MIB Viewer

HMIOMODULE-SNMP-MIB

38 objects
The Hirschmann Private IO Module definitions for Platform devices.
Imported Objects
HMPRIV-MGMT-SNMP-MIBhmChassis hmChassisEvent
INET-ADDRESS-MIBInetPortNumber
SNMPv2-SMIInteger32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE
SNMPv2-TCDisplayString TEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.4.1.248.14.1.0.16NotificationhmIOModDigInputChangeTrapcurrentThis trap is sent if the state of an input changes. This trap is sent only when hmIOModConfigDigInputSnmpTrap is set to enabled (1).
1.3.6.1.4.1.248.14.1.0.17NotificationhmIOModDigOutputChangeTrapcurrentThis trap is sent if the state of an input changes. This trap is sent when hmIOModConfigDigOutputSnmpTrap is set to enabled (1) or when the output value change…
1.3.6.1.4.1.248.14.1.13IdentityhmIOModuleGroupThe Hirschmann Private IO Module definitions for Platform devices.
1.3.6.1.4.1.248.14.1.13.1NodehmIOModuleConfigGroup
1.3.6.1.4.1.248.14.1.13.1.1NodehmIOModConfigCommon
1.3.6.1.4.1.248.14.1.13.1.1.1ScalarhmIOModConfigDigInputAdminStateread-writecurrentenables sending SNMP traps or log events on input change. (if disable(2) input task will do nothing).
1.3.6.1.4.1.248.14.1.13.1.1.2ScalarhmIOModConfigDigOutputAdminStateread-writecurrentenables polling of output values (if disable(2) output task will do nothing).
1.3.6.1.4.1.248.14.1.13.1.1.3ScalarhmIOModConfigDigInputRefreshIntervalread-writecurrentThe refresh interval (in ms) of the input values. Minimum 500ms, Maximum 10000ms (10s).
1.3.6.1.4.1.248.14.1.13.1.1.4ScalarhmIOModConfigDigOutputRefreshIntervalread-writecurrentThe refresh interval (in ms) of the output values. Minimum 500ms, Maximum 10000ms (10s).
1.3.6.1.4.1.248.14.1.13.1.1.5ScalarhmIOModConfigDigOutputRetryCountread-writecurrentThe retry count for the output values. when after the number of configured retries no SNMP get request was answered, the output value (hmIOModOutputValue) will…
1.3.6.1.4.1.248.14.1.13.1.2TablehmIOModConfigDigInputTablenot-accessiblecurrentIO module config table for inputs
1.3.6.1.4.1.248.14.1.13.1.2.1RowhmIOModConfigDigInputEntrynot-accessiblecurrentIO module config entry for inputs
1.3.6.1.4.1.248.14.1.13.1.2.1.1ColumnhmIOModConfigDigInputModIDnot-accessiblecurrentThe module ID of an input.
1.3.6.1.4.1.248.14.1.13.1.2.1.2ColumnhmIOModConfigDigInputIDnot-accessiblecurrentThe ID of an input.
1.3.6.1.4.1.248.14.1.13.1.2.1.3ColumnhmIOModConfigDigInputLogEventread-writecurrentTrigger an event log when input status changes. If the value is disable (2), no event log entry will be written. If the value is enable (1), an event log entry…
1.3.6.1.4.1.248.14.1.13.1.2.1.4ColumnhmIOModConfigDigInputSnmpTrapread-writecurrentTrigger an SNMP trap log when input status changes. If the value is disable (2), no SNMP trap will be sent. If the value is enable (1), a SNMP trap will be sen…
1.3.6.1.4.1.248.14.1.13.1.3TablehmIOModConfigDigOutputTablenot-accessiblecurrentIO module config table for outputs
1.3.6.1.4.1.248.14.1.13.1.3.1RowhmIOModConfigDigOutputEntrynot-accessiblecurrentIO module config entry for outputs
1.3.6.1.4.1.248.14.1.13.1.3.1.1ColumnhmIOModConfigDigOutputModIDnot-accessiblecurrentThe module ID of an output.
1.3.6.1.4.1.248.14.1.13.1.3.1.2ColumnhmIOModConfigDigOutputIDnot-accessiblecurrentThe ID of an output.
1.3.6.1.4.1.248.14.1.13.1.3.1.3ColumnhmIOModConfigDigOutputLogEventread-writecurrentTrigger an event log when output status changes. If the value is disable (2), no event log entry will be written. If the value is enable (1), an event log entr…
1.3.6.1.4.1.248.14.1.13.1.3.1.4ColumnhmIOModConfigDigOutputSnmpTrapread-writecurrentTrigger an SNMP trap log when output status changes. If the value is disable (2), no SNMP trap will be sent. If the value is enable (1), a SNMP trap will be se…
1.3.6.1.4.1.248.14.1.13.1.3.1.5ColumnhmIOModConfigDigOutputSourceIPread-writecurrentThe IP address of an input mirrored to the output. Use 0.0.0.0 if the output should not be set. In this case hmIOModOutputValue is invalid (3). Use 127.0.0.1 i…
1.3.6.1.4.1.248.14.1.13.1.3.1.6ColumnhmIOModConfigDigOutputSourceModIDread-writecurrentThe module ID of an input mirrored to the output. Ignored when hmIOModConfigDigOutputSourceIP is 0.0.0.0.
1.3.6.1.4.1.248.14.1.13.1.3.1.7ColumnhmIOModConfigDigOutputSourceIDread-writecurrentThe ID of an input mirrored to the output. Ignored when hmIOModConfigDigOutputSourceIP is 0.0.0.0.
1.3.6.1.4.1.248.14.1.13.1.3.1.8ColumnhmIOModConfigDigOutputSourcePortread-writecurrentThe SNMP port number being used by the input mirrored to the output. This port would be the destination for the SNMP requests for polling the state of the inpu…
1.3.6.1.4.1.248.14.1.13.2NodehmIOModuleValueGroup
1.3.6.1.4.1.248.14.1.13.2.1TablehmIOModValueDigInputTablenot-accessiblecurrentIO module value table for inputs
1.3.6.1.4.1.248.14.1.13.2.1.1RowhmIOModValueDigInputEntrynot-accessiblecurrentIO module value entry for inputs
1.3.6.1.4.1.248.14.1.13.2.1.1.1ColumnhmIOModValueDigInputModIDnot-accessiblecurrentThe module ID of an input.
1.3.6.1.4.1.248.14.1.13.2.1.1.2ColumnhmIOModValueDigInputIDnot-accessiblecurrentThe ID of an input.
1.3.6.1.4.1.248.14.1.13.2.1.1.3ColumnhmIOModValueDigInputValueread-onlycurrentStatus of the input. If the value is not-available(0), then the IO module is not plugged in, if the value is high(1), the input has high (+24V) value, if the v…
1.3.6.1.4.1.248.14.1.13.2.2TablehmIOModValueDigOutputTablenot-accessiblecurrentIO module value table for outputs
1.3.6.1.4.1.248.14.1.13.2.2.1RowhmIOModValueDigOutputEntrynot-accessiblecurrentIO module value entry for outputs
1.3.6.1.4.1.248.14.1.13.2.2.1.1ColumnhmIOModValueDigOutputModIDnot-accessiblecurrentThe module ID of an Output.
1.3.6.1.4.1.248.14.1.13.2.2.1.2ColumnhmIOModValueDigOutputIDnot-accessiblecurrentThe ID of an Output.
1.3.6.1.4.1.248.14.1.13.2.2.1.3ColumnhmIOModValueDigOutputValueread-onlycurrentStatus of the output. If the value is not-available(0), then the IO module is not plugged in, if the value is high(1), the output has high (+24V) value, if the…
Type Definitions
NameSyntaxStatusDescription
HmEnabledStatusINTEGER { enable(1), disable(2) }currentStatus of a feature