ENTERASYS-POWER-ETHERNET-EXT-MIB
52 objects
This MIB module defines a portion of the SNMP MIB under the Enterasys Networks enterprise OID pertaining to the allocation of power in a Pse chassis.
Imported Objects
| ENTERASYS-MIB-NAMES | etsysModules |
| ENTITY-MIB | entPhysicalIndex |
| P-BRIDGE-MIB | EnabledStatus |
| POWER-ETHERNET-MIB | pethMainPseEntry pethPsePortEntry |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | BITS Gauge32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.5624.1.2.50 | IdentityetsysPowerEthernetMibExtMIB | This MIB module defines a portion of the SNMP MIB under the Enterasys Networks enterprise OID pertaining to the allocation of power in a Pse chassis. | ||
| 1.3.6.1.4.1.5624.1.2.50.1 | NodeetsysPowerEthernetObjects | |||
| 1.3.6.1.4.1.5624.1.2.50.1.0 | NodeetsysPsePowerNotification | |||
| 1.3.6.1.4.1.5624.1.2.50.1.0.1 | NotificationetsysPseChassisPowerRedundant | current | Pse chassis power is in redundant state. At least 500 msec must elapse between notifications being emitted by the same object instance. | |
| 1.3.6.1.4.1.5624.1.2.50.1.0.2 | NotificationetsysPseChassisPowerNonRedundant | current | Pse chassis power is in non-redundant state. At least 500 msec must elapse between notifications being emitted by the same object instance. | |
| 1.3.6.1.4.1.5624.1.2.50.1.0.3 | NotificationetsysPsePowerSupplyModuleStatusChange | current | A Pse Power Supply module has changed state. At least 500 msec must elapse between notifications being emitted by the same object instance. | |
| 1.3.6.1.4.1.5624.1.2.50.1.1 | NodeetsysPseChassisPowerAllocation | |||
| 1.3.6.1.4.1.5624.1.2.50.1.1.1 | ScalaretsysPseChassisPowerAllocationMode | read-write | current | In auto mode, a Pse Power Management Algorithm handles the allocation of power to all the modules. In manual mode, power is manually allocated to the modules v… |
| 1.3.6.1.4.1.5624.1.2.50.1.1.2 | ScalaretsysPseChassisPowerSnmpNotification | read-write | current | The current state of the SNMP Notification functionality for Pse. enabled (1) - The Pse will generate SNMP Notifications for potentially adverse Pse power cond… |
| 1.3.6.1.4.1.5624.1.2.50.1.1.3 | ScalaretsysPseChassisPowerAvailableMaximum | read-write | current | The maximum percentage of power from the Pse Power Supply that this chassis can use. The default value should be 100 percent, meaning the chassis can use all t… |
| 1.3.6.1.4.1.5624.1.2.50.1.2 | NodeetsysPseSlotPowerAllocation | |||
| 1.3.6.1.4.1.5624.1.2.50.1.2.1 | TableetsysPseSlotPowerAllocationTable | not-accessible | current | Power allocation management information for all slots. |
| 1.3.6.1.4.1.5624.1.2.50.1.2.1.1 | RowetsysPseSlotPowerAllocationEntry | not-accessible | current | Power allocation management information for an entPhysicalEntry that has an entPhysicalClass of container(5) and represents a slot in the chassis that could be… |
| 1.3.6.1.4.1.5624.1.2.50.1.2.1.1.1 | ColumnetsysPseSlotPowerMaximum | read-only | current | The maximum power that can be consumed by the module in this slot, based on the module's characteristics. For slots without Pse modules this object MUST return… |
| 1.3.6.1.4.1.5624.1.2.50.1.2.1.1.2 | ColumnetsysPseSlotPowerAssigned | read-write | current | The power that will be allocated to this slot in manual mode. In auto mode, this object has no effect. Maintaining the value of this object across agent reboot… |
| 1.3.6.1.4.1.5624.1.2.50.1.3 | NodeetsysPseChassisPowerStatus | |||
| 1.3.6.1.4.1.5624.1.2.50.1.3.1 | ScalaretsysPseChassisPowerDetected | read-only | current | The total power detected by the chassis from Pse Power Supply. |
| 1.3.6.1.4.1.5624.1.2.50.1.3.2 | ScalaretsysPseChassisPowerAvailable | read-only | current | The total power available for this chassis. This is ( etsysPseChassisPowerDetected * ( etsysPseChassisPowerAvailableMaximum / 100 ) ). |
| 1.3.6.1.4.1.5624.1.2.50.1.3.3 | ScalaretsysPseChassisPowerConsumable | read-only | current | The total power that could be consumed by all of the Pse modules in the chassis. This is the summation of the values of all of the etsysPseSlotPowerMaximum obj… |
| 1.3.6.1.4.1.5624.1.2.50.1.3.4 | ScalaretsysPseChassisPowerAssigned | read-only | current | The total power assigned to the slots in the chassis. This is the summation of the values of all of the etsysPseSlotPowerAssigned objects. |
| 1.3.6.1.4.1.5624.1.2.50.1.3.5 | ScalaretsysPseChassisPowerRedundancy | read-only | current | Denotes whether or not the Pse power system has redundant capacity. |
| 1.3.6.1.4.1.5624.1.2.50.1.3.6 | TableetsysPsePowerSupplyStatusTable | not-accessible | current | Status information for all of the Pse power supply modules. |
| 1.3.6.1.4.1.5624.1.2.50.1.3.6.1 | RowetsysPsePowerSupplyStatusEntry | not-accessible | current | Status information for an individual Pse power supply module. |
| 1.3.6.1.4.1.5624.1.2.50.1.3.6.1.1 | ColumnetsysPsePowerSupplyModuleNumber | not-accessible | current | A unique number that identifies the Pse power supply and is relative to the module's physical location. |
| 1.3.6.1.4.1.5624.1.2.50.1.3.6.1.2 | ColumnetsysPsePowerSupplyModuleStatus | read-only | current | Denotes the power supply's status. |
| 1.3.6.1.4.1.5624.1.2.50.1.4 | NodeetsysPseSlotPowerManagement | |||
| 1.3.6.1.4.1.5624.1.2.50.1.4.1 | TableetsysPseModulePowerManagementTable | not-accessible | current | This table augments the pethMainPseTable of the PowerEthernetMIB (rfc3621). It provides objects that are used to budget power. |
| 1.3.6.1.4.1.5624.1.2.50.1.4.1.1 | RowetsysPseModulePowerManagementEntry | not-accessible | current | A set of objects that display, control, and calculate the power consumption of a PSE. |
| 1.3.6.1.4.1.5624.1.2.50.1.4.1.1.1 | ColumnetsysPseModulePowerMode | read-write | current | This object controls the power management of the PSE. It also controls how etsysPseModulePowerClassBudget, etsysPseModulePowerUsage and etsysPsePortPowerLimit … |
| 1.3.6.1.4.1.5624.1.2.50.1.4.1.1.2 | ColumnetsysPseModulePowerClassBudget | read-only | current | In class mode, this is sum of all ports power according to their class upper bound, except classes 0 & 4 for which the actual power consumption is accounted. I… |
| 1.3.6.1.4.1.5624.1.2.50.1.4.1.1.3 | ColumnetsysPseModulePowerUsage | read-only | current | In class mode, this is ratio of etsysPseModulePowerClassBudget over pethMainPsePower, expressed in percents. In realtime mode, this is ratio of pethMainPseCons… |
| 1.3.6.1.4.1.5624.1.2.50.1.5 | NodeetsysPsePortPowerManagement | |||
| 1.3.6.1.4.1.5624.1.2.50.1.5.1 | TableetsysPsePortPowerManagementTable | not-accessible | current | This table augments the pethPsePortTable of the PowerEthernetMIB (rfc3621). It provides objects that are used to budget power. |
| 1.3.6.1.4.1.5624.1.2.50.1.5.1.1 | RowetsysPsePortPowerManagementEntry | not-accessible | current | A set of objects that display and control the power consumption of a PSE, at the port level. |
| 1.3.6.1.4.1.5624.1.2.50.1.5.1.1.1 | ColumnetsysPsePortPowerLimit | read-write | current | This object sets the maximum power allowed on this port. If the port exceeds its power limit, it will be shut down. This object has effect only when its module… |
| 1.3.6.1.4.1.5624.1.2.50.1.5.1.1.2 | ColumnetsysPsePortPowerUsage | read-only | current | Actual power consumption measured in real-time. |
| 1.3.6.1.4.1.5624.1.2.50.1.5.1.1.3 | ColumnetsysPsePortPDType | read-only | current | Describes the detected PD type on this port. A value of legacy(1) - indicates that the PD is using a capacitive signature, which is pre-IEEE standard. A value … |
| 1.3.6.1.4.1.5624.1.2.50.1.5.1.1.4 | ColumnetsysPsePortCapability | read-only | current | This object indicates the IEEE Power over Ethernet standard this port supports. |
| 1.3.6.1.4.1.5624.1.2.50.1.5.1.1.5 | ColumnetsysPsePortCapabilitySelect | read-write | current | This object sets the port's power management capabilities based on the IEEE standard. ieee8023af (1) : IEEE Std 802.3af ieee8023at (2) : IEEE Std 802.3at Attem… |
| 1.3.6.1.4.1.5624.1.2.50.1.5.1.1.6 | ColumnetsysPsePortDetectionStatus | read-only | current | Describes the operational status of the port PD detection. A value of disabled(1)- indicates that the PSE State diagram is in the state DISABLED. A value of de… |
| 1.3.6.1.4.1.5624.1.2.50.2 | NodeetsysPsePowerAllocationConformance | |||
| 1.3.6.1.4.1.5624.1.2.50.2.1 | NodeetsysPsePowerAllocationGroups | |||
| 1.3.6.1.4.1.5624.1.2.50.2.1.1 | GroupetsysPsePowerAllocationControlGroup | current | Power over Ethernet Power Allocation Control group. | |
| 1.3.6.1.4.1.5624.1.2.50.2.1.2 | GroupetsysPseChassisPowerStatusGroup | current | Power over Ethernet Power Supply group. | |
| 1.3.6.1.4.1.5624.1.2.50.2.1.3 | GroupetsysPsePowerNotificationGroup | current | Power over Ethernet Power Redundancy Notifications group. | |
| 1.3.6.1.4.1.5624.1.2.50.2.1.4 | GroupetsysPseModulePowerManagementGroup | current | Power over Ethernet Module Power Budget Management group. | |
| 1.3.6.1.4.1.5624.1.2.50.2.1.5 | GroupetsysPsePortPowerManagementGroup | deprecated | Power over Ethernet Port Power Budget Management group. | |
| 1.3.6.1.4.1.5624.1.2.50.2.1.6 | GroupetsysPsePortPowerManagementGroupRev2 | current | Power over Ethernet Port Power Budget Management group. | |
| 1.3.6.1.4.1.5624.1.2.50.2.2 | NodeetsysPsePowerAllocationCompliances | |||
| 1.3.6.1.4.1.5624.1.2.50.2.2.1 | ComplianceetsysPsePowerAllocationCompliance | current | The compliance statement for devices that support manual power allocation. | |
| 1.3.6.1.4.1.5624.1.2.50.2.2.2 | ComplianceetsysPsePowerAllocationCompliance2 | deprecated | The compliance statement for devices that support power budgets. | |
| 1.3.6.1.4.1.5624.1.2.50.2.2.3 | ComplianceetsysPsePowerAllocationCompliance2Rev2 | current | The compliance statement for devices that support power budgets. |