296.0.256NotificationgponOltSUFOncurrentOLT SUF alarm is detected
1.3.6.1.4.1.6296.0.257NotificationgponOltSUFOffcurrentOLT SUF alarm is cleared
1.3.6.1.4.1.6296.0.258NotificationgponOltLOAOncurrentOLT LOA alarm is detected
1.3.6.1.4.1.6296.0.259NotificationgponOltLOAOffcurrentOLT LOA alarm is cleared
1.3.6.1.4.1.6296.0.260NotificationgponOltLOAMIOncurrentOLT LOAMI alarm is detected
1.3.6.1.4.1.6296.0.261NotificationgponOltLOAMIOffcurrentOLT LOAMI alarm is cleared
1.3.6.1.4.1.6296.0.262NotificationgponOltMEMOncurrentOLT MEM alarm is detected
1.3.6.1.4.1.6296.0.263NotificationgponOltMEMOffcurrentOLT MEM alarm is cleared
1.3.6.1.4.1.6296.0.264NotificationgponOltPEEOncurrentOLT PEE alarm is detected
1.3.6.1.4.1.6296.0.265NotificationgponOltPEEOffcurrentOLT PEE alarm is cleared
1.3.6.1.4.1.6296.0.266NotificationgponOltPSTOncurrentOLT PST alarm is detected
1.3.6.1.4.1.6296.0.267NotificationgponOltPSTOffcurrentOLT PST alarm is cleared
1.3.6.1.4.1.6296.0.268NotificationgponOltERROncurrentOLT alarm error is detected
1.3.6.1.4.1.6296.0.269NotificationgponOltERROffcurrentOLT alarm error is cleared
1.3.6.1.4.1.6296.0.270NotificationgponOltREIOncurrentOLT REI alarm is detected
1.3.6.1.4.1.6296.0.271NotificationgponOltREIOffcurrentOLT REI alarm is cleared.
1.3.6.1.4.1.6296.0.272NotificationgponAntiSpoofingDupPortOncurrentAnti spoofing duplication port alarm is detected
1.3.6.1.4.1.6296.0.273NotificationgponAntiSpoofingDupPortOffcurrentAnti spoofing duplication port alarm is cleared
1.3.6.1.4.1.6296.0.274NotificationgponRedundancySwitchOvercurrentRedundancy switch over
1.3.6.1.4.1.6296.0.275NotificationgponDuplicatedRangingResponsecurrentDuplicated ranging response detection.
1.3.6.1.4.1.6296.0.276NotificationgponOnuPortOpticModuleInstallcurrentONU port optic module install detection.
1.3.6.1.4.1.6296.0.277NotificationgponOnuPortOpticModuleRemovecurrentONU port optic module removal detection.
1.3.6.1.4.1.6296.0.278NotificationgponOnuOMCCProblemDetectedcurrentONU OMCC Problem is detected.
1.3.6.1.4.1.6296.0.279NotificationgponOnuOMCCProblemClearedcurrentONU OMCC Problem is cleared.
1.3.6.1.4.1.6296.0.280NotificationgponOltFixedTcontAlarmOncurrentOLT fixed tcont alarm is detected
1.3.6.1.4.1.6296.0.281NotificationgponOltFixedTcontAlarmOffcurrentOLT fixed tcont alarm is cleared
1.3.6.1.4.1.6296.0.282NotificationgponOltDynamicTcontAlarmOncurrentOLT dynamic tcont alarm is detected.
1.3.6.1.4.1.6296.0.283NotificationgponOltDynamicTcontAlarmOffcurrentOLT dynamic tcont alarm is cleared.
1.3.6.1.4.1.6296.0.284NotificationgponOltPortCountAlarmOncurrentOLT port count alarm is detected.
1.3.6.1.4.1.6296.0.285NotificationgponOltPortCountAlarmOffcurrentOLT port count alarm is cleared.
1.3.6.1.4.1.6296.0.286NotificationgponOltCableDownAlarmOncurrentGPON Cable down event is detected
1.3.6.1.4.1.6296.0.287NotificationgponOltCableDownAlarmOffcurrentGPON Cable down event is cleared
1.3.6.1.4.1.6296.0.288NotificationgponOltDeactiveMonitorAlarmOncurrentGPON deactive monitor alarm is on
1.3.6.1.4.1.6296.0.289NotificationgponOltDeactiveMonitorAlarmOffcurrentGPON deactive monitor alarm is off
1.3.6.1.4.1.6296.0.290NotificationgponOltDFIONcurrentGPON OLT DFI is on
1.3.6.1.4.1.6296.0.291NotificationgponOltDFIOFFcurrentGPON OLT DFI is off
1.3.6.1.4.1.6296.0.294NotificationgponOltTransceiverPortChangedcurrentGPON OLT Transceiver alarm is changed
1.3.6.1.4.1.6296.0.295NotificationgponOltRxOpticPowerHighThresOvercurrentGPON OLT power high threshold is over
1.3.6.1.4.1.6296.0.296NotificationgponOltRxOpticPowerHighThresOverClearedcurrentGPON OLT power high threshold over is cleared
1.3.6.1.4.1.6296.0.297NotificationgponOltRxOpticPowerLowThresUndercurrentGPON OLT power low threshold is under
1.3.6.1.4.1.6296.0.298NotificationgponOltRxOpticPowerLowThresUnderClearedcurrentGPON OLT power low threshold under is cleared
1.3.6.1.4.1.6296.0.301NotificationoamRapsEastPortStatusChangedcurrentThe east port status changed
1.3.6.1.4.1.6296.0.302NotificationoamRapsWestPortStatusChangedcurrentThe west port status changed
1.3.6.1.4.1.6296.0.303NotificationoamURNodePortStatusChangedcurrentOAM uplink redundancy node's port status changed
1.3.6.1.4.1.6296.0.320NotificationloopDetectBlockedcurrentThis trap indicate the Port is blocked by loop-detect.
1.3.6.1.4.1.6296.0.321NotificationloopDetectUnBlockedbyExpireTimercurrentThis trap indicate the Port is unblocked by loop-detect's expire timer.
1.3.6.1.4.1.6296.0.322NotificationloopDetectUnBlockedbyLinkDowncurrentThis trap indicate the Port is unblocked by loop-detect's link down.
1.3.6.1.4.1.6296.0.341NotificationwriteMemoryFailSeveralTimescurrentThis trap indicates the writing memory is failed 3 times
1.3.6.1.4.1.6296.0.342NotificationwriteMemoryFailSeveralTimesClearedcurrentThis trap indicates the writing memory is ok
1.3.6.1.4.1.6296.0.351NotificationemLogDefectCPUHighOvercurrentEM log about CPU load high over.
1.3.6.1.4.1.6296.0.352NotificationemLogDefectCPUHighUndercurrentEM log about CPU load high under.
1.3.6.1.4.1.6296.0.353NotificationemLogTemperHighOvercurrentEM log about temperature high over.
1.3.6.1.4.1.6296.0.354NotificationemLogTemperHighUndercurrentEM log about temperature high under.
1.3.6.1.4.1.6296.0.355NotificationemLogTemperLowUndercurrentEM log about temperature low under (occured).
1.3.6.1.4.1.6296.0.356NotificationemLogTemperLowOvercurrentEM log about temperature low under (cleared).
1.3.6.1.4.1.6296.0.357NotificationemLogMemLowOvercurrentEM log about memory low over (cleared).
1.3.6.1.4.1.6296.0.358NotificationemLogMemLowUndercurrentEM log about memory low over (occured).
1.3.6.1.4.1.6296.0.359NotificationemLogFanFailcurrentEM log about fan fail.
1.3.6.1.4.1.6296.0.360NotificationemLogFanFailClearedcurrentEM log about fan fail cleared.
1.3.6.1.4.1.6296.0.361NotificationemLogPhyCRCFailcurrentEM log about PHY CRC fail.
1.3.6.1.4.1.6296.0.362NotificationemLogPhyCRCFailClearedcurrentEM log about PHY CRC fail cleared.
1.3.6.1.4.1.6296.0.363NotificationemLogPhyDetectFailcurrentEM log about PHY detect fail.
1.3.6.1.4.1.6296.0.364NotificationemLogPhyDetectFailClearedcurrentEM log about PHY detect fail cleared.
1.3.6.1.4.1.6296.0.365NotificationemLogSFUMateInitFailcurrentEM log about SFU mate init fail
1.3.6.1.4.1.6296.0.366NotificationemLogSFUMateInitFailClearedcurrentEM log about SFU mate init fail cleared
1.3.6.1.4.1.6296.0.367NotificationemLogDaemonHealthBadcurrentEM log about daemon health bad
1.3.6.1.4.1.6296.0.368NotificationemLogDaemonHealthBadClearedcurrentEM log about daemon health bad cleared
1.3.6.1.4.1.6296.0.369NotificationemLogGPIURavenLinkDowncurrentEM log about GPIU raven link down
1.3.6.1.4.1.6296.0.370NotificationemLogGPIURavenLinkDownClearedcurrentEM log about GPIU raven link down cleared
1.3.6.1.4.1.6296.0.371NotificationbootSequenceConfigFilecurrentBoot Sequence Config File failed
1.3.6.1.4.1.6296.0.372NotificationtopologyChangedcurrentTopolgy changed
1.3.6.1.4.1.6296.0.373NotificationconfigLoadFailcurrentConfig load failed
1.3.6.1.4.1.6296.0.375NotificationemlogFanRPMLowcurrentFAN RPM Low detected in EMLOG
1.3.6.1.4.1.6296.0.376NotificationemlogFanRPMLowClearedcurrentFAN RPM Low cleared in EMLOG
1.3.6.1.4.1.6296.0.377NotificationemlogNAKErrorcurrentNAK Error detected in EMLOG
1.3.6.1.4.1.6296.0.378NotificationemlogNAKErrorClearedcurrentNAK Error cleared in EMLOG
1.3.6.1.4.1.6296.0.381NotificationgponOnuAniVoltageLowThreshAlarmOncurrentVoltage low threshold alarm on
1.3.6.1.4.1.6296.0.382NotificationgponOnuAniVoltageLowThreshAlarmOffcurrentVoltage low threshold alarm off
1.3.6.1.4.1.6296.0.383NotificationgponOnuAniVoltageHighThreshAlarmOncurrentVoltage high threshold alarm on
1.3.6.1.4.1.6296.0.384NotificationgponOnuAniVoltageHighThreshAlarmOffcurrentVoltage high threshold alarm off
1.3.6.1.4.1.6296.0.385NotificationgponOnuAniTemperatureLowThreshAlarmOncurrentTemperature low threshold alarm on
1.3.6.1.4.1.6296.0.386NotificationgponOnuAniTemperatureLowThreshAlarmOffcurrentTemperature high threshold alarm off
1.3.6.1.4.1.6296.0.387NotificationgponOnuAniTemperatureHighThreshAlarmOncurrentTemperature high threshold alarm on
1.3.6.1.4.1.6296.0.388NotificationgponOnuAniTemperatureHighThreshAlarmOffcurrentTemperature high threshold alarm off
1.3.6.1.4.1.6296.0.389NotificationgponOnuAniTxBiasLowThreshAlarmOncurrentTX-bias low threshold alarm on
1.3.6.1.4.1.6296.0.390NotificationgponOnuAniTxBiasLowThreshAlarmOffcurrentTX-bias low threshold alarm off
1.3.6.1.4.1.6296.0.391NotificationgponOnuAniTxBiasHighThreshAlarmOncurrentTX-bias high threshold alarm on
1.3.6.1.4.1.6296.0.392NotificationgponOnuAniTxBiasHighThreshAlarmOffcurrentTX-bias high threshold alarm off
1.3.6.1.4.1.6296.0.393NotificationgponOnuAniTxpowerLowThreshAlarmOncurrentTX-power low threshold alarm on
1.3.6.1.4.1.6296.0.394NotificationgponOnuAniTxpowerLowThreshAlarmOffcurrentTX-power low threshold alarm off
1.3.6.1.4.1.6296.0.395NotificationgponOnuAniTxpowerHighThreshAlarmOncurrentTX-power high threshold alarm on
1.3.6.1.4.1.6296.0.396NotificationgponOnuAniTxpowerHighThreshAlarmOffcurrentTX-power high threshold alarm off
1.3.6.1.4.1.6296.0.397NotificationslotHealthStatusTimeoutcurrentThis trap indicates the slot health status time-out is occurred
1.3.6.1.4.1.6296.0.398NotificationslotHealthStatusTimeoutClearedcurrentThis trap indicates the slot health status time-out trap is cleared
1.3.6.1.4.1.6296.0.401NotificationsfpDMIDiagTemperOverHighAlarmcurrentThis trap indicates the temperature of sfp is over the high threshold.(Alarm)
1.3.6.1.4.1.6296.0.402NotificationsfpDMIDiagTemperUnderHighAlarmcurrentThis trap indicates the temperature of sfp is under the high threshold.(Alarm)
1.3.6.1.4.1.6296.0.403NotificationsfpDMIDiagTemperUnderLowAlarmcurrentThis trap indicates the temperature of sfp is under the low threshold.(Alarm)
1.3.6.1.4.1.6296.0.404NotificationsfpDMIDiagTemperOverLowAlarmcurrentThis trap indicates the temperature of sfp is over the low threshold.(Alarm)
1.3.6.1.4.1.6296.0.405NotificationsfpDMIDiagTemperOverHighWarncurrentThis trap indicates the temperature of sfp is over the high threshold.(Warn)
1.3.6.1.4.1.6296.0.406NotificationsfpDMIDiagTemperUnderHighWarncurrentThis trap indicates the temperature of sfp is under the high threshold.(Warn)
1.3.6.1.4.1.6296.0.407NotificationsfpDMIDiagTemperUnderLowWarncurrentThis trap indicates the temperature of sfp is under the low threshold.(Warn)
1.3.6.1.4.1.6296.0.408NotificationsfpDMIDiagTemperOverLowWarncurrentThis trap indicates the temperature of sfp is over the low threshold.(Warn)
1.3.6.1.4.1.6296.0.409NotificationsfpDMIDiagVoltageOverHighAlarmcurrentThis trap indicates the voltage of sfp is over the high threshold.(Alarm)
1.3.6.1.4.1.6296.0.410NotificationsfpDMIDiagVoltageUnderHighAlarmcurrentThis trap indicates the voltage of sfp is under the high threshold.(Alarm)
1.3.6.1.4.1.6296.0.411NotificationsfpDMIDiagVoltageUnderLowAlarmcurrentThis trap indicates the voltage of sfp is under the low threshold.(Alarm)
1.3.6.1.4.1.6296.0.412NotificationsfpDMIDiagVoltageOverLowAlarmcurrentThis trap indicates the voltage of sfp is over the low threshold.(Alarm)
1.3.6.1.4.1.6296.0.413NotificationsfpDMIDiagVoltageOverHighWarncurrentThis trap indicates the voltage of sfp is over the high threshold.(Warn)
1.3.6.1.4.1.6296.0.414NotificationsfpDMIDiagVoltageUnderHighWarncurrentThis trap indicates the voltage of sfp is under the high threshold.(Warn)
1.3.6.1.4.1.6296.0.415NotificationsfpDMIDiagVoltageUnderLowWarncurrentThis trap indicates the voltage of sfp is under the low threshold.(Warn)
1.3.6.1.4.1.6296.0.416NotificationsfpDMIDiagVoltageOverLowWarncurrentThis trap indicates the voltage of sfp is over the low threshold.(Warn)
1.3.6.1.4.1.6296.0.417NotificationsfpDMIDiagTxBiasOverHighAlarmcurrentThis trap indicates the TxBias of sfp is over the high threshold.(Alarm)
1.3.6.1.4.1.6296.0.418NotificationsfpDMIDiagTxBiasUnderHighAlarmcurrentThis trap indicates the TxBias of sfp is under the high threshold.(Alarm)
1.3.6.1.4.1.6296.0.419NotificationsfpDMIDiagTxBiasUnderLowAlarmcurrentThis trap indicates the TxBias of sfp is under the low threshold.(Alarm)
1.3.6.1.4.1.6296.0.420NotificationsfpDMIDiagTxBiasOverLowAlarmcurrentThis trap indicates the TxBias of sfp is over the low threshold.(Alarm)
1.3.6.1.4.1.6296.0.421NotificationsfpDMIDiagTxBiasOverHighWarncurrentThis trap indicates the TxBias of sfp is over the high threshold.(Warn)
1.3.6.1.4.1.6296.0.422NotificationsfpDMIDiagTxBiasUnderHighWarncurrentThis trap indicates the TxBias of sfp is under the high threshold.(Warn)
1.3.6.1.4.1.6296.0.423NotificationsfpDMIDiagTxBiasUnderLowWarncurrentThis trap indicates the TxBias of sfp is under the low threshold.(Warn)
1.3.6.1.4.1.6296.0.424NotificationsfpDMIDiagTxBiasOverLowWarncurrentThis trap indicates the TxBias of sfp is over the low threshold.(Warn)
1.3.6.1.4.1.6296.0.425NotificationsfpDMIDiagTxPowerOverHighAlarmcurrentThis trap indicates the TxPower of sfp is over the high threshold.(Alarm)
1.3.6.1.4.1.6296.0.426NotificationsfpDMIDiagTxPowerUnderHighAlarmcurrentThis trap indicates the TxPower of sfp is under the high threshold.(Alarm)
1.3.6.1.4.1.6296.0.427NotificationsfpDMIDiagTxPowerUnderLowAlarmcurrentThis trap indicates the TxPower of sfp is under the low threshold.(Alarm)
1.3.6.1.4.1.6296.0.428NotificationsfpDMIDiagTxPowerOverLowAlarmcurrentThis trap indicates the TxPower of sfp is over the low threshold.(Alarm)
1.3.6.1.4.1.6296.0.429NotificationsfpDMIDiagTxPowerOverHighWarncurrentThis trap indicates the TxPower of sfp is over the high threshold.(Warn)
1.3.6.1.4.1.6296.0.430NotificationsfpDMIDiagTxPowerUnderHighWarncurrentThis trap indicates the TxPower of sfp is under the high threshold.(Warn)
1.3.6.1.4.1.6296.0.431NotificationsfpDMIDiagTxPowerUnderLowWarncurrentThis trap indicates the TxPower of sfp is under the low threshold.(Warn)
1.3.6.1.4.1.6296.0.432NotificationsfpDMIDiagTxPowerOverLowWarncurrentThis trap indicates the TxPower of sfp is over the low threshold.(Warn)
1.3.6.1.4.1.6296.0.433NotificationsfpDMIDiagRxPowerOverHighAlarmcurrentThis trap indicates the RxPower of sfp is over the high threshold.(Alarm)
1.3.6.1.4.1.6296.0.434NotificationsfpDMIDiagRxPowerUnderHighAlarmcurrentThis trap indicates the RxPower of sfp is under the high threshold.(Alarm)
1.3.6.1.4.1.6296.0.435NotificationsfpDMIDiagRxPowerUnderLowAlarmcurrentThis trap indicates the RxPower of sfp is under the low threshold.(Alarm)
1.3.6.1.4.1.6296.0.436NotificationsfpDMIDiagRxPowerOverLowAlarmcurrentThis trap indicates the RxPower of sfp is over the low threshold.(Alarm)
1.3.6.1.4.1.6296.0.437NotificationsfpDMIDiagRxPowerOverHighWarncurrentThis trap indicates the RxPower of sfp is over the high threshold.(Warn)
1.3.6.1.4.1.6296.0.438NotificationsfpDMIDiagRxPowerUnderHighWarncurrentThis trap indicates the RxPower of sfp is under the high threshold.(Warn)
1.3.6.1.4.1.6296.0.439NotificationsfpDMIDiagRxPowerUnderLowWarncurrentThis trap indicates the RxPower of sfp is under the low threshold.(Warn)
1.3.6.1.4.1.6296.0.440NotificationsfpDMIDiagRxPowerOverLowWarncurrentThis trap indicates the RxPower of sfp is over the low threshold.(Warn)
1.3.6.1.4.1.6296.0.441NotificationgponOnuOnuServiceOpModeAlarmcurrentGPON ONU service operational mode alarm.
1.3.6.1.4.1.6296.0.442NotificationgponOnuOnuServiceOpModeAlarmOffcurrentGPON ONU service operational mode cleared alarm.
1.3.6.1.4.1.6296.0.443NotificationsystemTemperPowerCutOffcurrentThis trap indicates the system temperature power cut off
1.3.6.1.4.1.6296.0.444NotificationsystemTemperPowerCutoffClearedcurrentThis trap indicates the system temperature power cut off trap is cleared
1.3.6.1.4.1.6296.0.445NotificationslotTemperPowerCutOffcurrentThis trap indicates the slot temperature power cut off
1.3.6.1.4.1.6296.0.446NotificationslotTemperPowerCutOffClearedcurrentThis trap indicates the slot temperature power cut off is cleared
1.3.6.1.4.1.6296.0.461NotificationgponOnuAuthErrorReasonUpdatedcurrentThis trap indicates GPON ONU authentication error reason is updated
1.3.6.1.4.1.6296.0.501NotificationponRegErrcurrentThis trap indicates the pon registration is not ok
1.3.6.1.4.1.6296.0.502NotificationponBadEncryptionKeycurrentThis trap indicates the pon encryption key is bad
1.3.6.1.4.1.6296.0.503NotificationponLloidMismatchcurrentThis trap indicates the pon LLOID is mismatched
1.3.6.1.4.1.6296.0.504NotificationponTooManyOnucurrentThis trap indicates the pon has too many of ONU
1.3.6.1.4.1.6296.0.505NotificationponDyingGaspcurrentThis trap indicates the pon dying GASP
1.3.6.1.4.1.6296.0.506NotificationponRegistercurrentThis trap indicates the pon is registered
1.3.6.1.4.1.6296.0.507NotificationponDeregistercurrentThis trap indicates the pon is deregistered
1.3.6.1.4.1.6296.0.508NotificationponLastOnuDeregistercurrentThis trap indicates the last ONU is deregistered
1.3.6.1.4.1.6296.0.509NotificationponCableDowncurrentThis trap indicates the pon cable is down
1.3.6.1.4.1.6296.0.510NotificationponCableDownRecovercurrentThis trap indicates the pon cable down is recovered
1.3.6.1.4.1.6296.0.511NotificationponFirstRegistrationcurrentThis trap indicates the first pon registration
1.3.6.1.4.1.6296.0.512NotificationponOntLinkUpcurrentThis trap indicates the ont link up
1.3.6.1.4.1.6296.0.513NotificationponOltOnuDowncurrentThis trap indicates the Onu down
1.3.6.1.4.1.6296.0.514NotificationponHealthCheckErrcurrentThis trap indicates the pon health check error
1.3.6.1.4.1.6296.0.515NotificationponRegisterModeChangecurrentThis trap indicates the pon register mode is changed
1.3.6.1.4.1.6296.0.516NotificationponOpticSignalErrcurrentThis trap indicates the pon optic signal error
1.3.6.1.4.1.6296.0.517NotificationponOpticSignalErrRecovercurrentThis trap indicates the pon optic signal error is recovered
1.3.6.1.4.1.6296.0.518NotificationponOverVolSigErrcurrentThis trap indicates the pon over volatage signal error
1.3.6.1.4.1.6296.0.519NotificationponOverVolSigErrRecovercurrentThis trap indicates the pon over volatage signal error is recovered
1.3.6.1.4.1.6296.0.520NotificationponOnuRssiInfoErrcurrentThis trap indicates the Onu RSSI information error
1.3.6.1.4.1.6296.0.521NotificationponOnuRssiInfoErrClearedcurrentThis trap indicates the Onu RSSI information error is cleard
1.3.6.1.4.1.6296.0.522NotificationponOnuCrcUpAlarmErrcurrentThis trap indicates the ONU CRC up alarm error
1.3.6.1.4.1.6296.0.523NotificationponOnuCrcUpAlarmErrClearedcurrentThis trap indicates the ONU CRC up alarm error is cleared
1.3.6.1.4.1.6296.0.524NotificationponOnuCrcDownAlarmErrcurrentThis trap indicates the ONU CRC down alarm error
1.3.6.1.4.1.6296.0.525NotificationponOnuCrcDownAlarmErrClearedcurrentThis trap indicates the ONU CRC down alarm error is cleared
1.3.6.1.4.1.6296.0.526NotificationponOnuTooFrequentlyRegErrcurrentThis trap indicates the ONU is registered too frequently.
1.3.6.1.4.1.6296.0.527NotificationponOnuTooFrequentlyRegErrClearedcurrentThis trap indicates the ONU registration frequently error is cleared.
1.3.6.1.4.1.6296.0.528NotificationponOnuOpticPowerAlarmErrcurrentThis trap indicates the pon ONU optic power alarm error
1.3.6.1.4.1.6296.0.529NotificationponOnuOpticPowerAlarmErrClearedcurrentThis trap indicates the pon ONU optic power alarm error is cleared
1.3.6.1.4.1.6296.0.530NotificationponOnuDcVoltageAlarmErrcurrentThis trap indicates the pon ONU DC voltage alarm error
1.3.6.1.4.1.6296.0.531NotificationponOnuDcVoltageAlarmErrClearedcurrentThis trap indicates the pon ONU DC voltage alarm error is cleared
1.3.6.1.4.1.6296.0.532NotificationponOnuLoopingAlarmErrcurrentThis trap indicates the pon ONU looping alarm error
1.3.6.1.4.1.6296.0.533NotificationponOnuLoopingAlarmErrClearedcurrentThis trap indicates the pon ONU looping alarm error is cleared
1.3.6.1.4.1.6296.0.534NotificationponDetectRogueOnucurrentThis trap indicates the Rogue ONU detection.
1.3.6.1.4.1.6296.0.535NotificationponDetectRogueOnuClearedcurrentThis trap indicates the Rogue ONU detection is cleared.
1.3.6.1.4.1.6296.0.536NotificationponDetectRogueOnuPowerOffcurrentThis trap indicates the Rogue ONU power off is detected.
1.3.6.1.4.1.6296.0.537NotificationponDetectRogueOnuDeregisterSuccesscurrentThis trap indicates the Rogue ONU deregister success is detected
1.3.6.1.4.1.6296.0.538NotificationponDectectRogueOnuFoundFailedcurrentThis trap indicates the Rogue ONU found fail is detected.
1.3.6.1.4.1.6296.0.539NotificationponDectectRogueOnuTurncurrentThis trap indicates the Rogue ONU turn is detected.
1.3.6.1.4.1.6296.0.540NotificationponOltStandbyRxpowerOverHighcurrentThis trap indicates the Olt standby RX power is over high threshold
1.3.6.1.4.1.6296.0.541NotificationponOltStandbyRxpowerUnderLowcurrentThis trap indicates the Olt standby RX power is under low threshold
1.3.6.1.4.1.6296.0.542NotificationponOltRedundancyPortDowncurrentThis trap indicates the Olt redundancy port is down
1.3.6.1.4.1.6296.0.543NotificationponOltRedundancyRxpowercurrentThis trap indicates the Olt redundancy RXpower
1.3.6.1.4.1.6296.0.544NotificationponOnuBcastStormLlidUpErrcurrentThis trap indicates the broadcast storm llid up error
1.3.6.1.4.1.6296.0.545NotificationponOnuBcastStormLlidUpErrClearedcurrentThis trap indicates the broadcast storm llid up error is cleared
1.3.6.1.4.1.6296.0.546NotificationponOnuBcastStormLlidDownErrcurrentThis trap indicates the broadcast storm llid down error
1.3.6.1.4.1.6296.0.547NotificationponOnuBcastStormLlidDownErrClearedcurrentThis trap indicates the broadcast storm llid down error is cleared
1.3.6.1.4.1.6296.0.548NotificationponOnuBcastStormUniUpErrcurrentThis trap indicates the broadcast storm UNI up error
1.3.6.1.4.1.6296.0.549NotificationponOnuBcastStormUniUpErrClearedcurrentThis trap indicates the broadcast storm Uni up error is cleared
1.3.6.1.4.1.6296.0.550NotificationponOnuResetcurrentThis trap indicates Pon ONU reset
1.3.6.1.4.1.6296.0.551NotificationponOnuLifLcErrAlarmErrcurrentThis trap indicates Pon ONU LIF Error
1.3.6.1.4.1.6296.0.552NotificationponOnuLifLcErrAlarmErrClearedcurrentThis trap indicates Pon ONU LIF Error is cleared
1.3.6.1.4.1.6296.0.561NotificationponOltResetPonMaccurrentThis trap indicates Pon OLT MAC reset
1.3.6.1.4.1.6296.0.581NotificationponOltRedSwitchovercurrentThis trap indicates the OLT redundancy switchover
1.3.6.1.4.1.6296.0.582NotificationponOltRedGroupCreatedcurrentThis trap indicates the OLT redundancy group is created
1.3.6.1.4.1.6296.0.583NotificationponOltRedGroupDeletedcurrentThis trap indicates the OLT redundancy group is deleted
1.3.6.1.4.1.6296.0.584NotificationponOltRedTriggerChangedcurrentThis trap indicates the OLT redundancy trigger is changed
1.3.6.1.4.1.6296.0.585NotificationponOltRedDbResyncChangedcurrentThis trap indicates the OLT redundancy DB resync is changed
1.3.6.1.4.1.6296.0.586NotificationponOltRedDbSyncCheckedcurrentThis trap indicates the OLT redundancy DB sync is checked
1.3.6.1.4.1.6296.0.601NotificationponOnuRssiWarncurrentThis trap indicates the ONU RSSI warning
1.3.6.1.4.1.6296.0.602NotificationponOnuRssiWarnClearedcurrentThis trap indicates the ONU RSSI warning is cleared
1.3.6.1.4.1.6296.0.603NotificationponOnuRssiAlarmcurrentThis trap indicates the ONU RSSI alarm
1.3.6.1.4.1.6296.0.604NotificationponOnuRssiAlarmClearedcurrentThis trap indicates the ONU RSSI alarm is cleared
1.3.6.1.4.1.6296.0.605NotificationponOnuRxpowerWarncurrentThis trap indicates the ONU RX-power warning
1.3.6.1.4.1.6296.0.606NotificationponOnuRxpowerWarnClearedcurrentThis trap indicates the ONU RX-power warning is cleared
1.3.6.1.4.1.6296.0.607NotificationponOnuRxpowerAlarmcurrentThis trap indicates the ONU RX-power alarm
1.3.6.1.4.1.6296.0.608NotificationponOnuRxpowerAlarmClearedcurrentThis trap indicates the ONU RX-power alarm is cleared
1.3.6.1.4.1.6296.0.609NotificationponMacTableOverFlowcurrentThis trap indicates the Mac table is over Max entry.
1.3.6.1.4.1.6296.0.610NotificationponMacTableOverFlowClearedcurrentThis trap indicates the Mac over max entry is cleared.
1.3.6.1.4.1.6296.0.611NotificationfiberLengthChangedWarningAlarmcurrentThis trap indicates the fiber length is changed
1.3.6.1.4.1.6296.0.612NotificationfiberLengthChangedWarningAlarmClearedcurrentThis trap indicates the fiber length trap is cleared
1.3.6.1.4.1.6296.0.613NotificationponOnuFrameReplicationAlarmcurrentThis trap indicates the frame is replicated.
1.3.6.1.4.1.6296.0.614NotificationponOnuFrameReplicationAlarmClearedcurrentThis trap indicates the frame is replicated.
1.3.6.1.4.1.6296.0.615NotificationponOnuRxpowerWarnOverHighcurrentThis trap indicates the ONU RX-power high over warning
1.3.6.1.4.1.6296.0.616NotificationponOnuRxpowerWarnOverHighClearedcurrentThis trap indicates the ONU RX-power high over warning is cleared
1.3.6.1.4.1.6296.0.617NotificationponOnuRxpowerWarnUnderLowcurrentThis trap indicates the ONU RX-power low under warning
1.3.6.1.4.1.6296.0.618NotificationponOnuRxpowerWarnUnderLowClearedcurrentThis trap indicates the ONU RX-power low under warning is cleared
1.3.6.1.4.1.6296.0.619NotificationponOnuRxpowerAlarmOverHighcurrentThis trap indicates the ONU RX-power high over alarm
1.3.6.1.4.1.6296.0.620NotificationponOnuRxpowerAlarmOverHighClearedcurrentThis trap indicates the ONU RX-power high over alarm is cleared
1.3.6.1.4.1.6296.0.621NotificationponOnuRxpowerAlarmUnderLowcurrentThis trap indicates the ONU RX-power low under alarm
1.3.6.1.4.1.6296.0.622NotificationponOnuRxpowerAlarmUnderLowClearedcurrentThis trap indicates the ONU RX-power low under alarm is cleared
1.3.6.1.4.1.6296.0.623NotificationponOnuUniLinkDowncurrentThis trap indicates the Onu Uni link is down.
1.3.6.1.4.1.6296.0.624NotificationponOnuUniLinkUpcurrentThis trap indicates the Onu Uni link is up.