MIB Viewer

HM2-POE-MIB

46 objects
Hirschmann Power over Ethernet Management MIB. This MIB contains the private extensions to the RFC 3621. Copyright (C) 2011. All Rights Reserved.
Imported Objects
HM2-DEVMGMT-MIBhm2IfacePhysIndex
HM2-TC-MIBhm2ConfigurationMibs HmEnabledStatus HmTimeHHMM24
SNMP-FRAMEWORK-MIB-- RFC 2578 SnmpAdminString
SNMPv2-SMIInteger32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
OIDNameAccessStatusDescription
1.3.6.1.4.1.248.11.12Identityhm2PoeMgmtMibHirschmann Power over Ethernet Management MIB. This MIB contains the private extensions to the RFC 3621. Copyright (C) 2011. All Rights Reserved.
1.3.6.1.4.1.248.11.12.0Nodehm2PoeMgmtMibNotifications
1.3.6.1.4.1.248.11.12.0.1Notificationhm2PoeMgmtModulePowerUsageOnNotificationcurrentThis Notification indicate PSE Threshold usage indication is on, the usage power is above the threshold. At least 500 msec must elapse between notifications be…
1.3.6.1.4.1.248.11.12.0.2Notificationhm2PoeMgmtModulePowerUsageOffNotificationcurrentThis Notification indicate PSE Threshold usage indication is on, the usage power is below the threshold. At least 500 msec must elapse between notifications be…
1.3.6.1.4.1.248.11.12.0.3Notificationhm2PoeMgmtPortMaxConfiguredPowerLimitExceededcurrentThis trap reports an exceeding of the configured power limit. This notification indicates that a PD consumes more power that the maximum configured on the port…
1.3.6.1.4.1.248.11.12.1Nodehm2PoeMgmtMibObjects
1.3.6.1.4.1.248.11.12.1.1Nodehm2PoeMgmtGroup
1.3.6.1.4.1.248.11.12.1.1.1Nodehm2PoeMgmtGlobalGroup
1.3.6.1.4.1.248.11.12.1.1.1.1Scalarhm2PoeMgmtAdminStatusread-writecurrentEnables/disables Power over Ethernet management on this device.
1.3.6.1.4.1.248.11.12.1.1.1.2Scalarhm2PoeMgmtReservedPowerread-onlycurrentReserved system power for active Power over Ethernet ports in Watts.
1.3.6.1.4.1.248.11.12.1.1.1.3Scalarhm2PoeMgmtDeliveredCurrentread-onlycurrentThe measured current delivered over Ethernet ports in milliamperes
1.3.6.1.4.1.248.11.12.1.1.2Tablehm2PoeMgmtPsuTablenot-accessiblecurrentThis table contains objects for each power supply type of the device (internal or external power supply).
1.3.6.1.4.1.248.11.12.1.1.2.1Rowhm2PoeMgmtPsuEntrynot-accessiblecurrentThe entries of the hm2PoeMgmtPsuTable.
1.3.6.1.4.1.248.11.12.1.1.2.1.1Columnhm2PoeMgmtPsuPowerread-onlycurrentThe power budget per psu type expressed in Watts. Psu types could be internal or external.
1.3.6.1.4.1.248.11.12.1.1.2.1.2Columnhm2PoeMgmtPsuReservedPowerread-onlycurrentThe reserved power (depending on actual power classes) per psu type expressed in Watts.
1.3.6.1.4.1.248.11.12.1.1.2.1.3Columnhm2PoeMgmtPsuDeliveredPowerread-onlycurrentThe measured usage power per psu type expressed in Watts.
1.3.6.1.4.1.248.11.12.1.1.2.1.4Columnhm2PoeMgmtPsuDeliveredCurrentread-onlycurrentThe measured current delivered per psu type expressed in milliamperes
1.3.6.1.4.1.248.11.12.1.1.3Tablehm2PoeMgmtPortTablenot-accessiblecurrentThis table contains objects for each Power over Ethernet interface of the device.
1.3.6.1.4.1.248.11.12.1.1.3.1Rowhm2PoeMgmtPortEntrynot-accessiblecurrentThe entry of the hm2PoeMgmtPortTable.
1.3.6.1.4.1.248.11.12.1.1.3.1.1Columnhm2PoeMgmtPortAdminEnableread-writecurrentenable (1) An interface which can provide the PSE functions. disable(2) The interface will act - as it would - if it had no PSE function.
1.3.6.1.4.1.248.11.12.1.1.3.1.2Columnhm2PoeMgmtPortConsumptionPowerread-onlycurrentMeasured usage power per interface expressed in Milliwatts.
1.3.6.1.4.1.248.11.12.1.1.3.1.3Columnhm2PoeMgmtPortDetectionStatusread-onlycurrentDescribes the operational status of the port PD detection. A value of disabled(1)- indicates that the PSE State diagram is in the state DISABLED. A value of de…
1.3.6.1.4.1.248.11.12.1.1.3.1.4Columnhm2PoeMgmtPortPowerPriorityread-writecurrentThis object controls the priority of the port from the point of view of a power management algorithm. The priority that is set by this variable could be used b…
1.3.6.1.4.1.248.11.12.1.1.3.1.5Columnhm2PoeMgmtPortPowerClassificationread-onlycurrentClassification is a way to tag different terminals on the Power over LAN network according to their power consumption. Devices such as IP telephones, WLAN acce…
1.3.6.1.4.1.248.11.12.1.1.3.1.6Columnhm2PoeMgmtPortNameread-writecurrentA manager will set the value of this variable to indicate the type of powered device that is connected to the port. The default value supplied by the agent if …
1.3.6.1.4.1.248.11.12.1.1.3.1.7Columnhm2PoeMgmtPortAllowedClassBitsread-writecurrentBit mask which defines allowed classes per interface.
1.3.6.1.4.1.248.11.12.1.1.3.1.8Columnhm2PoeMgmtPortAutoShutdownread-writecurrentEnables/disables automatic shutdown functionality per interface.
1.3.6.1.4.1.248.11.12.1.1.3.1.9Columnhm2PoeMgmtPortAutoShutdownTimeStartread-writecurrentStart time for the automatic shutdown functionality per interface.
1.3.6.1.4.1.248.11.12.1.1.3.1.10Columnhm2PoeMgmtPortAutoShutdownTimeEndread-writecurrentEnd time for the automatic shutdown functionality per interface.
1.3.6.1.4.1.248.11.12.1.1.3.1.11Columnhm2PoeMgmtPortClassValidread-onlycurrentEvaluates if class represented through pethPsePortPowerClassifications is valid or not. Class is valid if PD is delivered with power or in case of power exceed…
1.3.6.1.4.1.248.11.12.1.1.3.1.12Columnhm2PoeMgmtPortFastStartupread-writecurrentEnables/disables Power over Ethernet fast startup mode on given port. The default value is 'disable'.
1.3.6.1.4.1.248.11.12.1.1.3.1.13Columnhm2PoeMgmtPortMaxConsumptionPowerread-onlycurrentThe maximum observed power consumption (hm2PoeMgmtPortMaxConsumptionPower) value expressed in milliwatts used by the PD. The value is reset to 0 if the PoE adm…
1.3.6.1.4.1.248.11.12.1.1.3.1.14Columnhm2PoeMgmtPortPowerLimitread-writecurrentThe power limit per port expressed in milliwatts. If set to zero the power consumption limitation is disabled.
1.3.6.1.4.1.248.11.12.1.1.3.1.15Columnhm2PoeMgmtPortConsumptionCurrentread-onlycurrentMeasured current consumption per interface expressed in milliamperes (mA).
1.3.6.1.4.1.248.11.12.1.1.4Tablehm2PoeMgmtModuleTablenot-accessiblecurrentThis table contains objects for each plugged PoE module of the device. If the device is non-modular and supports PoE it contains only one entry.
1.3.6.1.4.1.248.11.12.1.1.4.1Rowhm2PoeMgmtModuleEntrynot-accessiblecurrentThe entries of the hm2PoeMgmtModuleTable.
1.3.6.1.4.1.248.11.12.1.1.4.1.1Columnhm2PoeMgmtModuleUnitIndexnot-accessiblecurrentUnit number - for stacking devices.
1.3.6.1.4.1.248.11.12.1.1.4.1.2Columnhm2PoeMgmtModuleSlotIndexnot-accessiblecurrentSlot number of the plugged PoE module.
1.3.6.1.4.1.248.11.12.1.1.4.1.3Columnhm2PoeMgmtModulePowerread-writecurrentConfigurable power budget per module expressed in Watts. The default value is hm2PoeMgmtModuleMaximumPower and depends on the hardware.
1.3.6.1.4.1.248.11.12.1.1.4.1.4Columnhm2PoeMgmtModuleMaximumPowerread-onlycurrentMaximum available power budget per module expressed in Watts. This value depends on the device or module.
1.3.6.1.4.1.248.11.12.1.1.4.1.5Columnhm2PoeMgmtModuleReservedPowerread-onlycurrentThe reserved power (depending on actual power classes) per module expressed in Watts.
1.3.6.1.4.1.248.11.12.1.1.4.1.6Columnhm2PoeMgmtModuleDeliveredPowerread-onlycurrentThe measured usage power per module expressed in Watts.
1.3.6.1.4.1.248.11.12.1.1.4.1.7Columnhm2PoeMgmtModulePowerSourceread-onlycurrentThis object displays the type of the PoE power source. internal (0) means that the PoE power is used from the internal PSU and external (1) means that a extern…
1.3.6.1.4.1.248.11.12.1.1.4.1.8Columnhm2PoeMgmtModuleUsageThresholdread-writecurrentThe usage power threshold per module expressed in percent. If this threshold is exceeded a alarm is initiated.
1.3.6.1.4.1.248.11.12.1.1.4.1.9Columnhm2PoeMgmtModuleNotificationControlEnableread-writecurrentThis object controls, on a per-module basis, whether or not notifications from the agent are enabled.
1.3.6.1.4.1.248.11.12.1.1.4.1.10Columnhm2PoeMgmtModuleDeliveredCurrentread-onlycurrentThe measured current consumption per module expressed in milliamperes (mA).