MIB Viewer

HM2-DIAGNOSTIC-MIB

242 objects
Hirschmann Diagnostic MIB. Copyright (C) 2012. All Rights Reserved.
Imported Objects
HM2-DEVMGMT-MIBhm2IfacePhysIndex
HM2-PWRMGMT-MIBhm2PSID
HM2-TC-MIBhm2ConfigurationMibs HmEnabledStatus HmTimeSeconds1970
IF-MIBifIndex
SNMPv2-SMIInteger32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE Unsigned32
SNMPv2-TC-- RFC 2578 TEXTUAL-CONVENTION TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.248.11.22Identityhm2DiagnosticMibHirschmann Diagnostic MIB. Copyright (C) 2012. All Rights Reserved.
1.3.6.1.4.1.248.11.22.0Nodehm2DiagnosticMibNotifications
1.3.6.1.4.1.248.11.22.0.1Notificationhm2SigConStateChangeTrapcurrentThis trap is sent if the value of hm2SigConState changes its value.
1.3.6.1.4.1.248.11.22.0.2Notificationhm2DevMonStateChangeTrapcurrentThis trap is sent if the value of hm2DevMonState changes its value.
1.3.6.1.4.1.248.11.22.0.3Notificationhm2DevSecStateChangeTrapcurrentThis trap is sent if the value of hm2DevSecState changes its value.
1.3.6.1.4.1.248.11.22.0.4Notificationhm2DiagSelftestActionTrapcurrentThis trap is sent if a self-test action is performed and hm2DiagSelftestAction is configured to sendTrap(2).
1.3.6.1.4.1.248.11.22.0.5Notificationhm2DiagIfaceUtilizationTrapcurrentThis trap is sent if the value of hm2DiagIfaceUtilization exceeds or falls back below the interface utilization thresholds hm2DiagIfaceUtilizationAlarmConditio…
1.3.6.1.4.1.248.11.22.0.6Notificationhm2PortMonitorPortTrapcurrentThis trap is sent if the a port has been disabled by port disable action by port monitor.
1.3.6.1.4.1.248.11.22.0.7Notificationhm2DiagEgressIfaceUtilizationTrapcurrentThis trap is sent if the value of hm2DiagEgressIfaceUtilizationAlarmCondition is true.
1.3.6.1.4.1.248.11.22.1Nodehm2DiagnosticMibObjects
1.3.6.1.4.1.248.11.22.1.1Nodehm2DiagSelftestGroup
1.3.6.1.4.1.248.11.22.1.1.1Scalarhm2DiagSelftestRAMread-writecurrentControls RAM self-test on cold start of the device. When disabled the device booting time is reduced.
1.3.6.1.4.1.248.11.22.1.1.2Scalarhm2DiagSelftestBootTimeread-onlycurrentInternal boot time in Milliseconds until activating ports.
1.3.6.1.4.1.248.11.22.1.1.10Tablehm2DiagSelftestActionTablenot-accessiblecurrentDiag self test action group.
1.3.6.1.4.1.248.11.22.1.1.10.1Rowhm2DiagSelftestActionEntrynot-accessiblecurrentDiag self test action entry.
1.3.6.1.4.1.248.11.22.1.1.10.1.1Columnhm2DiagSelftestActionCauseread-onlycurrentThe area of the cause for the action the self-test wants to take.
1.3.6.1.4.1.248.11.22.1.1.10.1.2Columnhm2DiagSelftestActionread-writecurrentThe action that the self-test component should take. The cause is always logged to the system log, additionally a trap can be sent to the management station or…
1.3.6.1.4.1.248.11.22.1.2Nodehm2DiagBootGroup
1.3.6.1.4.1.248.11.22.1.2.1Scalarhm2BootSystemMonitorread-writecurrentEnable or disable the System Monitor access during the boot phase. Please note: If the System Monitor is disabled, it is possible to lose access to the device …
1.3.6.1.4.1.248.11.22.1.2.2Scalarhm2BootDefaultConfigOnErrorread-writecurrentEnable or disable loading of the default configuration in case there is any error loading the configuration during the boot phase. If disabled the system will …
1.3.6.1.4.1.248.11.22.1.2.3Scalarhm2BootConfigPushButtonread-writecurrentEnable or disable the push button functionality on the device.
1.3.6.1.4.1.248.11.22.1.3Nodehm2DiagDeviceMonitorGroup
1.3.6.1.4.1.248.11.22.1.3.1Nodehm2SignalContactGroup
1.3.6.1.4.1.248.11.22.1.3.1.1Tablehm2SigConCommonTablenot-accessiblecurrentThis table contains all variables to configure the behavior of the signalling contacts.
1.3.6.1.4.1.248.11.22.1.3.1.1.1Rowhm2SigConCommonEntrynot-accessiblecurrentThe entry of the hm2SigConConfigTable.
1.3.6.1.4.1.248.11.22.1.3.1.1.1.1Columnhm2SigConIDread-onlycurrentThis index is used to identify the associated signalling contact.
1.3.6.1.4.1.248.11.22.1.3.1.1.1.2Columnhm2SigConTrapEnableread-writecurrentDetermines whether a trap shall be sent or not, when the signal contact operating state changes.
1.3.6.1.4.1.248.11.22.1.3.1.1.1.3Columnhm2SigConTrapCauseread-onlycurrentThis object identifies the cause for a trap. The index of the entity which produces the trap is specified by hm2SigConTrapCauseIndex.
1.3.6.1.4.1.248.11.22.1.3.1.1.1.4Columnhm2SigConTrapCauseIndexread-onlycurrentThis attribute specifies the entity which produces the trap. power-supply: index of power-supply table link-failure: index of interface table temperature: 0 ex…
1.3.6.1.4.1.248.11.22.1.3.1.1.1.5Columnhm2SigConModeread-writecurrentThis attribute specifies the behavior of the relay contact. The factory settings for signal contact 1 is monitoring the correct operation of entries specified …
1.3.6.1.4.1.248.11.22.1.3.1.1.1.6Columnhm2SigConOperStateread-onlycurrentThis attribute shows the current operating state of the signal contact.
1.3.6.1.4.1.248.11.22.1.3.1.1.1.7Columnhm2SigConOperTimeStampread-onlycurrentThis attribute shows local system time (hm2SystemLocalTime) of the last hm2SigConOperState change.
1.3.6.1.4.1.248.11.22.1.3.1.1.1.8Columnhm2SigConManualActivateread-writecurrentWhen operating in manual mode, the signal contact state can be set by this attribute.
1.3.6.1.4.1.248.11.22.1.3.1.1.1.9Columnhm2SigConSenseLinkFailureread-writecurrentSets the monitoring of the network connection(s).
1.3.6.1.4.1.248.11.22.1.3.1.1.1.10Columnhm2SigConSenseTemperatureread-writecurrentSets the monitoring of the device temperature.
1.3.6.1.4.1.248.11.22.1.3.1.1.1.11Columnhm2SigConSenseFanread-writecurrentSets the monitoring of the device fan modules.
1.3.6.1.4.1.248.11.22.1.3.1.1.1.12Columnhm2SigConSenseModuleRemovalread-writecurrentSets the monitoring of module removal (platform dependant).
1.3.6.1.4.1.248.11.22.1.3.1.1.1.13Columnhm2SigConSenseExtNvmRemovalread-writecurrentSets the monitoring of the external non-volatile memory removal.
1.3.6.1.4.1.248.11.22.1.3.1.1.1.14Columnhm2SigConSenseExtNvmNotInSyncread-writecurrentSets the monitoring whether the external non-volatile memory is in sync with the configuration in NVRAM.
1.3.6.1.4.1.248.11.22.1.3.1.1.1.15Columnhm2SigConSenseRingRedundancyread-writecurrentSets the monitoring of the ring redundancy.
1.3.6.1.4.1.248.11.22.1.3.1.1.1.16Columnhm2SigConSenseEthernetLoopsread-writecurrentSets the monitoring for Ethernet loops.
1.3.6.1.4.1.248.11.22.1.3.1.1.1.17Columnhm2SigConSenseHumidityread-writecurrentSets the monitoring of the device humidity.
1.3.6.1.4.1.248.11.22.1.3.1.1.1.18Columnhm2SigConSenseStpPortBlockread-writecurrentSets the monitoring for STP loops.
1.3.6.1.4.1.248.11.22.1.3.1.2Tablehm2SigConPSTablenot-accessiblecurrentThis table contains the configuration of all power supply states.
1.3.6.1.4.1.248.11.22.1.3.1.2.1Rowhm2SigConPSEntrynot-accessiblecurrentThe entry of the hm2SigConPSTable.
1.3.6.1.4.1.248.11.22.1.3.1.2.1.1Columnhm2SigConSensePSStateread-writecurrentSets the monitoring of the power supply state.
1.3.6.1.4.1.248.11.22.1.3.1.3Tablehm2SigConInterfaceTablenot-accessiblecurrentThis table contains all variables to mask an alarm for the signalling relay, produced by a link. The index for a link corresponds with ifIndex. The table is al…
1.3.6.1.4.1.248.11.22.1.3.1.3.1Rowhm2SigConInterfaceEntrynot-accessiblecurrentThe entry of the hm2SigConLinkTable.
1.3.6.1.4.1.248.11.22.1.3.1.3.1.1Columnhm2SigConSenseIfLinkAlarmread-writecurrentIndicates whether an alarm for the signalling relay of the associated link will be produced or not, so you can mask the value of ifMauMediaAvailable.
1.3.6.1.4.1.248.11.22.1.3.1.4Tablehm2SigConModuleTablenot-accessiblecurrentThis table contains all variables to mask a module for the signaling relay. The index for a module corresponds with the slot number.
1.3.6.1.4.1.248.11.22.1.3.1.4.1Rowhm2SigConModuleEntrynot-accessiblecurrentThe entry of the hm2SigConModuleTable.
1.3.6.1.4.1.248.11.22.1.3.1.4.1.1Columnhm2SigConModIDread-onlycurrentThis index is used to identify the associated module.
1.3.6.1.4.1.248.11.22.1.3.1.4.1.2Columnhm2SigConSenseModuleread-writecurrentIndicates whether an alarm for the signalling relay of the associated module will be produced or not.
1.3.6.1.4.1.248.11.22.1.3.1.5Tablehm2SigConFanModuleTablenot-accessiblecurrentThis table contains all variables to mask a fan module for the signaling relay. The index for a module corresponds with the module number.
1.3.6.1.4.1.248.11.22.1.3.1.5.1Rowhm2SigConFanModuleEntrynot-accessiblecurrentThe entry of the hm2SigConFanModuleTable.
1.3.6.1.4.1.248.11.22.1.3.1.5.1.1Columnhm2SigConFanModIDread-onlycurrentThis index is used to identify the associated fan module.
1.3.6.1.4.1.248.11.22.1.3.1.5.1.2Columnhm2SigConSenseFanModuleread-writecurrentIndicates whether an alarm for the signalling relay of the associated fan module will be produced or not.
1.3.6.1.4.1.248.11.22.1.3.1.10Tablehm2SigConStatusTablenot-accessiblecurrentThis table shows the current monitored entities for which there is a trap cause (hm2SigConTrapCause) active.
1.3.6.1.4.1.248.11.22.1.3.1.10.1Rowhm2SigConStatusEntrynot-accessiblecurrentThe entry of the hm2SigConStatusTable.
1.3.6.1.4.1.248.11.22.1.3.1.10.1.1Columnhm2SigConStatusIndexnot-accessiblecurrentThis index is used to identify the occured event.
1.3.6.1.4.1.248.11.22.1.3.1.10.1.2Columnhm2SigConStatusTimeStampread-onlycurrentThis attribute shows the local system time (hm2SystemLocalTime) of occuration the event.
1.3.6.1.4.1.248.11.22.1.3.1.10.1.3Columnhm2SigConStatusTrapCauseread-onlycurrentThis object identifies the cause for a trap. The index of the entity which produces the trap is specified by hm2SigConTrapCauseIndex.
1.3.6.1.4.1.248.11.22.1.3.1.10.1.4Columnhm2SigConStatusTrapCauseIndexread-onlycurrentThis attribute specifies the entity which produces the trap. power-supply: index of power-supply table link-failure: index of interface table temperature: 0 ex…
1.3.6.1.4.1.248.11.22.1.3.2Nodehm2DeviceMonitorGroup
1.3.6.1.4.1.248.11.22.1.3.2.1Tablehm2DevMonCommonTablenot-accessiblecurrentThis table contains all variables to configure the behavior of the signalling contacts.
1.3.6.1.4.1.248.11.22.1.3.2.1.1Rowhm2DevMonCommonEntrynot-accessiblecurrentThe entry of the hm2DevMonConfigTable.
1.3.6.1.4.1.248.11.22.1.3.2.1.1.1Columnhm2DevMonIDread-onlycurrentThis index is used to identify the associated device monitoring group. Currently only one group is supported
1.3.6.1.4.1.248.11.22.1.3.2.1.1.2Columnhm2DevMonTrapEnableread-writecurrentDetermines whether a trap shall be sent or not when the signal contact operating state changes.
1.3.6.1.4.1.248.11.22.1.3.2.1.1.3Columnhm2DevMonTrapCauseread-onlycurrentThis object identifies the cause for a trap. The index of the entity which produces the trap is specified by hm2DevMonTrapCauseIndex.
1.3.6.1.4.1.248.11.22.1.3.2.1.1.4Columnhm2DevMonTrapCauseIndexread-onlycurrentThis attribute specifies the entity which produces the trap. power-supply: index of power supply table link-failure: index of interface table temperature: 0 ex…
1.3.6.1.4.1.248.11.22.1.3.2.1.1.5Columnhm2DevMonOperStateread-onlycurrentThis attribute shows the current operating state of the signal contact.
1.3.6.1.4.1.248.11.22.1.3.2.1.1.6Columnhm2DevMonOperTimeStampread-onlycurrentThis attribute shows the local system time (hm2SystemLocalTime) of the last hm2DevMonOperState change.
1.3.6.1.4.1.248.11.22.1.3.2.1.1.7Columnhm2DevMonSenseLinkFailureread-writecurrentSets the monitoring of the network connection(s).
1.3.6.1.4.1.248.11.22.1.3.2.1.1.8Columnhm2DevMonSenseTemperatureread-writecurrentSets the monitoring of the device temperature.
1.3.6.1.4.1.248.11.22.1.3.2.1.1.9Columnhm2DevMonSenseFanread-writecurrentSets the monitoring of the device fan modules.
1.3.6.1.4.1.248.11.22.1.3.2.1.1.10Columnhm2DevMonSenseModuleRemovalread-writecurrentSets the monitoring of module removal (platform dependent).
1.3.6.1.4.1.248.11.22.1.3.2.1.1.11Columnhm2DevMonSenseExtNvmRemovalread-writecurrentSets the monitoring of the external non-volatile memory removal.
1.3.6.1.4.1.248.11.22.1.3.2.1.1.12Columnhm2DevMonSenseExtNvmNotInSyncread-writecurrentSets the monitoring whether the external non-volatile memory is in sync with the configuration in NVRAM.
1.3.6.1.4.1.248.11.22.1.3.2.1.1.13Columnhm2DevMonSenseRingRedundancyread-writecurrentSets the monitoring of the ring redundancy.
1.3.6.1.4.1.248.11.22.1.3.2.1.1.14Columnhm2DevMonSenseHumidityread-writecurrentSets the monitoring of the device humidity.
1.3.6.1.4.1.248.11.22.1.3.2.1.1.15Columnhm2DevMonSenseStpPortBlockread-writecurrentSets the monitoring whether a port was blocked by STP.
1.3.6.1.4.1.248.11.22.1.3.2.2Tablehm2DevMonPSTablenot-accessiblecurrentThis table contains the configuration of all power supply states.
1.3.6.1.4.1.248.11.22.1.3.2.2.1Rowhm2DevMonPSEntrynot-accessiblecurrentThe entry of the hm2DevMonPSTable.
1.3.6.1.4.1.248.11.22.1.3.2.2.1.1Columnhm2DevMonSensePSStateread-writecurrentSets the monitoring of the power supply state.
1.3.6.1.4.1.248.11.22.1.3.2.3Tablehm2DevMonInterfaceTablenot-accessiblecurrentThis table contains all variables to mask an alarm for the signalling relay, produced by a link. The index for a link corresponds with ifIndex. The table is al…
1.3.6.1.4.1.248.11.22.1.3.2.3.1Rowhm2DevMonInterfaceEntrynot-accessiblecurrentThe entry of the hm2DevMonLinkTable.
1.3.6.1.4.1.248.11.22.1.3.2.3.1.1Columnhm2DevMonSenseIfLinkAlarmread-writecurrentIndicates whether an alarm for the signalling relay of the associated link will be produced or not, so you can mask the value of ifMauMediaAvailable.
1.3.6.1.4.1.248.11.22.1.3.2.4Tablehm2DevMonModuleTablenot-accessiblecurrentThis table contains all variables to mask a module for the device status. The index for a module corresponds with the slot number.
1.3.6.1.4.1.248.11.22.1.3.2.4.1Rowhm2DevMonModuleEntrynot-accessiblecurrentThe entry of the hm2DevMonModuleTable.
1.3.6.1.4.1.248.11.22.1.3.2.4.1.1Columnhm2DevMonModIDread-onlycurrentThis index is used to identify the associated module.
1.3.6.1.4.1.248.11.22.1.3.2.4.1.2Columnhm2DevMonSenseModuleread-writecurrentIndicates whether an alarm for the device status of the associated module will be produced or not.
1.3.6.1.4.1.248.11.22.1.3.2.5Tablehm2DevMonFanModuleTablenot-accessiblecurrentThis table contains all variables to mask a fan module for the device status. The index for a module corresponds with the module number.
1.3.6.1.4.1.248.11.22.1.3.2.5.1Rowhm2DevMonFanModuleEntrynot-accessiblecurrentThe entry of the hm2DevMonFanModuleTable.
1.3.6.1.4.1.248.11.22.1.3.2.5.1.1Columnhm2DevMonFanModIDread-onlycurrentThis index is used to identify the associated fan module.
1.3.6.1.4.1.248.11.22.1.3.2.5.1.2Columnhm2DevMonSenseFanModuleread-writecurrentIndicates whether an alarm for the device status of the associated fan module will be produced or not.
1.3.6.1.4.1.248.11.22.1.3.2.10Tablehm2DevMonStatusTablenot-accessiblecurrentThis table shows the current monitored entities in the hm2DeviceMonitorGroup for which there is a trap cause (hm2DevMonStatusTrapCause) active.
1.3.6.1.4.1.248.11.22.1.3.2.10.1Rowhm2DevMonStatusEntrynot-accessiblecurrentThe entry of the hm2DevMonStatusTable.
1.3.6.1.4.1.248.11.22.1.3.2.10.1.1Columnhm2DevMonStatusIndexnot-accessiblecurrentThis index is used to identify the occured event.
1.3.6.1.4.1.248.11.22.1.3.2.10.1.2Columnhm2DevMonStatusTimeStampread-onlycurrentThis attribute shows the local system time (hm2SystemLocalTime) of occuration the event.
1.3.6.1.4.1.248.11.22.1.3.2.10.1.3Columnhm2DevMonStatusTrapCauseread-onlycurrentThis object identifies the cause for a trap. The index of the entity which produces the trap is specified by hm2DevMonTrapCauseIndex.
1.3.6.1.4.1.248.11.22.1.3.2.10.1.4Columnhm2DevMonStatusTrapCauseIndexread-onlycurrentThis attribute specifies the entity which produces the trap. power-supply: index of power supply table link-failure: index of interface table temperature: 0 ex…
1.3.6.1.4.1.248.11.22.1.3.3Nodehm2DeviceSecurityGroup
1.3.6.1.4.1.248.11.22.1.3.3.1Nodehm2DevSecConfigGroup
1.3.6.1.4.1.248.11.22.1.3.3.1.1Scalarhm2DevSecTrapEnableread-writecurrentDetermines whether a trap shall be sent or not, when the device security operating state changes.
1.3.6.1.4.1.248.11.22.1.3.3.1.2Scalarhm2DevSecTrapCauseread-onlycurrentThis object identifies the cause for a trap. The index of the entity which produces the trap is specified by hm2DevMonTrapCauseIndex.
1.3.6.1.4.1.248.11.22.1.3.3.1.3Scalarhm2DevSecTrapCauseIndexread-onlycurrentThis attribute specifies the entity which produces the trap. ext-nvm-update-enabled: (1) sd, (2) usb, (3) serial (not supported yet) no-link: index of interfac…
1.3.6.1.4.1.248.11.22.1.3.3.1.4Scalarhm2DevSecOperStateread-onlycurrentThis attribute shows the current operating state of the signal contact.
1.3.6.1.4.1.248.11.22.1.3.3.1.5Scalarhm2DevSecOperTimeStampread-onlycurrentThis attribute shows the local system time (hm2SystemLocalTime) of the last hm2DevSecOperState change.
1.3.6.1.4.1.248.11.22.1.3.3.1.6Scalarhm2DevSecSensePasswordChangeread-writecurrentEnable or disable to check if default passwords for 'user' and 'admin' are not changed.
1.3.6.1.4.1.248.11.22.1.3.3.1.7Scalarhm2DevSecSensePasswordMinLengthread-writecurrentEnable or disable to check if configured minimum password length is < 8 characters.
1.3.6.1.4.1.248.11.22.1.3.3.1.8Scalarhm2DevSecSensePasswordStrengthNotConfiguredread-writecurrentEnable or disable minimum password strength to check if (1 uppercase, 1 lowercase, 1 number, 1 non-alphanumeric) is not configured.
1.3.6.1.4.1.248.11.22.1.3.3.1.9Scalarhm2DevSecSenseBypassPasswordStrengthread-writecurrentEnable or disable to check if at least one user is configured to bypass strength check.
1.3.6.1.4.1.248.11.22.1.3.3.1.10Scalarhm2DevSecSenseTelnetEnabledread-writecurrentEnable or disable to check if telnet is enabled on the switch.
1.3.6.1.4.1.248.11.22.1.3.3.1.11Scalarhm2DevSecSenseHttpEnabledread-writecurrentEnable or disable to check if HTTP is enabled on the switch.
1.3.6.1.4.1.248.11.22.1.3.3.1.12Scalarhm2DevSecSenseSnmpUnsecureread-writecurrentEnable or disable to check if SNMP v1/v2 is enabled or v3 encryption is disabled.
1.3.6.1.4.1.248.11.22.1.3.3.1.13Scalarhm2DevSecSenseSysmonEnabledread-writecurrentEnable or disable to check if sysmon1 access is not disabled.
1.3.6.1.4.1.248.11.22.1.3.3.1.14Scalarhm2DevSecSenseExtNvmUpdateEnabledread-writecurrentEnable or disable to check if external non-volatile memory update is not disabled.
1.3.6.1.4.1.248.11.22.1.3.3.1.15Scalarhm2DevSecSenseNoLinkEnabledread-writecurrentEnable or disable to check if at least one port has no link but admin state is up.
1.3.6.1.4.1.248.11.22.1.3.3.1.16Scalarhm2DevSecSenseHiDiscoveryEnabledread-writecurrentEnable or disable to check if HiDiscovery is enabled and the mode is 'read-write'.
1.3.6.1.4.1.248.11.22.1.3.3.1.17Scalarhm2DevSecSenseExtNvmConfigLoadUnsecureread-writecurrentEnable or disable to check if the configuration load from external NVM is unsecure. (The configuration priority of the external NVM is set to 'first', 'second'…
1.3.6.1.4.1.248.11.22.1.3.3.1.18Scalarhm2DevSecSenseIec61850MmsEnabledread-writecurrentEnable or disable to check if IEC 61850 MMS is enabled on the switch.
1.3.6.1.4.1.248.11.22.1.3.3.1.19Scalarhm2DevSecSenseHttpsCertificateWarningread-writecurrentEnable or disable to check for the presence of the auto generated self-signed HTTPS certificate.
1.3.6.1.4.1.248.11.22.1.3.3.1.20Scalarhm2DevSecSenseModbusTcpEnabledread-writecurrentEnable or disable to check if Modbus/TCP server is enabled on the switch.
1.3.6.1.4.1.248.11.22.1.3.3.1.21Scalarhm2DevSecSenseEtherNetIpEnabledread-writecurrentEnable or disable to check if EtherNet/IP protocol is enabled on the switch.
1.3.6.1.4.1.248.11.22.1.3.3.1.22Scalarhm2DevSecSenseProfinetIOEnabledread-writecurrentEnable or disable to check if ProfinetIO protocol is enabled on the switch.
1.3.6.1.4.1.248.11.22.1.3.3.1.23Scalarhm2DevSecSensePMLDisabledread-writecurrentEnable or disable to check if Port MAC Locking is disabled on the switch.
1.3.6.1.4.1.248.11.22.1.3.3.2Tablehm2DevSecInterfaceTablenot-accessiblecurrentThis table contains all variables to mask an alarm for the signalling relay, produced by a link. The index for a link corresponds with ifIndex. The table is al…
1.3.6.1.4.1.248.11.22.1.3.3.2.1Rowhm2DevSecInterfaceEntrynot-accessiblecurrentThe entry of the hm2DevSecLinkTable.
1.3.6.1.4.1.248.11.22.1.3.3.2.1.1Columnhm2DevSecSenseIfNoLinkread-writecurrentPort has no link but admin state is up
1.3.6.1.4.1.248.11.22.1.3.3.10Tablehm2DevSecStatusTablenot-accessiblecurrentThis table shows the current monitored entities in the hm2DevSecConfigGroup for which there is a trap cause (hm2DevSecStatusTrapCause) active.
1.3.6.1.4.1.248.11.22.1.3.3.10.1Rowhm2DevSecStatusEntrynot-accessiblecurrentThe entry of the hm2DevSecStatusTable.
1.3.6.1.4.1.248.11.22.1.3.3.10.1.1Columnhm2DevSecStatusIndexnot-accessiblecurrentThis index is used to identify the occured event.
1.3.6.1.4.1.248.11.22.1.3.3.10.1.2Columnhm2DevSecStatusTimeStampread-onlycurrentThis attribute shows the local system time (hm2SystemLocalTime) of occuration the event.
1.3.6.1.4.1.248.11.22.1.3.3.10.1.3Columnhm2DevSecStatusTrapCauseread-onlycurrentThis object identifies the cause for a trap. The index of the entity which produces the trap is specified by hm2DevSecTrapCauseIndex.
1.3.6.1.4.1.248.11.22.1.3.3.10.1.4Columnhm2DevSecStatusTrapCauseIndexread-onlycurrentThis attribute specifies the entity which produces the trap. ext-nvm-update-enabled: (1) sd, (2) usb, (3) serial (not supported yet) no-link: index of interfac…
1.3.6.1.4.1.248.11.22.1.4Nodehm2DiagLedGroup
1.3.6.1.4.1.248.11.22.1.4.1Tablehm2LedGlobalTablenot-accessiblecurrent.
1.3.6.1.4.1.248.11.22.1.4.1.1Rowhm2LedGlobalEntrynot-accessiblecurrent.
1.3.6.1.4.1.248.11.22.1.4.1.1.1Columnhm2LedGlobalLedTypenot-accessiblecurrent.
1.3.6.1.4.1.248.11.22.1.4.1.1.2Columnhm2LedGlobalStatusread-onlycurrent.
1.3.6.1.4.1.248.11.22.1.4.2Tablehm2LedPortTablenot-accessiblecurrent.
1.3.6.1.4.1.248.11.22.1.4.2.1Rowhm2LedPortEntrynot-accessiblecurrent.
1.3.6.1.4.1.248.11.22.1.4.2.1.1Columnhm2LedPortStatusread-onlycurrent.
1.3.6.1.4.1.248.11.22.1.4.2.1.2Columnhm2LedPortPoeStatusread-onlycurrent.
1.3.6.1.4.1.248.11.22.1.4.2.1.3Columnhm2LedPortSignalingread-writecurrentEnable for LED port signaling.
1.3.6.1.4.1.248.11.22.1.4.3Nodehm2LedControlGroup
1.3.6.1.4.1.248.11.22.1.4.3.1Scalarhm2LedPortModeread-writecurrentSwitch LED signalling between the port LEDs on front side (port panel) and the port LEDs on the back side (service panel) of the device.
1.3.6.1.4.1.248.11.22.1.5Nodehm2DiagIfaceUtilizationGroup
1.3.6.1.4.1.248.11.22.1.5.1Tablehm2DiagIfaceUtilizationTablenot-accessiblecurrentThis table contains variables for each interface of the switch.
1.3.6.1.4.1.248.11.22.1.5.1.1Rowhm2DiagIfaceUtilizationEntrynot-accessiblecurrentThe entry of the hm2DiagIfaceUtilizationTable.
1.3.6.1.4.1.248.11.22.1.5.1.1.1Columnhm2DiagIfaceUtilizationread-onlycurrentThe best estimate of the mean physical layer network utilization on this interface during the last sampling interval, in hundredth of one percent. The first hi…
1.3.6.1.4.1.248.11.22.1.5.1.1.2Columnhm2DiagIfaceUtilizationControlIntervalread-writecurrentThe interval in seconds over which the data is sampled for hm2DiagIfaceUtilization. This interval can be any number of seconds between 1 and 3600 (1 hour). The…
1.3.6.1.4.1.248.11.22.1.5.1.1.3Columnhm2DiagIfaceUtilizationAlarmLowerThresholdread-writecurrentSurveys the interface utilization hm2DiagIfaceUtilization and generates an alarm for this interfaces, if the utilization value is below the given limit. A valu…
1.3.6.1.4.1.248.11.22.1.5.1.1.4Columnhm2DiagIfaceUtilizationAlarmUpperThresholdread-writecurrentSurveys the interface utilization hm2DiagIfaceUtilization and generates an alarm for this interfaces, if the given limit is exceeded. A value of 0 disables the…
1.3.6.1.4.1.248.11.22.1.5.1.1.5Columnhm2DiagIfaceUtilizationAlarmConditionread-onlycurrentThe alarm condition is given (true), if the given hm2DiagIfaceUtilizationAlarmUpperThreshold limit is exceeded by the interface utilization or if the utilizati…
1.3.6.1.4.1.248.11.22.1.5.2Tablehm2DiagEgressIfaceUtilizationTablenot-accessiblecurrentThis table contains egress variables for each interface of the switch.
1.3.6.1.4.1.248.11.22.1.5.2.1Rowhm2DiagEgressIfaceUtilizationEntrynot-accessiblecurrentThe entry of the hm2DiagEgressIfaceUtilizationTable.
1.3.6.1.4.1.248.11.22.1.5.2.1.1Columnhm2DiagEgressIfaceUtilizationread-onlycurrentThe best estimate of the mean physical layer network egress utilization on this interface during the last sampling interval, in hundredth of one percent. The f…
1.3.6.1.4.1.248.11.22.1.5.2.1.2Columnhm2DiagEgressIfaceUtilizationControlIntervalread-writecurrentThe interval in seconds over which the egress data is sampled for hm2DiagEgressIfaceUtilization. This interval can be any number of seconds between 1 and 3600 …
1.3.6.1.4.1.248.11.22.1.5.2.1.3Columnhm2DiagEgressIfaceUtilizationAlarmLowerThresholdread-writecurrentSurveys the egress interface utilization hm2DiagEgressIfaceUtilization and generates an alarm for this interface, if the utilization value is below the given l…
1.3.6.1.4.1.248.11.22.1.5.2.1.4Columnhm2DiagEgressIfaceUtilizationAlarmUpperThresholdread-writecurrentSurveys the egress interface utilization hm2DiagEgressIfaceUtilization and generates an alarm for this interface, if the given limit is exceeded. A value of 0 …
1.3.6.1.4.1.248.11.22.1.5.2.1.5Columnhm2DiagEgressIfaceUtilizationAlarmConditionread-onlycurrentThe alarm condition is given (true), if the given hm2DiagEgressIfaceUtilizationAlarmUpperThreshold limit is exceeded by the egress interface utilization or if …
1.3.6.1.4.1.248.11.22.1.6Nodehm2DiagCableTesterGroup
1.3.6.1.4.1.248.11.22.1.6.1Scalarhm2DiagCableTesterStatusread-writecurrentStatus of the Virtual Cable Tester active(1) - Cable testing is in progress. Set to this value to start the test. success(2) - A successful test was performed.…
1.3.6.1.4.1.248.11.22.1.6.2Scalarhm2DiagCableTesterIfIndexread-writecurrentDetermines on which port to perform the cable test. Limited to copper based ports.
1.3.6.1.4.1.248.11.22.1.6.10Tablehm2DiagCableTesterCableTablenot-accessiblecurrentThis table contains variables for each pair of the cable.
1.3.6.1.4.1.248.11.22.1.6.10.1Rowhm2DiagCableTesterCableEntrynot-accessiblecurrentThe entry of the hm2DiagCableTesterCableTable.
1.3.6.1.4.1.248.11.22.1.6.10.1.1Columnhm2DiagCableTesterCablePairnot-accessiblecurrentIndex of the hm2DiagCableTesterCableTable. If a PHY does not support the measurement per pair, the first index is used to show the values.
1.3.6.1.4.1.248.11.22.1.6.10.1.2Columnhm2DiagCableTesterCableStatusread-onlycurrentIndicates the results of the Cable Test. normal(1) - The cable is working correctly. open(2) - The cable is disconnected or there is a faulty connector. short(…
1.3.6.1.4.1.248.11.22.1.6.10.1.3Columnhm2DiagCableTesterCableMinimumLengthread-onlycurrentThe estimated length of the cable in meters. This value indicates the shortest length estimated. This object will return 0 if hm2DiagCableTesterStatus is not s…
1.3.6.1.4.1.248.11.22.1.6.10.1.4Columnhm2DiagCableTesterCableMaximumLengthread-onlycurrentThe estimated length of the cable in meters. This value indicates the longest length estimated. This object will return 0 if hm2DiagCableTesterStatus is not su…
1.3.6.1.4.1.248.11.22.1.6.10.1.5Columnhm2DiagCableTesterCableFailureLocationread-onlycurrentThe estimated distance in meters from the end of the cable to the failure location. This object will return 0 if hm2DiagCableTesterStatus is not success(2).
1.3.6.1.4.1.248.11.22.1.7Nodehm2PortMonitorGroup
1.3.6.1.4.1.248.11.22.1.7.1Scalarhm2PortMonitorAdminModeread-writecurrentGlobal switch to enable / disable the port state actions, which are performed if a condition becomes true
1.3.6.1.4.1.248.11.22.1.7.2Tablehm2PortMonitorIntfTablenot-accessiblecurrentPort state mode interface table.
1.3.6.1.4.1.248.11.22.1.7.2.1Rowhm2PortMonitorIntfEntrynot-accessiblecurrentPort state mode interface entry.
1.3.6.1.4.1.248.11.22.1.7.2.1.2Columnhm2PortMonitorIntfResetread-writecurrentPort monitor interface reset.
1.3.6.1.4.1.248.11.22.1.7.2.1.3Columnhm2PortMonitorIntfActionread-writecurrentInterface link disable state.
1.3.6.1.4.1.248.11.22.1.7.3Nodehm2PortMonitorConditionGroup
1.3.6.1.4.1.248.11.22.1.7.3.1Tablehm2PortMonitorConditionIntfTablenot-accessiblecurrentPort state condition interface table.
1.3.6.1.4.1.248.11.22.1.7.3.1.1Rowhm2PortMonitorConditionIntfEntrynot-accessiblecurrentPort state action interface entry.
1.3.6.1.4.1.248.11.22.1.7.3.1.1.1Columnhm2PortMonitorConditionFieldread-onlycurrentCondition type field.
1.3.6.1.4.1.248.11.22.1.7.3.1.1.2Columnhm2PortMonitorConditionLinkFlapModeread-writecurrentInterface link flap mode.
1.3.6.1.4.1.248.11.22.1.7.3.1.1.3Columnhm2PortMonitorConditionCrcFragmentsModeread-writecurrentInterface CrcFragments mode.
1.3.6.1.4.1.248.11.22.1.7.3.1.1.4Columnhm2PortMonitorConditionDuplexMismatchDetectionModeread-writecurrentInterface duplex mismatch detection mode.
1.3.6.1.4.1.248.11.22.1.7.3.1.1.5Columnhm2PortMonitorConditionOverloadDetectionModeread-writecurrentInterface Overload Detection mode.
1.3.6.1.4.1.248.11.22.1.7.3.1.1.6Columnhm2PortMonitorConditionSpeedDuplexModeread-writecurrentInterface Speed and Duplex monitor mode.
1.3.6.1.4.1.248.11.22.1.7.3.2Nodehm2PortMonitorConditionLinkFlapGroup
1.3.6.1.4.1.248.11.22.1.7.3.2.1Tablehm2PortMonitorConditionLinkFlapIntfTablenot-accessiblecurrentPort condition link flap interface table.
1.3.6.1.4.1.248.11.22.1.7.3.2.1.1Rowhm2PortMonitorConditionLinkFlapIntfEntrynot-accessiblecurrentPort condition link flap interface entry.
1.3.6.1.4.1.248.11.22.1.7.3.2.1.1.1Columnhm2PortMonitorConditionLinkFlapIntervalread-writecurrentMeasure interval in seconds (1-180s) for link flap detection.
1.3.6.1.4.1.248.11.22.1.7.3.2.1.1.2Columnhm2PortMonitorConditionLinkFlapCountread-writecurrentLink flap counter (1-100).
1.3.6.1.4.1.248.11.22.1.7.3.2.1.1.3Columnhm2PortMonitorConditionLinkFlapCountIntervalread-onlycurrentLink flap count that occured in last interval.
1.3.6.1.4.1.248.11.22.1.7.3.2.1.1.4Columnhm2PortMonitorConditionLinkFlapCountTotalread-onlycurrentTotal link flap count.
1.3.6.1.4.1.248.11.22.1.7.3.3Nodehm2PortMonitorConditionCrcFragmentsGroup
1.3.6.1.4.1.248.11.22.1.7.3.3.1Tablehm2PortMonitorConditionCrcFragmentsIntfTablenot-accessiblecurrentPort condition CrcFragments interface table.
1.3.6.1.4.1.248.11.22.1.7.3.3.1.1Rowhm2PortMonitorConditionCrcFragmentsIntfEntrynot-accessiblecurrentPort condition CrcFragments interface entry.
1.3.6.1.4.1.248.11.22.1.7.3.3.1.1.1Columnhm2PortMonitorConditionCrcFragmentsIntervalread-writecurrentMeasure interval in seconds (5-180s) for CrcFragments detection.
1.3.6.1.4.1.248.11.22.1.7.3.3.1.1.2Columnhm2PortMonitorConditionCrcFragmentsCountread-writecurrentCrcFragments counter (1-1000000).
1.3.6.1.4.1.248.11.22.1.7.3.3.1.1.3Columnhm2PortMonitorConditionCrcFragmentsCountIntervalread-onlycurrentCrcFragments count that occured in last interval.
1.3.6.1.4.1.248.11.22.1.7.3.3.1.1.4Columnhm2PortMonitorConditionCrcFragmentsCountTotalread-onlycurrentTotal CrcFragments count.
1.3.6.1.4.1.248.11.22.1.7.3.4Nodehm2PortMonitorConditionOverloadDetectionGroup
1.3.6.1.4.1.248.11.22.1.7.3.4.1Tablehm2PortMonitorConditionOvldDetIntfTablenot-accessiblecurrentPort condition overload detection interface table.
1.3.6.1.4.1.248.11.22.1.7.3.4.1.1Rowhm2PortMonitorConditionOvldDetIntfEntrynot-accessiblecurrentPort condition overload detection interface entry.
1.3.6.1.4.1.248.11.22.1.7.3.4.1.1.1Columnhm2PortMonitorConditionOvldDetTrfcTyperead-writecurrentOverload detection condition traffic type.
1.3.6.1.4.1.248.11.22.1.7.3.4.1.1.2Columnhm2PortMonitorConditionOvldDetTholdTyperead-writecurrentOverload detection conditon threshold type.
1.3.6.1.4.1.248.11.22.1.7.3.4.1.1.3Columnhm2PortMonitorConditionOvldDetLwrTholdValread-writecurrentOverload detection condition lower threshold value.
1.3.6.1.4.1.248.11.22.1.7.3.4.1.1.4Columnhm2PortMonitorConditionOvldDetUprTholdValread-writecurrentOverload detection condition upper threshold value.
1.3.6.1.4.1.248.11.22.1.7.3.4.1.1.5Columnhm2PortMonitorConditionOvldDetIntvlread-writecurrentMeasure interval in seconds (1-20s) for overload detection.
1.3.6.1.4.1.248.11.22.1.7.3.4.1.1.6Columnhm2PortMonitorConditionOvldDetPkgCntAllread-onlycurrentAll package count from last interval.
1.3.6.1.4.1.248.11.22.1.7.3.4.1.1.7Columnhm2PortMonitorConditionOvldDetPkgCntBCread-onlycurrentBroadcast package count from last interval.
1.3.6.1.4.1.248.11.22.1.7.3.4.1.1.8Columnhm2PortMonitorConditionOvldDetPkgCntMCread-onlycurrentOverload detection condition lower threshold value.
1.3.6.1.4.1.248.11.22.1.7.3.4.1.1.9Columnhm2PortMonitorConditionOvldDetPkgCntKbitread-onlycurrentOverload detection condition lower threshold value.
1.3.6.1.4.1.248.11.22.1.7.3.5Nodehm2PortMonitorConditionSpeedDuplexGroup
1.3.6.1.4.1.248.11.22.1.7.3.5.1Tablehm2PortMonitorConditionSpeedDuplexTablenot-accessiblecurrentPort condition speed-duplex interface table.
1.3.6.1.4.1.248.11.22.1.7.3.5.1.1Rowhm2PortMonitorConditionSpeedDuplexEntrynot-accessiblecurrentPort condition speed-duplex interface entry.
1.3.6.1.4.1.248.11.22.1.7.3.5.1.1.1Columnhm2PortMonitorConditionSpeedDuplexValueread-writecurrentSpeed and duplex combination allowed by port-monitor.
1.3.6.1.4.1.248.11.22.1.7.4Identityhm2KbpsUnitTrafficTypeInvalidcurrentInterface {0}: 'Kbps' unit can only be used for traffic type 'all'.
1.3.6.1.4.1.248.11.22.1.8Nodehm2DiagResourcesGroup
1.3.6.1.4.1.248.11.22.1.8.1Scalarhm2DiagEnableMeasurementread-writecurrentEnable or disable the resources measurement If disabled, the task - needed for measurement - is also deleted.
1.3.6.1.4.1.248.11.22.1.8.10Nodehm2DiagCpuResourcesGroup
1.3.6.1.4.1.248.11.22.1.8.10.1Scalarhm2DiagCpuUtilizationread-onlycurrentThe current cpu utilization of the device in percent.
1.3.6.1.4.1.248.11.22.1.8.10.2Scalarhm2DiagCpuAverageUtilizationread-onlycurrentThe average cpu utilization of the device in percent, max. measured over the last 30 minutes.
1.3.6.1.4.1.248.11.22.1.8.10.3Scalarhm2DiagCpuRunningProcessesread-onlycurrentThe current number of processes running.
1.3.6.1.4.1.248.11.22.1.8.10.4Scalarhm2DiagCpuMaxRunningProcessesread-onlycurrentThe maximum number of processes running, max. since the last 30 minutes.
1.3.6.1.4.1.248.11.22.1.8.11Nodehm2DiagMemoryResourcesGroup
1.3.6.1.4.1.248.11.22.1.8.11.1Scalarhm2DiagMemoryRamAllocatedread-onlycurrentThe current allocated RAM of the device in kBytes.
1.3.6.1.4.1.248.11.22.1.8.11.2Scalarhm2DiagMemoryRamFreeread-onlycurrentThe current free RAM of the device in kBytes.
1.3.6.1.4.1.248.11.22.1.8.11.3Scalarhm2DiagMemoryRamAllocatedAverageread-onlycurrentThe average allocated RAM of the device in kBytes, measured over the last 30 minutes.
1.3.6.1.4.1.248.11.22.1.8.11.4Scalarhm2DiagMemoryRamFreeAverageread-onlycurrentThe average free RAM of the device in kBytes, measured over the last 30 minutes.
1.3.6.1.4.1.248.11.22.1.8.11.10Scalarhm2DiagMemoryRawFlashMainAllocatedread-onlycurrentThe current allocated flash memory for the main software image in kBytes.
1.3.6.1.4.1.248.11.22.1.8.11.11Scalarhm2DiagMemoryRawFlashMainFreeread-onlycurrentThe current free flash memory for the main software image in kBytes.
1.3.6.1.4.1.248.11.22.1.8.11.12Scalarhm2DiagMemoryFlashFileSystemAllocatedread-onlycurrentThe current allocated memory within the flash file system in kBytes.
1.3.6.1.4.1.248.11.22.1.8.11.13Scalarhm2DiagMemoryFlashFileSystemFreeread-onlycurrentThe current free memory within the flash file system in kBytes.
1.3.6.1.4.1.248.11.22.1.8.12Nodehm2DiagNetworkResourcesGroup
1.3.6.1.4.1.248.11.22.1.8.12.1Scalarhm2DiagNetworkCpuIfUtilizationread-onlycurrentThe current network utilization of the internal cpu interface in percent.
1.3.6.1.4.1.248.11.22.1.8.12.2Scalarhm2DiagNetworkCpuIfAverageUtilizationread-onlycurrentThe average network utilization of the internal cpu interface in percent, measured over the last 30 minutes.
1.3.6.1.4.1.248.11.22.3Nodehm2DiagnosticSNMPExtensionGroup
1.3.6.1.4.1.248.11.22.3.1Identityhm2PortMonitorSpeedDuplexErrorReturncurrentIndicates that the specified speed value is not supported by the port capabilities
1.3.6.1.4.1.248.11.22.3.2Identityhm2PortMonitorCndOvldDetInconsistenTholdValcurrentIndicates that the configured upper and lower threshold values are inconsistent
Type Definitions
NameSyntaxStatusDescription
Hm2LedStatusINTEGER { off(1), greenSolid(2), greenBlink1(3), greenBlink3(4), greenBlink4(5), greenBlink5(6), greenBlink5i(7), yellowSolid(8), yellowBlink1(9), yellowBlink3(10), yellowBlink4(11), yellowBlink5(12), redSolid(13), redBlink1(14), redBlink3(15), redBlink4(16), redBlink5(17) }currentStatus of LEDs available
Hm2LedTypeINTEGER { power(1), status(2), rm(3), envm(4), i1(5), i2(6) }currentTypes of LEDs available