MIB Viewer

DLINKPRIME-POE-MIB

23 objects
A MIB module for extending POWER-ETHERNET-MIB specified in RFC 3621.
Imported Objects
DLINK-ID-REC-MIBdlinkPrimeCommon
POWER-ETHERNET-MIBpethPsePortIndex
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIInteger32 MODULE-IDENTITY OBJECT-TYPE
SNMPv2-TCDisplayString TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.171.15.11IdentitydlinkPrimePoeExtMIBA MIB module for extending POWER-ETHERNET-MIB specified in RFC 3621.
1.3.6.1.4.1.171.15.11.0NodedpPoeMIBNotifications
1.3.6.1.4.1.171.15.11.1NodedpPoeMIBObjects
1.3.6.1.4.1.171.15.11.1.1NodedpPoeIfObjects
1.3.6.1.4.1.171.15.11.1.1.1TabledpPoeIfCfgTablenot-accessiblecurrentThis table consists of a list of PoE configuration information for ports.
1.3.6.1.4.1.171.15.11.1.1.1.1RowdpPoeIfCfgEntrynot-accessiblecurrentAn entry contains PoE configuration on a port.
1.3.6.1.4.1.171.15.11.1.1.1.1.1ColumndpPoeIfStateread-writecurrentThis object indicates the PoE state of the entry. auto(1) - the port will automatically detect the PD and provision power to the PD. The max wattage value whic…
1.3.6.1.4.1.171.15.11.1.1.1.1.2ColumndpPoeIfMaxPowerread-writecurrentThis object indicates the max wattage value which can be provisioned to the port. Note: This object is valid only while the dpPoeIfState object is configured a…
1.3.6.1.4.1.171.15.11.1.1.1.1.3ColumndpPoeIfTimeRangeread-writecurrentThis object indicates the name of time-range profile to delineate the activation period. A zero length string indicates the time-range is not specified.
1.3.6.1.4.1.171.15.11.1.1.2NodedpPoeIfInfoObjects
1.3.6.1.4.1.171.15.11.1.1.2.1TabledpPoeIfStatusTablenot-accessiblecurrentThis table consists of a list of PoE status for ports.
1.3.6.1.4.1.171.15.11.1.1.2.1.1RowdpPoeIfStatusEntrynot-accessiblecurrentAn entry consists of PoE status for a port.
1.3.6.1.4.1.171.15.11.1.1.2.1.1.1ColumndpPoeIfDetectStatusread-onlycurrentThis object indicates the operational status of the port PD detection. disabled(1) - PSE function is disabled. searching(2) - Remote PD is not connected. reque…
1.3.6.1.4.1.171.15.11.1.1.2.1.1.2ColumndpPoeIfFaultyTyperead-onlycurrentThis object indicates the specific faulty type. It is meaningful only when dpPoeIfDetectStatus object is 'faulty'. notApplicable(0) - indicates this object is …
1.3.6.1.4.1.171.15.11.1.1.2.2TabledpPoeIfMeasurementTablenot-accessiblecurrentThis table consists of a list of POE measurement information for ports.
1.3.6.1.4.1.171.15.11.1.1.2.2.1RowdpPoeIfMeasurementEntrynot-accessiblecurrentAn entry consists of PoE measurement information of a port.
1.3.6.1.4.1.171.15.11.1.1.2.2.1.1ColumndpPoeIfPowerread-onlycurrentThis object indicates consumption power of port in milliwatts.
1.3.6.1.4.1.171.15.11.2NodedpPoeMIBConformance
1.3.6.1.4.1.171.15.11.2.1NodedpPoeMIBCompliances
1.3.6.1.4.1.171.15.11.2.1.1CompliancedpPoeMIBCompliancecurrentThe compliance statement for entities which implement the DLINKPRIME-POE-MIB.
1.3.6.1.4.1.171.15.11.2.2NodedpPoeMIBGroups
1.3.6.1.4.1.171.15.11.2.2.1GroupdpPoeIfCfgGroupcurrentA collection of objects configure or display the ports information.
1.3.6.1.4.1.171.15.11.2.2.2GroupdpPoeIfInfoGroupcurrentA collection of objects display the ports information.